1.
J Cardiovasc Med (Hagerstown) ; 22(6): 492-495, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33136814

ABSTRACT

AIMS: A greater number of patients with bicuspid aortic valves (BAV) may be identified and treated as indications for transcatheter aortic valve implantation (TAVI) are expected to expand to younger patients. We evaluated the contemporary frequency and management of symptomatic patients with stenotic BAV in a multicenter European registry. METHODS: Between November 2017 and February 2018, all consecutive patients admitted for symptomatic aortic stenosis across six high-volume European hospitals were prospectively enrolled in the BiTri registry. RESULTS: Of the 832 patients, 17% (n = 138) had a BAV. The most frequent BAV phenotypes were type 1 (left--right coronary cusps fusion 64%) and type 1 (right-noncoronary cusps fusion 17%). Type 0 and type 2 accounted for 12 and 2%, respectively. When compared with tricuspid patients (n = 694), BAV patients were younger, with lower surgical risk. The transthoracic echocardiography (TTE) identified BAV in 64% of patients. Multisliced computed tomography (MSCT) additionally completed the diagnosis in 20% of patients. Surgical inspection finally identified the remaining undiagnosed 16% of BAV. A combination of TTE and MSCT was the most common diagnosis method for BAV. Surgical aortic valve replacement (SAVR) was the predominant therapeutic option for BAV (70%) whilst TAVI was performed in 26%. CONCLUSION: BAV is frequently observed in symptomatic patients with aortic stenosis. These patients are younger, have a lower risk profile and are predominantly treated with SAVR as compared with tricuspid patients. However, TAVI is performed in almost one-third of BAV patients in contemporary European practice. TTE combined with MSCT identified 84% of BAV.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis Implantation/methods , Multimodal Imaging/methods , Aged , Aortic Valve/pathology , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Bicuspid Aortic Valve Disease/diagnosis , Bicuspid Aortic Valve Disease/physiopathology , Echocardiography/methods , Europe/epidemiology , Female , Humans , Male , Multidetector Computed Tomography/methods , Registries , Risk Adjustment/methods , Risk Factors , Severity of Illness Index , Transcatheter Aortic Valve Replacement/methods
2.
Circ Cardiovasc Interv ; 12(1): e007107, 2019 01.
Article in English | MEDLINE | ID: mdl-30626202

ABSTRACT

BACKGROUND: Sizing for transcatheter aortic valve implantation in bicuspid aortic valves (BAV) remains controversial. METHODS AND RESULTS: The aim of the BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) retrospective registry is to capture the sizing ratios used for transcatheter aortic valve implantation in BAV and analyze the second-generation prostheses geometry postimplantation. About 101 patients with BAV along with available pre- and post-transcatheter aortic valve implantation multidetector computed tomography were compared with 88 tricuspid aortic valves (TAV) patients. Preprocedural multidetector computed tomography diagnosed type 0 and type 1 BAV in, respectively, 12.9% and 86.1 % of BAV. At baseline, the ellipticity index was similar between BAV and TAV patients: 1.2±0.1 versus 1.2±0.1, P=0.09. The mean annular oversizing was, respectively, 1.14±0.04 and 1.04±0.04, P<0.001, in TAV and BAV patients. The mean prosthesis intercommissural distance, ratio was 1.03±0.1. The mean diameter of the prostheses at the annulus matched the mean perimeter-derived diameter of the aortic annulus at baseline with TAV (23.3±2.2 versus 23.6±1.9, P=0.4) and was smaller with BAV (24±2.8 versus 26.8±3.1, P<0.01), confirming 11% underexpansion in BAV. Finally, in situ, prosthesis diameter and ellipticity followed the same pattern, with stable values from the distal edge to 12 mm above, in both groups. CONCLUSIONS: Second-generation prostheses similarly reshape the aortic annulus in TAV and BAV. Prostheses keep consistent diameters from distal edge to 12 mm in TAV and BAV. Prosthesis underexpansion is constantly observed in BAV. Annular-based sizing is accurate in BAV with minimal oversizing. The intercommissural distance, 4 mm above the annulus, could be integrated in gray zones. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03495050.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/abnormalities , Heart Valve Diseases/complications , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/physiopathology , Bicuspid Aortic Valve Disease , Europe , Female , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Humans , Israel , Male , Multidetector Computed Tomography , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome