Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
J Clin Monit Comput ; 34(2): 197-205, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31981067

ABSTRACT

This paper reviews 28 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2018 and 2019, within the field of respiration. Papers were published covering endotracheal tube cuff pressure monitoring, ventilation and respiratory rate monitoring, lung mechanics monitoring, gas exchange monitoring, CO2 monitoring, lung imaging, and technologies and strategies for ventilation management.


Subject(s)
Respiration , Biomechanical Phenomena , Carbon Dioxide/metabolism , Electric Impedance , Humans , Intubation, Intratracheal , Lung/diagnostic imaging , Lung/physiology , Monitoring, Physiologic , Pressure , Pulmonary Gas Exchange , Pulmonary Ventilation , Respiration, Artificial , Respiratory Rate , Tomography
2.
J Clin Monit Comput ; 32(2): 197-205, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29480384

ABSTRACT

This paper reviews 32 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2016, within the field of respiration. Papers were published covering airway management, ventilation and respiratory rate monitoring, lung mechanics and gas exchange monitoring, in vitro monitoring of lung mechanics, CO2 monitoring, and respiratory and metabolic monitoring techniques.


Subject(s)
Monitoring, Physiologic/methods , Periodicals as Topic , Respiration , Respiratory Rate , Animals , Capnography , Carbon Dioxide/chemistry , Clinical Trials as Topic , Electric Impedance , Humans , Lung/physiology , Monitoring, Physiologic/instrumentation , Oximetry , Pulmonary Gas Exchange , Respiration, Artificial , Signal Processing, Computer-Assisted
3.
J Clin Monit Comput ; 31(2): 247-252, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28255799

ABSTRACT

This paper reviews 16 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2016, within the field of respiration. Papers were published covering peri- and post-operative monitoring of respiratory rate, perioperative monitoring of CO2, modeling of oxygen gas exchange, and techniques for respiratory monitoring.


Subject(s)
Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Oximetry/methods , Respiration , Respiratory Rate , Algorithms , Animals , Capnography , Carbon Dioxide , Electric Impedance , Electrocardiography , Humans , Postoperative Period , Pulmonary Gas Exchange , Respiration, Artificial
4.
J Clin Monit Comput ; 31(4): 773-781, 2017 Aug.
Article in English | MEDLINE | ID: mdl-27344663

ABSTRACT

Incomplete expiration of tidal volume can lead to dynamic hyperinflation and auto-PEEP. Methods are available for assessing these, but are not appropriate for patients with respiratory muscle activity, as occurs in pressure support. Information may exist in expiratory flow and carbon dioxide measurements, which, when taken together, may help characterize dynamic hyperinflation. This paper postulates such patterns and investigates whether these can be seen systematically in data. Two variables are proposed summarizing the number of incomplete expirations quantified as a lack of return to zero flow in expiration (IncExp), and the end tidal CO2 variability (varETCO2), over 20 breaths. Using these variables, three patterns of ventilation are postulated: (a) few incomplete expirations (IncExp < 2) and small varETCO2; (b) a variable number of incomplete expirations (2 ≤ IncExp ≤ 18) and large varETCO2; and (c) a large number of incomplete expirations (IncExp > 18) and small varETCO2. IncExp and varETCO2 were calculated from data describing respiratory flow and CO2 signals in 11 patients mechanically ventilated at 5 levels of pressure support. Data analysis showed that the three patterns presented systematically in the data, with periods of IncExp < 2 or IncExp > 18 having significantly lower variability in end-tidal CO2 than periods with 2 ≤ IncExp ≤ 18 (p < 0.05). It was also shown that sudden change in IncExp from either IncExp < 2 or IncExp > 18 to 2 ≤ IncExp ≤ 18 results in significant, rapid, change in the variability of end-tidal CO2 p < 0.05. This study illustrates that systematic patterns of expiratory flow and end-tidal CO2 are present in patients in supported mechanical ventilation, and that changes between these patterns can be identified. Further studies are required to see if these patterns characterize dynamic hyperinflation. If so, then their combination may provide a useful addition to understanding the patient at the bedside.


Subject(s)
Capnography/methods , Carbon Dioxide/analysis , Exhalation , Respiration, Artificial , Respiration , Capnography/instrumentation , Humans , Lung/physiology , Positive-Pressure Respiration , Positive-Pressure Respiration, Intrinsic , Reproducibility of Results , Tidal Volume , Time Factors
5.
Am J Transplant ; 17(3): 782-790, 2017 03.
Article in English | MEDLINE | ID: mdl-27992110

ABSTRACT

Organ shortage is the major limitation to kidney transplantation in the developed world. Conversely, millions of patients in the developing world with end-stage renal disease die because they cannot afford renal replacement therapy-even when willing living kidney donors exist. This juxtaposition between countries with funds but no available kidneys and those with available kidneys but no funds prompts us to propose an exchange program using each nation's unique assets. Our proposal leverages the cost savings achieved through earlier transplantation over dialysis to fund the cost of kidney exchange between developed-world patient-donor pairs with immunological barriers and developing-world patient-donor pairs with financial barriers. By making developed-world health care available to impoverished patients in the developing world, we replace unethical transplant tourism with global kidney exchange-a modality equally benefitting rich and poor. We report the 1-year experience of an initial Filipino pair, whose recipient was transplanted in the United states with an American donor's kidney at no cost to him. The Filipino donor donated to an American in the United States through a kidney exchange chain. Follow-up care and medications in the Philippines were supported by funds from the United States. We show that the logistical obstacles in this approach, although considerable, are surmountable.


Subject(s)
Cost-Benefit Analysis , Directed Tissue Donation , Health Care Costs/legislation & jurisprudence , Kidney Failure, Chronic/economics , Kidney Transplantation/economics , Living Donors/supply & distribution , Tissue and Organ Procurement/economics , Developing Countries , Glomerular Filtration Rate , Graft Survival , Health Resources , Health Services Accessibility , Humans , Kidney Failure, Chronic/surgery , Kidney Function Tests , Kidney Transplantation/legislation & jurisprudence , Kidney Transplantation/methods , Philippines , Policy Making , Prognosis , Risk Factors , Tissue and Organ Procurement/methods , United States
6.
Br J Anaesth ; 116(6): 855-61, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27199317

ABSTRACT

BACKGROUND: General anaesthesia decreases pulmonary compliance and increases pulmonary shunt due to the development of atelectasis. The presence of capnoperitoneum during laparoscopic surgery may further decrease functional residual capacity, promoting an increased amount of atelectasis compared with laparotomy. The aim of this study was to evaluate the effects of different levels of positive end-expiratory pressure (PEEP) in both types of surgery and to investigate whether higher levels of PEEP should be used during laparoscopic surgery. METHODS: This prospective observational study included 52 patients undergoing either laparotomy or laparoscopic surgery. Three levels of PEEP were applied in random order: (1) zero (ZEEP), (2) 5 cmH2O and (3) 10 cmH2O. Pulmonary shunt and ventilation/perfusion mismatch were assessed by the automatic lung parameter estimator system. RESULTS: Pulmonary shunt was similar in both groups. However, in laparotomy, a PEEP of 5 cmH2O significantly decreased shunt when compared with ZEEP (12 vs 6%; P=0.001), with additional PEEP having no further effect. In laparoscopic surgery, a significant reduction in shunt (13 vs 6%; P=0.001) was obtained only at a PEEP of 10 cmH2O. Although laparoscopic surgery was associated with a lower pulmonary compliance, increasing levels of PEEP were able to ameliorate it in both groups. CONCLUSION: Both surgeries have similar negative effects on pulmonary shunt, while the presence of capnoperitoneum reduced only the pulmonary compliance. It appears that a more aggressive PEEP level is required to reduce shunt and to maximize compliance in case of laparoscopic surgery.


Subject(s)
Abdomen/surgery , Lung Compliance , Positive-Pressure Respiration/adverse effects , Aged , Anesthesia, General , Female , Humans , Intraoperative Complications/prevention & control , Laparoscopy/methods , Laparoscopy/standards , Laparotomy , Male , Middle Aged , Prospective Studies , Pulmonary Atelectasis/prevention & control , Respiration, Artificial
7.
J Clin Monit Comput ; 30(1): 7-12, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26719297

ABSTRACT

This paper reviews 17 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2015, within the field of respiration. Papers were published covering monitoring and training of breathing, monitoring of gas exchange, hypoxemia and acid-base, and CO2 monitoring.


Subject(s)
Lung Diseases/diagnosis , Periodicals as Topic/trends , Polysomnography/trends , Respiration Disorders/diagnosis , Respiratory Function Tests/trends , Humans , Lung Diseases/prevention & control , Polysomnography/instrumentation , Polysomnography/methods , Respiration Disorders/prevention & control , Respiratory Function Tests/instrumentation , Respiratory Function Tests/methods
8.
J Crit Care ; 30(5): 1008-15, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26067844

ABSTRACT

PURPOSE: This article evaluates how mathematical models of gas exchange, blood acid-base status, chemical respiratory drive, and muscle function can describe the respiratory response of spontaneously breathing patients to different levels of pressure support. METHODS: The models were evaluated with data from 12 patients ventilated in pressure support ventilation. Models were tuned with clinical data (arterial blood gas measurement, ventilation, and respiratory gas fractions of O2 and CO2) to describe each patient at the clinical level of pressure support. Patients were ventilated up to 5 different pressure support levels, for 15 minutes at each level to achieve steady-state conditions. Model-simulated values of respiratory frequency (fR), arterial pH (pHa), and end-tidal CO2 (FeCO2) were compared to measured values at each pressure support level. RESULTS: Model simulations compared well to measured data with Bland-Altman bias and limits of agreement of fR of 0.7 ± 2.2 per minute, pHa of -0.0007 ± 0.019, and FeCO2 of -0.001 ± 0.003. CONCLUSION: The models describe patients' fR, pHa, and FeCO2 response to changes in pressure support with low bias and narrow limits of agreement.


Subject(s)
Critical Illness/therapy , Respiration, Artificial , Respiratory Muscles/physiopathology , Aged , Blood Gas Analysis/methods , Humans , Middle Aged , Models, Theoretical , Positive-Pressure Respiration , Pulmonary Gas Exchange , Reproducibility of Results , Respiration , Respiratory Mechanics
9.
Am J Transplant ; 15(10): 2646-54, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26015291

ABSTRACT

Failure to convert computer-identified possible kidney paired donation (KPD) exchanges into transplants has prohibited KPD from reaching its full potential. This study analyzes the progress of exchanges in moving from "offers" to completed transplants. Offers were divided into individual segments called 1-way transplants in order to calculate success rates. From 2007 to 2014, the Alliance for Paired Donation performed 243 transplants, 31 in collaboration with other KPD registries and 194 independently. Sixty-one of 194 independent transplants (31.4%) occurred via cycles, while the remaining 133 (68.6%) resulted from nonsimultaneous extended altruistic donor (NEAD) chains. Thirteen of 35 (37.1%) NEAD chains with at least three NEAD segments accounted for 68% of chain transplants (8.6 tx/chain). The "offer" and 1-way success rates were 21.9 and 15.5%, respectively. Three reasons for failure were found that could be prospectively prevented by changes in protocol or software: positive laboratory crossmatch (28%), transplant center declined donor (17%) and pair transplanted outside APD (14%). Performing a root cause analysis on failures in moving from offer to transplant has allowed the APD to improve protocols and software. These changes have improved the success rate and the number of transplants performed per year.


Subject(s)
Internet , Kidney Transplantation , Tissue and Organ Procurement/methods , Algorithms , Decision Support Techniques , Donor Selection/methods , Donor Selection/organization & administration , Donor Selection/trends , Humans , Living Donors , Models, Statistical , Tissue and Organ Procurement/organization & administration , Tissue and Organ Procurement/trends , United States
11.
Med Eng Phys ; 37(4): 341-9, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25686673

ABSTRACT

This paper presents a mathematical model-approach to describe and quantify patient-response to changes in ventilator support. The approach accounts for changes in metabolism (V̇O2, V̇CO2) and serial dead space (VD), and integrates six physiological models of: pulmonary gas-exchange; acid-base chemistry of blood, and cerebrospinal fluid; chemoreflex respiratory-drive; ventilation; and degree of patients' respiratory muscle-response. The approach was evaluated with data from 12 patients on volume support ventilation mode. The models were tuned to baseline measurements of respiratory gases, ventilation, arterial acid-base status, and metabolism. Clinical measurements and model simulated values were compared at five ventilator support levels. The models were shown to adequately describe data in all patients (χ(2), p > 0.2) accounting for changes in V̇CO2, VD and inadequate respiratory muscle-response. F-ratio tests showed that this approach provides a significantly better (p < 0.001) description of measured data than: (a) a similar model omitting the degree of respiratory muscle-response; and (b) a model of constant alveolar ventilation. The approach may help predict patients' response to changes in ventilator support at the bedside.


Subject(s)
Models, Cardiovascular , Outcome Assessment, Health Care/methods , Respiration, Artificial/methods , Aged , Aged, 80 and over , Carbon Dioxide/metabolism , Computer Simulation , Female , Humans , Male , Middle Aged , Movement/physiology , Pulmonary Gas Exchange/physiology , Respiratory Muscles/physiopathology
12.
Comput Methods Programs Biomed ; 104(2): 27-8, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22000708

Subject(s)
Models, Biological
14.
J Clin Monit Comput ; 25(1): 57-70, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20734118

ABSTRACT

OBJECTIVE: Debate still exists as to whether the Stewart (modern) or traditional model of acid-base chemistry is best in assessing the acid-base status of critically ill patients. Recent studies have compared various parameters from the modern and traditional approaches, assessing the clinical usefulness of parameters such as base excess, anion gap, corrected anion gap, strong ion difference and strong ion gap. To compare the clinical usefulness of these parameters, and hence the different approaches, requires a clear understanding of their meaning; a task only possible through understanding the mathematical basis of the approaches. The objective of this paper is to provide this understanding, limiting the mathematics to a necessary minimum. METHOD: The first part of this paper compares the mathematics of these approaches, with the second part illustrating the clinical usefulness of the approaches using a patient example. RESULTS: This analysis illustrates the almost interchangeable nature of the equations and that the same clinical conclusions can be drawn regardless of the approach adopted. CONCLUSIONS: Although different in their concepts, the traditional and modern approaches based on mathematical models can be seen as complementary giving, in principle, the same information about the acid-base status of plasma.


Subject(s)
Acid-Base Imbalance , Monitoring, Physiologic/methods , Monitoring, Physiologic/trends , Plasma/chemistry , Acid-Base Equilibrium , Algorithms , Bicarbonates/blood , Buffers , Humans , Ions , Models, Theoretical , Software
15.
Emerg Med J ; 26(4): 268-72, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19307387

ABSTRACT

OBJECTIVE: This paper evaluates a method in which arterial values of pH, carbon dioxide tension (Pco(2)) and oxygen tension (Po(2)) calculated from venous values and pulse oximetry are compared with simultaneously measured arterial values. METHODS: 103 adult patients from three departments (pulmonary medicine, thoracic intensive care and multidisciplinary intensive care) were studied. The patients belonged to three groups: (1) 31 haemodynamically stable patients with a diagnosis of chronic obstructive lung disease (COLD); (2) 49 haemodynamically stable patients without COLD; and (3) 23 haemodynamically unstable patients without COLD. Arterial and venous (peripheral and, where possible, central and mixed) blood samples were taken simultaneously and anaerobically. Peripheral arterial oxygen saturation was measured with a pulse oximeter. The principle of the method is to simulate the transport of venous blood back through the tissues using the respiratory quotient (adding oxygen and removing carbon dioxide) until simulated arterial oxygenation matches that measured by pulse oximetry. RESULTS: Calculated values of arterial pH and Pco(2) had very small bias and standard deviations regardless of the venous sampling site. In all cases these errors were within those considered acceptable for the performance of laboratory equipment, and well within the limits of error acceptable in clinical practice. In addition, the standard deviation (SD) of calculated values of pH and Pco(2) was similar to the variability between consecutive arterial samples. For peripheral oxygen saturation values < or =96%, the method can calculate Po(2) with an SD of 0.93, which may be useful in clinical practice. Calculations made from peripheral venous blood were significantly more accurate than those from central venous blood. CONCLUSION: Arterial pH and Pco(2) can be calculated precisely from peripheral venous blood in a broad patient population. The method has potential for use as a screening tool in emergency medical departments and in medical and surgical wards to assess a patient's acid-base and oxygenation status prior to sampling arterial blood or to help in the decision to refer the patient to the ICU. In departments where arterial blood gas values are used to monitor patients (eg, pulmonary medicine), the method might reduce the number of arterial samples taken by replacing them with peripheral venous blood samples, thus reducing the need for painful arterial punctures.


Subject(s)
Carbon Dioxide/blood , Oxygen/blood , Acid-Base Equilibrium , Adult , Aged , Aged, 80 and over , Blood Gas Analysis/methods , Blood Specimen Collection/methods , Female , Humans , Hydrogen-Ion Concentration , Male , Middle Aged , Oximetry/methods , Partial Pressure , Pulmonary Disease, Chronic Obstructive/blood , Reproducibility of Results
16.
Eur Respir J ; 33(5): 1141-7, 2009 May.
Article in English | MEDLINE | ID: mdl-19129271

ABSTRACT

The aim of the present study was to evaluate a method for calculating arterial values of pH, carbon dioxide tension (P(CO(2))) and oxygen tension (P(O(2))) from peripheral venous values. In total, 40 patients were studied. Arterial and peripheral venous blood were sampled at a department of respiratory diseases. Arterial values were calculated from venous, and measured and calculated values of arterial pH, P(CO(2)) and P(O(2)) were compared. Measured and calculated values of pH and P(CO(2)) correlated well, with the difference between them having a very small bias and standard deviation (pH -0.001+/-0.013, P(CO(2)) -0.09+/-0.28 kPa) within those considered acceptable for laboratory equipment and clinical practice. All but four patients had peripheral oxygen saturation (S(p,O(2)))

Subject(s)
Acid-Base Equilibrium , Blood Gas Analysis/methods , Carbon Dioxide/blood , Oxygen/blood , Adult , Aged , Aged, 80 and over , Blood Specimen Collection , Female , Humans , Hydrogen-Ion Concentration , Linear Models , Male , Middle Aged , Oximetry/methods , Respiratory Tract Diseases/blood , Sensitivity and Specificity
17.
Acta Anaesthesiol Scand ; 51(9): 1202-10, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17850560

ABSTRACT

BACKGROUND: In a previous study, we showed that oxygenation was impaired for up to 5 day after conventional coronary artery bypass grafting (CABG). As cardiopulmonary bypass (CPB) may have a detrimental effect on pulmonary function, we hypothesized that coronary revascularization grafting without the use of CPB (OPCAB) would affect post-operative oxygenation and release of inflammatory mediators less compared with CABG. METHODS: Low-risk patients scheduled for elective coronary revascularization were randomly assigned to one of two groups (CABG, n = 17 or OPCAB, n = 18). Two parameters of oxygenation, shunt (%) and ventilation-perfusions mismatch, described as DeltaPO(2) (kPa), were estimated for up to 5 days post-operatively. Systemic release of interleukin (IL)-6, -8 and -10, C-reactive protein (CRP) and neutrophils were measured in peripheral blood samples for up to 3 days post-operatively. The lungs participation in the cytokine response was evaluated from mixed venous blood samples taken within the first 16 h post-operatively. RESULTS: OPCAB was followed by a higher shunt (P = 0.047), with no difference (P = 0.47) in the deterioration of DeltaPO(2) between the groups. OPCAB was followed by an attenuated systemic release of IL-8 (P = 0.041) and IL-10 (P = 0.006), while the release of IL-6 (P = 0.94), CRP (P = 0.121) and neutrophils (P = 0.078) did not differ between the groups. Indications of an uptake of cytokines in the lungs were found after OPCAB. CONCLUSIONS: When comparing OPCAB with CABG, oxygenation was more affected and only part of the systemic inflammatory response was attenuated.


Subject(s)
Coronary Artery Bypass/adverse effects , Inflammation Mediators/blood , Oxygen/blood , Aged , Blood Gas Analysis , C-Reactive Protein/analysis , Coronary Artery Bypass, Off-Pump , Female , Humans , Interleukin-10/blood , Interleukin-6/blood , Interleukin-8/blood , Male , Middle Aged , Monitoring, Physiologic/methods , Risk Factors , Time Factors , Troponin T/blood , Ventilation-Perfusion Ratio
18.
Physiol Meas ; 28(3): 235-47, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17322589

ABSTRACT

Elastic pressure/volume (PV) curves of the respiratory system have attracted increasing interest, because they may be helpful to optimize ventilator settings in patients undergoing mechanical ventilation. Clinically applicable methods need to be fast, use routinely available equipment, draw the inspiratory and expiratory PV curve limbs, separate the resistive and viscoelastic properties of the respiratory system from the elastic properties, and provide reproducible measurements. This paper presents a computer-controlled method for rapid measurements of static PV curves using a long inflation-deflation with pauses, and its evaluation in six pigs before and after lung damage caused by oleic acid. The method is fast, i.e. 20.5 +/- 1.9 s (mean +/- SD) in healthy lungs and 17.7 +/- 4.1 s in diseased lungs, this including inspiratory and expiratory pauses of 1.1 s duration. In addition the only equipment used was a clinical ventilator and a PC. For healthy and damaged lungs expiratory PV curve limbs were very reproducible and were at higher volume than the inspiratory limbs, indicating hysteresis. For damaged lungs inspiratory PV limbs were reproducible. For healthy lungs the inspiratory limbs were reproducible but only after the first inflation-deflation. It is possible that during the first inflation alveoli are recruited which are not derecruited on deflation, shifting the inspiratory limb of the PV curve. The paused long inflation-deflation technique provides a quick, automated measurement of static PV curves on both inspiratory and expiratory limbs using routinely available equipment in the intensive care unit.


Subject(s)
Lung/physiology , Respiratory Function Tests , Respiratory Mechanics/physiology , Animals , Lung/physiopathology , Microcomputers , Oleic Acid , Respiration, Artificial , Swine
19.
J Clin Monit Comput ; 20(6): 421-9, 2006 Dec.
Article in English | MEDLINE | ID: mdl-16977430

ABSTRACT

OBJECTIVE: To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS: Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side-effects of mechanical ventilation in a decision theoretic approach. Penalties are quantified for risk of lung barotrauma, acidosis or alkalosis, oxygen toxicity or absorption atelectasis, and hypoxaemia. RESULTS: The system is presented with an example of its use in a post-surgical patient. The mathematical models describe the patient's data, and the system suggests an optimal ventilator strategy in line with clinical practice. CONCLUSIONS: The system illustrates how mathematical models combined with decision theory can aid in the difficult compromises necessary when deciding on ventilator settings.


Subject(s)
Models, Biological , Respiration, Artificial/methods , Respiratory Mechanics , Carbon Dioxide/physiology , Computer Systems , Decision Theory , Humans , Mathematics , Monitoring, Physiologic , Oxygen/physiology , Respiration, Artificial/statistics & numerical data
20.
J Appl Physiol (1985) ; 101(3): 826-32, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16763097

ABSTRACT

The multiple inert-gas elimination technique (MIGET) is a complex mathematical model and experimental technique for understanding pulmonary gas exchange. Simpler mathematical models have been proposed that have a limited view compared with MIGET but may be applicable for use in clinical practice. This study examined the use of a simple model of gas exchange to describe MIGET retention and excretion data in seven pigs before and following lung damage caused by oleic acid infusion and subsequently at different levels of positive end-expiratory pressure. The simple model was found to give, on average, a good description of MIGET data, as evaluated by a chi(2) test on the weighted residual sum of squares resulting from the model fit (P > 0.2). Values of the simple model's parameters (dead-space volume, shunt, and the fraction of alveolar ventilation going to compartment 2) compared well with the similar MIGET parameters (dead-space volume, shunt, log of the standard deviation of the perfusion, log of the standard deveation of the ventilation), giving values of bias and standard deviation on the differences between dead-space volume and shunt of 0.002 +/- 0.002 liter and 7.3 +/- 2.1% (% of shunt value), respectively. Values of the fraction of alveolar ventilation going to compartment 2 correlated well with log of the standard deviation of the perfusion (r(2) = 0.86) and log of the standard deviation of the ventilation (r(2) = 0.92). These results indicate that this simple model provides a good description of lung pathology following oleic acid infusion. It remains to be seen whether physiologically valid values of the simple model parameters can be obtained from clinical experiments varying inspired oxygen fraction. If so, this may indicate a role for simple models in the clinical interpretation of gas exchange.


Subject(s)
Lung Diseases/physiopathology , Lung/physiopathology , Models, Biological , Oxygen/metabolism , Pulmonary Gas Exchange , Animals , Computer Simulation , Infusions, Intravenous , Kinetics , Lung/drug effects , Lung Diseases/chemically induced , Metabolic Clearance Rate , Oleic Acid , Reproducibility of Results , Sensitivity and Specificity , Swine , Ventilation-Perfusion Ratio
SELECTION OF CITATIONS
SEARCH DETAIL