1.
Circ Rep ; 6(10): 407-414, 2024 Oct 10.
Article in English | MEDLINE | ID: mdl-39391552

ABSTRACT

Background: Patients who achieve improved left ventricular ejection fraction (LVEF >35%) with cardiac resynchronization therapy (CRT) are at a lower risk of ventricular arrhythmia (VA). Little is known about the significance of the B-type natriuretic peptide (BNP) level for the risk of VA. This study investigated the risk factors for VA in CRT and the risk stratification of VA with BNP in CRT with improved LVEF. Methods and Results: This study evaluated 352 CRT patients from 2012 to 2020. Patients were categorized into 2 groups: improved LVEF (impEF; LVEF >35%), and low LVEF (lowEF; LVEF ≤35%). The serum BNP levels 6 months after CRT device implantation were measured. The primary endpoint was defined as VA requiring treatment with anti-tachycardia pacing or shock or persisting for ≥30 s. Overall, 102 patients had improved LVEF. The impEF group had a significantly lower VA risk than the lowEF group. Patients with low BNP had a lower VA risk than those with high BNP; however, no significant difference was observed between patients with high BNP and those in the lowEF group. Univariate analysis revealed that high BNP was a predictor of VA in the impEF group. Conclusions: The VA risk is reduced with improved LVEF after CRT but not with high BNP levels. The post-BNP level after CRT implantation is a useful marker for predicting VA in patients with improved LVEF.

2.
J Cardiol Cases ; 29(5): 214-217, 2024 May.
Article in English | MEDLINE | ID: mdl-39100517

ABSTRACT

An implantable loop recorder (ILR) is now widely used for differential diagnosis of unexplained syncope or recurrent syncope with unknown causes. In the inherited arrhythmia syndromes, ILR may be useful for management of the therapeutic strategies; however, there is no obvious evidence to uncover arrhythmic syncope by ILR in long-QT syndrome (LQTS) patients. Here we experienced a 19-year-old female patient with LQTS type 1 who had recurrent syncope even after beta-blocker therapy but no arrhythmias were documented, and some episodes might be due to non-cardiogenic causes. Implantable cardioverter defibrillator (ICD) therapy was also recommended; however, she could not accept ICD but was implanted with ILR for further continuous monitoring. Two years later, she suffered syncope during a brief run, and ILR recorded an electrocardiogram at that moment. Thus a marked QT interval prolongation as well as T-wave alternance resulting in development of torsades de pointes could be detected. Although ILR is just a diagnostic tool but does not prevent sudden cardiac death, most arrhythmic events in LQTS are transient and sometimes hard to be diagnosed as arrhythmic syncope. ILR may provide direct supportive evidence to select the optimal therapeutic strategy in cases where syncope is difficult to diagnose. Learning objective: Long-QT syndrome (LQTS) patients often suffer recurrent syncope even after beta-blocker therapy, but torsades de pointes (TdP) is not always detected by standard 12­lead electrocardiogram or Holter monitoring, and some syncope might be non-cardiogenic. In this case, implantable loop recorder (ILR) documented the evidence of QT interval prolongation and beat-by-beat T-wave alternance subsequent TdP. Thus, ILR may provide useful evidence for the optimal treatment strategy in LQTS cases where syncope is difficult to diagnose.

3.
Heart Rhythm ; 2024 Aug 23.
Article in English | MEDLINE | ID: mdl-39181486

ABSTRACT

BACKGROUND: The SMART Pass algorithm for subcutaneous implantable cardioverter-defibrillator prevents inappropriate shocks due to oversensing. The mechanisms and significance of SMART Pass deactivation remain unclear. OBJECTIVE: The objective of this study was to assess whether SMART Pass deactivation is associated with inappropriate shocks and to elucidate the underlying mechanism. METHODS: We retrospectively investigated 115 patients who underwent subcutaneous implantable cardioverter-defibrillator implantation between 2016 and 2021. SMART Pass deactivation and inappropriate shocks during follow-up were assessed. The QRS amplitudes of the subcutaneous (S-ECG) and 12-lead electrocardiogram (ECG) at the time of implantation (pre) and SMART Pass deactivation (post) were measured. The patients were divided into the SP-ON group with SMART Pass consistently on and the SP-OFF group with the experience of SMART Pass deactivation. RESULTS: Three of 12 patients in the SP-OFF group experienced inappropriate shocks during a median follow-up of 1094 (interquartile range, 887-1502) days compared with 4 of 87 patients in the SP-ON group. Pre- and post-S-ECG QRS amplitudes were significantly lower in the SP-OFF group than in the SP-ON group (both P < .05), despite similar 12-lead ECG QRS amplitude in both groups. A significant temporary drop in the QRS amplitude of the S-ECG led to SMART Pass deactivation (pre-QRS amplitude vs amplitude at deactivation, P = .015; 95% CI, 0.3-1.9). CONCLUSION: The rate of inappropriate shocks was numerically higher after SMART Pass deactivation. A low QRS amplitude in S-ECG was a potential risk factor for SMART Pass deactivation. Careful follow-up and suitable management are required for managing patients with risks of SMART Pass deactivation.

4.
Circ J ; 88(9): 1425-1431, 2024 Aug 23.
Article in English | MEDLINE | ID: mdl-38960680

ABSTRACT

BACKGROUND: This study compared the stability of the Medtronic Attain Stability Quad (ASQ), a novel quadripolar active fixation left ventricular (LV) lead with a side helix, to that of conventional quadripolar leads with passive fixation (non-ASQ) and evaluated their LV lead performance. METHODS AND RESULTS: In all, 183 consecutive patients (69 ASQ, 114 non-ASQ) who underwent cardiac resynchronization therapy (CRT) between January 2018 and June 2021 were enrolled. Complications, including elevated pacing capture threshold (PCT) levels, phrenic nerve stimulation (PNS), and LV lead dislodgement, were analyzed during the postimplantation period until the first outpatient visit after discharge. The frequency of LV lead-related complications was significantly lower in the ASQ than non-ASQ group (14% vs. 30%, respectively; P=0.019). Specifically, LV lead dislodgement occurred only in the non-ASQ group, and elevated PCT levels were significantly lower in the ASQ group (7% vs. 23%; P=0.007). Kaplan-Meier analysis confirmed a significantly lower incidence of LV lead-related complications in the ASQ group (log-rank P=0.005). Cox multivariable regression analysis showed a significant reduction in lead-related complications associated with ASQ (hazard ratio 0.44; 95% confidence interval 0.23-0.83; P=0.011). CONCLUSIONS: The ASQ group exhibited fewer LV lead-related complications requiring reintervention and setting changes than the non-ASQ group. Thus, the ASQ may be a favorable choice for CRT device implantation.


Subject(s)
Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Humans , Male , Aged , Female , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy/adverse effects , Middle Aged , Heart Failure/therapy , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Aged, 80 and over , Retrospective Studies , Treatment Outcome
5.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1576-1588, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38864810

ABSTRACT

BACKGROUND: Epicardial unipolar mapping has not been thoroughly investigated in Brugada syndrome (BrS). OBJECTIVES: This study aims to examine the characteristics of epicardial unipolar potentials in BrS and investigate the differences from overt cardiomyopathy. METHODS: Epicardial mapping was performed in 8 patients with BrS and 6 patients with cardiomyopathy. We investigated the J-wave amplitudes using unipolar recordings at delayed potential (DP) sites via bipolar recordings. The repolarization time (RT) at and around the DP recording sites was measured, and maximum dispersion of the RT divided by the distance was defined as the RT dispersion index. RESULTS: Epicardial mapping at baseline revealed significantly higher J-wave amplitude with bipolar DP in patients with BrS than in patients with cardiomyopathy. J-wave amplitude ≥0.42 mV had 99.1% sensitivity and 100% specificity for diagnosing BrS. The RT dispersion index was significantly higher in patients with BrS than in patients with cardiomyopathy at baseline. In all patients with BrS, coved-type unipolar electrograms without negative T waves (short RT) appeared close to coved-type electrograms with negative T waves (long RT) at the DP recording sites after pilsicainide administration. Thus, a steep RT dispersion was observed in this region, and ventricular arrhythmias emerged from this shorter RT area in all 3 patients with BrS in whom ventricular arrhythmias were induced. CONCLUSIONS: Bipolar DP-related prominent unipolar J waves and steep repolarization gradients may be more specific for characterizing BrS than for overt cardiomyopathy. Ventricular arrhythmias in BrS are associated with a steep repolarization gradient, indicating phase 2 re-entry as a possible cause.


Subject(s)
Brugada Syndrome , Electrocardiography , Epicardial Mapping , Humans , Brugada Syndrome/physiopathology , Male , Middle Aged , Female , Adult , Electrophysiologic Techniques, Cardiac/methods , Aged , Cardiomyopathies/physiopathology
6.
Br J Pharmacol ; 181(18): 3401-3419, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38773354

ABSTRACT

BACKGROUND AND PURPOSE: The ryanodine receptor 2 (RyR2) is present in both the heart and kidneys, and plays a crucial role in maintaining intracellular Ca2+ homeostasis in cells in these organs. This study aimed to investigate the impact of M201-A on RyR2, as well as studying its effects on cardiac and renal functions in preclinical and clinical studies. EXPERIMENTAL APPROACH: Following the administration of M201-A (1,4-benzothiazepine-1-oxide derivative), we monitored diastolic Ca2+ leak via RyR2 and intracellular Ca2+ concentration in isolated rat cardiomyocytes and in cardiac and renal function in animals. In a clinical study, M201-A was administered intravenously at doses of 0.2 and 0.4 mg·kg-1 once daily for 20 min for four consecutive days in healthy males, with the assessment of haemodynamic responses. KEY RESULTS: In rat heart cells, M201-A effectively inhibited spontaneous diastolic Ca2+ leakage through RyR2 and exhibited positive lusi-inotropic effects on the rat heart. Additionally, it enhanced natriuresis and improved renal function in dogs. In human clinical studies, when administered intravenously, M201-A demonstrated an increase in natriuresis, glomerular filtration rate and creatinine clearance, while maintaining acceptable levels of drug safety and tolerability. CONCLUSIONS AND IMPLICATIONS: The novel drug M201-A inhibited diastolic Ca2+ leak via RyR2, improved cardiac lusi-inotropic effects in rats, and enhanced natriuresis and renal function in humans. These findings suggest that this drug may offer a potential new treatment option for chronic kidney disease and heart failure.


Subject(s)
Kidney , Natriuresis , Ryanodine Receptor Calcium Release Channel , Animals , Male , Ryanodine Receptor Calcium Release Channel/metabolism , Ryanodine Receptor Calcium Release Channel/drug effects , Dogs , Humans , Rats , Natriuresis/drug effects , Kidney/drug effects , Kidney/metabolism , Rats, Sprague-Dawley , Adult , Myocytes, Cardiac/drug effects , Myocytes, Cardiac/metabolism , Thiazepines/pharmacology , Calcium/metabolism , Dose-Response Relationship, Drug , Middle Aged , Cardiotonic Agents/pharmacology , Cardiotonic Agents/administration & dosage , Female
8.
J Cardiol ; 84(3): 165-169, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38679318

ABSTRACT

BACKGROUND: The adaptive cardiac resynchronization therapy (aCRT) algorithm enables synchronized left ventricular pacing (sLVP) to achieve fusion with intrinsic right ventricular activation. Although sLVP presents benefits over biventricular pacing, the adequate sLVP rate for better clinical outcomes remains unclear. We aimed to assess the association between sLVP rates and clinical outcomes. METHODS: Our study cohort included 271 consecutive patients, who underwent CRT implantation between April 2016 and August 2021. RESULTS: We evaluated 63 patients on whom we applied the aCRT algorithm [48 men, mean age: 64 ±â€¯14 years; median follow-up period: 316 days (interquartile range: 212-809 days)]. At the 6-month follow-up after CRT implantation, the frequency of CRT responders was 71 % (n = 45). The sLVP rate was significantly higher in responders than in non-responders (75 ±â€¯30 % vs. 47 ±â€¯40 %, p = 0.003). Receiver operating characteristics curve analysis revealed that the optimal cut-off value during the sLVP rate was 59.4 % for the prediction of CRT responders (area under the curve, 0.70; sensitivity, 80 %; specificity, 61 %; positive predictive value, 84 %; and negative predictive value, 55 %). Kaplan-Meier analysis demonstrated that the higher-sLVP group (sLVP ≧59.4 %, n = 43) had a better prognosis (cardiac death and heart failure hospitalization) than the lower-sLVP group (sLVP <59.4 %, n = 20) (log-rank p < 0.001). Multivariate Cox hazard analysis revealed that a higher sLVP rate was associated with a good prognosis (p < 0.001). CONCLUSIONS: sLVP was associated with CRT response, and a higher sLVP rate (≧59.4 %) was important for good prognosis in patients with aCRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Male , Cardiac Resynchronization Therapy/methods , Female , Middle Aged , Aged , Heart Failure/therapy , Heart Failure/physiopathology , Algorithms , Treatment Outcome , Heart Ventricles/physiopathology , Retrospective Studies , ROC Curve , Follow-Up Studies
9.
Article in English | MEDLINE | ID: mdl-38630335

ABSTRACT

BACKGROUND: An adaptive cardiac resynchronization therapy (aCRT) algorithm allows continuous adjustments of pacing timings of atrioventricular delays by periodic automatic evaluation of electrical conduction. This applies to patients with an atrioventricular block and is effective in cardiac resynchronization therapy (CRT) devices; however, whether this algorithm benefits patients with pacemaker dependency is uncertain. METHODS: This study examined the clinical impact of an aCRT algorithm in patients diagnosed with heart failure with reduced ejection fraction and pacemaker dependency. A total of 359 patients underwent CRT between January 2016 and December 2022. Patients undergoing pacemaker-dependent CRT with the aCRT algorithm function were selected. Sixty-four patients with pacemaker dependency (31 with aCRT algorithm and 33 without) were included. Pacemaker dependency was defined as the absence of spontaneous ventricular activity during the sensing test at VVI 30 bpm or prolonged atrioventricular delay (> 300 ms). The primary endpoint was the composite clinical outcome of all-cause death or hospitalization for heart failure. RESULTS: No significant differences were observed in baseline characteristics between groups. During a median follow-up of 1,067 days (interquartile range 553-1,776 days), aCRT reduced the risk of composite clinical outcomes in patients with pacemaker dependency (log-rank P = 0.028). In addition, using the aCRT algorithm was an independent predictor of the composite clinical outcomes in the multivariate analysis (hazard ratio 0.34, 95% confidence interval: 0.12-0.94, P = 0.038). CONCLUSION: The aCRT algorithm significantly reduced the risk of adverse clinical outcomes in patients with pacemaker dependency. This algorithm may be an important tool for managing such patients.

10.
Hypertens Res ; 47(6): 1555-1566, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38443615

ABSTRACT

Inequalities in health behaviors are thought to contribute to inequalities in hypertension. This study examined the extent to which modifiable mediating factors explain income inequalities in hypertension. This repeated cross-sectional study used data from National Database of Health Insurance Claims and Specific Health Checkups of Japan (NDB) from 2009 to 2015. Those aged between 40 and 74 were enrollees in the Specific Health Checkups. Hypertension was defined as systolic blood pressure ≥140 mmHg or diastolic blood pressure ≥90, or the use of antihypertensive medication. The mediating effects of exercise, obesity, smoking, and alcohol drinking on the association between income, as an indicator of SES, and hypertension were determined by the Karlson-Holm-Breen (KHB) method. The mean age of the 68,684,025 men and 59,118,221 women was 54.7 (SD = 9.6) and 56.7 (SD = 10.0) years, respectively. Prevalence of hypertension was higher in the lowest income group (48.6% for men, 40.2% for women) than in the highest income group (33.3% for men, 21.5% for women). Inequalities tended to increase over time. Inequalities were larger among those who did not use antihypertensive medication. Modifiable risks explained 10.6% of the association between income and hypertension for men and 15.1% for women. In men, drinking and obesity explained 8.8% and 5.5% of the inequalities in hypertension, respectively. In women, obesity explained 18.8%. Exercise increased the proportion mediated over time. Smoking explained 5.5% among women taking antihypertensive medication. There were health inequalities in hypertension among Japanese adults, and the modifiable risk factors partially explained the inequalities.


Subject(s)
Hypertension , Socioeconomic Factors , Humans , Male , Hypertension/epidemiology , Middle Aged , Female , Risk Factors , Cross-Sectional Studies , Adult , Aged , Japan/epidemiology , Prevalence , Smoking/epidemiology , Alcohol Drinking/epidemiology , Income , Obesity/epidemiology , Exercise
11.
Heart Rhythm ; 21(2): 163-171, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37739199

ABSTRACT

BACKGROUND: Conflicting data are available on whether ventricular arrhythmia (VA) or shock therapy increases mortality. Although cardiac resynchronization therapy (CRT) reduces the risk of VA, little is known about the prognostic value of VA among patients with CRT devices. OBJECTIVES: The purpose of this study was to evaluate the implications of VA as a prognostic marker for CRT. METHODS: We investigated 330 CRT patients within 1 year after CRT device implantation. The primary endpoint was the composite endpoint of all-cause death or hospitalization for heart failure. RESULTS: Forty-three patients had VA events. These patients had a significantly higher risk of the primary endpoint, even among CRT responders (P = .009). Fast VA compared to slow VA was associated with an increased risk of the primary endpoint (hazard ratio [HR] 2.14; 95% confidence interval [CI] 1.06-4.34; P = .035). Shock therapy was not associated with a primary endpoint (shock therapy vs antitachycardia pacing: HR 1.49; 95% CI 0.73-3.03; P = .269). The patients with VA had a lower prevalence of response to CRT (23 [53%] vs 202 [70%]; P = .031) and longer left ventricular paced conduction time (174 ± 23 ms vs 143 ± 36 ms; P = .003) than the patients without VA. CONCLUSION: VA occurrence within 1 year was related to paced electrical delay and poor response to CRT. VA could be associated with poor prognosis among CRT patients.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Treatment Outcome , Arrhythmias, Cardiac/therapy , Prognosis
12.
Circ J ; 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38057103

ABSTRACT

BACKGROUND: Atrial tachyarrhythmias (ATAs) are reportedly associated with ventricular arrhythmias (VAs). However, little is known about the association between ATA duration and the risk of VA. We investigated the relationship between ATA duration and subsequent VA in patients with a cardiac resynchronization therapy defibrillator (CRT-D).Methods and Results: We investigated associations between the longest ATA duration during the first year after cardiac resynchronization therapy (CRT) implantation and VA and VA relevant to ATA (VAATA) in 160 CRT-D patients. ATAs occurred in 63 patients in the first year. During a median follow-up of 925 days from 1 year after CRT implantation, 40 patients experienced 483 VAs. Kaplan-Meier analysis showed a significantly higher risk of VA in patients with than without ATA in the first year (log rank P=0.0057). Hazard ratios (HR) of VA (HR 2.36, 2.10, and 3.04 for ATA >30s, >6 min and >24 h, respectively) and only VAATA (HR 4.50, 5.59, and 11.79 for ATA >30s, >6 min and >24 h, respectively) increased according to the duration of ATA. In multivariate analysis, ATA >24 h was an independent predictor of subsequent VA (HR 2.42; P=0.02). CONCLUSIONS: Patients with ATA >24 h in the first year after CRT had a higher risk of subsequent VA and VAATA. The risk of VA, including VAATA, increased with the longest ATA duration.

13.
JACC Asia ; 3(5): 755-763, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38094999

ABSTRACT

Background: The prognosis and later fatal arrhythmia in cardiac sarcoidosis (CS) with relatively preserved cardiac function were unclear. Objectives: This study aimed to evaluate the prognosis and arrhythmic events in patients with CS and mildly impaired cardiac function. Methods: Data were collected from a nationwide Japanese cohort survey conducted in 57 hospitals (n = 420); 322 patients with CS with left ventricular ejection fraction (LVEF) >35% were investigated. Results: Ventricular tachycardia (VT) manifestation was present in 50 patients (16%) and absent in 272 (84%), of whom 36 (72%) and 46 (17%), respectively, had an implantable cardioverter-defibrillator (ICD). Over a median of 5 years, 23 all-cause deaths and 31 appropriate ICD discharges were observed. In Kaplan-Meier analysis, all-cause death did not differ between patients with and without VT manifestation (P = 0.660), although appropriate ICD therapy was significantly less used in patients without VT manifestation than in those with VT manifestation (P < 0.001). Of the 272 patients without VT manifestation, 18 had ventricular arrhythmic events (VAEs), including 3 sudden cardiac deaths and 15 appropriate ICD discharges. In multivariate analysis, concomitant nonsustained ventricular tachycardia (NSVT) with atrioventricular block (AVB), lower LVEF, abnormal gallium-67 scintigraphy or 18F-fluorodeoxyglucose positron emission tomography of the heart (Ga/PET), and concomitant NSVT with abnormal Ga/PET at CS diagnosis were independent predictors of VAEs (P = 0.008, P = 0.021, P = 0.049, and P = 0.024, respectively). Conclusions: If concomitant NSVT with AVB, concomitant NSVT with abnormal Ga/PET, or abnormal Ga/PET is observed in patients with CS and mildly impaired cardiac function (LVEF >35%), ICD should be considered as primary prevention.

14.
Article in English | MEDLINE | ID: mdl-37916539

ABSTRACT

OBJECTIVES: With the increasing number of family caregivers due to the ageing population, physical and mental health problems among caregivers are of concern. However, few studies have evaluated their oral health. This study aimed to evaluate the association between being a family caregiver and recent dental visits for dental symptoms in Japan, with consideration of gender. METHODS: A cross-sectional study was conducted using the 2016 Comprehensive Survey of Living Conditions (CSLC) in Japan. Participants with dental symptoms were included in this study. The primary outcome was recent dental visits. The exposure variable of interest was being a primary caregiver for a family member requiring long-term care. A logistic regression analysis was conducted adjusting for contributing factors such as age, gender, marital status, working hours per week, education, household expenditure per month, self-rated health and the interaction between gender and caregiving. A stratified analysis by gender was also performed. RESULTS: Of the 5100 eligible participants, 233 (4.6%) were family caregivers. Of all participants, 2746 (53.8%) reported dental visits. The adjusted odds ratio (aOR) of family caregivers having recent dental visits was 0.83 (95% confidence interval [CI], 0.64-1.09). In a gender stratified analysis, family caregivers were less likely to visit dental clinics than were non-family caregivers in the male subsample (aOR: 0.56, 95% CI: 0.34-0.92) but not in the female subsample (aOR: 0.99, 95% CI: 0.72-1.38). CONCLUSIONS: The findings indicate that family caregivers, especially male caregivers, had fewer dental visits than non-family caregivers. These findings suggest the need to improve the accessibility of dental clinics to family caregivers with dental symptoms.

15.
Int J Cardiol Heart Vasc ; 49: 101282, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37908624

ABSTRACT

Background: Although the dynamic changes of atrial natriuretic peptide (ANP) expressions in a failing heart are well-documented, the clinical implications of detailed measurements of each ANP molecular form processed from proANP remain unclear. Methods: Patients screening was conducted on patients who were eligible for cardiac resynchronization therapy (CRT) between 2014 and 2019 in our institution. Blood samples and echocardiographic parameters were collected on the day before and six months after implantation. Total ANP, proANP, and N-terminal fragment of proANP (NT-proANP) were examined as predictive biomarkers for cardiac death, left ventricular assist device implantation, and heart failure hospitalization following CRT implantation. Results: A total of 86 subjects (mean age 70 years, 64 males) who underwent successful CRT implantation were enrolled. Plasma levels of total ANP, proANP, and NT-proANP were not normally distributed [25.8 pM (interquartile range: 11.1-53.1), 2.2 pM (1.0-5.4), and 4.1 nM (2.4-7.1), respectively]. Over a median follow-up of 2.7 years, 31 patients (2 deaths and 29 heart failure hospitalizations) reached the endpoints. Among the different ANP forms, only NT-proANP emerged as an independent predictor of the composite outcome (adjusted odds ratio of 2.542 in those with levels above vs. below the median, 95 % confidence interval 1.151-5.615, p = 0.021). NT-proANP levels were associated with left atrial volume and left diastolic functional parameters and decreased in response to echocardiographic improvements at six months post-implantation (16 ± 44 % decrease in responders vs 18 ± 60 % increase in non-responders, p = 0.005). Conclusion: Pre-implantation NT-proANP levels could serve as a predictive factor for clinical outcomes in recipients of CRT.

16.
J Arrhythm ; 39(4): 580-585, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37560271

ABSTRACT

Introduction: Cardiac implantable electronic devices are used in patients with cardiac rhythm disorders. Computed tomography irradiation is not prohibited for patients with cardiac implantable electronic devices, despite adverse events being reported. Hence, appropriate preparation and knowledge are required before computed tomography irradiation can be carried out in these patients. Since there is limited knowledge or literature about the influence of computed tomography irradiation in cases with recent cardiac implantable electronic devices, we aimed to evaluate the adverse events and elucidate the necessary and sufficient safety measures associated with this therapy. Methods and Results: We placed cardiac implantable electronic devices on an anthropomorphic phantom model and observed their electrical activity in electrograms, while various protocols of computed tomography irradiation were implemented and adverse events evaluated. Oversensing with pauses of up to 3.2 s was observed in standard computed tomography protocols, but ventricular tachyarrhythmia or other clinically significant events could not be confirmed. Oversensing with pauses of up to 8.0 s was observed and ventricular tachyarrhythmia was detected in the maximum-dose protocols. However, treatments such as antitachycardia pacing or shock therapy for ventricular tachyarrhythmia were not observed because of their absence. Conclusion: Computed tomography irradiation for patients using cardiac implantable electronic devices is highly unlikely to cause clinically significant adverse events with the device settings and computed tomography protocols currently being used. Changing or monitoring the device settings routinely before computed tomography irradiation is not necessarily required for most patients.

17.
J Gerontol A Biol Sci Med Sci ; 78(11): 2170-2175, 2023 10 28.
Article in English | MEDLINE | ID: mdl-37429575

ABSTRACT

BACKGROUND: Pneumonia is a leading cause of death worldwide. It is a particularly serious burden in older people, as they tend to have a weakened immune response. Identifying the role of oral self-care and pneumococcal vaccination in healthy, independent older people can aid pneumonia prevention among them. This study investigated the associations between oral self-care, pneumococcal vaccination, and pneumonia experience among independent older people. METHODS: This cross-sectional study used data from the 2016 Japan Gerontological Evaluation Study. We used machine learning to examine the association between oral self-care and the experience of pneumonia over the previous year, stratified by pneumococcal vaccination. The covariates were sex, age, years of education, equivalent annual income, medical history of stroke, oral health status (choking, dryness, number of teeth), and smoking status. The analysis included 17 217 independent older people aged 65 and over. RESULTS: The prevalence of pneumonia experienced among those who brushed their teeth once or less per day was 4.5% and 5.3% for those with and those without pneumococcal vaccinations, respectively. In the unvaccinated group, the odds ratio of pneumonia experience for those who brushed their teeth once or less a day was 1.57 (95% confidence interval: 1.15-2.14) compared to those who brushed their teeth 3 or more times a day. By contrast, there was no significant association between the frequency of toothbrushing and the experience of pneumonia among people who received pneumococcal vaccination. CONCLUSIONS: Oral care influenced the experience of pneumonia among independent older people who did not receive pneumococcal vaccination.


Subject(s)
Oral Hygiene , Pneumococcal Vaccines , Pneumonia, Pneumococcal , Pneumonia , Aged , Humans , Cross-Sectional Studies , East Asian People , Hospitalization , Machine Learning , Pneumonia/epidemiology , Pneumonia/prevention & control , Pneumonia, Pneumococcal/epidemiology , Pneumonia, Pneumococcal/prevention & control , Self Care , Vaccination , Pneumococcal Vaccines/administration & dosage
18.
Int Dent J ; 73(6): 896-903, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37414691

ABSTRACT

BACKGROUND: This study aimed to provide a stratified description of dental visit utilisation by Japanese residents based on patient age, sex, prefecture, and the purpose of the visits. METHODS: This cross-sectional study used the National Database of Health Insurance Claims of Japan to identify participants visiting dental clinics in Japan (April 2018-March 2019). Dental care utilisation by populations stratified by age, sex, and prefecture was assessed. We estimated the slope index of inequality (SII) and relative index of inequality (RII) to evaluate regional differences based on regional income and education. RESULTS: Amongst the Japanese population, 18.6% utilised preventive dental care visits; 59,709,084 participants visited dental clinics, with children aged 5 to 9 years having the highest proportion. SII and RII were higher for preventive dental visits than those for treatments in all settings. The largest regional differences for preventive care were observed in SII of children aged 5 to 9 years and in RII of men in their 30s and women aged 80 years and older. CONCLUSIONS: This nationwide population-based study revealed that the proportion of people utilising preventive dental care in Japan was low, with regional differences. Preventive care needs to be more easily accessible and available to improve the oral health of residents. The above findings may provide an important basis for improving policies related to dental care for residents.


Subject(s)
Income , Male , Child , Humans , Female , Socioeconomic Factors , Japan , Cross-Sectional Studies , Educational Status
19.
Pacing Clin Electrophysiol ; 46(8): 833-839, 2023 08.
Article in English | MEDLINE | ID: mdl-37485704

ABSTRACT

INTRODUCTION: Infection is one of the most important complications associated with cardiac implantable electronic device (CIED) therapy. The number of reports comparing the outcomes of transvenous lead extraction (TLE), surgical lead extraction, and conservative treatment for CIED infections using a real-world database is limited. This study investigated the association between the treatment strategies for CIED infections and their outcomes. METHODS: We performed a retrospective analysis of 3605 patients with CIED infections admitted to 681 hospitals using a nationwide claim-based database collected between April 2012 and March 2018. RESULTS: We divided the 3605 patients into TLE (n = 938 [26%]), surgical lead extraction (n = 182 [5.0%]), and conservative treatment (n = 2485 [69%]) groups. TLE was performed more frequently in younger patients and at larger hospitals (p for trend < .001 for both). The rate of TLE increased during the study period, whereas that of surgical lead extraction decreased (p for trend < .001 for both). TLE was associated with lower in-hospital mortality (vs. surgical lead extraction: odds ratio [OR], 0.20; 95% CI, 0.06-0.70; vs. conservative treatment: OR, 0.45; 95% CI: 0.22-0.94) and lower 30-day readmission rates (vs. surgical lead extraction: OR, 0.18; 95% CI: 0.06-0.56; vs. conservative treatment: OR, 0.06; 95% CI, 0.03-0.13) in propensity score-weighted analyses. CONCLUSIONS: Only 26% of patients hospitalized for CIED infections received TLE. TLE was associated with significantly lower in-hospital mortality and 30-day recurrence rates than surgical lead extraction and conservative treatment, suggesting that TLE should be more widely recommended as a first-line treatment for CIED infections.


Subject(s)
Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Conservative Treatment , Retrospective Studies , Propensity Score , Device Removal , Treatment Outcome
20.
Heart Rhythm ; 20(9): 1289-1296, 2023 09.
Article in English | MEDLINE | ID: mdl-37307884

ABSTRACT

BACKGROUND: High percent ventricular pacing maximizes cardiac resynchronization therapy (CRT) response. An effective CRT algorithm classifies each left ventricular (LV) pace as effective or ineffective on the basis of the detection of QS or QS-r morphology on the electrogram; however, the relationship between percent effective CRT pacing (%e-CRT) and responses is unclear. OBJECTIVE: We aimed to clarify the association between %e-CRT and clinical outcomes. METHODS: Of the 136 consecutive CRT patients, 49 using the adaptive and effective CRT algorithm with percent ventricular pacing > 90% were evaluated. The primary and secondary outcomes were heart failure (HF) hospitalization and prevalence of CRT responders, defined as patients with an improvement in LV ejection fraction of ≥10% or a reduction in LV end-systolic volume of ≥15% after CRT device implantation, respectively. RESULTS: We divided the patients into the effective group (n = 25) and the less effective group (n = 24) by the median value of %e-CRT (97.4% [93.7%-98.3%]). During the median follow-up period of 507 days (interquartile range 335-730 days), the effective group had a significantly lower risk of HF hospitalization than the less effective group as revealed by Kaplan-Meier analysis (log-rank, P = .016). Univariate analysis revealed %e-CRT ≥ 97.4% (hazard ratio 0.12; 95% confidence interval 0.01-0.95; P = .045) as a predictor of HF hospitalization. The effective group had a higher prevalence of CRT responders than the less effective group (23 [92%] vs 9 [38%]; P < .001). Univariate analysis revealed that %e-CRT ≥ 97.4% (odds ratio 19.20; 95% confidence interval 3.63-101.00; P < .001) was a predictor of CRT response. CONCLUSION: High %e-CRT is associated with high CRT responder prevalence and low HF hospitalization risk.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Treatment Outcome , Cardiac Resynchronization Therapy Devices , Heart Failure/diagnosis , Heart Failure/therapy , Algorithms