Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Radiol Med ; 114(6): 907-14, 2009 Sep.
Article in English, Italian | MEDLINE | ID: mdl-19551342

ABSTRACT

PURPOSE: The purpose of this study was to assess the interval cancer (IC) proportional incidence and review IC cases observed in an Italian mammography screening programme during 2000-2006. MATERIALS AND METHODS: ICs were identified through linkage of a screening database with the local cancer registry and hospital discharge records to calculate proportional (observed/expected) incidence. Negatively reported mammograms preceding ICs underwent blind review (randomly mixed with negative controls in a 2:1 ratio) by three expert radiologists and classified according to European guidelines criteria (OC=occult, MS=minimal sign, SE=screening error) according to majority report. Proportional IC incidence and rate of reviewed IC classified as SE were compared with European guideline standards. RESULTS: Proportional IC incidence was 10.8% in the first and 40.0% in the second year of the interval (European standard=30% or 50%, respectively). Sensitivity estimate for the 2-year interval was 74.6%. ICs were reviewed as SE, MS or OC in 15.0%, 14.0% or 71.0% of cases, respectively. Corresponding review results for negative controls were 7.0%, 25.0% or 68.0%, respectively. Positive predictive value for IC was 51.7% for SE and 21.8% for MS reporting category, respectively (p=0.008). European standard (<20% reviewed as SE) was reached. CONCLUSIONS: The study shows that the sensitivity of the mammography programme was good, complying with European guideline recommendations. Assessment of IC-based early indicators of screening efficacy is feasible in a current screening programme and should become a routine procedure.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Mammography/standards , Aged , Case-Control Studies , Diagnostic Errors/statistics & numerical data , Female , Humans , Incidence , Italy/epidemiology , Mass Screening/standards , Middle Aged , Practice Guidelines as Topic , Program Evaluation , Quality Control , Quality of Health Care , Registries , Sensitivity and Specificity
2.
Radiol Med ; 114(5): 792-801, 2009 Aug.
Article in English, Italian | MEDLINE | ID: mdl-19551345

ABSTRACT

PURPOSE: This study was undertaken to establish the reliability of automated volumetric liver scans in detecting focal liver lesions by evaluating the degree of agreement between conventional and volume ultrasound (US) examinations. MATERIALS AND METHODS: Over a period of 3 months, we prospectively studied 100 consecutive patients (36 men and 64 women; age range 15-87 years; mean age 63 years) referred to our institute for US imaging of the liver. Volumetric acquisition of the liver was achieved with a 3D transducer (2.0-5.0 MHz) and a Logiq 9 US scanner. All patients underwent both 2- and 3D US studies performed by two expert radiologists. Volumetric acquisitions were subsequently reviewed by the second radiologist, who was blinded to the first radiologist's report. Three categories were established: 1=presence of focal liver lesions; 2=doubtful finding; 3=absence of focal liver lesions. Concordance between volume US and conventional US was calculated by using the k statistic. RESULTS: Out of 100 patients examined, 39 were found to be affected by focal liver lesions. All volume US examinations were technically adequate, allowing exploration of all hepatic sectors, except for five cases that were marred by major respiratory motion artefacts. Conventional and volume US identified the same number of focal liver lesions, with the exception of four cases of doubtful findings at volume US. Concordance between automated volume US and conventional US of the liver was high (k=0.92). CONCLUSIONS: The identification of focal liver lesions on automated volume US is possible, and the examination shows a high level of concordance with conventional US.


Subject(s)
Liver Diseases/diagnostic imaging , Ultrasonography/methods , Adolescent , Adult , Aged , Aged, 80 and over , Diagnosis, Differential , Female , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Liver Diseases/pathology , Male , Middle Aged , Prospective Studies , Reproducibility of Results
3.
Radiol Med ; 113(1): 76-86, 2008 Feb.
Article in English, Italian | MEDLINE | ID: mdl-18338129

ABSTRACT

PURPOSE: This study was done to compare the perfusion patterns of intrahepatic peripheral cholangiocarcinoma (IPCC) on contrast-enhanced ultrasound (CEUS) and dynamic computed tomography (CT). MATERIALS AND METHODS: We retrospectively reviewed 23 histologically proven cases of IPCC. All lesions were studied by CEUS with sulfur hexafluoride-filled microbubbles coated with a phospholipid capsule, and by dynamic CT. Contrast-enhancement patterns were evaluated in the arterial phase (CEUS 10-20 s after the injection; CT 25-30 s after the injection) and in the delayed phase (CEUS 120 s after the injection; CT>2-3 min after the injection). RESULTS: Lesions were single in 18/23 cases (78%), single with nearby satellite lesions in 1/23 (4%) cases and multifocal with distant secondary lesions in 4/23 (17%) cases. Lesion diameter was 2-5 cm in 7/23 cases (30%), 5-7 cm in 13/23 cases (57%) and >7 cm in 3/23 (13%) cases. On CEUS, lesions were hypervascular in 16/23 cases (70%). On delayed-phase CEUS, 22/23 lesions (96%) were markedly hypoechoic. CT showed that the lesions were hypovascular in the arterial phase in 15/23 cases (66%) and hypervascular in 7/23 (30%) cases; one lesion (1/23; 4%) was isovascular. On delayed-phase CT, lesions were hyperdense in 17/23 cases (74%), hypodense in 5/23 (22%) cases and isodense in 1/23 (43%) cases. CONCLUSIONS: Enhancement discrepancy between delayed-phase CEUS (hypoechogenicity) and CT (hyperdensity) is common semiological findings in the study of IPCC.


Subject(s)
Bile Duct Neoplasms/diagnostic imaging , Bile Ducts, Intrahepatic/diagnostic imaging , Cholangiocarcinoma/diagnostic imaging , Contrast Media , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Female , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Iohexol/analogs & derivatives , Liver/diagnostic imaging , Male , Microbubbles , Middle Aged , Phospholipids , Radiographic Image Enhancement/methods , Retrospective Studies , Sulfur Hexafluoride , Time Factors , Ultrasonography
4.
J Affect Disord ; 110(1-2): 106-14, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18291534

ABSTRACT

OBJECTIVES: Previous imaging reports showed over-activation of fronto-limbic structures in bipolar patients, particularly in response to emotional stimuli. In this study, for the first time, we used perfusion weighted imaging (PWI) to analyze lobar cerebral blood volume (CBV) in bipolar disorder to further explore the vascular component to its pathophysiology. METHODS: Fourteen patients with DSM-IV bipolar disorder (mean age+/-SD=49.00+/-12.30 years; 6 males, 8 females) and 29 normal controls (mean age+/-SD=45.07+/-10.30 years; 13 males, 16 females) were studied. PWI images were obtained following intravenous injection of paramagnetic contrast agent (Gadolinium-DTPA), with a 1.5 T Siemens magnet using an echo-planar sequence. The contrast of enhancement (CE), was calculated pixel by pixel as the ratio of the maximum signal intensity drop during the passage of contrast agent (Sm) by the baseline pre-bolus signal intensity (So) (CE=Sm/So*100) for frontal, temporal, parietal, and occipital lobes, bilaterally, on two axial images. Higher CE values correspond to lower CBV and viceversa. RESULTS: Bipolar patients had significantly lower CE values in left frontal and temporal lobes (p=0.01 and p=0.03, respectively) and significantly inverse laterality index for frontal lobe (p=0.017) compared to normal controls. No significant correlations between CE measure and age or clinical variables were found (p>0.05). CONCLUSION: This study found increased left frontal and temporal CBV in bipolar disorder. Fronto-temporal hyper-perfusion may sustain over-activation of these structures during emotion modulation, which have been observed in patients with bipolar illness.


Subject(s)
Bipolar Disorder/physiopathology , Echo-Planar Imaging/statistics & numerical data , Frontal Lobe/blood supply , Temporal Lobe/blood supply , Bipolar Disorder/diagnosis , Bipolar Disorder/diagnostic imaging , Contrast Media/administration & dosage , Control Groups , Echo-Planar Imaging/methods , Female , Frontal Lobe/diagnostic imaging , Functional Laterality/physiology , Gadolinium DTPA/administration & dosage , Humans , Image Enhancement , Image Processing, Computer-Assisted , Male , Middle Aged , Occipital Lobe/blood supply , Occipital Lobe/diagnostic imaging , Parietal Lobe/blood supply , Parietal Lobe/diagnostic imaging , Psychiatric Status Rating Scales/statistics & numerical data , Radionuclide Imaging , Regional Blood Flow/physiology , Temporal Lobe/diagnostic imaging
5.
Abdom Imaging ; 32(2): 200-6, 2007.
Article in English | MEDLINE | ID: mdl-16858661

ABSTRACT

The usefulness of intraoperative ultrasonography (IOUS) has been documented in the Literature since the Eighties and, although its main applications are in hepatobiliary and pancreatic surgery, it has been used also in neurosurgery, cardiovascular and endocrine surgery. The continuous technical developments have led to an increase in the diagnostic accuracy of IOUS from the Eighties to now. The use of IOUS has increased in time together with the technical innovations until, mainly in the midnineties, its value was recognized by many surgeons. This results have been obtained with scanners that allow to depict fine anatomical details and detect small lesions in real time with extremely high spatial resolution. IOUS is able to shows fine details, such as primary or secondary lesions not detectable with other preoperative imaging modalities or tumor extension and its relationship with vessels. Assessment of resectability by IOUS may determine important changes in therapeutic planning. The role of IOUS, however, has recently been down-sized, especially in those centers where preoperative imaging is advanced. This article will review the clinical role of pancreatic IOUS in the different pancreatic pathologies.


Subject(s)
Pancreas/diagnostic imaging , Pancreatic Diseases/diagnostic imaging , Pancreatic Diseases/surgery , Humans , Intraoperative Period , Liver , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/surgery , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL