Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add more filters








Publication year range
1.
Nanotechnology ; 2024 Oct 12.
Article in English | MEDLINE | ID: mdl-39395441

ABSTRACT

Magnetic nanoparticles (MNPs) represent a class of small particles typically with diameters ranging from 1 to 100 nanometers. These nanoparticles are composed of magnetic materials such as iron, cobalt, nickel, or their alloys. The nanoscale size of MNPs gives them unique physicochemical (physical and chemical) properties not found in their bulk counterparts. Their versatile nature and unique magnetic behavior make them valuable in a wide range of scientific, medical, and technological fields. Over the past decade, there has been a significant surge in MNP-based applications spanning biomedical uses, environmental remediation, data storage, energy storage, and catalysis. Given their magnetic nature and small size, MNPs can be manipulated and guided using external magnetic fields. This characteristic is harnessed in biomedical applications, where these nanoparticles can be directed to specific targets in the body for imaging, drug delivery, or hyperthermia treatment. Herein, this roadmap offers an overview of the current status, challenges, and advancements in various facets of MNPs. It covers magnetic properties, synthesis, functionalization, characterization, and biomedical applications such as sample enrichment, bioassays, imaging, hyperthermia, neuromodulation, tissue engineering, and drug/gene delivery. However, as MNPs are increasingly explored for in vivo applications, concerns have emerged regarding their cytotoxicity, cellular uptake, and degradation, prompting attention from both researchers and clinicians. This roadmap aims to provide a comprehensive perspective on the evolving landscape of MNP research.

2.
Small ; : e2403283, 2024 Aug 07.
Article in English | MEDLINE | ID: mdl-39108190

ABSTRACT

Superparamagnetic iron oxide nanoparticles (SPIOs) are used as tracers in Magnetic Particle Imaging (MPI). It is crucial to understand the magnetic properties of SPIOs for optimizing MPI imaging contrast, resolution, and sensitivity. Brownian and Néel relaxation theory developed in the early 1950s posits that relaxation times can vary with particle size, shell thickness, medium viscosity, and the applied field strength. Magnetic relaxation can soon provide a unique imaging capability, the ability to distinguish bound from unbound MPI tracers in vivo. Yet experimental validation of these theories has not been completed. In this paper, a novel method of pulsed magnetic field relaxometry is used to directly probe the relaxation behavior of superparamagnetic magnetite nanoparticles over a spectrum of magnetic field amplitudes, providing the first experimental validation of theoretical relaxation models. It is also shown that closed-form approximations generated in the early 1970s accurately match both data and numerical Fokker Planck computational models, which are computationally burdensome. This means researchers can trust these approximations for future modeling. All the findings can be translated to sinusoidal excitations used in conventional MPI scanning trajectories.

3.
Nanoscale ; 16(25): 11802-11824, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38809214

ABSTRACT

Recent advancements in medical imaging have brought forth various techniques such as magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), and ultrasound, each contributing to improved diagnostic capabilities. Most recently, magnetic particle imaging (MPI) has become a rapidly advancing imaging modality with profound implications for medical diagnostics and therapeutics. By directly detecting the magnetization response of magnetic tracers, MPI surpasses conventional imaging modalities in sensitivity and quantifiability, particularly in stem cell tracking applications. Herein, this comprehensive review explores the fundamental principles, instrumentation, magnetic nanoparticle tracer design, and applications of MPI, offering insights into recent advancements and future directions. Novel tracer designs, such as zinc-doped iron oxide nanoparticles (Zn-IONPs), exhibit enhanced performance, broadening MPI's utility. Spatial encoding strategies, scanning trajectories, and instrumentation innovations are elucidated, illuminating the technical underpinnings of MPI's evolution. Moreover, integrating machine learning and deep learning methods enhances MPI's image processing capabilities, paving the way for more efficient segmentation, quantification, and reconstruction. The potential of superferromagnetic iron oxide nanoparticle chains (SFMIOs) as new MPI tracers further advanced the imaging quality and expanded clinical applications, underscoring the promising future of this emerging imaging modality.


Subject(s)
Magnetite Nanoparticles , Humans , Magnetite Nanoparticles/chemistry , Magnetic Resonance Imaging/methods , Animals , Magnetic Iron Oxide Nanoparticles/chemistry , Positron-Emission Tomography , Contrast Media/chemistry
4.
Small Methods ; 5(11): e2100796, 2021 11.
Article in English | MEDLINE | ID: mdl-34927972

ABSTRACT

Magnetic nanoparticles have many advantages in medicine such as their use in non-invasive imaging as a Magnetic Particle Imaging (MPI) tracer or Magnetic Resonance Imaging contrast agent, the ability to be externally shifted or actuated and externally excited to generate heat or release drugs for therapy. Existing nanoparticles have a gentle sigmoidal magnetization response that limits resolution and sensitivity. Here it is shown that superferromagnetic iron oxide nanoparticle chains (SFMIOs) achieve an ideal step-like magnetization response to improve both image resolution & SNR by more than tenfold over conventional MPI. The underlying mechanism relies on dynamic magnetization with square-like hysteresis loops in response to 20 kHz, 15 kAm-1 MPI excitation, with nanoparticles assembling into a chain under an applied magnetic field. Experimental data shows a "1D avalanche" dipole reversal of every nanoparticle in the chain when the applied field overcomes the dynamic coercive threshold of dipole-dipole fields from adjacent nanoparticles in the chain. Intense inductive signal is produced from this event resulting in a sharp signal peak. Novel MPI imaging strategies are demonstrated to harness this behavior towards order-of-magnitude medical image improvements. SFMIOs can provide a breakthrough in noninvasive imaging of cancer, pulmonary embolism, gastrointestinal bleeds, stroke, and inflammation imaging.


Subject(s)
Magnetite Nanoparticles/chemistry , Mesenchymal Stem Cells/cytology , Cells, Cultured , Humans , Magnetic Resonance Imaging , Mesenchymal Stem Cells/chemistry
5.
Cancers (Basel) ; 13(21)2021 Oct 21.
Article in English | MEDLINE | ID: mdl-34771448

ABSTRACT

BACKGROUND: Magnetic Particle Imaging (MPI) is an emerging imaging modality for quantitative direct imaging of superparamagnetic iron oxide nanoparticles (SPION or SPIO). With different physics from MRI, MPI benefits from ideal image contrast with zero background tissue signal. This enables clear visualization of cancer with image characteristics similar to PET or SPECT, but using radiation-free magnetic nanoparticles instead, with infinite-duration reporter persistence in vivo. MPI for cancer imaging: demonstrated months of quantitative imaging of the cancer-related immune response with in situ SPION-labelling of immune cells (e.g., neutrophils, CAR T-cells). Because MPI suffers absolutely no susceptibility artifacts in the lung, immuno-MPI could soon provide completely noninvasive early-stage diagnosis and treatment monitoring of lung cancers. MPI for magnetic steering: MPI gradients are ~150 × stronger than MRI, enabling remote magnetic steering of magneto-aerosol, nanoparticles, and catheter tips, enhancing therapeutic delivery by magnetic means. MPI for precision therapy: gradients enable focusing of magnetic hyperthermia and magnetic-actuated drug release with up to 2 mm precision. The extent of drug release from the magnetic nanocarrier can be quantitatively monitored by MPI of SPION's MPS spectral changes within the nanocarrier. CONCLUSION: MPI is a promising new magnetic modality spanning cancer imaging to guided-therapy.

6.
Nanotheranostics ; 5(2): 240-255, 2021.
Article in English | MEDLINE | ID: mdl-33614400

ABSTRACT

White blood cells (WBCs) are a key component of the mammalian immune system and play an essential role in surveillance, defense, and adaptation against foreign pathogens. Apart from their roles in the active combat of infection and the development of adaptive immunity, immune cells are also involved in tumor development and metastasis. Antibody-based therapeutics have been developed to regulate (i.e. selectively activate or inhibit immune function) and harness immune cells to fight malignancy. Alternatively, non-invasive tracking of WBC distribution can diagnose inflammation, infection, fevers of unknown origin (FUOs), and cancer. Magnetic Particle Imaging (MPI) is a non-invasive, non-radioactive, and sensitive medical imaging technique that uses safe superparamagnetic iron oxide nanoparticles (SPIOs) as tracers. MPI has previously been shown to track therapeutic stem cells for over 87 days with a ~200 cell detection limit. In the current work, we utilized antibody-conjugated SPIOs specific to neutrophils for in situ labeling, and non-invasive and radiation-free tracking of these inflammatory cells to sites of infection and inflammation in an in vivo murine model of lipopolysaccharide-induced myositis. MPI showed sensitive detection of inflammation with a contrast-to-noise ratio of ~8-13.


Subject(s)
Cell Tracking/methods , Magnetics , Neutrophils/cytology , Humans
7.
Theranostics ; 10(7): 2965-2981, 2020.
Article in English | MEDLINE | ID: mdl-32194849

ABSTRACT

Magnetic fluid hyperthermia (MFH) treatment makes use of a suspension of superparamagnetic iron oxide nanoparticles, administered systemically or locally, in combination with an externally applied alternating magnetic field, to ablate target tissue by generating heat through a process called induction. The heat generated above the mammalian euthermic temperature of 37°C induces apoptotic cell death and/or enhances the susceptibility of the target tissue to other therapies such as radiation and chemotherapy. While most hyperthermia techniques currently in development are targeted towards cancer treatment, hyperthermia is also used to treat restenosis, to remove plaques, to ablate nerves and to alleviate pain by increasing regional blood flow. While RF hyperthermia can be directed invasively towards the site of treatment, non-invasive localization of heat through induction is challenging. In this review, we discuss recent progress in the field of RF magnetic fluid hyperthermia and introduce a new diagnostic imaging modality called magnetic particle imaging that allows for a focused theranostic approach encompassing treatment planning, treatment monitoring and spatially localized inductive heating.


Subject(s)
Diagnostic Imaging/methods , Ferric Compounds/analysis , Hyperthermia, Induced/methods , Magnetic Iron Oxide Nanoparticles/analysis , Radiofrequency Therapy/methods , Theranostic Nanomedicine/methods , Animals , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/therapy , Coated Materials, Biocompatible , Diagnostic Imaging/instrumentation , Equipment Design , Ferric Compounds/administration & dosage , Forecasting , Humans , Hyperthermia, Induced/instrumentation , Magnetic Iron Oxide Nanoparticles/administration & dosage , Magnetics/instrumentation , Male , Mice , Pilot Projects , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/therapy
8.
Int J Hyperthermia ; 37(3): 141-154, 2020 12.
Article in English | MEDLINE | ID: mdl-33426994

ABSTRACT

Magnetic fluid hyperthermia (MFH) has been widely investigated as a treatment tool for cancer and other diseases. However, focusing traditional MFH to a tumor deep in the body is not feasible because the in vivo wavelength of 300 kHz very low frequency (VLF) excitation fields is longer than 100 m. Recently we demonstrated that millimeter-precision localized heating can be achieved by combining magnetic particle imaging (MPI) with MFH. In principle, real-time MPI imaging can also guide the location and dosing of MFH treatments. Hence, the combination of MPI imaging plus real time localized MPI-MFH could soon permit closed-loop high-resolution hyperthermia treatment. In this review, we will discuss the fundamentals of localized MFH (e.g. physics and biosafety limitations), hardware implementation, MPI real-time guidance, and new research directions on MPI-MFH. We will also discuss how the scale up to human-sized MPI-MFH scanners could proceed.


Subject(s)
Hyperthermia, Induced , Magnetite Nanoparticles , Diagnostic Imaging , Humans , Hyperthermia , Magnetic Fields , Magnetics
9.
ESC Heart Fail ; 7(1): 92-102, 2020 02.
Article in English | MEDLINE | ID: mdl-31851785

ABSTRACT

AIMS: A significant proportion of heart failure (HF) patients have HF preserved ejection fraction (HFpEF). The lack of effective treatments for HFpEF remains a critical unmet need. A key obstacle to therapeutic innovation in HFpEF is the paucity of pre-clinical models. Although several large animal models have been reported, few demonstrate progression to decompensated HF. We have established a model of HFpEF by enhancing a porcine model of progressive left ventricular (LV) pressure overload and characterized HF in this model including advanced cardiometabolic imaging using cardiac magnetic resonance imaging and hyperpolarized carbon-13 magnetic resonance spectroscopy. METHODS AND RESULTS: Pigs underwent progressive LV pressure overload by means of an inflatable aortic cuff. Pigs developed LV hypertrophy (50% increase in wall thickness, P < 0.001, and two-fold increase in mass compared to sham control, P < 0.001) with no evidence of LV dilatation but a significant increase in left atrial volume (P = 0.013). Cardiac magnetic resonance imaging demonstrated T1 modified Look-Locker inversion recovery values increased in 16/17 segments compared to sham pigs (P < 0.05-P < 0.001) indicating global ventricular fibrosis. Mean LV end-diastolic (P = 0.047) and pulmonary capillary wedge pressures (P = 0.008) were elevated compared with sham control. One-third of the pigs demonstrated clinical signs of frank decompensated HF, and mean plasma BNP concentrations were raised compared with sham control (P = 0.008). Cardiometabolic imaging with hyperpolarized carbon-13 magnetic resonance spectroscopy agreed with known metabolic changes in the failing heart with a switch from fatty acid towards glucose substrate utilization. CONCLUSIONS: Progressive aortic constriction in growing pigs induces significant LV hypertrophy with cardiac fibrosis associated with left atrial dilation, raised filling pressures, and an ability to transition to overt HF with raised BNP without reduction in LVEF. This model replicates many aspects of clinical HFpEF with a predominant background of hypertension and can be used to advance understanding of underlying pathology and for necessary pre-clinical testing of novel candidate therapies.


Subject(s)
Heart Failure , Magnetic Resonance Imaging , Animals , Disease Models, Animal , Female , Heart Failure/diagnosis , Humans , Stroke Volume , Swine
10.
IEEE Trans Med Imaging ; 39(5): 1724-1734, 2020 05.
Article in English | MEDLINE | ID: mdl-31796392

ABSTRACT

Magnetic Particle Imaging is an emerging tracer imaging modality with zero background signal and zero ionizing radiation, high contrast and high sensitivity with quantitative images. While there is recent work showing that the low amplitude or low frequency drive parameters can improve MPI's spatial resolution by mitigating relaxation losses, the concomitant decrease of the MPI's tracer sensitivity due to the lower drive slew rates was not fully addressed. There has yet to be a wide parameter space, multi-objective optimization of MPI drive parameters for high resolution, high sensitivity and safety. In a large-scale study, we experimentally test 5 different nanoparticles ranging from multi to single-core across 18.5 nm to 32.1 nm core sizes and across an expansive drive parameter range of 0.4 - 416 kHz and 0.5 - 40 mT/ µ0 to assess spatial resolution, SNR, and safety. In addition, we analyze how drive-parameter-dependent shifts in harmonic signal energy away and towards the discarded first harmonic affect effective SNR in this optimization study. The results show that when optimizing for all four factors of resolution, SNR, discarded-harmonic-energy and safety, the overall trends are no longer monotonic and clear optimal points emerge. We present drive parameters different from conventional preclinical MPI showing ~ 2-fold improvement in spatial resolution while remaining within safety limits and addressing sensitivity by minimizing the typical SNR loss involved. Finally, validation of the optimization results with 2D images of phantoms was performed.


