Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 243
Filter
1.
Methods Mol Biol ; 2858: 243-264, 2025.
Article in English | MEDLINE | ID: mdl-39433681

ABSTRACT

Glaucoma is a common optic neuropathy characterized by degeneration of retinal ganglion cells (RGCs). Elevated intraocular pressure (IOP), that is, ocular hypertension, is the primary modifiable risk factor for glaucoma and the primary characteristic of most preclinical glaucoma models. Extensive genotype and phenotype diversity at relatively low cost and high accessibility makes laboratory mice an excellent preclinical model for glaucoma. The microbead occlusion model was introduced in 2010 as an inducible model of ocular hypertension in mice and is now one of the most extensively utilized models of rodent glaucoma. Subsequent modifications of the microbead model increased the magnitude and duration of IOP elevation, primarily through modification of injection materials. Despite its popularity, accessibility of the model is hindered by procedural consistency between users. Here we outline an updated and comprehensive protocol for execution of the microbead model that is focused on improving surgical and outcome measure consistency and on enabling single experimenter execution.


Subject(s)
Disease Models, Animal , Glaucoma , Intraocular Pressure , Ocular Hypertension , Animals , Ocular Hypertension/etiology , Mice , Glaucoma/etiology , Glaucoma/pathology , Retinal Ganglion Cells/pathology , Retinal Ganglion Cells/metabolism
2.
Transl Vis Sci Technol ; 13(10): 14, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39377753

ABSTRACT

Purpose: Expansion of the suprachoroidal space (SCS) by a hydrogel injection has been shown to reduce intraocular pressure (IOP) in rabbits as a potential treatment for ocular hypertension in glaucoma. Here, we evaluate the safety and efficacy of this approach in hypertensive and normotensive eyes in nonhuman primates. Methods: A microneedle was used to inject a hyaluronic acid-based hydrogel or saline solution (control) into the SCS of cynomolgus monkey eyes that were either normotensive (n = 7 experimental; n = 2 control eyes) or had induced ocular hypertension (n = 6 experimental; n = 3 control eyes). IOP and the degree of SCS expansion were monitored over time by tonometry and ultrasound biomicroscopy, respectively. Safety was evaluated through slit lamp, fundus, and histology examinations. Results: In hypertensive eyes, SCS injection with hydrogel initially reduced IOP by 47.5 ± 16.7%, and IOP returned to baseline in 38 days. In normotensive eyes, hydrogel injection initially reduced IOP by 38.8 ± 8.1% and IOP gradually returned to baseline also in 39 days. Sham injections resulted in mild IOP reduction in hypertensive eyes and normotensive eyes. The hydrogel injections were well tolerated by clinical assessments. Conclusions: IOP was reduced in nonhuman primates for over one month by sustained SCS expansion. This procedure was safe and simple to perform. These data confirm the translational potential of this treatment method. Further optimization of the hydrogel may provide longer durations of IOP reduction. Translational Relevance: A microneedle injection of hydrogel into the suprachoroidal space may provide a non-surgical, non-pharmacologic treatment for ocular hypertension in glaucoma patients.


Subject(s)
Hyaluronic Acid , Hydrogels , Intraocular Pressure , Macaca fascicularis , Needles , Ocular Hypertension , Animals , Intraocular Pressure/drug effects , Intraocular Pressure/physiology , Ocular Hypertension/drug therapy , Hyaluronic Acid/administration & dosage , Hyaluronic Acid/pharmacology , Hydrogels/administration & dosage , Disease Models, Animal , Choroid/diagnostic imaging , Tonometry, Ocular , Male , Injections, Intraocular , Female , Microscopy, Acoustic , Glaucoma/drug therapy
3.
bioRxiv ; 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39229235

ABSTRACT

Purpose: Cross-linked actin networks (CLANs) are prevalent in the glaucomatous trabecular meshwork (TM), yet their role in ocular hypertension remains unclear. We used a human TM cell line that spontaneously forms fluorescently-labeled CLANs (GTM3L) to explore the origin of CLANs, developed techniques to increase CLAN incidence in GMT3L cells, and computationally studied the biomechanical properties of CLAN-containing cells. Methods: GTM3L cells were fluorescently sorted for viral copy number analysis. CLAN incidence was increased by (i) differential sorting of cells by adhesion, (ii) cell deswelling, and (iii) cell selection based on cell stiffness. GTM3L cells were also cultured on glass or soft hydrogel to determine substrate stiffness effects on CLAN incidence. Computational models were constructed to mimic and study the biomechanical properties of CLANs. Results: All GTM3L cells had an average of 1 viral copy per cell. LifeAct-GFP expression level did not affect CLAN incidence rate, but CLAN rate was increased from ~0.28% to ~50% by a combination of adhesion selection, cell deswelling, and cell stiffness-based sorting. Further, GTM3L cells formed more CLANs on a stiff vs. a soft substrate. Computational modeling predicted that CLANs contribute to higher cell stiffness, including increased resistance of the nucleus to tensile stress when CLANs are physically linked to the nucleus. Conclusions: It is possible to greatly enhance CLAN incidence in GTM3L cells. CLANs are mechanosensitive structures that affect cell biomechanical properties. Further research is needed to determine the effect of CLANs on TM biomechanics and mechanobiology as well as the etiology of CLAN formation in the TM.

4.
bioRxiv ; 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39091756

ABSTRACT

Purpose: Aqueous humor inflow rate, a key parameter influencing aqueous humor dynamics, is typically measured by fluorophotometery. Analyzing fluorophotometric data depends, inter alia, on the volume of aqueous humor in the anterior, but not the posterior, chamber. Previous fluorophotometric studies of aqueous inflow rate in mice have assumed the ratio of anterior:posterior volumes in mice to be similar to those in humans. Our goal was to measure anterior and posterior chamber volumes in mice to facilitate better estimates of aqueous inflow rates. Methods: We used standard near-infrared optical coherence tomography (OCT) and robotic visible-light OCT (vis-OCT) to visualize, reconstruct and quantify the volumes of the anterior and posterior chambers of the mouse eye in vivo. We used histology and micro-CT scans to validate relevant landmarks from ex vivo tissues to facilitate in vivo measurement. Results: Posterior chamber volume is 1.1 times the anterior chamber volume in BALB/cAnNCrl mice, i.e. the anterior chamber constitutes about 47% of the total aqueous humor volume, which is very dissimilar to the situation in humans. Anterior chamber volumes in 2-month-old BALB/cAnNCrl and 7-month-old C57BL6/J mice were 1.55 ± 0.36 µL (n=10) and 2.41 ± 0.29 µL (n=8), respectively. This implies that previous studies likely over-estimated aqueous inflow rate by approximately two-fold. Conclusions: It is necessary to reassess previously reported estimates of aqueous inflow rates, and thus aqueous humor dynamics in the mouse. For example, we now estimate that only 0-15% of aqueous humor drains via the pressure-independent (unconventional) route, similar to that seen in humans and monkeys.

5.
Invest Ophthalmol Vis Sci ; 65(6): 4, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38833261

ABSTRACT

Purpose: Shear-induced nitric oxide (NO) production by Schlemm's canal (SC) endothelial cells provides a fast, IOP-sensitive feedback signal that normally contributes to IOP homeostasis. Our goal was to analyze the response of this homeostatic system under constant flow perfusion (as occurs in vivo) vs. constant pressure perfusion (as typical for laboratory perfusions). Methods: A mathematical model of aqueous humor dynamics, including shear-mediated NO signaling, was formulated and analyzed for stability. The model includes Goldmann's equation, accounting for proximal and distal outflow resistance, and describes how elevated IOP causes narrowing of SC lumen that increases the shear stress on SC cells. Elevated shear stress stimulates NO production, which acts to reduce outflow resistance and relax trabecular meshwork cells to decrease trabecular meshwork stiffness, affecting the SC luminal caliber. Results: During constant flow perfusion, the outflow system is typically stable, returning to baseline IOP after a perturbation. In contrast, during constant pressure perfusion, the outflow system can become unstable and exhibit a time-dependent change in outflow resistance that diverges from baseline. Conclusions: The stability of shear mediated IOP homeostasis is predicted to differ critically between constant flow vs. constant pressure perfusion. Because outflow facility is typically measured at a constant pressure in the laboratory, this instability may contribute to the characteristic time-dependent increase in outflow facility, known as washout, observed in many nonhuman species. Studies of IOP homeostasis should consider how the outflow system may respond differently under constant pressure vs. constant flow perfusion.


Subject(s)
Aqueous Humor , Homeostasis , Intraocular Pressure , Trabecular Meshwork , Intraocular Pressure/physiology , Homeostasis/physiology , Aqueous Humor/physiology , Aqueous Humor/metabolism , Humans , Trabecular Meshwork/metabolism , Trabecular Meshwork/physiology , Nitric Oxide/metabolism , Models, Theoretical
6.
bioRxiv ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38798683

ABSTRACT

Trabecular meshwork (TM) cell therapy has been proposed as a next-generation treatment for elevated intraocular pressure (IOP) in glaucoma, the most common cause of irreversible blindness. Using a magnetic cell steering technique with excellent efficiency and tissue-specific targeting, we delivered two types of cells into a mouse model of glaucoma: either human adipose-derived mesenchymal stem cells (hAMSCs) or induced pluripotent cell derivatives (iPSC-TM cells). We observed a 4.5 [3.1, 6.0] mmHg or 27% reduction in intraocular pressure (IOP) for nine months after a single dose of only 1500 magnetically-steered hAMSCs, associated with restoration of function to the conventional outflow pathway, as judged by increased outflow facility and TM cellularity. iPSC-TM cells were also effective, but less so, showing only a 1.9 [0.4, 3.3] mmHg or 13% IOP reduction and increased risk of tumorigenicity. In both cases, injected cells remained detectable in the iridocorneal angle three weeks post-transplantation. Based on the locations of the delivered cells, the mechanism of IOP lowering is most likely paracrine signaling. We conclude that magnetically-steered hAMSC cell therapy has potential for long-term treatment of ocular hypertension in glaucoma. One Sentence Summary: A novel magnetic cell therapy provided effective intraocular pressure control in a mouse model of glaucoma, motivating future translational studies.

7.
Aging Cell ; 23(7): e14160, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38566432

ABSTRACT

Age and elevated intraocular pressure (IOP) are the two primary risk factors for glaucoma, an optic neuropathy that is the leading cause of irreversible blindness. In most people, IOP is tightly regulated over a lifetime by the conventional outflow tissues. However, the mechanistic contributions of age to conventional outflow dysregulation, elevated IOP and glaucoma are unknown. To address this gap in knowledge, we studied how age affects the morphology, biomechanical properties and function of conventional outflow tissues in C57BL/6 mice, which have an outflow system similar to humans. As reported in humans, we observed that IOP in mice was maintained within a tight range over their lifespan. Remarkably, despite a constellation of age-related changes to the conventional outflow tissues that would be expected to hinder aqueous drainage and impair homeostatic function (decreased cellularity, increased pigment accumulation, increased cellular senescence and increased stiffness), outflow facility, a measure of conventional outflow tissue fluid conductivity, was stable with age. We conclude that the murine conventional outflow system has significant functional reserve in healthy eyes. However, these age-related changes, when combined with other underlying factors, such as genetic susceptibility, are expected to increase risk for ocular hypertension and glaucoma.


Subject(s)
Aging , Homeostasis , Intraocular Pressure , Mice, Inbred C57BL , Animals , Intraocular Pressure/physiology , Aging/physiology , Mice , Glaucoma/physiopathology , Glaucoma/pathology , Glaucoma/metabolism , Male , Humans
8.
J Biomech ; 168: 112113, 2024 May.
Article in English | MEDLINE | ID: mdl-38648717

ABSTRACT

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.


Subject(s)
Microscopy, Atomic Force , Animals , Microscopy, Atomic Force/methods , Mice , Rats , Sclera/physiology , Sclera/diagnostic imaging , Cornea/physiology , Cornea/diagnostic imaging , Trabecular Meshwork/physiology , Trabecular Meshwork/diagnostic imaging , Cryoultramicrotomy/methods , Optic Disk/diagnostic imaging , Optic Disk/physiology , Biomechanical Phenomena
9.
Invest Ophthalmol Vis Sci ; 65(4): 9, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38568619

ABSTRACT

Purpose: Intravitreal injection of drugs is commonly used for treatment of chorioretinal ocular pathologies, such as age-related macular degeneration. Injection causes a transient increase in the intraocular volume and, consequently, of the intraocular pressure (IOP). The aim of this work is to investigate how intravitreal flow patterns generated during the post-injection eye deflation influence the transport and distribution of the injected drug. Methods: We present mathematical and computational models of fluid motion and mass transport in the vitreous chamber during the transient phase after injection, including the previously unexplored effects of globe deflation as ocular volume decreases. Results: During eye globe deflation, significant fluid velocities are generated within the vitreous chamber, which can possibly contribute to drug transport. Pressure variations within the eye globe are small compared to IOP. Conclusions: Even if significant fluid velocities are generated in the vitreous chamber after drug injection, these are found to have negligible overall effect on drug distribution.


Subject(s)
Anterior Eye Segment , Intraocular Pressure , Intravitreal Injections , Biological Transport , Models, Theoretical
10.
J Biomech Eng ; 146(8)2024 08 01.
Article in English | MEDLINE | ID: mdl-38529724

ABSTRACT

Murine models are commonly used to study glaucoma, the leading cause of irreversible blindness. Glaucoma is associated with elevated intra-ocular pressure (IOP), which is regulated by the tissues of the aqueous outflow pathway. In particular, pectinate ligaments (PLs) connect the iris and trabecular meshwork (TM) at the anterior chamber angle, with an unknown role in maintenance of the biomechanical stability of the aqueous outflow pathway, thus motivating this study. We conducted histomorphometric analysis and optical coherence tomography-based finite element (FE) modeling on three cohorts of C57BL/6 mice: "young" (2-6 months), "middle-aged" (11-16 months), and "elderly" (25-32 months). We evaluated the age-specific morphology of the outflow pathway tissues. Further, because of the known pressure-dependent Schlemm's canal (SC) narrowing, we assessed the dependence of the SC lumen area on varying IOPs in age-specific FE models over a physiological range of TM/PL stiffness values. We found age-dependent changes in morphology of outflow tissues; notably, the PLs were more developed in older mice compared to younger ones. In addition, FE modeling demonstrated that murine SC patency is highly dependent on the presence of PLs and that increased IOP caused SC collapse only with sufficiently low TM/PL stiffness values. Moreover, the elderly model showed more susceptibility to SC collapse compared to the younger models. In conclusion, our study elucidated the previously unexplored role of PLs in the aqueous outflow pathway, indicating their function in supporting TM and SC under elevated IOP.


Subject(s)
Aqueous Humor , Glaucoma , Humans , Aged , Mice , Animals , Aqueous Humor/metabolism , Intraocular Pressure , Mice, Inbred C57BL , Trabecular Meshwork/metabolism
11.
12.
bioRxiv ; 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-37905127

ABSTRACT

Murine models are commonly used to study glaucoma, the leading cause of irreversible blindness. Glaucoma is associated with elevated intraocular pressure (IOP), which is regulated by the tissues of the aqueous outflow pathway. In particular, pectinate ligaments (PLs) connect the iris and trabecular meshwork (TM) at the anterior chamber angle, with an unknown role in maintenance of the biomechanical stability of the aqueous outflow pathway, thus motivating this study. We conducted histomorphometric analysis and optical coherence tomography-based finite element (FE) modeling on three cohorts of C57BL/6 mice: 'young' (2-6 months), 'middle-aged' (11-16 months), and 'elderly' (25-32 months). We evaluated the age-specific morphology of the outflow pathway tissues. Further, because of the known pressure-dependent Schlemm's canal (SC) narrowing, we assessed the dependence of the SC lumen area to varying IOPs in age-specific FE models over a physiological range of TM/PL stiffness values. We found age-dependent changes in morphology of outflow tissues; notably, the PLs were more developed in older mice compared to younger ones. In addition, FE modeling demonstrated that murine SC patency is highly dependent on the presence of PLs, and that increased IOP caused SC collapse only with sufficiently low TM/PL stiffness values. Moreover, the elderly model showed more susceptibility to SC collapse compared to the younger models. In conclusion, our study elucidated the previously unexplored role of PLs in the aqueous outflow pathway, indicating their function in supporting TM and SC under elevated IOP.

13.
bioRxiv ; 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38106150

ABSTRACT

Age and elevated intraocular pressure (IOP) are the two primary risk factors for glaucoma, an optic neuropathy that is the leading cause of irreversible blindness. In most people, IOP is tightly regulated over a lifetime by the conventional outflow tissues. However, the mechanistic contributions of age to conventional outflow dysregulation, elevated IOP and glaucoma are unknown. To address this gap in knowledge, we studied how age affects the morphology, biomechanical properties and function of conventional outflow tissues in C57BL/6 mice, which have an outflow system similar to humans. As reported in humans, we observed that IOP in mice was maintained within a tight range over their lifespan. Remarkably, despite a constellation of age-related changes to the conventional outflow tissues that would be expected to hinder aqueous drainage and impair homeostatic function (decreased cellularity, increased pigment accumulation, increased cellular senescence and increased stiffness), outflow facility, a measure of conventional outflow tissue fluid conductivity, was stable with age. We conclude that the murine conventional outflow system has significant functional reserve in healthy eyes. However, these age-related changes, when combined with other underlying factors, such as genetic susceptibility, are expected to increase risk for ocular hypertension and glaucoma.

14.
bioRxiv ; 2023 Nov 13.
Article in English | MEDLINE | ID: mdl-38014311

ABSTRACT

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.

15.
ACS Nano ; 17(18): 17931-17945, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37703202

ABSTRACT

Stem cell therapy has immense potential in a variety of regenerative medicine applications. However, clinical stem cell therapy is severely limited by challenges in assessing the location and functional status of implanted cells in vivo. Thus, there is a great need for longitudinal, noninvasive stem cell monitoring. Here we introduce a multidisciplinary approach combining nanosensor-augmented stem cell labeling with ultrasound guided photoacoustic (US/PA) imaging for the spatial tracking and functional assessment of transplanted stem cell fate. Specifically, our nanosensor incorporates a peptide sequence that is selectively cleaved by caspase-3, the primary effector enzyme in mammalian cell apoptosis; this cleavage event causes labeled cells to show enhanced optical absorption in the first near-infrared (NIR) window. Optimization of labeling protocols and spectral characterization of the nanosensor in vitro showed a 2.4-fold increase in PA signal from labeled cells during apoptosis while simultaneously permitting cell localization. We then successfully tracked the location and apoptotic status of mesenchymal stem cells in a mouse hindlimb ischemia model for 2 weeks in vivo, demonstrating a 4.8-fold increase in PA signal and spectral slope changes in the first NIR window under proapoptotic (ischemic) conditions. We conclude that our nanosensor allows longitudinal, noninvasive, and nonionizing monitoring of stem cell location and apoptosis, which is a significant improvement over current end-point monitoring methods such as biopsies and histological staining of excised tissue.


Subject(s)
Mesenchymal Stem Cells , Photoacoustic Techniques , Mice , Animals , Caspase 3 , Stem Cell Transplantation , Apoptosis , Photoacoustic Techniques/methods , Mammals
16.
Exp Eye Res ; 234: 109602, 2023 09.
Article in English | MEDLINE | ID: mdl-37488007

ABSTRACT

Glaucoma is the leading cause of irreversible blindness worldwide and its most prevalent subtype is primary open angle glaucoma (POAG). One pathological change in POAG is loss of cells in the trabecular meshwork (TM), which is thought to contribute to ocular hypertension and has thus motivated development of cell-based therapies to refunctionalize the TM. TM cell therapy has shown promise in intraocular pressure (IOP) control, but existing cell delivery techniques suffer from poor delivery efficiency. We employed a novel magnetic delivery technique to reduce the unwanted side effects of off-target cell delivery. Mesenchymal stem cells (MSCs) were labeled with superparamagnetic iron oxide nanoparticles (SPIONs) and after intracameral injection were magnetically steered towards the TM using a focused magnetic apparatus ("point magnet"). This technique delivered the cells significantly closer to the TM at higher quantities and with more circumferential uniformity compared to either unlabeled cells or those delivered using a "ring magnet" technique. We conclude that our point magnet cell delivery technique can improve the efficiency of TM cell therapy and in doing so, potentially increase the therapeutic benefits and lower the risk of complications such as tumorigenicity and immunogenicity.


Subject(s)
Glaucoma, Open-Angle , Glaucoma , Animals , Mice , Trabecular Meshwork/pathology , Glaucoma, Open-Angle/pathology , Glaucoma/pathology , Intraocular Pressure , Magnetic Phenomena
19.
Invest Ophthalmol Vis Sci ; 64(5): 22, 2023 05 01.
Article in English | MEDLINE | ID: mdl-37219510

ABSTRACT

Purpose: Ocular all-trans retinoic acid (atRA) levels are influenced by visual cues, and exogenous atRA has been shown to increase eye size in chickens and guinea pigs. However, it is not clear whether atRA induces myopic axial elongation via scleral changes. Here, we test the hypothesis that exogenous atRA will induce myopia and alter scleral biomechanics in the mouse. Methods: Male C57BL/6J mice were trained to voluntarily ingest atRA + vehicle (1% atRA in sugar, 25 mg/kg) (RA: n = 16 animals) or vehicle only (Ctrl: n = 14 animals). Refractive error (RE) and ocular biometry were measured at baseline and after 1 and 2 weeks of daily atRA treatment. Eyes were used in ex vivo assays to measure scleral biomechanics (unconfined compression: n = 18), total scleral sulfated glycosaminoglycan (sGAG) content (dimethylmethylene blue: n = 23), and specific sGAGs (immunohistochemistry: n = 18). Results: Exogenous atRA caused myopic RE and larger vitreous chamber depth (VCD) to develop by 1 week (RE: -3.7 ± 2.2 diopters [D], P < 0.001; VCD: +20.7 ± 15.1 µm, P < 0.001), becoming more severe by 2 weeks (RE: -5.7 ± 2.2 D, P < 0.001; VCD: +32.3 ± 25.8 µm, P < 0.001). The anterior eye biometry was unaffected. While scleral sGAG content was not measurably affected, scleral biomechanics were significantly altered (tensile stiffness: -30% ± 19.5%, P < 0.001; permeability: +60% ± 95.3%, P < 0.001). Conclusions: In mice, atRA treatment results in an axial myopia phenotype. Eyes developed myopic RE and larger VCD without the anterior eye being affected. The decrease in stiffness and increase in permeability of the sclera are consistent with the form-deprivation myopia phenotype.


Subject(s)
Myopia , Refractive Errors , Animals , Male , Mice , Biomechanical Phenomena , Mice, Inbred C57BL , Sclera
SELECTION OF CITATIONS
SEARCH DETAIL