Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters








Database
Language
Publication year range
1.
Minerva Anestesiol ; 87(3): 319-324, 2021 03.
Article in English | MEDLINE | ID: mdl-32755090

ABSTRACT

BACKGROUND: Patient-ventilator asynchronies are challenging during pediatric mechanical ventilation. We hypothesized that monitoring the electrical activity of the diaphragm (EAdi) together with the "standard" airway opening pressure (Pao) and flow-time waveforms during pressure support ventilation would improve the ability of a cohort of critical care physicians to detect asynchronies in ventilated children. METHODS: We recorded the flow, Pao and EAdi waveforms in ten consecutive patients. The recordings were split in periods of 15 s, each reproducing a ventilator screenshot. From this pool, a team of four experts selected the most representative screenshots including at least one of the three most common asynchronies (missed efforts, auto-triggering and double triggering) and split them into two versions, respectively showing or not the EAdi waveforms. The screenshots were shown in random order in a questionnaire to sixty experienced pediatric intensivists that were asked to identify any episode of patient-ventilator asynchrony. RESULTS: Among the ten patients included in the study, only eight had EAdi tracings without artifacts and were analyzed. When the Eadi waveform was shown, the auto-triggering detection improved from 13% to 67% (P<0.0001) and the missed efforts detection improved from 43% to 95% (P<0.0001). The detection of double triggering, instead, did not improve (85% with the EAdi vs. 78% without the EAdi waveform; P=0.52). CONCLUSIONS: This single center study suggests that the EAdi waveform may improve the ability of pediatric intensivists to detect missed efforts and auto-triggering asynchronies. Further studies are required to determine the clinical implications of these findings.


Subject(s)
Diaphragm , Physicians , Child , Critical Care , Diaphragm/diagnostic imaging , Humans , Respiration, Artificial , Ventilators, Mechanical
3.
Perfusion ; 33(7): 553-561, 2018 10.
Article in English | MEDLINE | ID: mdl-29792775

ABSTRACT

This review summarizes the European rules to control the market when introducing new products. In particular, it shows all the steps to achieve the European Conformity (CE Mark), a certification that all new medical products must achieve before being used in Europe. Extracorporeal membrane oxygenation (ECMO) devices are exposed to the same procedures. Hereby, we present some regulatory issues regarding pumps and oxygenators, providing technical details as released by the manufacturers on their websites and information charts.


Subject(s)
Extracorporeal Membrane Oxygenation/methods , Heart-Assist Devices/standards , Europe , Humans
4.
Perfusion ; 33(1_suppl): 24-30, 2018 05.
Article in English | MEDLINE | ID: mdl-29788844

ABSTRACT

INTRODUCTION: Neonatal and pediatric ECMO is a high-risk procedure that should be performed only in expert centers. Children who are eligible for ECMO and are managed in hospitals without ECMO capabilities should be referred to the closest ECMO center before the severity of illness precludes safe conventional transport. When the clinical situation precludes safe conventional transport, ECMO should be provided on site with the patient transported on ECMO. METHODS: We retrospectively reviewed our institutional database of all ECMO transports for neonatal and pediatric respiratory failure from February 2013 to February 2018. RESULTS: Over the last 5 years, we provided 24 transports covering all requests from the center and south of Italy except for the islands. Of these transports, 20 were performed on ECMO and 4 without ECMO. No patient died during transportation. Five complications were reported only during the ECMO transports, and all of these were managed without compromising the patient's safety. The preferred modes of transport were by ambulance (70%) and ambulance transported into the fixed wing aircraft (30%) for longer national distances. The survival to hospital discharge of the patients transported with ECMO was 75% among the neonatal transports and 83.3% among the pediatric transports. The survival to hospital discharge of the four patients transported without ECMO was 100% for both neonates and children. CONCLUSIONS: Neonatal and pediatric ECMO transports can be safely performed with a dedicated team that maintains stringent adherence to well-designed management protocols.


Subject(s)
Extracorporeal Membrane Oxygenation/methods , Transportation of Patients/methods , Aircraft , Ambulances , Female , Humans , Infant , Infant, Newborn , Italy , Male , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL