Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
2.
Semergen ; 43(6): 437-444, 2017 Sep.
Article in Spanish | MEDLINE | ID: mdl-27773623

ABSTRACT

INTRODUCTION: Knowing the most common microorganisms in our environment can help us to make proper empirical treatment decisions. The aim is to identify those microorganisms causing community-acquired pneumonia. PATIENTS AND METHODS: An observational, descriptive and prospective study was conducted, including patients over 14 years with a clinical and radiographic diagnosis of community-acquired pneumonia during a 383 consecutive day period. A record was made of sociodemographic variables, personal history, prognostic severity scales, progress, and pathogenic agents. The aetiological diagnosis was made using blood cultures, detection of Streptococcus pneumoniae and Legionella pneumophila urinary antigens, sputum culture, influenza virus and Streptococcus pyogenes detection. Categorical variables are presented as absolute values and percentages, and continuous variables as their means and standard deviations. RESULTS: Of the 287 patients included in the study (42% women, mean age 66±22 years), 10.45% died and 70% required hospital admission. An aetiological diagnosis was achieved in 43 patients (14.98%), with 16 microorganisms found in 59 positive samples. The most frequently isolated pathogen was Streptococcus pneumonia (24/59, 41%), followed by gram-negative enteric bacilli, Klebsiella pneumonia, Escherichia coli, Serratia marcescens and Enterobacter cloacae isolated in 20% of the samples (12/59), influenza virus (5/59, 9%), methicillin-resistant Staphylococcus aureus (3/59, 5%), Pseudomonas aeruginosa (2/59, 3%), Moraxella catarrhalis (2/59, 3%), Legionella pneumophila (2/59, 3%), and Haemophilus influenza (2/59, 3%). Polymicrobial infections accounted for 14% (8/59). CONCLUSION: A high percentage of atypical microorganisms causing community-acquired pneumonia were found.


Subject(s)
Community-Acquired Infections/epidemiology , Hospitalization/statistics & numerical data , Pneumonia, Bacterial/epidemiology , Pneumonia, Viral/epidemiology , Adult , Aged , Community-Acquired Infections/diagnosis , Community-Acquired Infections/microbiology , Female , Humans , Incidence , Male , Middle Aged , Pneumonia, Bacterial/diagnosis , Pneumonia, Bacterial/microbiology , Pneumonia, Viral/diagnosis , Pneumonia, Viral/microbiology , Prospective Studies
4.
Antimicrob Agents Chemother ; 45(9): 2460-7, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11502515

ABSTRACT

A continuous infusion of vancomycin (CIV) may provide an alternative mode of infusion in severe hospital-acquired methicillin-resistant staphylococcal (MRS) infections. A multicenter, prospective, randomized study was designed to compare CIV (targeted plateau drug serum concentrations of 20 to 25 mg/liter) and intermittent infusions of vancomycin (IIV; targeted trough drug serum concentrations of 10 to 15 mg/liter) in 119 critically ill patients with MRS infections (bacteremic infections, 35%; pneumonia, 45%). Microbiological and clinical outcomes, safety, pharmacokinetics, ease of treatment adjustment, and cost were compared. Microbiological and clinical outcomes and safety were similar. CIV patients reached the targeted concentrations faster (36 +/- 31 versus 51 +/- 39 h, P = 0.029) and fewer samples were required for treatment monitoring than with IIV patients (7.7 +/- 2.2 versus 11.8 +/- 3.9 per treatment, P < 0.0001). The variability between patients in both the area under the serum concentration-time curve (AUC(24h)) and the daily dose given over 10 days of treatment was lower with CIV than with IIV (variances, 14,621 versus 53,975 mg(2)/liter(2)/h(2) [P = 0.026] and 414 versus 818 g(2) [P = 0.057], respectively). The 10-day treatment cost per patient was $454 +/- 137 in the IIV group and was 23% lower in the CIV group ($321 +/- 81: P < 0.0001). In summary, for comparable efficacy and tolerance, CIV may be a cost-effective alternative to IIV.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Staphylococcal Infections/drug therapy , Vancomycin/therapeutic use , Adult , Aged , Aminoglycosides , Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/adverse effects , Anti-Bacterial Agents/economics , Anti-Bacterial Agents/pharmacokinetics , Cost-Benefit Analysis , Female , Humans , Infusions, Intravenous , Male , Middle Aged , Prospective Studies , Staphylococcal Infections/economics , Staphylococcal Infections/metabolism , Treatment Outcome , Vancomycin/administration & dosage , Vancomycin/adverse effects , Vancomycin/economics , Vancomycin/pharmacokinetics
6.
Crit Care Med ; 28(3): 665-71, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10752812

