Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Article in English | MEDLINE | ID: mdl-38797372

ABSTRACT

BACKGROUND AND OBJECTIVE: Sound localization plays a crucial role in our daily lives, enabling us to recognize voices, respond to alarming situations, avoid dangers, and navigate towards specific signals. However, this ability is compromised in patients with Single-Sided Deafness (SSD) and Asymmetric Hearing Loss (AHL), negatively impacting their daily functioning. The main objective of the study was to quantify the degree of sound source localization in patients with single-sided deafness or asymmetric hearing loss using a Cochlear Implant (CI) and to compare between the two subgroups. MATERIALS AND METHODS: This was a prospective, longitudinal, observational, single-center study involving adult patients diagnosed with profound unilateral or asymmetric sensorineural hearing loss who underwent cochlear implantation. Sound localization was assessed in a chamber equipped with seven speakers evenly distributed from -90º to 90º. Stimuli were presented at 1000 Hz and intensities of 65 dB, 70 dB, and 75 dB. Each stimulus was presented only once per speaker, totaling 21 presentations. The number of correct responses at different intensities was recorded, and angular error in degrees was calculated to determine the mean angular distance between the patient-indicated speaker and the speaker presenting the stimulus. Both assessments were conducted preoperatively without a cochlear implant and two years post-implantation. RESULTS: The total sample comprised 20 patients, with 9 assigned to the SSD group and 11 to the AHL group. The Preoperative Pure Tone Average (PTA) in free field was 31.7 dB in the SSD group and 41.8 dB in the AHL group. There was a statistically significant improvement in sound localization ability and angular error with the use of the cochlear implant at all intensities in both SSD and AHL subgroups. CONCLUSIONS: Cochlear implantation in patients with SSD and AHL enhances sound localization, reducing mean angular error and increasing the number of correct sound localization responses.

2.
Article in English | MEDLINE | ID: mdl-38224870

ABSTRACT

INTRODUCTION: The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. METHODS: Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. RESULTS: 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7±14.6 years. "Stability" was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43kΩ. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. CONCLUSIONS: Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.


Subject(s)
Cochlear Implantation , Cochlear Implants , Male , Adult , Humans , Female , Middle Aged , Aged , Electric Impedance , Retrospective Studies , Auditory Threshold
4.
Otol Neurotol ; 42(7): e905-e910, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33710155

ABSTRACT

OBJECTIVE: Evaluation of a new active osseointegrated bone-conduction hearing implant in moderate to severe mixed-hearing loss. STUDY DESIGN: Prospective observational study of a series of cases. SETTING: Tertial referral center. PATIENTS: Twenty patients with moderate mixed-hearing loss were evaluated (10 Cochlear Osia group and 10 Baha 5 Power Connect -control group). INTERVENTION: Rehabilitative. MAIN OUTCOME MEASURES: Hearing performance in quiet and in noise and quality-of-life were evaluated. RESULTS: Improvements in audibility, speech-understanding, speech-recognition, and quality-of-sound in noise and quiet were found for the Osia System compared with preoperative unaided hearing and performance was similar to that obtained with Baha 5 Power Connect. CONCLUSIONS: The new active transcutaneous bone conduction system provided a tonal improvement in free-field at middle and high frequencies. The performance in speech recognition in quiet and in noise was similar to control group outcomes.


Subject(s)
Bone-Anchored Prosthesis , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural , Hearing Loss , Speech Perception , Bone Conduction , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Humans , Prospective Studies , Treatment Outcome
5.
Article in English, Spanish | MEDLINE | ID: mdl-30573155

ABSTRACT

Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. The results in the APHAB and GBI questionnaires showed a reduction in the perception of the problem and an improvement in quality of life respectively. The results presented reflect the possibility of treatment of mixed hearing loss with the Ponto™ SuperPower device.


Subject(s)
Bone Conduction , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural/therapy , Osseointegration , Prostheses and Implants , Auditory Threshold , Equipment Design , Female , Humans , Male , Middle Aged , Patient Satisfaction , Prospective Studies , Quality of Life , Signal-To-Noise Ratio , Surveys and Questionnaires , Treatment Outcome
6.
Laryngoscope ; 128(7): 1720-1726, 2018 07.
Article in English | MEDLINE | ID: mdl-29152745

ABSTRACT

OBJECTIVE/HYPOTHESIS: To investigate outcomes including efficacy, quality of life, and levels of inflammatory markers of a mandibular advancement device (MAD) for moderate-to-severe obstructive sleep apnea (OSA). STUDY DESIGN: Case-control study. METHODS: Patients with apnea-hypopnea index (AHI) ≥ 15/hr who only accepted MAD therapy (study group) or who refused any treatment (control group) were recruited. At baseline and at 6 months, polysomnography, Epworth Sleepiness Scale (ESS), Functional Outcomes of Sleep Questionnaire (FOSQ), C-reactive protein (CRP), interleukin 1ß, interleukin 6, and tumor necrosis factor α (TNF-α) were assessed in both groups. RESULTS: At baseline, the study group (n = 30) showed a higher percentage of rapid eye movement sleep and higher CRP levels (P < .05) than the control group (n = 10). At 6 months, the MAD significantly improved AHI and lowest oxygen saturation (P < .01), non-rapid eye movement (N)1 and N3 sleep stages (P < .05), ESS score (P < .05), FOSQ total score (P < .01), interleukin 1ß (P < .05), and TNF-α (P < .01) compared with the untreated group. In the overall, moderate, and severe OSA groups, 63.3%, 75%, and 50%, respectively, achieved at least good response. CONCLUSIONS: Use of a MAD significantly improved polysomnographic parameters, quality of life, and some inflammatory markers (CRP, IL-ß, and TNF-α) in a significant proportion of patients with moderate OSA and in some patients with severe OSA. Hence, a MAD may be a viable alternative therapy in patients with moderate-to-severe OSA who refuse continuous positive airway pressure. LEVEL OF EVIDENCE: 3b. Laryngoscope, 128:1720-1726, 2018.


Subject(s)
Cytokines/blood , Orthodontic Appliances , Quality of Life , Sleep Apnea, Obstructive/therapy , Adult , Biomarkers/blood , C-Reactive Protein/analysis , Female , Humans , Male , Middle Aged , Polysomnography , Severity of Illness Index , Sleep Apnea, Obstructive/blood , Sleep Apnea, Obstructive/physiopathology , Sleepiness
8.
Article in English, Spanish | MEDLINE | ID: mdl-28117046

ABSTRACT

We included 9 patients implanted with Baha® Attract. All our patients were evaluated by free field tonal audiometry, free field verbal audiometry and free field verbal audiometry with background noise, all the tests were performed with and without the device. To evaluate the subjective component of the implantation, we used the Glasgow Benefit Inventory (GBI) and Abbreviated Profile of Hearing Aid Benefit (APHAB). The auditive assessment with the device showed average auditive thresholds of 35.8dB with improvements of 25.8dB over the previous situation. Speech reception thresholds were 37dB with Baha® Attract, showing improvements of 23dB. Maximum discrimination thresholds showed an average gain of 60dB with the device. Baha® Attract achieves auditive improvements in patients for whom it is correctly indicated, with a consequent positive subjective evaluation. This study shows the attenuation effect in transcutaneous transmission, that prevents the device achieving greater improvements.


Subject(s)
Audiometry , Cochlear Implants , Audiometry, Pure-Tone , Audiometry, Speech , Bone Conduction , Equipment Design , Humans , Osseointegration , Patient Satisfaction , Quality of Life , Signal-To-Noise Ratio , Surveys and Questionnaires , Treatment Outcome
9.
Acta Otorrinolaringol Esp ; 68(2): 98-105, 2017.
Article in English, Spanish | MEDLINE | ID: mdl-27542994

ABSTRACT

INTRODUCTION: Hiccup crises are generally benign and self-limiting, but longer episodes affect quality of life and must be treated. There are recognisable causes that otorhinolaryngologists must know and be aware for diagnosis and therapeutic alternatives. The main expression is a spasmodic glottic noise with characteristic neck alterations. PATIENTS AND METHODS: This was a retrospective study from 1979 with patients suffering persistent or recurrent hiccups. Chronobiology, comorbidity, findings from explorations, therapies and outcomes were noted. Thirty-seven patients were studied (mean age, 45.5±13.5 years; 30 males), with persistent hiccups in 23 (62%). RESULTS: A potential associated aetiology was observed in 24 cases (65%): oesophageal disorders -mainly gastroesophageal reflux- were detected in 14 cases and concomitant oncological disease was found in 8. Only 3 cases were admitted for surgery due to these findings. Therapeutic strategies with metoclopramide were used in 18 subjects, chlorpromazine in 17 and baclofen in 13, while carbamazepine or haloperidol were used in a minority. Phrenic nerve stimulation was employed in 6 patients. Hiccups disappeared in 32 cases. Out of 22 cases for which follow-up was possible, the hiccups recurred in 5 subjects (the subjects requiring new therapies) and 11 patients died. CONCLUSIONS: Chronic hiccup represents a multidisciplinary challenge that includes potential head and neck affection, a diagnostic schedule for ruling out causes, frequent base oesophageal alterations and high incidence of malignant neoplasm. Prokinetic and neuroleptic agents with antidopaminergic and anticholinergic effects are the pillars of its treatment.


Subject(s)
Hiccup , Otolaryngology , Adult , Aged , Chlorpromazine/therapeutic use , Chronic Disease , Combined Modality Therapy , Disease Management , Electric Stimulation Therapy , Esophageal Diseases/complications , Female , Gastroesophageal Reflux/complications , Hiccup/diagnosis , Hiccup/epidemiology , Hiccup/etiology , Hiccup/therapy , Humans , Male , Metoclopramide/therapeutic use , Middle Aged , Neoplasms/complications , Neoplasms/therapy , Otolaryngology/methods , Phrenic Nerve , Recurrence , Retrospective Studies , Young Adult
11.
Acta Otorrinolaringol Esp ; 67(3): 156-61, 2016.
Article in English, Spanish | MEDLINE | ID: mdl-26611424

ABSTRACT

INTRODUCTION AND OBJECTIVES: The caloric test is the gold standard for the loss of vestibular function diagnosis. The Video Head Impulse Test (vHIT) assesses the same reflex by using a video- assisted examination of the impulsive maneuver. We intend to compare the variation of results of the vHIT and the caloric test in patients with vestibular neuritis with respect to their initial condition at two different moments of their evolution and to check the level of correlation between them and with that of the DHI test METHODS: We explored 20 patients with neuritis by using both vHIT and the caloric test on the same day. We assessed the correlation between these two tests and with the DHI test for each patient at two different moments of their evolution. RESULTS: We calculated gain asymmetry and compared it with the canal paresis, but we found neither a linear correlation between them, nor a correlation between the DHI test or improvement of these two other tests. We conclude that the covert saccades maintain a similar speed whilst present in the VHIT, but the overts diminish their speed over time. CONCLUSIONS: The VHIT and the caloric test show different responses of the vestibulo-ocular reflex, because they stimulate different frequencies of this reflex. No correlation was found between the VHIT, the caloric test and the DHI test. The tests appear to complement one another.


Subject(s)
Caloric Tests , Head Impulse Test , Reflex, Vestibulo-Ocular , Vestibular Neuronitis/diagnosis , Adolescent , Adult , Aged , Female , Follow-Up Studies , Head Impulse Test/methods , Humans , Male , Middle Aged , Prospective Studies , Reflex, Abnormal , Regression Analysis , Saccades/physiology , Vestibular Neuronitis/physiopathology , Video Recording , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL