Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters








Database
Language
Publication year range
1.
Sensors (Basel) ; 24(13)2024 Jun 24.
Article in English | MEDLINE | ID: mdl-39000886

ABSTRACT

Wireless sensor networks (WSNs) are attracting increasing research interest due to their ability to monitor large areas independently. Their reliability is a crucial issue, as it is influenced by hardware, data, and energy-related factors such as loading conditions, signal attenuation, and battery lifetime. Proper selection of sensor node positions is essential to maximise system reliability during the development of products equipped with WSNs. For this purpose, this paper presents an approach to estimate WSN system reliability during the development phase based on the analysis of measurements, using strain measurements in finite element (FE) models as an example. The approach involves dividing the part under consideration into regions with similar strains using a region growing algorithm (RGA). The WSN configuration is then analysed for reliability based on data paths and measurement redundancy resulting from the sensor positions in the identified measuring regions. This methodology was tested on an exemplary WSN configuration at an aircraft wing box under bending load and found to effectively estimate the hardware perspective on system reliability. Therefore, the methodology and algorithm show potential for optimising sensor node positions to achieve better reliability results.

2.
Sci Rep ; 14(1): 5719, 2024 03 08.
Article in English | MEDLINE | ID: mdl-38459092

ABSTRACT

Prosthetic implants, particularly hip endoprostheses, often lead to stress shielding because of a mismatch in compliance between the bone and the implant material, adversely affecting the implant's longevity and effectiveness. Therefore, this work aimed to demonstrate a computationally efficient method for density-based topology optimization of homogenized lattice structures in a patient-specific hip endoprosthesis. Thus, the root mean square error (RMSE) of the stress deviations between the physiological femur model and the optimized total hip arthroplasty (THA) model compared to an unoptimized-THA model could be reduced by 81 % and 66 % in Gruen zone (GZ) 6 and 7. However, the method relies on homogenized finite element (FE) models that only use a simplified representation of the microstructural geometry of the bone and implant. The topology-optimized hip endoprosthesis with graded lattice structures was synthesized using algorithmic design and analyzed in a virtual implanted state using micro-finite element (micro-FE) analysis to validate the optimization method. Homogenized FE and micro-FE models were compared based on averaged von Mises stresses in multiple regions of interest. A strong correlation (CCC > 0.97) was observed, indicating that optimizing homogenized lattice structures yields reliable outcomes. The graded implant was additively manufactured to ensure the topology-optimized result's feasibility.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Prosthesis Design , Arthroplasty, Replacement, Hip/methods , Femur , Finite Element Analysis , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL