Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 349
Filter
1.
Bone Jt Open ; 5(10): 832-836, 2024 Oct 04.
Article in English | MEDLINE | ID: mdl-39362655

ABSTRACT

Aims: The outcomes of patients with unexpected positive cultures (UPCs) during revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) remain unknown. The objectives of this study were to establish the prevalence and infection-free implant survival in UPCs during presumed aseptic single-stage revision THA and TKA at mid-term follow-up. Methods: This study included 297 patients undergoing presumed aseptic single-stage revision THA or TKA at a single treatment centre. All patients with at least three UPCs obtained during revision surgery were treated with minimum three months of oral antibiotics following revision surgery. The prevalence of UPCs and causative microorganisms, the recurrence of periprosthetic joint infections (PJIs), and the infection-free implant survival were established at minimum five years' follow-up (5.1 to 12.3). Results: Of the 297 patients undergoing aseptic revisions, 37 (12.5%) had at least three UPCs obtained during surgery. The UPC cohort included 23 males (62.2%) and 14 females (37.8%), with a mean age of 71.2 years (47 to 82). Comorbidities included smoking (56.8%), hypertension (48.6%), diabetes mellitus (27.0%), and chronic renal impairment (13.5%). The causative microorganisms included Staphylococcus epidermidis (49.6%), Bacillus species (18.9%), Micrococcus species (16.2%), and Cutibacterium acnes (16.2%). None of the study patients with UPCs developed further PJIs or required further surgical intervention during follow-up. Conclusion: The prevalence of UPCs during presumed aseptic revision THA and TKA was 12.5%. The most common causative microorganisms were of low virulence, and included S. epidermidis, Bacillus species, Micrococcus species, and C. acnes. Microorganism-specific antibiotic treatment for minimum three months' duration of UPCs in presumed aseptic revision arthroplasty was associated with excellent infection-free implant survival at mid-term follow-up.

2.
HSS J ; 20(2): 141-181, 2024 May.
Article in English | MEDLINE | ID: mdl-39281983

ABSTRACT

The evaluation, classification, and treatment of significant bone loss after total knee arthroplasty (TKA) continue to be a complex and debated topic in revision TKA (rTKA). Despite the introduction of new evidence and innovative technologies aimed at addressing the approach and care of severe bone loss in rTKA, there is no single document that systematically incorporates these newer surgical approaches. Therefore, a comprehensive review of the treatment of severe bone loss in rTKA is necessary. The Stavros Niarchos Foundation Complex Joint Reconstruction Center Hospital for Special Surgery, dedicated to clinical care and research primarily in revision hip and knee replacement, convened a Management of Bone Loss in Revision TKA symposium on June 24, 2022. At this meeting, the 42 international invited experts were divided into groups; each group was assigned to discuss questions related to 1 of the 4 topics: (1) assessing preoperative workup and imaging, anticipated bone loss, classification system, and implant surveillance; (2) achieving durable fixation in the setting of significant bone loss in revision TKA; (3) managing patellar bone loss and the extensor mechanism in cases of severe bone loss; and (4) considering the use of complex modular replacement systems: hinges, distal femoral, and proximal tibial replacements. Each group came to consensus, when possible, based on an extensive literature review and interactive discussion on their group topic. This document reviews each these 4 areas, the consensus of each group, and directions for future research.

5.
Bone Joint J ; 106-B(10): 1039-1043, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39348913

ABSTRACT

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team's overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise.


Subject(s)
Hearing Loss, Noise-Induced , Noise, Occupational , Operating Rooms , Humans , Hearing Loss, Noise-Induced/etiology , Hearing Loss, Noise-Induced/prevention & control , Noise, Occupational/adverse effects , Orthopedic Procedures , Occupational Diseases/etiology , Occupational Diseases/prevention & control , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control
7.
Bone Joint J ; 106-B(9): 898-906, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39216856

ABSTRACT

Aims: The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. Methods: This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed. Results: The BOne trauma and Soft-Tissue Injury classification system in total Hip arthroplasty (BOSTI Hip) grades osseous acetabular trauma and periarticular muscle damage during THA. The classification system has an interclass correlation coefficient of 0.90 (95% CI 0.86 to 0.93) for interobserver agreement and 0.89 (95% CI 0.84 to 0.93) for intraobserver agreement. RO THA was associated with improved BOSTI Hip scores (p = 0.002) and more pristine osseous surfaces in the anterior superior (p = 0.001) and posterior superior (p < 0.001) acetabular quadrants compared with CO THA. There were no differences between the groups in relation to injury to the gluteus medius (p = 0.084), obturator internus (p = 0.241), piriformis (p = 0.081), superior gamellus (p = 0.116), inferior gamellus (p = 0.132), quadratus femoris (p = 0.208), and vastus lateralis (p = 0.135), but overall combined muscle injury was reduced in RO THA compared with CO THA (p = 0.023). Discussion: The proposed BOSTI Hip classification provides a reproducible grading system for stratifying iatrogenic bone trauma and soft-tissue injury during THA. RO THA was associated with improved BOSTI Hip scores, more pristine osseous acetabular surfaces, and reduced combined periarticular muscle injury compared with CO THA. Further research is required to understand if these intraoperative findings translate to differences in clinical outcomes between the treatment groups.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Soft Tissue Injuries , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Female , Male , Middle Aged , Aged , Soft Tissue Injuries/classification , Soft Tissue Injuries/etiology , Acetabulum/injuries , Acetabulum/diagnostic imaging , Acetabulum/surgery , Observer Variation , Iatrogenic Disease , Adult , Intraoperative Complications/classification , Intraoperative Complications/etiology , Aged, 80 and over
8.
Bone Joint J ; 106-B(9): 892-897, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39216858

ABSTRACT

Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon's philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation.


Subject(s)
Arthroplasty, Replacement, Knee , Imaging, Three-Dimensional , Surgery, Computer-Assisted , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Knee/methods , Tomography, X-Ray Computed/methods , Surgery, Computer-Assisted/methods , Knee Prosthesis , Preoperative Care/methods
9.
Bone Jt Open ; 5(8): 671-680, 2024 Aug 14.
Article in English | MEDLINE | ID: mdl-39139101

ABSTRACT

Aims: Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement. Methods: This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy. Results: We identified nine predictors from an analysis of baseline spinopelvic characteristics and surgical planning parameters. Using fivefold cross-validation, the LGBM achieved 70.2% impingement prediction accuracy. With impingement data, the LGBM estimated direction with 85% accuracy, while the support vector machine (SVM) determined impingement type with 72.9% accuracy. After integrating imaging data with a multilayer perceptron (tabular) and a convolutional neural network (radiograph), the LGBM's prediction was 68.1%. Both combined and LGBM-only had similar impingement direction prediction rates (around 84.5%). Conclusion: This study is a pioneering effort in leveraging AI for impingement prediction in THA, utilizing a comprehensive, real-world clinical dataset. Our machine-learning algorithm demonstrated promising accuracy in predicting impingement, its type, and direction. While the addition of imaging data to our deep-learning algorithm did not boost accuracy, the potential for refined annotations, such as landmark markings, offers avenues for future enhancement. Prior to clinical integration, external validation and larger-scale testing of this algorithm are essential.

10.
Bone Joint J ; 106-B(8): 760-763, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39084644

Subject(s)
Humans
12.
Bone Joint J ; 106-B(7): 680-687, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38945538

ABSTRACT

Aims: Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods: This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results: There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion: Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Reoperation , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Knee/methods , Male , Female , Prospective Studies , Robotic Surgical Procedures/methods , Aged , Middle Aged , Treatment Outcome , Range of Motion, Articular , Follow-Up Studies , Length of Stay , Postoperative Complications , Knee Prosthesis , Aged, 80 and over , Osteoarthritis, Knee/surgery
13.
Bone Joint J ; 106-B(7): 640-641, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38945530
14.
Orthop J Sports Med ; 12(6): 23259671241246699, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38840794

ABSTRACT

Background: The jackling position within rugby has not been previously described as a mechanism for proximal hamstring injuries. Hypothesis: Acute surgical repair of proximal hamstring avulsion injuries sustained from the jackling contact position enables a return to a previous level of sporting activity with low risk of recurrence. Study Design: Case series; Level of evidence, 4. Methods: This study included 54 professional rugby players (mean age, 26 ± 4.8 years) who underwent acute primary surgical repair of complete, proximal hamstring avulsion injuries. The mean follow-up time was 17 months (range, 12-24 months). Mean isometric hamstring strength and function testing was performed at 3 months and 1 year after repair. Results: Of the 54 players, 51 (94.4%) returned to their preinjury level of sporting activity. The mean time from surgical repair to full sporting activity was 7 months (range, 4-12 months). No patients had recurrence of the primary injury. At 1 year postoperatively, patients had significantly restored mean isometric hamstring muscle strength when compared with the uninjured leg at 0° (98.4% ± 2.8%), 15° (95.9% ± 2.9%), and 45° (92.9% ± 4.1%); improved Lower Extremity Functional Score (78.0 ± 2.0); and improved Marx activity rating score (14.3 ± 1.5) (P < .001 for all). Conclusion: Acute surgical repair of proximal hamstring avulsion injuries caused by the contact jackling position produced a high return to preinjury level of sporting activity, increased muscle strength, and improved functional outcome scores, with a low risk of recurrence at short-term follow-up.

15.
J Arthroplasty ; 39(9S1): S80-S87, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38810812

ABSTRACT

BACKGROUND: Preoperative planning in total hip arthroplasty (THA) involves utilizing radiographs or advanced imaging modalities, including computerized tomography scans, for precise prediction of implant sizing and positioning. This study aimed to compare 3-dimensional (3D) versus 2-dimensional (2D) preoperative planning in primary THA with respect to key surgical metrics, including restoration of the horizontal and vertical center of rotation (COR), combined offset, and leg length. METHODS: This study included 60 patients undergoing primary THA for symptomatic hip osteoarthritis (OA), randomly allocated to either robotic arm-assisted or conventional THA. Digital 2D templating and 3D planning using the robotic software were performed for all patients. All measurements to evaluate the accuracy of templating methods were conducted on the preoperative computerized tomography scanogram, using the contralateral hip as a reference. Sensitivity analyses explored differences between 2D and 3D planning in patients who had superolateral or medial OA patterns. RESULTS: Compared to 2D templating, 3D templating was associated with less medialization of the horizontal COR (-1.2 versus -0.2 mm, P = .002) and more accurate restoration of the vertical COR (1.63 versus 0.3 mm, P < .001) with respect to the contralateral side. Furthermore, 3D templating was superior for planned restoration of leg length (+0.23 versus -0.74 mm, P = .019). Sensitivity analyses demonstrated that in patients who had medial OA, 3D planning resulted in less medialization of horizontal COR and less offset reduction. Conversely, in patients who had superolateral OA, there was less lateralization of horizontal COR and less offset increase using 3D planning. Additionally, 3D planning showed superior reproducibility for stem, acetabular cup sizes, and neck angle, while 2D planning often led to smaller stem and cup sizes. CONCLUSIONS: Our findings indicated higher accuracy in the planned restoration of native joint mechanics using 3D planning. Additionally, this study highlights distinct variances between the 2 planning methods across different OA pattern subtypes, offering valuable insights for clinicians employing 2D planning.


Subject(s)
Arthroplasty, Replacement, Hip , Imaging, Three-Dimensional , Osteoarthritis, Hip , Preoperative Care , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Hip/methods , Female , Male , Middle Aged , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/diagnostic imaging , Aged , Preoperative Care/methods , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis , Robotic Surgical Procedures/methods
16.
J Bone Joint Surg Am ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38739702

ABSTRACT

BACKGROUND: The objective of this study was to evaluate the correlation in measurements of the lower-limb coronal alignment between long-leg radiographs (LLRs) and computed tomography (CT) scanograms that were made during preoperative planning for robotic-arm-assisted knee arthroplasty. On the basis of published evidence demonstrating a good correlation between these imaging modalities in measuring the lower-limb mechanical axis, we hypothesized that there would be no significant differences between the 2 in the present study. METHODS: This multicenter cohort study across 3 tertiary centers included 300 patients undergoing primary robotic-arm-assisted total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) for whom LLRs and CT scanograms were available preoperatively. The study involved measuring the medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), hip-knee-ankle angle (HKA), joint line obliquity (JLO), joint-line convergence angle (JLCA), and arithmetic HKA (aHKA). The aHKA represents a method for estimating constitutional alignment using angles that are unaffected by joint-space narrowing. RESULTS: Strong correlations (p < 0.001) between the imaging modalities were found for the HKA (correlation coefficient, 0.912), aHKA (0.883), MPTA (0.820), LDFA (0.871), and JLO (0.778). A weaker correlation was observed for the JLCA in valgus knees as compared with varus knees (Spearman coefficients, 0.412 and 0.518, respectively). Regression models demonstrated that the degree of agreement was associated with the preoperative intra-articular deformity and the positioning of the lower limb during the CT scan (i.e., the lower-limb rotational angle). An initial JLCA within ±5° was associated with higher agreement. CONCLUSIONS: We observed a strong correlation between LLRs and CT scanograms that were made during the preoperative planning stage of robotic-arm-assisted knee arthroplasty, implying that CT scanograms can reliably be utilized to estimate the coronal alignment of the knee, potentially replacing the need for LLRs. Nevertheless, to attain a higher degree of agreement, it is crucial to ensure appropriate radiographic positioning of the lower limb. Additionally, surgeons must remain vigilant regarding potential discrepancies in cases involving substantial deformities. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

18.
Bone Joint J ; 106-B(5 Supple B): 139, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38689570
SELECTION OF CITATIONS
SEARCH DETAIL