Subject(s)
Nanoparticles , Tomography , Magnetic Phenomena , Phantoms, Imaging
11.
IEEE Trans Med Imaging ; 38(10): 2389-2399, 2019 10.
Article in English | MEDLINE | ID: mdl-30762537

ABSTRACT

Magnetic particle imaging (MPI) is a promising new tracer-based imaging modality. The steady-state, nonlinear magnetization physics most fundamental to MPI typically predicts improving resolution with increasing tracer magnetic core size. For larger tracers, and given typical excitation slew rates, this steady-state prediction is compromised by dynamic processes that induce a significant secondary blur and prevent us from achieving high resolution using larger tracers. Here, we propose a new method of excitation and signal encoding in MPI we call pulsed MPI to overcome this phenomenon. Pulsed MPI allows us to directly encode the steady-state magnetic physics into the time-domain signal. This in turn gives rise to a simple reconstruction algorithm to obtain images free of secondary relaxation-induced blur. Here, we provide a detailed description of our approach in 1D, discuss how it compares with alternative approaches, and show experimental data demonstrating better than 500- [Formula: see text] resolution (at 7 T/m) with large tracers. Finally, we show experimental images from a 2D implementation.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetite Nanoparticles/chemistry , Molecular Imaging/methods , Algorithms , Phantoms, Imaging
12.
Theranostics ; 8(13): 3676-3687, 2018.
Article in English | MEDLINE | ID: mdl-30026874

ABSTRACT

Pulmonary delivery of therapeutics is attractive due to rapid absorption and non-invasiveness but it is challenging to monitor and quantify the delivered aerosol or powder. Currently, single-photon emission computed tomography (SPECT) is used but requires inhalation of radioactive labels that typically have to be synthesized and attached by hot chemistry techniques just prior to every scan. Methods: In this work, we demonstrate that superparamagnetic iron oxide nanoparticles (SPIONs) can be used to label and track aerosols in vivo with high sensitivity using an emerging medical imaging technique known as magnetic particle imaging (MPI). We perform proof-of-concept experiments with SPIONs for various lung applications such as evaluation of efficiency and uniformity of aerosol delivery, tracking of the initial aerosolized therapeutic deposition in vivo, and finally, sensitive visualization of the entire mucociliary clearance pathway from the lung up to the epiglottis and down the gastrointestinal tract to be excreted. Results: Imaging of SPIONs in the lung has previously been limited by difficulty of lung imaging with magnetic resonance imaging (MRI). In our results, MPI enabled SPION lung imaging with high sensitivity, and a key implication is the potential combination with magnetic actuation or hyperthermia for MPI-guided therapy in the lung with SPIONs. Conclusion: This work shows how magnetic particle imaging can be enabling for new imaging and therapeutic applications of SPIONs in the lung.


Subject(s)
Administration, Inhalation , Aerosols/administration & dosage , Diagnostic Imaging/methods , Ferric Compounds/pharmacokinetics , Pharmaceutical Preparations/administration & dosage , Animals , Ferric Compounds/administration & dosage , Four-Dimensional Computed Tomography/methods , Metal Nanoparticles , Mice
13.
Br J Radiol ; 91(1091): 20180326, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29888968

ABSTRACT

Magnetic particle imaging (MPI), introduced at the beginning of the twenty-first century, is emerging as a promising diagnostic tool in addition to the current repertoire of medical imaging modalities. Using superparamagnetic iron oxide nanoparticles (SPIOs), that are available for clinical use, MPI produces high contrast and highly sensitive tomographic images with absolute quantitation, no tissue attenuation at-depth, and there are no view limitations. The MPI signal is governed by the Brownian and Néel relaxation behavior of the particles. The relaxation time constants of these particles can be utilized to map information relating to the local microenvironment, such as viscosity and temperature. Proof-of-concept pre-clinical studies have shown favourable applications of MPI for better understanding the pathophysiology associated with vascular defects, tracking cell-based therapies and nanotheranostics. Functional imaging techniques using MPI will be useful for studying the pathology related to viscosity changes such as in vascular plaques and in determining cell viability of superparamagnetic iron oxide nanoparticle labeled cells. In this review article, an overview of MPI is provided with discussions mainly focusing on MPI tracers, applications of translational capabilities ranging from diagnostics to theranostics and finally outline a promising path towards clinical translation.


Subject(s)
Contrast Media , Magnetics/methods , Magnetite Nanoparticles , Neoplasms/diagnostic imaging , Angiography/methods , Biomedical Technology , Cell Tracking/methods , Humans , Magnetics/instrumentation , Perfusion Imaging/methods , Sensitivity and Specificity , Spin Labels , Theranostic Nanomedicine/instrumentation , Theranostic Nanomedicine/methods
14.
Curr Opin Chem Biol ; 45: 131-138, 2018 08.
Article in English | MEDLINE | ID: mdl-29754007

ABSTRACT

Magnetic particle imaging (MPI) is an emerging ionizing radiation-free biomedical tracer imaging technique that directly images the intense magnetization of superparamagnetic iron oxide nanoparticles (SPIOs). MPI offers ideal image contrast because MPI shows zero signal from background tissues. Moreover, there is zero attenuation of the signal with depth in tissue, allowing for imaging deep inside the body quantitatively at any location. Recent work has demonstrated the potential of MPI for robust, sensitive vascular imaging and cell tracking with high contrast and dose-limited sensitivity comparable to nuclear medicine. To foster future applications in MPI, this new biomedical imaging field is welcoming researchers with expertise in imaging physics, magnetic nanoparticle synthesis and functionalization, nanoscale physics, and small animal imaging applications.


Subject(s)
Blood Vessels/diagnostic imaging , Cell Tracking/instrumentation , Contrast Media/analysis , Diagnostic Techniques, Cardiovascular/instrumentation , Magnetics/instrumentation , Magnetite Nanoparticles/analysis , Animals , Cell Tracking/methods , Equipment Design , Humans , Magnetics/methods
15.
ACS Nano ; 12(4): 3699-3713, 2018 04 24.
Article in English | MEDLINE | ID: mdl-29570277

ABSTRACT

Image-guided treatment of cancer enables physicians to localize and treat tumors with great precision. Here, we present in vivo results showing that an emerging imaging modality, magnetic particle imaging (MPI), can be combined with magnetic hyperthermia into an image-guided theranostic platform. MPI is a noninvasive 3D tomographic imaging method with high sensitivity and contrast, zero ionizing radiation, and is linearly quantitative at any depth with no view limitations. The same superparamagnetic iron oxide nanoparticle (SPIONs) tracers imaged in MPI can also be excited to generate heat for magnetic hyperthermia. In this study, we demonstrate a theranostic platform, with quantitative MPI image guidance for treatment planning and use of the MPI gradients for spatial localization of magnetic hyperthermia to arbitrarily selected regions. This addresses a key challenge of conventional magnetic hyperthermia-SPIONs delivered systemically accumulate in off-target organs ( e.g., liver and spleen), and difficulty in localizing hyperthermia results in collateral heat damage to these organs. Using a MPI magnetic hyperthermia workflow, we demonstrate image-guided spatial localization of hyperthermia to the tumor while minimizing collateral damage to the nearby liver (1-2 cm distance). Localization of thermal damage and therapy was validated with luciferase activity and histological assessment. Apart from localizing thermal therapy, the technique presented here can also be extended to localize actuation of drug release and other biomechanical-based therapies. With high contrast and high sensitivity imaging combined with precise control and localization of the actuated therapy, MPI is a powerful platform for magnetic-based theranostics.


Subject(s)
Antineoplastic Agents/pharmacology , Heating , Hyperthermia, Induced , Magnetite Nanoparticles/chemistry , Mammary Neoplasms, Experimental/drug therapy , Optical Imaging , Animals , Antineoplastic Agents/administration & dosage , Antineoplastic Agents/chemistry , Apoptosis/drug effects , Cell Line, Tumor , Female , Humans , Magnetic Fields , Magnetite Nanoparticles/administration & dosage , Mammary Neoplasms, Experimental/pathology , Mice , Mice, Nude
16.
Article in English | MEDLINE | ID: mdl-29250434

ABSTRACT

Magnetic Particle Imaging (MPI) is a promising new tracer modality with zero attenuation in tissue, high contrast and sensitivity, and an excellent safety profile. However, the spatial resolution of MPI is currently around 1 mm in small animal scanners. Especially considering tradeoffs when scaling up MPI scanning systems to human size, this resolution needs to be improved for clinical applications such as angiography and brain perfusion. One method to improve spatial resolution is to increase the magnetic core size of the superparamagnetic nanoparticle tracers. The Langevin model of superparamagnetism predicts a cubic improvement of spatial resolution with magnetic core diameter. However, prior work has shown that the finite temporal response, or magnetic relaxation, of the tracer increases with magnetic core diameter and eventually leads to blurring in the MPI image. Here we perform the first wide ranging study of 5 core sizes between 18-32 nm with experimental quantification of the spatial resolution of each. Our results show that increasing magnetic relaxation with core size eventually opposes the expected Langevin behavior, causing spatial resolution to stop improving after 25 nm. Different MPI excitation strategies were experimentally investigated to mitigate the effect of magnetic relaxation. The results show that magnetic relaxation could not be fully mitigated for the larger core sizes and the cubic resolution improvement predicted by the Langevin was not achieved. This suggests that magnetic relaxation is a significant and unsolved barrier to achieving the high spatial resolutions predicted by the Langevin model for large core size SPIOs.

17.
ACS Nano ; 11(12): 12067-12076, 2017 12 26.
Article in English | MEDLINE | ID: mdl-29165995

ABSTRACT

Gastrointestinal (GI) bleeding causes more than 300 000 hospitalizations per year in the United States. Imaging plays a crucial role in accurately locating the source of the bleed for timely intervention. Magnetic particle imaging (MPI) is an emerging clinically translatable imaging modality that images superparamagnetic iron-oxide (SPIO) tracers with extraordinary contrast and sensitivity. This linearly quantitative modality has zero background tissue signal and zero signal depth attenuation. MPI is also safe: there is zero ionizing radiation exposure to the patient and clinically approved tracers can be used with MPI. In this study, we demonstrate the use of MPI along with long-circulating, PEG-stabilized SPIOs for rapid in vivo detection and quantification of GI bleed. A mouse model genetically predisposed to GI polyp development (ApcMin/+) was used for this study, and heparin was used as an anticoagulant to induce acute GI bleeding. We then injected MPI-tailored, long-circulating SPIOs through the tail vein, and tracked the tracer biodistribution over time using our custom-built high resolution field-free line (FFL) MPI scanner. Dynamic MPI projection images captured tracer accumulation in the lower GI tract with excellent contrast. Quantitative analysis of the MPI images show that the mice experienced GI bleed rates between 1 and 5 µL/min. Although there are currently no human scale MPI systems, and MPI-tailored SPIOs need to undergo further development and evaluation, clinical translation of the technique is achievable. The robust contrast, sensitivity, safety, ability to image anywhere in the body, along with long-circulating SPIOs lends MPI outstanding promise as a clinical diagnostic tool for GI bleeding.


Subject(s)
Disease Models, Animal , Ferric Compounds/chemistry , Gastrointestinal Hemorrhage/diagnostic imaging , Magnetite Nanoparticles/chemistry , Molecular Imaging , Animals , Male , Mice , Mice, Inbred C57BL
18.
Mol Imaging Biol ; 19(3): 385-390, 2017 06.
Article in English | MEDLINE | ID: mdl-28396973

ABSTRACT

Magnetic particle imaging (MPI) is a new molecular imaging technique that directly images superparamagnetic tracers with high image contrast and sensitivity approaching nuclear medicine techniques-but without ionizing radiation. Since its inception, the MPI research field has quickly progressed in imaging theory, hardware, tracer design, and biomedical applications. Here, we describe the history and field of MPI, outline pressing challenges to MPI technology and clinical translation, highlight unique applications in MPI, and describe the role of the WMIS MPI Interest Group in collaboratively advancing MPI as a molecular imaging technique. We invite interested investigators to join the MPI Interest Group and contribute new insights and innovations to the MPI field.


Subject(s)
Dextrans/chemistry , Magnetite Nanoparticles/chemistry , Molecular Imaging/methods , Animals , Humans
19.
Phys Med Biol ; 62(9): 3483-3500, 2017 05 07.
Article in English | MEDLINE | ID: mdl-28032621

ABSTRACT

Magnetic particle imaging (MPI) is a rapidly developing molecular and cellular imaging modality. Magnetic fluid hyperthermia (MFH) is a promising therapeutic approach where magnetic nanoparticles are used as a conduit for targeted energy deposition, such as in hyperthermia induction and drug delivery. The physics germane to and exploited by MPI and MFH are similar, and the same particles can be used effectively for both. Consequently, the method of signal localization through the use of gradient fields in MPI can also be used to spatially localize MFH, allowing for spatially selective heating deep in the body and generally providing greater control and flexibility in MFH. Furthermore, MPI and MFH may be integrated together in a single device for simultaneous MPI-MFH and seamless switching between imaging and therapeutic modes. Here we show simulation and experimental work quantifying the extent of spatial localization of MFH using MPI systems: we report the first combined MPI-MFH system and demonstrate on-demand selective heating of nanoparticle samples separated by only 3 mm (up to 0.4 °C s-1 heating rates and 150 W g-1 SAR deposition). We also show experimental data for MPI performed at a typical MFH frequency and show preliminary simultaneous MPI-MFH experimental data.


Subject(s)
Diagnostic Imaging/methods , Magnetite Nanoparticles , Theranostic Nanomedicine/methods , Diagnostic Imaging/instrumentation , Hot Temperature , Magnetic Fields , Theranostic Nanomedicine/instrumentation
20.
Sci Rep ; 6: 34180, 2016 Sep 30.
Article in English | MEDLINE | ID: mdl-27686629

ABSTRACT

Magnetic Particle Imaging (MPI) is a promising new tracer modality with zero attenuation deep in tissue, high contrast and sensitivity, and an excellent safety profile. However, the spatial resolution of MPI is limited to around 1 mm currently and urgently needs to be improved for clinical applications such as angiography and brain perfusion. Although MPI resolution is highly dependent on tracer characteristics and the drive waveforms, optimization is limited to a small subset of possible excitation strategies by current MPI hardware that only does sinusoidal drive waveforms at very few frequencies. To enable a more comprehensive and rapid optimization of drive waveforms for multiple metrics like resolution and signal strength simultaneously, we demonstrate the first untuned MPI spectrometer/relaxometer with unprecedented 400 kHz excitation bandwidth and capable of high-throughput acquisition of harmonic spectra (100 different drive-field frequencies in only 500 ms). It is also capable of arbitrary drive-field waveforms which have not been experimentally evaluated in MPI to date. Its high-throughput capability, frequency-agility and tabletop size makes this Arbitrary Waveform Relaxometer/Spectrometer (AWR) a convenient yet powerfully flexible tool for nanoparticle experts seeking to characterize magnetic particles and optimize MPI drive waveforms for in vitro biosensing and in vivo imaging with MPI.

SELECTION OF CITATIONS
SEARCH DETAIL