Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters








Database
Language
Publication year range
1.
Cont Lens Anterior Eye ; 47(3): 102133, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38467534

ABSTRACT

BACKGROUND: To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant. RESULTS: Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.


Subject(s)
Accommodation, Ocular , Corneal Wavefront Aberration , Orthokeratologic Procedures , Refraction, Ocular , Visual Acuity , Humans , Male , Female , Accommodation, Ocular/physiology , Prospective Studies , Refraction, Ocular/physiology , Visual Acuity/physiology , Young Adult , Corneal Wavefront Aberration/physiopathology , Corneal Topography , Adult , Myopia/therapy , Myopia/physiopathology , Follow-Up Studies , Adolescent , Contact Lenses
2.
Eye Contact Lens ; 50(4): 177-182, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38305377

ABSTRACT

PURPOSE: To evaluate a new in vitro technique for measuring soft contact lens wettability using a nonmodified commercial videokeratoscope, the Medmont E300. To this end, the capability of different artificial tears containing hyaluronic acid (HA) to improve soft contact lens wettability in vitro was investigated. METHODS: An experimental in vitro study was conducted to assess the wetting properties of three artificial tears containing different concentrations of HA (0.1%, 0.2%, and 0.3%) on soft contact lenses. A saline solution was used as the control. For each solution, 15 hydrogel (Ocufilcon D) contact lenses and 15 silicone-hydrogel (Somofilcon A) contact lenses were evaluated. The in vitro wettability of the lenses was measured using the Medmont E300 with a self-developed technique, which involved measuring the tear film surface quality (TFSQ) mean, TFSQ area, TFSQ central, and TFSQ inferior. RESULTS: Compared with the saline solution, all the concentration of HA (0.1%, 0.2%, and 0.3%) improved the in vitro wettability of both soft contact lenses by decreasing their TFSQ mean and TFSQ area ( P <0.05). Regression models revealed an exponential relationship between contact lens wettability and the concentration of HA for both soft contact lenses ( R >0.5, P <0.05). Furthermore, the hydrogel contact lens presented a wetter surface than the silicone-hydrogel contact lens ( P <0.05). CONCLUSIONS: The measurement of in vitro wettability of soft contact lenses with a nonmodified Medmont E300 seems to be a useful technique to evaluate the wetting properties of contact lens products.


Subject(s)
Contact Lenses, Hydrophilic , Lubricant Eye Drops , Humans , Wettability , Saline Solution , Hydrogels , Silicones
3.
Cont Lens Anterior Eye ; 47(1): 102098, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38040556

ABSTRACT

PURPOSE: To analyze the visual quality of a new multifocal scleral lens with a customized decentred optic zone compared to a conventional design by measuring visual acuity, contrast sensitivity function, stereopsis, subjective vision and comfort after one month of wear. METHODS: Nineteen presbyopic subjects were fitted with two multifocal scleral lens designs: a conventional multifocal and a customized decentred optical zone design. All subjects wore both scleral lens designs for one month with a two-week washout period. The main variables evaluated included high and low-contrast visual acuity under photopic and mesopic light conditions, binocular defocus curves, contrast sensitivity function and a visual analogue scale (VAS) for subjective vision and comfort. RESULTS: Comparing the two scleral lens designs, statistically significant differences in visual acuity were found, highlighting the improvement in more than one chart line (6 letters) for low contrast near tests under photopic light conditions with the decentred optics lens design. VAS questionnaire scores also showed a significant improvement in distance and overall subjective vision with the decentred optics lenses. Contrast sensitivity function showed an improvement with decentred multifocal lenses at all spatial frequencies measured, being statistically significant for 12 cycles per degree. No differences in stereoacuity were found. CONCLUSION: Multifocal scleral lenses with a customized decentred optical zone proved to be a promising refractive correction in presbyopic subjects after one month of wear, offering good comfort and visual quality under photopic and mesopic light conditions.


Subject(s)
Lenses, Intraocular , Presbyopia , Humans , Presbyopia/therapy , Visual Acuity , Contrast Sensitivity , Refraction, Ocular , Vision Tests
4.
Eye Contact Lens ; 50(1): 35-40, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38124285

ABSTRACT

PURPOSE: To compare visual quality, contrast sensitivity, stereopsis, subjective vision, and comfort between monofocal and multifocal scleral lens (SL) designs. METHODS: An experimental, cross over and short-term pilot study has been performed. Nineteen presbyopic patients (51.9±3.8 years) with regular corneas participated voluntarily in the study and Onefit MED monofocal and multifocal SL designs were fitted bilaterally. Subjective vision and comfort, contrast sensitivity function, stereopsis, high- and low-contrast visual acuity (VA) at 4 m and 40 cm under photopic and mesopic conditions, and defocus curves were measured. Data analysis was performed with nonparametric tests. P<0.05 was considered as statistically significant. RESULTS: Mean addition power of the prescribed lenses was 1.72±0.38 diopters. Multifocal design showed a statistically significant improvement for intermediate and near vision in the defocus curve under photopic and mesopic conditions (P<0.05), however, worsening in stereopsis (P<0.05) and contrast sensitivity for high spatial frequencies (P<0.05). Distance visual acuity (VA) showed significantly lower values under mesopic conditions for high- and low-contrast tests (P<0.05), and on low-contrast test under photopic conditions (P<0.001) with the multifocal design. CONCLUSION: Multifocal SLs showed better visual performance at intermediate and near distances without compromising distance vision under photopic conditions for a high-contrast test when compared with monofocal design.


Subject(s)
Contrast Sensitivity , Lenses, Intraocular , Humans , Cornea , Depth Perception , Pilot Projects , Visual Acuity
5.
Cont Lens Anterior Eye ; 45(4): 101540, 2022 08.
Article in English | MEDLINE | ID: mdl-34799247

ABSTRACT

Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essential on SL fitting. For orthokeratology lenses central epithelial thinning and peripheral thickening and their regression could be quantified with OCT after Ortho-K lens wear. Blood vessel compression on the landing zone as well as vault thickness and fluid reservoir (FR) turbidity could be imaged with OCT. Tear film evaluation on contact lens wearers is essential because its use could lead to variations on the biochemical components in tears. Changes in tear meniscus dynamics and several parameters such as volume (TMV), tear meniscus height (HMT) and turbidity could be determined with OCT and positively correlated with the instillation of different ophthalmic solutions with Non-Invasive Break Up Time (NIBUT) and Schirmer test values. This manuscript shows the increasing applicability of OCT technology for the in vivo characterization of contact lens fitting and interaction with the ocular surface in a faster, safer and non-invasive way. Future research will still allow exploring OCT imaging to its full potential in contact lens practice, as there is still a significant amount of information contained in the images that are not yet easy to extract, analyze and give clinical value.


Subject(s)
Contact Lenses, Hydrophilic , Tomography, Optical Coherence , Conjunctiva , Cornea/diagnostic imaging , Humans , Tears/chemistry , Tomography, Optical Coherence/methods
SELECTION OF CITATIONS
SEARCH DETAIL