1.
Clin J Sport Med ; 2024 May 29.
Article in English | MEDLINE | ID: mdl-38810121

ABSTRACT

OBJECTIVE: To compare clinical outcomes following steroid injections using the anterior and posterior approaches. DESIGN: Systematic review with meta-analysis. SETTING: Embase, Web of Science, and Cochrane Center Register of Controlled Trials were searched for randomized control trials (RCTs) and prospective comparative studies. PATIENTS: Patients with adhesive capsulitis. INTERVENTIONS: Glenohumeral steroid injections using either anterior or posterior approach. MAIN OUTCOME MEASURES: Pain visual analog scale (VAS) and shoulder range of motion (ROM) at 12 weeks, accuracy, and adverse events. Standardized mean difference (SMD) for VAS and weighted mean difference (WMD) for ROMs. RESULTS: We identified 6 RCTs and one prospective comparative study with a total of 468 patients. While there was no difference in pain VAS at 12 weeks between the 2 approaches (SMD, -0.86; 95% CI, -1.76 to 0.04), the anterior approach resulted in greater improvements in external rotation (WMD, 8.08; 95% CI, 0.79-15.38) and abduction (WMD, 6.76; 95% CI, 3.05-10.48) compared with the posterior approach. Subgroup analysis with RCTs that utilized steroid injection with hydrodilatation for both approaches demonstrated greater reduction in pain VAS at 12 weeks with the anterior approach (SMD, -0.52; 95% CI, -0.98 to -0.07). Overall, procedures were well tolerated without major complications. CONCLUSIONS: While pain reduction is similar, the anterior approach may be more beneficial in restoring shoulder external rotation and abduction compared with the posterior approach at 12 weeks. Steroid injection combined with hydrodilatation may further improve pain control when performed with the anterior approach at 12 weeks.

3.
J Clin Med ; 13(4)2024 Feb 17.
Article in English | MEDLINE | ID: mdl-38398445

ABSTRACT

BACKGROUND: Although corticosteroid injections are an effective treatment for musculoskeletal pathologies, they may not be suitable for all patients. The purpose of this systematic review was to compare clinical outcomes between patients who received NSAID and corticosteroid injections for various orthopedic conditions. METHODS: Medline, Embase, Web of Science, and Cochrane Central Register of Controlled Trials were searched, and meta-analyses were performed using a random-effects model for outcomes presented in three or more studies. Other studies were qualitatively analyzed. RESULTS: A total of 28 articles with 2113 patients were included. A meta-analysis of five studies in patients with shoulder impingement syndrome demonstrated that there was no significant difference in the pain visual analogue scale (VAS) between subacromial NSAID injections and corticosteroid injections at 1 month [weighted mean difference (WMD) -0.244; 95% CI, -1.232 to 0.745; I2, 94.5%]. For patients with knee osteoarthritis, a meta-analysis of three studies demonstrated that there was no significant difference between intraarticular NSAID injections and corticosteroid injections in pain VAS at 1 month (WMD 0.754; 95% CI, -0.413 to 1.921; I2, 90.2%) and 3 months (WMD-0.089; 95% CI, -0.345 to 0.166; I2, 0%). A review of the studies assessing pain outcomes for hip osteoarthritis, adhesive capsulitis, and plantar fasciitis showed no significant differences between the NSAID and corticosteroid groups. CONCLUSION: NSAID injections may be safe and effective alternatives to steroid injections, especially in shoulder impingement syndrome and knee osteoarthritis.

4.
Foot Ankle Orthop ; 6(3): 24730114211019371, 2021 Jul.
Article in English | MEDLINE | ID: mdl-35097456

ABSTRACT

Level V, clinical tips.

5.
Bone Joint Res ; 9(4): 173-181, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32431808

ABSTRACT

AIMS: Femoroacetabular impingement (FAI) is a potential cause of hip osteoarthritis (OA). The purpose of this study was to investigate the expression profile of matrix metalloproteinases (MMPs) in the labral tissue with FAI pathology. METHODS: In this study, labral tissues were collected from four FAI patients arthroscopically and from three normal hips of deceased donors. Proteins extracted from the FAI and normal labrums were separately applied for MMP array to screen the expression of seven MMPs and three tissue inhibitors of metalloproteinases (TIMPs). The expression of individual MMPs and TIMPs was quantified by densitometry and compared between the FAI and normal labral groups. The expression of selected MMPs and TIMPs was validated and localized in the labrum with immunohistochemistry. RESULTS: On MMP arrays, most of the targeted MMPs and TIMPs were detected in the FAI and normal labral proteins. After data normalization, in comparison with the normal labral proteins, expression of MMP-1 and MMP-2 in the FAI group was increased and expression of TIMP-1 reduced. The histology of the FAI labrum showed disorderly cell distribution and altered composition of thick and thin collagen fibres. The labral cells expressing MMP-1 and MMP-2 were localized and their percentages were increased in the FAI labrum. Immunohistochemistry confirmed that the percentage of TIMP-1 positive cells was reduced in the FAI labrum. CONCLUSION: This study established an expression profile of MMPs and TIMPs in the FAI labrum. The increased expression of MMP-1 and MMP-2 and reduced expression of TIMP-1 in the FAI labrum are indicative of a pathogenic role of FAI in hip OA development.Cite this article: Bone Joint Res. 2020;9(4):173-181.

6.
Knee Surg Sports Traumatol Arthrosc ; 27(9): 2863-2876, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31020353

ABSTRACT

PURPOSE: The purpose of this study was to compare the reliability and accuracy of existing computed tomography (CT) methods for measuring the distal tibiofibular syndesmosis in uninjured, paired cadaveric specimens and in simulated malreduction models. It was hypothesized that a repeatable set of measurements exists to accurately and quantitatively describe the typical forms of syndesmotic malreduction using contralateral ankle comparison. METHODS: Twelve cadaveric lower-leg specimen pairs were imaged with CT to generate models for this study. Thirty-five measurements were performed on each native model. Next, four distinct fibular malreductions were produced via digital simulation and all measurements were repeated for each state: (1) 2-mm lateral translation; (2) 2-mm posterior translation; (3) 7-degree external rotation; (4) the previous three states combined. The modified standardized response mean (mSRM) was calculated for each measurement. To assess rater reliability and side-to-side agreements of the native state measurements, intraclass correlation coefficients (ICC) and Pearson correlation coefficients (PCC) were calculated, respectively. RESULTS: The most responsive measurements for detecting isolated malreduction were the Leporjärvi clear space for lateral translation, the Nault anterior tibiofibular distance for posterior translation, and the Nault talar dome angle for external rotation of the fibula. These measurements demonstrated fair to excellent inter-rater ICCs (0.64-0.76) and variable side-to-side PCCs (0.14-0.47). CONCLUSIONS: The most reliable method to assess the syndesmosis on CT was to compare side-to-side differences using three distinct measurements, one for each type of fibular malreduction, allowing assessment of the magnitude and directionality of syndesmosis malreduction. Reliable evaluation is essential for assessing subtle syndesmosis injuries, malreduction and surgical planning.


Subject(s)
Ankle Fractures/diagnostic imaging , Ankle Injuries/diagnostic imaging , Ankle Joint/diagnostic imaging , Ankle/diagnostic imaging , Adult , Aged , Ankle Fractures/surgery , Ankle Injuries/surgery , Ankle Joint/surgery , Cadaver , Fibula/diagnostic imaging , Fibula/surgery , Humans , Middle Aged , Reproducibility of Results , Rotation , Tarsal Bones/diagnostic imaging , Tomography, X-Ray Computed
7.
Am J Sports Med ; 46(4): 801-808, 2018 03.
Article in English | MEDLINE | ID: mdl-29281797

ABSTRACT

BACKGROUND: Superior capsular reconstruction (SCR) was recently introduced as a treatment for irreparable superior rotator cuff tears in younger patients. Purpose/Hypothesis: The purpose was to assess the biomechanical strength of 3 methods for fixation of the graft to the glenoid for SCR. It was hypothesized that a 4-anchor technique would provide greater load to failure than 3-anchor techniques. STUDY DESIGN: Controlled laboratory study. METHODS: Thirty-six cadaveric specimens were randomized into 3 groups of previously established glenoid-side graft fixation techniques: (1) three 3.5-mm knotless screw-in anchors, (2) three 3.0-mm knotless push-in anchors, and (3) a 4-anchor hybrid construct with two 3.0-mm knotted push-in anchors and two 2.9-mm knotless push-in anchors. The repairs were cyclically loaded at 0.5 Hz from 10 to 200 N, then pulled to failure. Elongation, stiffness, maximum load at failure, and mode of failure were recorded and calculated. RESULTS: There were no significant differences in graft elongation or stiffness among the 3 techniques ( P > .37 and P > .26, respectively). Maximum load to failure was significantly greater in technique 1 (mean ± SD, 427.85 ± 119.70 N) than technique 3 (319.5 ± 57.60 N) ( P = 0.024). There were no significant differences in load to failure between techniques 1 and 2 or between techniques 2 and 3. CONCLUSION: Glenoid-side graft fixation with 3 threaded 3.5-mm suture anchors showed a significant superior pull-out strength when compared with a 4-anchor hybrid technique and thus might be recommended in SCR for patients with irreparable superior rotator cuff tears to achieve maximum stability. CLINICAL RELEVANCE: SCR presents a novel alternative for treatment of irreparable superior rotator cuff tears in younger patients. Glenoid fixation is essential to provide adequate fixation of the graft to prevent the humeral head from rising and to restore normal biomechanics.


Subject(s)
Rotator Cuff Injuries/surgery , Rotator Cuff/surgery , Suture Anchors , Biomechanical Phenomena , Bone Screws , Cadaver , Female , Humans , Humeral Head/surgery , Male , Middle Aged , Scapula/surgery , Suture Techniques , Transplants/surgery
8.
Orthop J Sports Med ; 5(5): 2325967117708190, 2017 May.
Article in English | MEDLINE | ID: mdl-28607939

ABSTRACT

BACKGROUND: A subset of patients have clinical internal and/or external knee rotational instability despite no apparent injury to the cruciate or collateral ligaments. PURPOSE/HYPOTHESIS: The purpose of this study was to assess the effect of sequentially cutting the posterolateral, anterolateral, posteromedial, and anteromedial structures of the knee on rotational stability in the setting of intact cruciate and collateral ligaments. It was hypothesized that cutting of the iliotibial band (ITB), anterolateral ligament and lateral capsule (ALL/LC), posterior oblique ligament (POL), and posteromedial capsule (PMC) would significantly increase internal rotation, while sectioning of the anteromedial capsule (AMC) and the popliteus tendon and popliteofibular ligament (PLT/PFL) would lead to a significant increase in external knee rotation. STUDY DESIGN: Controlled laboratory study. METHODS: Ten pairs (N = 20) of cadaveric knees were assigned to 2 sequential cutting groups (group 1: posterolateral-to-posteromedial [PL → PM] and group 2: posteromedial-to-posterolateral [PM → PL]). Specimens were subjected to applied 5-N·m internal and external rotation torques at knee flexion angles of 0°, 30°, 60°, and 90° while intact and after each cut state. Rotational changes were measured and compared with the intact and previous cut states. RESULTS: Sectioning of the ITB significantly increased internal rotation at 60° and 90° by 5.4° and 6.2° in group 1 (PL → PM) and 3.5° and 3.8° in group 2 (PM → PL). PLT/PFL complex sectioning significantly increased external rotation at 60° and 90° by 2.7° and 2.9° in group 1 (PL → PM). At 60° and 90° in group 2 (PM → PL), ALL/LC sectioning produced significant increases in internal rotation of 3.1° and 3.5°, respectively. In group 2 (PM → PL), POL sectioning produced a significant increase in internal rotation of 2.0° at 0°. AMC sectioning significantly increased external rotation at 30° to 90° of flexion with a magnitude of change of <1° in both groups 1 (PL → PM) and 2 (PM → PL). CONCLUSION: Collectively, the anterolateral corner structures provided primary internal rotation control of the knee from 60° to 90° of knee flexion in knees with intact cruciate and collateral ligaments. The ITB was the most significant primary stabilizer of internal rotation. The POL had a primary role for internal rotational stability at full extension. The PLT/PFL complex was a primary stabilizer for external rotation of the knee at 60° and 90°. CLINICAL RELEVANCE: This study delineates the primary and secondary roles of the ITB, ALL/LC, POL, and PLT/PFL to rotatory stability of the knee and provides new information to understand knee rotational instabilities.

9.
Arthroscopy ; 33(6): 1131-1137, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28049593

ABSTRACT

PURPOSE: To investigate glenoid fixation for superior capsule reconstruction (SCR) and evaluate anchor positions, intraosseous trajectories, and proximity to the suprascapular nerve (SSN) and glenoid fossa. The secondary purpose was to provide technical pearls and pitfalls for anchor insertion on the superior glenoid during SCR. METHODS: Three beath pins were arthroscopically inserted into 12 (n = 12) nonpaired human cadaveric shoulders through Neviaser, anterior, and posterior portals to simulate anchor placement on the superior glenoid during SCR. Computed tomography scans were performed to evaluate anchor positioning and insertion trajectories. Specimens were then dissected to delineate the anatomic relations of the beath pins to the SSN and glenoid fossa. RESULTS: The superior glenoid anchor position was a mean 15.0 ± 4.0 mm to the SSN and 6.5 ± 1.7 mm to the glenoid fossa. The posterior glenoid anchor position was a mean 11.8 ± 2.1 mm to the SSN and 2.9 ± 2.9 mm to the glenoid fossa. On average, the superior pin was placed at 12:30 ± 0:30 (left-sided glenoid clock face) and inserted at 19° ± 9° with respect to the sagittal plane of the glenoid, the anterior pin was placed at 11:00 ± 0:30 and inserted 40° ± 17° off the glenoid, and the posterior pin was placed at 3:00 ± 1:00 and inserted at 52° ± 12° off the glenoid. CONCLUSIONS: The results of the present cadaveric study showed that glenoid fixation was safe with respect to the SSN and delineated technical guidelines and trajectories for inserting 3 anchors into the glenoid. CLINICAL RELEVANCE: This study shows that 3 anchors can be inserted into the glenoid without a risk of SSN damage and delineates technical guidelines for anchor insertion.


Subject(s)
Glenoid Cavity/surgery , Scapula/surgery , Shoulder Joint/surgery , Adult , Aged , Arthroscopy , Bone Nails , Cadaver , Female , Glenoid Cavity/diagnostic imaging , Humans , Male , Middle Aged , Scapula/diagnostic imaging , Scapula/innervation , Shoulder Joint/diagnostic imaging , Tomography, X-Ray Computed
10.
Arthroscopy ; 33(3): 572-578, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28043749

ABSTRACT

PURPOSE: To determine the accuracy and safety of non-image-guided modified mid-anterior and anterolateral approaches to the hip joint for arthrocentesis. METHODS: Six pairs (n = 12) of human cadaveric hemipelvises underwent methylene blue hip injections through either a mid-anterior or an anterolateral approach. The distance from the mid-anterior approach to the lateral femoral cutaneous nerve (LFCN) was measured. Needle orientation was defined by a combination of 2 angles, calculated by the computer software analysis of digitized points. Distal Angle was defined as the angle between the lateral axis and an intermediate needle position, in the coronal plane, toward the distal axis. Anterior Angle was defined as the angle between the intermediate needle position of Distal Angle and the final position, toward the anterior axis. RESULTS: Methylene blue was successfully injected into the joint capsule in all specimens. The mean distances from the needle to the LFCN for both the mid-anterior and anterolateral approaches were 19.3 ± 7.9 and 80.3 ± 28.3 mm, respectively. For the mid-anterior approach, Distal AngleM was a mean of 53.9° ± 14.9° and Anterior AngleM was a mean of 33.4° ± 15.6°. For the anterolateral approach, Distal AngleL was a mean of 14.5° ± 14.2° and Anterior AngleL was a mean of 4.5° ± 13.6°. CONCLUSIONS: This study showed that mid-anterior and anterolateral approaches for non-image-guided hip injections or arthrocentesis can avoid the LFCN and be effectively performed in males, despite the exhibited variability in the quantitative descriptions of these techniques. The landmarks and measurements presented can be used as general guidelines for clinical studies regarding hip arthrocentesis and injections. CLINICAL RELEVANCE: The high variability of the needle placement and trajectory of the mid-anterior and anterolateral approaches performed in this study showed that these techniques were not easily quantitatively defined. However, both of these approaches appeared to be safe and effective.


Subject(s)
Arthrocentesis/methods , Hip Joint/anatomy & histology , Adult , Aged , Cadaver , Coloring Agents , Humans , Male , Methylene Blue , Middle Aged
11.
Foot Ankle Int ; 38(4): 436-442, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27920331

ABSTRACT

BACKGROUND: The effect of ankle positioning during suture-button fixation for syndesmosis repair on range of motion (ROM) and anatomic reduction has yet to be investigated. The purpose of this cadaveric study was to compare the effects of 3 different ankle positions during suture-button repair on volumetric reduction of the syndesmosis, fibular displacement, and ROM of the ankle using 3-dimensional computed tomography (CT) analysis. The null hypothesis was that ankle position during fixation would not affect syndesmotic volume restoration, fibular displacement, or ROM. METHODS: Twelve matched pair (n = 24) human cadaveric specimens were used for this study. Prior to syndesmotic sectioning, ROM assessment and CT scans were performed. Following sectioning of the syndesmosis, specimens were repaired in plantarflexion, dorsiflexion, or neutral, and simulated postrepair ROM evaluations and CT scans were repeated. Least squares mean differences between repair groups and the preinjury state were compared by analysis of variance and Tukey's method. RESULTS: There were no significant differences between repair groups for volumetric reduction ( P = .917), fibular displacement (anterior-posterior, P = .805; medial-lateral, P = .949), or dorsiflexion capacity ( P = .249). Among all specimens, compared with the preinjury state, there was a significant mean ± SD volume reduction of 337 ± 400 mm3 and medial displacement of 1.9 ± 1.5 mm. CONCLUSION: This study failed to reject the null hypothesis and demonstrated that ankle flexion at the time of syndesmotic fixation with a suture-button construct had no significant in vitro effect on volume changes, fibular displacement, or dorsiflexion capacity. However, in comparison to the preinjured state, suture-button repair resulted in significant overcompression with respect to syndesmosis volume and medial displacement of the fibula. CLINICAL RELEVANCE: Ankle position at the time of syndesmotic fixation did not affect overall ankle ROM when using a suture-button construct; however, overcompression was observed in all positions. The clinical impact of syndesmotic overcompression remains largely unknown.


Subject(s)
Ankle Injuries/surgery , Ankle Joint/surgery , Fibula/surgery , Fracture Fixation, Internal/methods , Range of Motion, Articular/physiology , Ankle Injuries/physiopathology , Ankle Joint/physiopathology , Humans , Suture Techniques , Tomography, X-Ray Computed
12.
Am J Sports Med ; 45(2): 434-439, 2017 02.
Article in English | MEDLINE | ID: mdl-27659939

ABSTRACT

BACKGROUND: Hip capsulotomy is routinely performed during arthroscopic surgery to achieve adequate exposure of the joint. Iatrogenic instability can result after hip arthroscopic surgery because of capsular insufficiency, which can be avoided with effective closure of the hip capsule. There is currently no consensus in the literature regarding the optimal quantity of sutures upon capsular closure to achieve maximal stability postoperatively. Purpose/Hypothesis: The purpose of this study was to determine the failure torques of 1-, 2-, and 3-suture constructs for hip capsular closure to resist external rotation and extension after standard anterosuperior interportal capsulotomy (12 to 3 o'clock). Additionally, the degree of external rotation at which the suture constructs failed was recorded. The null hypothesis of this study was that no significant differences with respect to the failure torque would be found between the 3 repair constructs. STUDY DESIGN: Controlled laboratory study. METHODS: Nine pairs (n = 18) of fresh-frozen human cadaveric hemipelvises underwent anterosuperior interportal capsulotomy, which were repaired with 1, 2, or 3 side-to-side sutures. Each hip was secured in a dynamic biaxial testing machine and underwent a cyclic external rotation preconditioning protocol, followed by external rotation to failure. RESULTS: The failure torque of the 1-suture hip capsular closure construct was significantly less than that of the 3-suture construct. The median failure torque for the 1-suture construct was 67.4 N·m (range, 47.4-73.6 N·m). The median failure torque was 85.7 N·m (range, 56.9-99.1 N·m) for the 2-suture construct and 91.7 N·m (range, 74.7-99.0 N·m) for the 3-suture construct. All 3 repair constructs exhibited a median 36° (range, 22°-64°) of external rotation at the failure torque. CONCLUSION: The most important finding of this study was that the 2- and 3-suture constructs resulted in comparable biomechanical failure torques when external rotation forces were applied to conventional hip capsulotomy in a cadaveric model. The 3-suture construct was significantly stronger than the 1-suture construct; however, there was not a significant difference between the 2- and 3-suture constructs. Additionally, all constructs failed at approximately 36° of external rotation. CLINICAL RELEVANCE: Re-establishing the native anatomy of the hip capsule after hip arthroscopic surgery has been reported to result in improved outcomes and reduce the risk of iatrogenic instability. Therefore, adequate capsular closure is important to restore proper hip biomechanics, and postoperative precautions limiting external rotation should be utilized to protect the repair.


Subject(s)
Arthroscopy/methods , Hip Joint/surgery , Suture Techniques , Adult , Aged , Biomechanical Phenomena , Cadaver , Humans , Male , Middle Aged , Rotation , Torque
13.
Foot Ankle Int ; 38(2): 208-214, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27733556

ABSTRACT

BACKGROUND: Historically, syndesmosis injuries have been repaired with screw fixation; however, some suggest that suture-button constructs may provide a more accurate anatomic and physiologic reduction. The purpose of this study was to compare changes in the volume of the syndesmotic space following screw or suture-button fixation using a preinjury and postoperative 3-D computed tomography (CT) model. The null hypothesis was that no difference would be observed among repair techniques. METHODS: Twelve pairs of cadaveric specimens were dissected to identify the syndesmotic ligaments. Specimens were imaged with CT prior to the creation of a complete syndesmosis injury and were subsequently repaired using 1 of 3 randomly assigned techniques: (a) one 3.5-mm cortical screw, (b) 1 suture-button, and (c) 2 suture-buttons. Specimens were imaged postoperatively with CT. 3-D models of all scans and tibiofibular joint space volumes were calculated to assess restoration of the native syndesmosis. Analysis of variance and Tukey's method were used to compare least squares mean differences from the intact syndesmosis among repair techniques. RESULTS: For each of the 3 fixation methods, the total postoperative syndesmosis volume was significantly decreased relative to the intact state. The total mean decreases in volume compared with the intact state for the 1-suture-button construct, 2-suture-button construct, and syndesmotic screw were -561 mm3 (95% CI, -878 to -244), -964 mm3 (95% CI, -1281 to -647) and -377 mm3 (95% CI, -694 to -60), respectively. CONCLUSION: All repairs notably reduced the volume of the syndesmosis beyond the intact state. Fixation with 1 suture-button was not significantly different from screw or 2-suture-button fixation; however, fixation with 2 suture-buttons resulted in significantly decreased volume compared with screw fixation. CLINICAL RELEVANCE: The results of this study suggest that the 1-suture-button repair technique and the screw fixation repair technique were comparable for reduction of syndesmosis injuries, although both may overcompress the syndesmosis.


Subject(s)
Ankle Injuries/surgery , Ankle Joint/anatomy & histology , Bone Screws , Orthopedic Procedures/methods , Suture Anchors , Adult , Ankle Injuries/diagnostic imaging , Ankle Injuries/pathology , Ankle Joint/surgery , Cadaver , Fibula/anatomy & histology , Fibula/surgery , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Tibia/anatomy & histology , Tibia/surgery , Tomography, X-Ray Computed
16.
J Wrist Surg ; 5(4): 265-272, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27777816

ABSTRACT

Background Scapholunate advanced collapse and scaphoid nonunion advanced collapse result in high morbidity and pose significant challenges for active patients. Multiple treatment options have been proposed to yield satisfactory results; however, restoration of physiological wrist motion remains an issue. Questions/Purposes The objective of this study was to compare wrist mobility after four different treatment methods for grade III wrist collapse: (1) no treatment, (2) scaphoidectomy and lunate-capitate arthrodesis, (3) scaphoidectomy, lunate-capitate arthrodesis, and triquetrum-hamate arthrodesis, and (4) scaphoidectomy, lunate-capitate arthrodesis, and triquetrum excision. Methods Four paired (n = 8) fresh-frozen human cadaveric upper limbs were used in this controlled laboratory study. Computed tomography scans were collected at all testing states and measurements were made to evaluate midcarpal joint mobility and alignment. Results A significant decrease in wrist extension was observed for all treatments. Middle column and two-column arthrodesis demonstrated no significant differences for carpal alignment and mobility. No significant differences were observed for triquetrum-hamate mobility or wrist extension between the partial and two-column arthrodesis. Triquetrum excision significantly improved ulnar deviation. Conclusion The most important finding of this study was that the one-column arthrodesis has comparable carpal alignment and range of motion to that of bi-column arthrodesis. Clinical Relevance The results of this study suggest that a stage III advanced wrist collapse can be treated by isolated lunate-capitate arthrodesis with scaphoidectomy. Fusion between the remaining carpal bones may not be necessary because the carpal alignment and range of motion of the remaining joints were not significantly different in the present study.

17.
Am J Sports Med ; 44(10): 2546-2556, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27407088

ABSTRACT

BACKGROUND: Anterior cruciate ligament (ACL) tears are one of the most common injuries among athletes. However, the ability to fully restore rotational stability with ACL reconstruction (ACLR) remains a challenge, as evidenced by the persistence of rotational instability in up to 25% of patients after surgery. Advocacy for reconstruction of the anterolateral ligament (ALL) is rapidly increasing because some biomechanical studies have reported that the ALL is a significant contributor to internal rotational stability of the knee. HYPOTHESIS/PURPOSE: The purpose of this study was to assess the effect of ALL reconstruction (ALLR) graft fixation angle on knee joint kinematics in the clinically relevant setting of a concomitant ACLR and to determine the optimal ALLR graft fixation angle. It was hypothesized that all fixation angles would significantly reduce rotational laxity compared with the sectioned ALL state. STUDY DESIGN: Controlled laboratory study. METHODS: Ten nonpaired fresh-frozen human cadaveric knees underwent a full kinematic assessment in each of the following states: (1) intact; (2) anatomic single-bundle (SB) ACLR with intact ALL; (3) anatomic SB ACLR with sectioned ALL; (4) anatomic SB ACLR with 7 anatomic ALLR states using graft fixation angles of 0°, 15°, 30°, 45°, 60°, 75°, and 90°; and (5) sectioned ACL and ALL. Internal rotation during a 5-N·m internal rotation torque and anterior translation during an 88-N anterior load were recorded at 15° flexion intervals between 0° and 120°. Axial plane translation and internal rotation during a simulated pivot-shift test (combined 5-N·m internal rotation and 10-N·m valgus torques) were recorded between 0° and 60°. Kinematic changes were measured and compared with the intact state for all reconstructed and sectioned states. RESULTS: Anatomic ALLR at all graft fixation angles significantly overconstrained internal rotation of the knee joint beyond 30° of flexion and at 45° and 60° during the pivot-shift test. Furthermore, there were no significant knee kinematic differences between any tested graft fixation angles during anterior drawer, pivot-shift, and internal rotation tests. CONCLUSION: Anatomic ALLR in conjunction with an ACLR significantly reduced rotatory laxity of the knee beyond 30° of knee flexion. However, ALLR, regardless of fixation angle, resulted in significant overconstraint of the knee. CLINICAL RELEVANCE: ALLR at any fixation angle overconstrained native joint kinematics and should be performed with careful consideration. Further investigation into the application and target population for ALLR is strongly recommended.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Joint Instability/physiopathology , Knee Joint/physiology , Transplants/surgery , Athletes , Biomechanical Phenomena , Cadaver , Humans , Male , Middle Aged , Range of Motion, Articular
18.
Arthroscopy ; 32(12): 2592-2611, 2016 12.
Article in English | MEDLINE | ID: mdl-27324970

