Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters








Database
Language
Publication year range
1.
Rev Sci Instrum ; 95(6)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38829216

ABSTRACT

Non-destructive measurements of low-intensity charged particle beams are particularly challenging for beam diagnostics. At the Heavy Ion Accelerator Facility in Lanzhou (HIRFL), beams with weak currents below 1 µA are often provided for experiments. The detection of such low beam current is below the threshold of typical standard beam current transformers. Therefore, a low-intensity monitoring system is developed by using a sensitive capacitive pick-up (PU) and low-noise electronics. This device measures beam currents by digitally analyzing the amplitude of the PU signals using a homodyne detection scheme. During lab tests, the amplitude nonlinearity is <0.5% in the operational range of 1 nA-45 µA and the amplitude resolution is 0.94 nA. At present, four measurement systems for low beam currents are installed at HIRFL for the monitoring of standard operating conditions with low beam currents below 1 µA. After an absolute calibration with a Faraday cup, it can be used for accurate beam intensity measurement with a current resolution of about 1 nA.

2.
Rev Sci Instrum ; 93(6): 063301, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35778055

ABSTRACT

A new digital beam position and phase measurement (BPM) system was designed for the ion-Linac accelerator at the high intensity heavy ion accelerator facility. The fundamental and second harmonic signals are retrieved from the BPM electrodes to simultaneously calculate their respective beam positions and phases. All data acquisition and digital signal processing algorithm routines are performed in a field programmable gate array (FPGA). The position and phase information are obtained by using the in-phase and quadrature demodulation method. A practical and straightforward method is used to generate the second harmonic reference signal for processing the second harmonic beam signal. The reconfigurable filters are integrated into the FPGA to allow the measurement of short beam pulse length. The laboratory test results show that the achieved phase resolution is better than 0.2° and 0.03° when the input signal is -60 and -45 dBm, respectively. A position resolution better than 30 µm was achieved for an input power level of approximately -60 dBm, and it can reach 7 µm with the input power higher than -45 dBm. The entire execution time of the algorithm is accomplished within 3.4 µs, which provides a sufficient reaction time for the fast beam interlock signal to the machine protection system. The performance of this newly designed prototype BPM electronics was evaluated with the online proton beam.

3.
Rev Sci Instrum ; 93(4): 043306, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35489913

ABSTRACT

A diagonal-cut type beam position monitor (BPM) has been developed for the High Intensity Heavy-Ion Accelerator Facility (HIAF) project at the Institute of Modern Physics. Compared with other types of BPMs, the diagonal-cut type BPM has almost perfect position linearity, i.e., no non-linear correction required, which is advantageous for beams that are transversally large and have a complex charge distribution. The key parameters for the diagonal-cut type BPM have been simulated and optimized in detail and systematically herein. It was found that the crosstalk is improved by ∼10 dB at 160 MHz by insertion of a separate ring between two horizontal or vertical electrodes of the BPM made of stainless steel with vacuum as a dielectric. Furthermore, the longitudinal and transverse numerical simulation to evaluate the beam impedance on the diagonal-cut type BPM has been performed. The results for the crosstalk, position sensitivity, and electrode capacitance to ground obtained from simulations and laboratory measurements agree well. The vacuum of the BPM prototype after baking out at 250 °C for 72 h is better than 1.0 × 10-11 mbar. The simulated and on-line measured BPM output signal magnitude results are consistent with each other. This diagonal-cut type BPM structure will be considered for application to the HIAF project as a priority.

SELECTION OF CITATIONS
SEARCH DETAIL