ABSTRACT

OBJECTIVE: To determine whether three hydrophobic and hygroscopic heat and moisture exchangers (HMEs) retain their heating and humidifying properties (assessed by psychrometric measurements of absolute humidity, relative humidity, and tracheal temperature) for 48 hrs without any drop in their bacteriologic efficiency. DESIGN: Prospective randomized clinical trial. PATIENTS: Sixty-one consecutive unselected mechanically ventilated intensive care unit patients. INTERVENTIONS: Patients were randomly allocated to one of the three HMEs studied (Hygrobac-Dar from Mallinckrodt, n = 21; Humid-Vent from Gibeck, n = 20; and Clear-Thermal from Intersurgical, n = 20). MEASUREMENTS AND MAIN RESULTS: Hygrometric parameters were measured by psychrometry after 3, 24, and 48 hrs of use. Peak airway pressure was recorded every 6 hrs and averaged over 24 hrs. Bacterial colonization of both patients and circuits was studied. Patients in all three groups were similar in terms of age, indications for, and overall duration of mechanical ventilation. Tracheal tube occlusion never occurred. Hygrometric data included 371 measurements whereas bacteriologic data included >700 samples and cultures. The Hygrobac-Dar HMEs gave a significantly higher absolute humidity whatever the time of measurement (3, 24, or 48 hrs) than the other two HMEs (p < .001). The Clear-Thermal HMEs gave the poorest hygrometric parameters (p < .01); five of them were replaced prematurely (24 hrs) because the absolute humidity was <25 mg H2O/L. This did not occur for the other HMEs. Mean peak airway pressures were identical in the three groups. The bacterial colonizations of both patient and circuit were similar (and negligible for circuits) for all three groups. CONCLUSION: Some HMEs may be used safely for 48 hrs without change. However, this does not pertain to every brand of HME. Objective in vivo evaluation of their humidifying performances is decisive before extending their duration of use.


Subject(s)
Respiration, Artificial/instrumentation , Technology Assessment, Biomedical , Acute Disease , Analysis of Variance , Colony Count, Microbial , Cost-Benefit Analysis , Equipment Safety , Female , Filtration , Humans , Humidity , Lung Diseases, Obstructive/therapy , Male , Middle Aged , Prospective Studies , Respiration, Artificial/economics , Respiratory Insufficiency/therapy , Time Factors , Wettability
7.
Chest ; 115(6): 1646-52, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10378563

ABSTRACT

STUDY OBJECTIVE: To determine the correlation between simple rating of condensation seen in the flex-tube connecting the heating and humidifying device used with the endotracheal tube and hygrometric parameters (absolute and relative humidity and tracheal temperature) measured by psychrometry. DESIGN: Prospective randomized clinical trial. SETTING: Medical ICU of Louis Mourier Hospital, Colombes, France, a university-affiliated teaching hospital. PATIENTS: Forty-five consecutive mechanically ventilated critically ill patients. INTERVENTIONS: Patients undergoing mechanical ventilation were randomly assigned to receive humidification with one of the four heat and moisture exchangers (HMEs) tested or with a conventional heated humidifier. MEASUREMENTS: The hygrometric performances of four HMEs (BB2215, BB50, and BB100 from Pall Biomedical, Saint-Germaine-en-Laye, France; and Hygrobac-Dar from Mallinckrodt, Mirandola, Italy) and a heated humidifier (Fisher & Paykel; Auckland, New Zealand) were studied after 3 h and also after 48 h of use for the Hygrobac-Dar and correlated to a clinical visual inspection rating the amount of condensation in the flex-tube of the endotracheal tube. RESULTS: A total of 95 measurements in 45 patients were performed. The best hygrometric parameters were obtained with the heated humidifier (p < 0.001). The Hygrobac-Dar yielded significantly higher values for both humidities and tracheal temperature than the other three HMEs (p < 0.001). The performance of Hygrobac-Dar was unchanged after 48 h of use. There was a significant correlation between the condensation seen in the flex-tube and the hygrometric parameters measured by psychrometry (absolute humidity, rho = 0.7; relative humidity, rho = 0.7; tracheal temperature, rho = 0.5, p < 0.0001). CONCLUSION: In mechanically ventilated ICU patients, visual evaluation of the condensation in the flex-tube provides an estimation of the heating and humidifying efficacy of the heating and humidifying device used, thus allowing the clinician bedside monitoring of airway humidification.


Subject(s)
Humidity , Point-of-Care Systems , Respiration, Artificial/methods , Respiratory Insufficiency/therapy , Acute Disease , Body Temperature , Critical Illness , Hot Temperature , Humans , Intensive Care Units , Intubation, Intratracheal , Middle Aged , Observer Variation , Prospective Studies , Respiration, Artificial/standards , Trachea/physiology
8.
Intensive Care Med ; 23(7): 753-9, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9290989

ABSTRACT

OBJECTIVE: The determination of basal cardiac output (CO) and of its variations during different therapeutic interventions liable to increase or decrease it in mechanically ventilated patients using transesophageal echocardiography (TEE). DESIGN: To compare CO measurements simultaneously obtained by transmitral single-plane TEE and thermodilution. SETTING: Medical intensive care unit. PATIENTS: Twenty-two consecutive mechanically ventilated patients hospitalized for various medical conditions were included. INTERVENTIONS: The comparisons between transmitral single-plane TEE and thermodilution measurements were made at baseline and after different therapeutic interventions affecting CO (fluids or dobutamine infusion or positive end-expiratory pressure titration). MEASUREMENTS: Seventy-four measurements were obtained. Cardiac output using TEE was the product of the mitral valve area, the time-velocity integral of flow at the same site and the heart rate. RESULTS: A significant correlation was observed between thermodilution and TEE measurements of CO (n = 74, r = 0.78, p < 0.001) despite wide limits of agreement (mean +/- 2SD = -0.3 +/- 3.1 l/min). Thermodilution and TEE CO determinations both had significant inverse correlation with the arterial-venous oxygen content difference in ten consecutive patients (r = 0.77, p < 0.01 and r = 0.71, p < 0.01, respectively). The correlation between variations of CO greater than 20% obtained by thermodilution and TEE was significant (r = 0.89, p < 0.001). The operative characteristics implied the ability of TEE to predict significant variations of thermodilution CO (sensitivity 85% and negative predictive values 86%). Moreover, arterial-venous oxygen content difference changes of 5% or more were better detected using TEE than thermodilution. CONCLUSIONS: These results suggest that although transesophageal CO measurements cannot replace thermodilution ones, the determination of CO variations obtained using TEE may be useful in the management of critically ill mechanically ventilated patients. This technique may make it possible to monitor hemodynamics during initial therapeutic interventions in those patients in whom right heart catheterization cannot be performed immediately.


Subject(s)
Cardiac Output , Echocardiography, Transesophageal/standards , Respiration, Artificial , Thermodilution/standards , Adult , Aged , Aged, 80 and over , Blood Flow Velocity , Blood Gas Analysis , Female , Heart Rate , Humans , Male , Middle Aged , Monitoring, Physiologic , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Time Factors
9.
Chest ; 110(5): 1294-8, 1996 Nov.
Article in English | MEDLINE | ID: mdl-8915237

ABSTRACT

Heat and moisture exchangers (HME) are increasingly used to warm and humidify inspired gases in intubated ventilated patients. But these devices add dead space that may alter the alveolar ventilation. This could impair the efficiency of spontaneous ventilation (SV) during weaning trials from mechanical ventilation. Fifteen patients were tested with an HME (Hygrobac-DAR) and a heated humidifier (HH) (Fischer-Paykel MR 450) in a random order during weaning trials in SV with inspiratory pressure support. Minute ventilation VE, tidal volume), and respiratory rate were recorded and arterial blood was sampled for blood gas analysis with each device. The HME gave a significantly greater VE than the HH (9.3 +/- 0.8 L/min vs 8.1 +/- 0.8 L/min; p < 0.005), because of increased respiratory rate (21 +/- 2/min vs 19 +/- 2/min; p < 0.05). Tidal volume was unchanged for HME and HH (470 +/- 32 mL vs 458 +/- 39 mL). The higher PaCO2 with HME than with HH (44 +/- 2 mm Hg vs 42 +/- 2 mm Hg; p < 0.005) revealed an insufficient alveolar ventilation response to the increase in dead space. Arterial Po2 rose with the HME, but not significantly above the HH values (103 +/- 6 mm Hg vs 97 +/- 6 mm Hg; p = 0.055), possibly because of a positive end-expiratory pressure effect of the HME. The need to increase VE in SV when an HME is used should be taken into account during difficult weaning from mechanical ventilation.


Subject(s)
Pulmonary Gas Exchange , Respiration , Ventilator Weaning , Ventilators, Mechanical , Adult , Aged , Aged, 80 and over , Carbon Dioxide/blood , Equipment Design , Female , Hot Temperature , Humans , Humidity , Inhalation , Intubation, Intratracheal , Male , Middle Aged , Oxygen/blood , Positive-Pressure Respiration , Pulmonary Alveoli/physiopathology , Respiration, Artificial , Respiratory Dead Space , Tidal Volume , Water
10.
Am J Respir Crit Care Med ; 152(5 Pt 1): 1562-9, 1995 Nov.
Article in English | MEDLINE | ID: mdl-7582295

ABSTRACT

Heat and moisture exchangers (HME) (Dar-Hygrobac II, Peters) can safely be used every 24 h for long-term mechanical ventilation and provide a cost-saving alternative to heated humidifiers. We have prospectively determined whether changing HMEs every 48 h only affects their clinical and bacteriological efficiency in a series of consecutive nonselected ICU patients requiring long-term mechanical ventilation. Two consecutive periods were compared. During period 1, HMEs were replaced every day; during period 2, they were changed every 48 h. Patients from the two periods were similar in terms of age and indication for and overall duration of MV (10 +/- 8.6 versus 10 +/- 9 d, p = 0.9). Minute ventilation and maximum values for peak airway pressure were identical during the two periods. These values were also identical after 1 and 2 d of HME use during period 2, indicating that HME resistance was not increased by prolonged use. Obstruction of the tracheal tube occurred only once in a period 1 patient. The results of quantitative cultures indicate that the maximum and mean levels of bacterial colonization during the two periods were similar for the pharynx, trachea, Y-connector, patient, and ventilator side of the HME. More importantly, the incidence of nosocomial pneumonia was similar during the two periods (6/61 versus 8/68, p = 0.7). Thus, prolonged HME use is safe and provides a substantial reduction in the cost of mechanical ventilation.


Subject(s)
Cross Infection/prevention & control , Pneumonia, Bacterial/prevention & control , Respiration, Artificial/instrumentation , Adult , Aged , Cost-Benefit Analysis , Cross Infection/diagnosis , Cross Infection/epidemiology , Cross Infection/microbiology , Equipment Contamination/prevention & control , Equipment Contamination/statistics & numerical data , Evaluation Studies as Topic , Female , Humans , Incidence , Male , Middle Aged , Pneumonia, Bacterial/diagnosis , Pneumonia, Bacterial/epidemiology , Pneumonia, Bacterial/microbiology , Prospective Studies , Respiration, Artificial/economics , Respiration, Artificial/statistics & numerical data , Safety , Time Factors
11.
Am J Respir Crit Care Med ; 151(4): 986-92, 1995 Apr.
Article in English | MEDLINE | ID: mdl-7697277

ABSTRACT

The contribution of ventilator circuit bacterial contamination to the occurrence of ventilator-associated pneumonia remains controversial. In a previous study, we found that the incidence of pneumonia was identical with ventilator circuit changes every 48 h and with no ventilator circuit changes. The present study prospectively assessed whether keeping ventilator circuits clean with a heat and moisture exchanger exhibiting antimicrobial barrier properties affects patient colonization and the incidence of nosocomial pneumonia in patients receiving mechanical ventilation for more than 48 h. Consecutive patients were randomly allocated to humidification with either a heat and moisture exchanger (Group 1, n = 61) or a heated humidifier (Group 2, n = 70). In both groups, no circuit changes were performed throughout ventilatory support. Duration of mechanical ventilation was identical in both groups (10 +/- 8.6 d (range: 2 to 47) in Group 1 and 12.5 +/- 14.2 d [range: 2 to 85] in Group 2). The incidence of pneumonia (positive quantitative culture of protected brush specimen) was similar in both groups (6/61 and 8/70 in Groups 1 and 2, respectively; p = 0.8), as was duration of ventilation prior to pneumonia (9 +/- 5.9 versus 8.2 +/- 5.7 d; p = 0.8). Ventilator tubing contamination was considerably reduced with the use of a heat and moisture exchanger. In contrast, bacterial colonization of the pharynx and trachea was identical in both groups. These results suggest that circuit colonization plays little or no role in the occurrence of ventilator-associated pneumonia, provided usual maintenance precautions are applied.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Cross Infection/etiology , Equipment Contamination , Pneumonia, Bacterial/etiology , Respiration, Artificial/instrumentation , Adult , Aged , Critical Care , Cross Infection/epidemiology , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Female , Hot Temperature , Humans , Humidity , Incidence , Male , Middle Aged , Pneumonia, Bacterial/epidemiology , Pneumonia, Bacterial/prevention & control , Prospective Studies
13.
Am Rev Respir Dis ; 147(4): 946-51, 1993 Apr.
Article in English | MEDLINE | ID: mdl-8466131

ABSTRACT

In patients with clinical suspicion of pneumonia, quantitative cultures of protected brushing specimens (PBS) yielding > or = 10(3) CFU/ml of at least one microorganism have been found useful for differentiating airway colonization and lung infection, especially in mechanically ventilated patients. The amount of secretions collected by protected catheter brushing is small and difficult to determine accurately. Thus, the clinical significance of PBS cultures yielding organisms in concentrations > or = 10(2) but < 10(3) CFU/ml, in the absence of active antimicrobial treatment, is unknown. The 34 consecutive results of PBS cultures yielding organisms in concentrations > or = 10(2) but < 10(3) CFU/ml in 30 patients under mechanical ventilation or weaned for < or = 4 days were prospectively studied. No patients were receiving agents active on the organism recovered. In 5 cases, the diagnosis of pneumonia was ruled out by recovery without treatment (n = 4) or negative postmortem lung cultures (n = 1). A second PBS was cultured in 29 episodes (2.7 +/- 1.8 days after the first PBS). In 12 instances (Group 1), cultures of the second PBS yielded > or = 10(3) CFU/ml of the same organism as that found in the first PBS (S. pneumoniae, 1; S. aureus, 1; H. influenzae, 1; E. coli, 1; P. aeruginosa, 4; and A. baumannii, 4), and these patients were therefore treated with appropriate antibiotics. A total of 17 patients had a negative repeat PBS culture (no growth or trivial concentrations) and were considered free of pneumonia and given no antibiotic treatment for this episode.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Bacteriological Techniques/instrumentation , Pneumonia/microbiology , Specimen Handling/instrumentation , Bacteria/growth & development , Colony Count, Microbial , Female , Humans , Male , Middle Aged , Pneumonia/diagnosis , Prospective Studies , Respiration, Artificial
14.
Chest ; 103(2): 383-5, 1993 Feb.
Article in English | MEDLINE | ID: mdl-8432123

ABSTRACT

To test the hypothesis that the use of protected specimen brushing (PSB) via flexible bronchoscopy does not predispose to bacteremia in ICU patients, we prospectively performed aerobic and anaerobic blood cultures immediately following bronchoscopy with PSB. A total of 123 episodes in 68 consecutive patients with suspected pneumonia were analyzed. Blood cultures were negative in 110 cases (89 percent) and positive in 13 cases (11 percent) (p < 0.001). Twelve of these 13 patients with positive blood cultures had quantitative PSB specimen cultures showing nonsignificant growth (< 10(3) CFU/ml). In nine patients, the bacteria recovered from blood cultures (coagulase-negative staphylococci or sarcina) were considered nonpathogenic according to conventional criteria. Blood cultures grew a Staphylococcus aureus in two patients with previously documented staphylococcal septicemia. In one patient with no identifiable site of infection, the blood culture yielded Enterococcus faecalis. The only patient with both a positive blood culture and PSB culture results indicating pneumonia had different organisms recovered from the two samples. Blood cultures taken after PSB in the 17 other episodes of pneumonia (PSB specimen cultures > or = 10(3) CFU/ml) were negative. At the time of brushing and blood sampling for culture, none of these patients was receiving antibiotics active on the organisms found. In conclusion, the incidence of bacteremia after PSB in ICU patients seems very low even in patients with documented pneumonia. Substantial savings would result from not performing routine blood cultures after PSB.


Subject(s)
Bacteremia/etiology , Bronchi/microbiology , Bronchoscopy/adverse effects , Intensive Care Units , Pneumonia/diagnosis , Specimen Handling/adverse effects , Aged , Bacteremia/diagnosis , Bacteria/isolation & purification , Female , Humans , Male , Middle Aged , Prospective Studies
16.
Intensive Care Med ; 19(5): 279-84, 1993.
Article in English | MEDLINE | ID: mdl-8408937

ABSTRACT

OBJECTIVE: To evaluate the bacteriology of early aspiration pneumonia using a protected specimen brush and quantitative culture techniques, and whether penicillin G is adequate as initial treatment pending culture results. PATIENTS AND METHODS: 52 patients (of which 45 required mechanical ventilation) meeting usual clinical criteria for aspiration pneumonia were prospectively included. On admission, patients were given intravenous penicillin G and a protected specimen brush was performed < or = 48 h after. RESULTS: Cultures of the brush were negative (< 10(3) CFU/ml) in 33 patients (1 had blood cultures positive with S. pneumoniae) and positive (> or = 10(3) CFU/ml) for S. pneumoniae in 2 patients. Seventeen patients had a positive culture (> or = 10(3) CFU/ml) for at least one penicillin G resistant microorganism, with a total of 20 organisms (S. aureus: 6; H. influenzae: 2; Enterobacteriaceae: 8; P. aeruginosa: 3; C. albicans: 1). In 4 of these patients, a penicillin-sensitive pathogen was also recovered in significant concentrations (S. pneumoniae: 2; Streptococcus sp.: 2). These 17 patients with a resistant pathogen did not differ from the 35 other patients with respect to need for ventilatory support and mortality rate. By contrast, they were older (61.1 +/- 21.9 vs. 42.9 +/- 18.8 years; p < 0.005) and required longer mechanical ventilation (6.1 +/- 4.6 vs. 3.5 +/- 2.7 days; p < 0.03) and hospitalization (11.2 +/- 8.8 vs. 6.7 +/- 4.7 days; p < 0.02). Of 17 patients 12 with penicillin G resistant organisms versus 0/35 without, were in-hospital patients and/or had a digestive disorder (p < 0.001). CONCLUSION: The broad range of offending organisms seen in early aspiration pneumonia precludes use of any single empiric regimen, making protected specimen brush mandatory in many patients. Nevertheless, the involvement of S.pneumoniae in a notable proportion of our patients suggests that routine penicillin prophylaxis after early aspiration (at least in most patients with community-acquired aspiration) is warranted given the potential severity of pneumococcal sepsis in such patients.


Subject(s)
Bronchoscopes , Community-Acquired Infections/drug therapy , Community-Acquired Infections/microbiology , Cross Infection/drug therapy , Cross Infection/microbiology , Penicillin G/therapeutic use , Pneumonia, Aspiration/drug therapy , Pneumonia, Aspiration/microbiology , Specimen Handling/instrumentation , Adult , Age Factors , Aged , Asepsis/instrumentation , Community-Acquired Infections/diagnosis , Community-Acquired Infections/epidemiology , Comorbidity , Cross Infection/diagnosis , Cross Infection/epidemiology , Digestive System Diseases/epidemiology , Drug Resistance, Microbial , Female , Hospital Mortality , Humans , Infusions, Intravenous , Length of Stay/statistics & numerical data , Male , Middle Aged , Penicillin G/pharmacology , Pneumonia, Aspiration/diagnosis , Pneumonia, Aspiration/epidemiology , Prognosis , Prospective Studies , Respiration, Artificial/statistics & numerical data
17.
Am Rev Respir Dis ; 146(2): 295-9, 1992 Aug.
Article in English | MEDLINE | ID: mdl-1489115

ABSTRACT

The management of patients with unilateral pneumonia and severe hypoxemia often represents a therapeutic challenge. Mechanical ventilation with the diseased lung uppermost may improve gas exchange, but it is not devoid of adverse effects. No hemodynamic measurements have been reported in patients ventilated in this manner; therefore, whether or not the improvement in PaO2 is counterbalanced by hemodynamic deterioration remains unknown. Almitrine bismesylate is a drug that seems able to improve gas exchange in patients with chronic obstructive pulmonary disease or the adult respiratory distress syndrome. The increase in PaO2 after its administration has been attributed to an improvement in ventilation-perfusion relationships. Its use has never been reported during unilateral pneumonia with severe hypoxemia. We therefore compared its effects with those of lateral position in eight consecutive mechanically ventilated patients with unilateral pneumonia. Blood gas and hemodynamic measurements were performed both at maintenance FIO2 and at an FIO2 of 1.0. Almitrine (1 mg/kg over 1 h) had no effect on PaO2 under either FIO2 condition. Cardiac output remained unchanged, but mean pulmonary artery pressure increased from 22.5 +/- 1.2 to 26.5 +/- 1.3 mm Hg (p < 0.02). By contrast, lateral position had striking effects on PaO2, which increased from 100 +/- 14 mm Hg in supine position to 156 +/- 23 mm Hg (p < 0.01) when the abnormal lung was placed uppermost at maintenance FIO2 and from 207 +/- 21 (supine) to 300 +/- 28 mm Hg (lateral) (p < 0.01) at FIO2 1.0.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Almitrine/therapeutic use , Bacterial Infections/therapy , Hypoxia/therapy , Pneumonia/therapy , Posture , Adult , Almitrine/administration & dosage , Almitrine/pharmacology , Bacterial Infections/complications , Bacterial Infections/physiopathology , Blood Gas Analysis , Female , Hemodynamics/drug effects , Humans , Hypoxia/etiology , Hypoxia/physiopathology , Male , Middle Aged , Oximetry , Pneumonia/complications , Pneumonia/physiopathology , Prospective Studies , Pulmonary Gas Exchange/drug effects , Ventilation-Perfusion Ratio/drug effects
18.
J Surg Res ; 47(2): 149-54, 1989 Aug.
Article in English | MEDLINE | ID: mdl-2755118

ABSTRACT

Depolarization of the plasma membrane and increased sodium influx have both been suggested as mitogenic signals. Following bowel resection the intestinal suture line has been reported a fertile site for tumor recurrence. Whether alterations in cell surface signaling occur at suture lines has not been previously examined the electrical changes of sodium transport occurring at a suture line in an animal model of large bowel cancer. Forty-eight female CF1 mice underwent colotomies with repair utilizing silk or chromic sutures. Twenty-four mice underwent sham operations to serve as controls. The mice were injected subcutaneously with the carcinogen DMH (1,2-dimethylhydrazine) 20 mg/kg or an identical volume of 0.9% saline for 6 weeks and were sacrificed 1 week after the last injection. The sites of the sutured colotomies or a piece of distal colon from the sham-operated mice were mounted in a modified Ussing chamber and the electrical properties and unidirectional sodium fluxes were measured. The potential difference (pd) across the distal colon was not significantly different in any suture group compared to that in sham-operated controls when treated with saline (pd sham, -2.3 +/- 0.2 mV (mean +/- SEM); silk, -1.7 +/- 0.3 mV, chromic, -1.9 +/- 0.3 mV, P greater than 0.05, unpaired Student t test). The potential difference was significantly lowered in both suture groups compared to sham operated animals after treatment with DMH (pd sham, -2.6 +/- 0.3 mV; silk, -1.5 +/- 0.2 mV, P less than 0.05; chromic, -1.6 +/- 0.4 mV, P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Colon/surgery , Colonic Neoplasms/surgery , Insect Proteins , Precancerous Conditions/surgery , Sodium/pharmacokinetics , 1,2-Dimethylhydrazine , Animals , Carcinogens , Catgut , Cell Membrane/drug effects , Cell Membrane/metabolism , Colon/drug effects , Colon/metabolism , Colonic Neoplasms/metabolism , Colonic Neoplasms/physiopathology , Dimethylhydrazines/adverse effects , Electric Conductivity , Female , Membrane Potentials/drug effects , Mice , Mice, Inbred Strains , Precancerous Conditions/metabolism , Precancerous Conditions/physiopathology , Proteins , Silk , Sutures
SELECTION OF CITATIONS
SEARCH DETAIL