ABSTRACT

PURPOSE: To systematically review and compare biomechanical results of lateral extra-articular tenodesis (LET) procedures. METHODS: A systematic review was performed using the PubMed, Medline, Embase, and Cochrane databases. The search terms included the following: extraarticular, anterolateral, iliotibial, tenodesis, plasty, augmentation, procedure, reconstruction, technique, biomechanics, kinematic, robot, cadaver, knee, lateral tenodesis, ACL, Marcacci, Lemaire, Losee, Macintosh, Ellison, Andrews, Hughston, and Muller. The inclusion criteria were nonanatomic, in vitro biomechanical studies, defined as in vitro investigations of joint motion resulting from controlled, applied forces. RESULTS: Of the 10 included studies, 7 analyzed anterior tibial translation and reported that isolated LET procedures did not restore normal anterior stability to the anterior cruciate ligament (ACL)-deficient knee. Seven of the 8 studies analyzing tibial rotation reported a reduction in internal tibial rotation across various flexion angles in the ACL-deficient knee when compared with the native state. Five studies reported a reduction in intra-articular graft force with the addition of an LET. Two studies evaluated length change patterns, graft course, and total strain range and found that reconstruction techniques in which the graft attached proximal to the lateral epicondyle and coursed deep to the fibular collateral ligament were most isometric. CONCLUSIONS: In the ACL-deficient knee, LET procedures overconstrained the knee and restricted internal tibial rotation when compared with the native state. In addition, isolated LET procedures did not return normal anterior stability to the ACL-deficient knee but did significantly reduce anterior tibial translation and intra-articular graft forces during anteriorly directed loading. CLINICAL RELEVANCE: Combined injury to the ACL and anterolateral structures has been reported to exhibit greater anterolateral rotatory instability when compared with isolated ACL injuries. Despite the reported risk of joint over-constraint, consideration should be given to reconstructing the anterolateral structures and the ACL concurrently to maximally restore both anterior tibial translation and rotatory stability.


Subject(s)
Anterior Cruciate Ligament Injuries/surgery , Joint Instability/surgery , Knee Joint/surgery , Plastic Surgery Procedures/methods , Tenodesis/methods , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries/physiopathology , Biomechanical Phenomena , Cadaver , Humans , Joint Instability/physiopathology , Knee Joint/physiopathology , Range of Motion, Articular , Rotation , Tibia/surgery , Transplants , Treatment Outcome
19.
J Exp Orthop ; 3(1): 10, 2016 Dec.
Article in English | MEDLINE | ID: mdl-26928558

ABSTRACT

BACKGROUND: The purpose of this study was to quantify the meniscal root anatomy of the New Zealand white rabbit to better understand this animal model for future in vitro and in vivo joint degeneration studies. METHODS: Ten non-paired fresh frozen New Zealand white rabbit knee stifle joints were carefully disarticulated for this study. Measurements were made for all bony landmarks and ligamentous structure attachment sites on the tibial plateau. The following soft tissue structures were consistently identified in the rabbit stifle joint: the anterior root attachment of the lateral meniscus, the anterior root attachment of the medial meniscus, the anterior cruciate ligament, the posterior root attachment of the medial meniscus, the ligament of Wrisberg, the posterior cruciate ligament, and the posterior meniscotibial ligament. The following bony landmarks were consistently identified: the extensor digitorum longus groove, the medial tibial eminence, the center of the tibial tuberosity, and the lateral tibial eminence. RESULTS: The center of the anterior cruciate ligament and the medial tibial eminence apex were found to be 3.4 ± 0.3 mm (2.9-3.6) and 6.1 ± 0.6 mm (5.1-7.0) respectively from the center of the medical anterior root attachment. The center of the anterior cruciate ligament and the lateral tibial eminence apex were found to be 2.1 ± 0.5 mm (1.2-2.7) and 7.0 ± 0.6 mm (6.4-8.2) respectively from the center of the lateral anterior root attachment. The center of the posterior cruciate ligament and the medial tibial eminence apex were found to be 2.0 ± 0.7 mm (0.5-2.6) and 1.8 ± 0.4 mm (1.2-2.4) respectively from the center of the medial posterior root attachment. CONCLUSIONS: This study augments our understanding of the comparative anatomy of the rabbit stifle joint. This information will be useful for future biomechanical, surgical, and in vitro studies utilizing the rabbit stifle as a model for human knee joint degenerative diseases.