1.
Eye (Lond) ; 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39095469

ABSTRACT

BACKGROUND: High myopia is a major cause of visual impairment, and genetic factors play crucial roles in the pathogenesis. We performed this study to identify candidate genes for the development of high myopia in a four-generation Chinese family with myopia. METHODS: All family members with myopia and 100 healthy participants were included in this study. Data were obtained on demographics, disease history, and ocular examination results. We performed whole exome sequencing of the genomic DNA and Sanger sequencing to verify the variants. Functional analyses of the variant were performed using software programmes. RESULTS: Nine of thirteen family members were found to have high myopia, amongst which two members were also diagnosed keratoconus. A missense variant in the keratin 12 gene (KRT12, p.Val410Gly) was detected in all high myopia cases but not in other family members without high myopia or the controls. The variant was predicted to be benign by online software programmes. However, modelling of the three-dimensional structure of the protein clearly revealed conformational changes caused by the mutation. CONCLUSIONS: A missense mutation in the KRT12 gene was identified in this Chinese family, which may be associated with the pathogenesis of high myopia.

2.
BMC Ophthalmol ; 24(1): 289, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014346

ABSTRACT

BACKGROUND: This study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. METHODS: Eighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants' axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots. RESULTS: With the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and - 9.989 to 13.486 µm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively. CONCLUSIONS: In young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.


Subject(s)
Axial Length, Eye , Biometry , Myopia , Humans , Male , Biometry/methods , Biometry/instrumentation , Axial Length, Eye/pathology , Myopia/physiopathology , Myopia/diagnosis , Female , Adult , Young Adult , Fourier Analysis , Tomography, Optical Coherence/methods , Anterior Eye Segment/diagnostic imaging , Anterior Eye Segment/pathology , Cornea/pathology , Cornea/diagnostic imaging , Refraction, Ocular/physiology
3.
Article in English | MEDLINE | ID: mdl-39025652

ABSTRACT

PURPOSE: To compare the long-term refractive outcomes and visual quality after KLEx and EVO-ICL implantation for high myopia. SETTING: Eye & ENT Hospital of Fudan University, Shanghai, China. DESIGN: A retrospective study. METHODS: This study included 31 KLEx-treated patients (31 eyes, spherical equivalent: -7.62D ± 1.22) and 32 ICL-treated patients (32 eyes, spherical equivalent: -8.22D ± 1.18). Refractive outcomes and objective visual quality were examined. Subjective visual quality was evaluated by a customized questionnaire. Patients' satisfaction was graded. RESULTS: Five-year postoperatively, the efficacy (KLEx: 0.96 ± 0.20; ICL: 1.03 ± 0.20; P = 0.164) and safety indices (KLEx:1.12 ± 0.20; ICL: 1.21 ± 0.19; P = 0.067) were comparable. Statistically higher proportions of ICL-treated eyes achieved a postoperative UDVA of 20/20 or better (P = 0.035). Refractive predictability was similar between the two groups (P = 0.947), whereas more KLEx-treated eyes had myopic refractive errors (P < 0.001). Total coma was significantly higher after KLEx (P = 0.020), and greater total trefoil was observed after ICL implantation (P = 0.006). Haloes were the primary visual disturbance in both groups (KLEx: 64.5%; ICL: 93.8%). The incidences of haloes (P < 0.001), glare (P = 0.004), and starbursts (P = 0.043) were notably higher after ICL implantation. The patient's satisfaction scores were similar (KLEx: 9.10 ± 1.27; ICL: 9.10 ± 1.27; P = 0.894). CONCLUSIONS: For high myopia, EVO-ICL yielded better long-term refractive outcomes than KLEx. Haloes were the chief complaint in both groups, with a significantly higher incidence after ICL implantation.

4.
Eye (Lond) ; 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38997503

ABSTRACT

BACKGROUND: To assess the changes in the posterior corneal surface following small incision lenticule extraction (SMILE) with different optical zones. METHODS: In this retrospective study, 106 eyes of 106 patients who underwent SMILE were recruited 3 years after the procedure. Eyes were divided into two groups according to the size of the surgical optical zone: group A (52 eyes, ≤6.2 mm) and group B (54 eyes, ≥6.5 mm). Posterior central elevation (PCE) and 12 other points at 45°, 135°, 225° and 315° with distances of 1 mm, 2 mm and 3 mm from the centre were recorded from Pentacam. RESULTS: No iatrogenic keratectasia was identified, and eyes in the two groups showed comparable visual results. The overall trend in posterior corneal elevation changes was consistent for both groups. PCE decreased significantly from 1.33 ± 2.32 to 0.75 ± 2.41 in group A (P = 0.024) and from 0.87 ± 2.61 to 0.06 ± 2.74 in group B (P = 0.003). All points in the central 2 mm region in both groups were reduced postoperatively. In the 4 mm and 6 mm corneal annulus, almost all points at 225°and 315° showed backward displacement, with the most prominent change occurring at 315° in the 6 mm annulus (P < 0.001), indicating no forward protrusion in the inferior area. CONCLUSIONS: No forward protrusion in the posterior corneal surface was observed 3 years after SMILE with different optical zones. Comprehensive preoperative measurements are essential for ensuring corneal stability and avoiding iatrogenic keratectasia.

5.
Nat Commun ; 15(1): 5508, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38951161

ABSTRACT

Keratoconus, a disorder characterized by corneal thinning and weakening, results in vision loss. Corneal crosslinking (CXL) can halt the progression of keratoconus. The development of accelerated corneal crosslinking (A-CXL) protocols to shorten the treatment time has been hampered by the rapid depletion of stromal oxygen when higher UVA intensities are used, resulting in a reduced cross-linking effect. It is therefore imperative to develop better methods to increase the oxygen concentration within the corneal stroma during the A-CXL process. Photocatalytic oxygen-generating nanomaterials are promising candidates to solve the hypoxia problem during A-CXL. Biocompatible graphitic carbon nitride (g-C3N4) quantum dots (QDs)-based oxygen self-sufficient platforms including g-C3N4 QDs and riboflavin/g-C3N4 QDs composites (RF@g-C3N4 QDs) have been developed in this study. Both display excellent photocatalytic oxygen generation ability, high reactive oxygen species (ROS) yield, and excellent biosafety. More importantly, the A-CXL effect of the g-C3N4 QDs or RF@g-C3N4 QDs composite on male New Zealand white rabbits is better than that of the riboflavin 5'-phosphate sodium (RF) A-CXL protocol under the same conditions, indicating excellent strengthening of the cornea after A-CXL treatments. These lead us to suggest the potential application of g-C3N4 QDs in A-CXL for corneal ectasias and other corneal diseases.


Subject(s)
Cross-Linking Reagents , Graphite , Oxygen , Quantum Dots , Riboflavin , Quantum Dots/chemistry , Animals , Graphite/chemistry , Oxygen/metabolism , Riboflavin/pharmacology , Rabbits , Male , Cross-Linking Reagents/chemistry , Nitrogen Compounds/chemistry , Reactive Oxygen Species/metabolism , Keratoconus/drug therapy , Keratoconus/metabolism , Ultraviolet Rays , Cornea/drug effects , Cornea/metabolism , Cornea/pathology , Humans , Photosensitizing Agents/pharmacology , Corneal Stroma/metabolism , Corneal Stroma/drug effects
6.
Article in English | MEDLINE | ID: mdl-38980219

ABSTRACT

PURPOSE: Autostereoscopic displays have become increasingly common, but their impact on ocular dimensions remains unknown. We sought to identify changes in the crystalline lens dimensions induced by autostereoscopic three-dimensional (3D) viewing. METHODS: Forty young adults (age: 22.6 ± 2.0 years, male/female: 15/25) were consecutively enrolled and randomly divided into two groups (3D and two-dimensional [2D] viewing groups) to watch a 30-min movie clip displayed in 3D or 2D mode on a tablet computer. The lens thickness (LT), diameter, curvature, decentration and tilt were measured with anterior segment optical coherence tomography under both non-accommodating (static) and accommodating conditions. RESULTS: In the static condition, the LT decreased by 0.03 ± 0.03 mm (p < 0.001) and the anterior radius of curvature (ARC) increased by 0.49 ± 0.59 mm (p = 0.001) post-3D viewing. In contrast, following 2D viewing, the ARC decreased by 0.23 ± 0.25 mm (p = 0.001). Additionally, the increase in the steep ARC post-3D viewing was greater in high-myopic eyes than low to moderate myopic eyes (p = 0.04). When comparing the accommodative with the static (non-accommodative) condition, for 3D viewing the lens decentration decreased (-0.03 ± 0.05 mm, p = 0.02); while for 2D viewing, the posterior curvature radius (-0.14 ± 0.20 mm, p = 0.006) and diameter (-0.13 ± 0.20 mm, p = 0.01) decreased. CONCLUSIONS: Viewing with the autostereoscopic 3D tablet could temporally decrease the thickness and curvature of the lens under non-accommodating conditions. However, its long-term effect requires further exploration.

7.
Cornea ; 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38967494

ABSTRACT

PURPOSE: To evaluate changes of hydroxyproline concentration and its influencing factors of small incision lenticule extraction (SMILE)-derived corneal stromal lenticules with different preservation methods. METHODS: A total of 390 corneal stromal lenticules of 195 patients were derived from SMILE surgeries. Thirty of the lenticules were classified as the fresh (control) group, and the rest were randomly and evenly divided and stored in anhydrous glycerol, silicone oil, Optisol, and cryopreservation for 1 day, 1 week, or 1 month. A hydroxyproline assay kit (ab222941, Abcam) was used to measure the hydroxyproline concentration in each preservation method. Concentrations of MMP-2, TIMP-2, TNFα, TGFß2, and reactive oxygen species were also evaluated. RESULTS: In the anhydrous glycerol group, the concentration of hydroxyproline decreased within 1 week (fresh: 1 dΔ = 0.229, P < 0.001*; 1 d - 1 wΔ = 0.055, P < 0.001*) while that in the silicone oil group remained stable in 1 week (1 d - 1 wΔ = -0.005, P = 0.929) and decreased significantly in 1 m (1 m - 1 wΔ = -0.041, P = 0.003*). The sequence of hydroxyproline concentration in the Optisol group was 1 m > 1 day > 1 week. Hydroxyproline concentration in the cryopreservation group decreased within 1 m. Hydroxyproline concentration was highest in the Optisol group and lowest in the anhydrous glycerol group under the same preservation time. Hydroxyproline concentration was negatively correlated with MMP-2 (r = -0.16, P = 0.421) and TIMP-2 (r = -0.56, P = 0.002*) while MMP-2 and TNFα (r = 0.17, P = 0.242), TIMP-2 and TGFß2 (r = 0.21, P = 0.207), and TNFα and reactive oxygen species (r = 0.52, P = 0.007*) were positively correlated. CONCLUSIONS: More collagen was retained in SMILE lenticules preserved in Optisol under the same preservation time. The mechanism of the changes of collagen in preserved SMILE-derived lenticules and oxidative stress requires additional investigation.

8.
J Agric Food Chem ; 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-39084686

ABSTRACT

Intestinal stem cells (ISCs) are necessary to maintain intestinal renewal. Here, we found that the highland barley ß-glucan (HBG) alleviated pathological symptoms and promoted the proliferation of intestinal stem cells in colitis mice. Notably, metabolomics studies showed that docosahexaenoic acid (DHA) was significantly increased by the HBG treatment. DHA is a ligand for peroxisome proliferator-activated receptor α (PPARα), which can promote ISC proliferation. Expectedly, HBG facilitated the expression of intestinal PPARα and the proliferation of ISCs in colitis mice. Further experiments verified that DHA significantly facilitated the expression of PPARα and the proliferation of ISCs in intestinal organoids. Intriguingly, the effect of DHA on ISC proliferation was reversed by the PPARα inhibitor. Together, our data indicate that HBG might accelerate PPARα-mediated ISC proliferation through DHA. This provides new insights into the effective application of polysaccharides in maintaining intestinal homeostasis.

9.
Nat Commun ; 15(1): 6395, 2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39080269

ABSTRACT

Glaucoma affects approximately 80 million individuals worldwide, a condition for which current treatment options are inadequate. The primary risk factor for glaucoma is elevated intraocular pressure. Intraocular pressure is determined by the balance between the secretion and outflow of aqueous humor. Here we show that using the RNA interference tool CasRx based on shH10 adenovirus-associated virus can reduce the expression of the aqueous humor circulation related genes Rock1 and Rock2, as well as aquaporin 1 and ß2 adrenergic receptor in female mice. This significantly reduced intraocular pressure in female mice and provided protection to the retina ganglion cells, ultimately delaying disease progression. In addition, we elucidated the mechanisms by which the knockdown of Rock1 and Rock2, or aquaporin 1 and ß2 adrenergic receptor in female mice, reduces the intraocular pressure and secures the retina ganglion cells by single-cell sequencing.


Subject(s)
Aquaporin 1 , CRISPR-Cas Systems , Glaucoma , Intraocular Pressure , Retinal Ganglion Cells , rho-Associated Kinases , Animals , Retinal Ganglion Cells/metabolism , Retinal Ganglion Cells/pathology , rho-Associated Kinases/metabolism , rho-Associated Kinases/genetics , Female , Aquaporin 1/metabolism , Aquaporin 1/genetics , Mice , Glaucoma/genetics , Glaucoma/metabolism , Aqueous Humor/metabolism , Mice, Inbred C57BL , Disease Models, Animal , RNA Interference , Humans
10.
Adv Sci (Weinh) ; : e2403399, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-39031809

ABSTRACT

Funduscopic diseases, including diabetic retinopathy (DR) and age-related macular degeneration (AMD), significantly impact global visual health, leading to impaired vision and irreversible blindness. Delivering drugs to the posterior segment of the eye remains a challenge due to the presence of multiple physiological and anatomical barriers. Conventional drug delivery methods often prove ineffective and may cause side effects. Nanomaterials, characterized by their small size, large surface area, tunable properties, and biocompatibility, enhance the permeability, stability, and targeting of drugs. Ocular nanomaterials encompass a wide range, including lipid nanomaterials, polymer nanomaterials, metal nanomaterials, carbon nanomaterials, quantum dot nanomaterials, and so on. These innovative materials, often combined with hydrogels and exosomes, are engineered to address multiple mechanisms, including macrophage polarization, reactive oxygen species (ROS) scavenging, and anti-vascular endothelial growth factor (VEGF). Compared to conventional modalities, nanomedicines achieve regulated and sustained delivery, reduced administration frequency, prolonged drug action, and minimized side effects. This study delves into the obstacles encountered in drug delivery to the posterior segment and highlights the progress facilitated by nanomedicine. Prospectively, these findings pave the way for next-generation ocular drug delivery systems and deeper clinical research, aiming to refine treatments, alleviate the burden on patients, and ultimately improve visual health globally.

11.
J Refract Surg ; 40(6): e381-e391, 2024 May.
Article in English | MEDLINE | ID: mdl-38848059

ABSTRACT

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years. METHODS: This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit. RESULTS: At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups. CONCLUSIONS: Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].


Subject(s)
Lens Implantation, Intraocular , Myopia, Degenerative , Phakic Intraocular Lenses , Refraction, Ocular , Visual Acuity , Humans , Visual Acuity/physiology , Refraction, Ocular/physiology , Male , Female , Middle Aged , Adult , Follow-Up Studies , Myopia, Degenerative/physiopathology , Myopia, Degenerative/surgery , Retrospective Studies , Corneal Wavefront Aberration/physiopathology , Rotation
12.
Curr Eye Res ; : 1-7, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38913085

ABSTRACT

PURPOSE: This study aimed to compare early changes in classified higher-order aberrations (HOAs) pre- and postsurgery in patients who received nontoric versus toric implantable collamer lenses (ICL; ICL Model V4c; STAAR Surgical, Monrovia, CA, USA). METHODS: This prospective study included 124 eyes of 64 patients: 49 eyes were treated using a nontoric implantable collamer lens (ICL), and 75 eyes were treated using a toric implantable collamer lenses (TICL). Refractive parameters and ocular aberrations were examined before and 1 month after surgery. RESULTS: At one month, the safety indices were 1.24 ± 0.17 in the ICL group and 1.20 ± 0.25 in the TICL group (p = 0.39). The efficacy indices were 1.07 ± 0.17 in the ICL group and 1.15 ± 0.26 in the TICL group (p = 0.02). The root mean square (RMS) values of whole-eye total HOAs, trefoil, corneal total HOAs, spherical aberration, and intraocular spherical aberration significantly increased postoperatively in both groups. The RMS of intraocular total HOAs in the TICL group significantly increased 1 month postoperatively. No statistically significant differences were observed in HOA changes between the ICL and TICL groups. CONCLUSIONS: The dominant increases in short-term aberrations after ICL and TICL V4c implantation were in corneal trefoil and intraocular spherical aberrations, which were related to the corneal incision and implanted lens. The HOA changes post-surgery were not statistically different between the two lens types.

13.
Article in English | MEDLINE | ID: mdl-38916723

ABSTRACT

BACKGROUND: The purpose of this study was to identify the possible association between mental status and the risk of self-reported asthenopia among college students in China. METHODS: Ten thousand students were randomly assessed in the study using a self-reported asthenopia questionnaire. Their demographic characteristics and mental status were recorded. Univariate analysis was performed to preliminarily select potential risk and protective factors. Then, multivariate logistic regression was used to estimate odds ratios for the selected risk factors of interest. RESULTS: Among the 8370 students who completed the survey, the prevalence of asthenopia was 61.0%. Multivariate analysis revealed a significant relationship between asthenopia and depressive symptoms (OR 1.511 95% CI: 1.350-1.691), obsessive-compulsive symptoms (OR 1.477, 95% CI: 1.338-1.632), gender and study load. The place college students spent their off-hours (OR 0.841, 95% CI: 0.784-0.902) was found to be the strongest factor for decreasing the occurrence of asthenopia complaints. CONCLUSION: Asthenopia appears common in Chinese college students. In addition to depressive symptoms, we should pay attention to obsessive-compulsive symptoms when considering means of preventing asthenopia. Harmonious social relationships, outdoor off-hour activities and exercising more than three times per week are crucial to relieving visual fatigue. Further study is still needed in this area.

14.
Adv Mater ; : e2403935, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38889294

ABSTRACT

Tissue-specific delivery of oligonucleotide therapeutics beyond the liver remains a key challenge in nucleic acid drug development. To address this issue, exploiting exosomes as a novel carrier has emerged as a promising approach for efficient nucleic acid drug delivery. However, current exosome-based delivery systems still face multiple hurdles in their clinical applications. Herein, this work presents a strategy for constructing a hybrid exosome vehicle (HEV) through a DNA zipper-mediated membrane fusion approach for tissue-specific siRNA delivery. As a proof-of-concept, this work successfully fuses a liposome encapsulating anti-NFKBIZ siRNAs with corneal epithelium cell (CEC)-derived exosomes to form a HEV construct for the treatment of dry eye disease (DED). With homing characteristics inherited from exosomes, the siRNA-bearing HEV can target its parent cells and efficiently deliver the siRNA payloads to the cornea. Subsequently, the NFKBIZ gene silencing significantly reduces pro-inflammatory cytokine secretions from the ocular surface, reshapes its inflammatory microenvironment, and ultimately achieves an excellent therapeutic outcome in a DED mouse model. As a versatile platform, this hybrid exosome with targeting capability and designed therapeutic siRNAs may hold great potential in various disease treatments.

15.
Exp Eye Res ; 244: 109930, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38750782

ABSTRACT

Corneal neovascularization (CoNV) is a vision-threatening ocular disease commonly secondary to infectious, inflammatory, and traumatic etiologies. Slit lamp photography, in vivo confocal microscopy, angiography, and optical coherence tomography angiography (OCTA) are the primary diagnostic tools utilized in clinical practice to evaluate the vasculature of the ocular surface. However, there is currently a dearth of comprehensive literature that reviews the advancements in imaging technology for CoNV administration. Initially designed for retinal vascular imaging, OCTA has now been expanded to the anterior segment and has shown promising potential for imaging the conjunctiva, cornea, and iris. This expansion allows for the quantitative monitoring of the structural and functional changes associated with CoNV. In this review, we emphasize the impact of algorithm optimization in anterior segment-optical coherence tomography angiography (AS-OCTA) on the diagnostic efficacy of CoNV. Through the analysis of existing literature, animal model assessments are further reported to investigate its pathological mechanism and exhibit remarkable therapeutic interventions. In conclusion, AS-OCTA holds broad prospects and extensive potential for clinical diagnostics and research applications in CoNV.


Subject(s)
Corneal Neovascularization , Fluorescein Angiography , Tomography, Optical Coherence , Corneal Neovascularization/diagnosis , Humans , Tomography, Optical Coherence/methods , Animals , Fluorescein Angiography/methods , Cornea/blood supply , Cornea/pathology , Cornea/diagnostic imaging , Microscopy, Confocal
16.
Asia Pac J Ophthalmol (Phila) ; 13(3): 100075, 2024.
Article in English | MEDLINE | ID: mdl-38795866

ABSTRACT

PURPOSE: To compare the visual outcomes and risks of suboptimal vault-related complications between immediate sequential bilateral ICL surgery (ISBICLS) and delayed sequential bilateral ICL surgery (DSBICLS). DESIGN: A retrospective cohort study. METHODS: Patients who underwent bilateral ICL implantation between November 2014 and December 2021 at the Eye and ENT Hospital of Fudan University (Shanghai, China) were included and divided into two groups: (1) ISBICLS: both eye surgeries performed on the same day, and (2) DSBICLS: second eye surgery performed < 7 days following the first one. Propensity score matching (PSM) was performed to compare the visual outcomes. Multivariable logistic regression models were used to estimate the odds ratios (ORs) of the suboptimal vaults. RESULTS: Finally, 10,985 eyes were included. After PSM, 204 first surgery eyes and 162 s surgery eyes with complete postoperative data were matched. The safety and efficacy indices did not statistically differ between groups (all > 1.00), except that ISBICLS first surgery eyes achieved better efficacy index than DSBICLS group (1.03 ± 0.26 vs. 1.08 ± 0.23, P = 0.034). Excessive vault was observed in eight (4.06 %) ISBICLS first eyes, one (0.50 %) DSBICLS first eye, and none in the second surgery eye in either group. An insufficient vault was observed in one second eye and one DSBICLS second eye. We found no evidence of differences in the rate of excessive vault (OR = 0.831, 95 % CI: 0.426-1.622, P = 0.588) or insufficient vault (OR = 0.609, 95 % CI:0.062-5.850, P = 0.668). CONCLUSION: ISBICLS provided safety, efficacy, and refraction predictability comparable to DSBICLS without increasing the risk of suboptimal vault-related complications.


Subject(s)
Lens Implantation, Intraocular , Visual Acuity , Humans , Retrospective Studies , Male , Female , Adult , Lens Implantation, Intraocular/methods , Myopia/surgery , Myopia/physiopathology , Middle Aged , Refraction, Ocular/physiology , Treatment Outcome , Follow-Up Studies , Young Adult , Postoperative Complications , Time Factors
17.
J Natl Cancer Inst ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38788675

ABSTRACT

PURPOSE: We evaluated whether plasma Alzheimer's Disease (AD)-related biomarkers were associated with cancer-related cognitive decline (CRCD) among older breast cancer survivors. METHODS: We included survivors 60-90 years with primary stage 0-III breast cancers (n = 236) and frequency-matched non-cancer controls (n = 154) who passed a cognitive screen and had banked plasma specimens. Participants were assessed at baseline (pre-systemic therapy) and annually for up to 60-months. Cognition was measured using tests of attention, processing speed and executive function (APE) and learning and memory (LM); perceived cognition was measured by the FACT-Cog PCI. Baseline plasma neurofilament light (NfL), glial fibrillary acidic protein (GFAP), beta-amyloid 42/40 (Aß42/40) and phosphorylated tau (p-tau181) were assayed using single molecule arrays. Mixed models tested associations between cognition and baseline AD-biomarkers, time, group (survivor vs control) and their two- and three-way interactions, controlling for age, race, WRAT4 Word Reading score, comorbidity and BMI; two-sided 0.05 p-values were considered statistically significant. RESULTS: There were no group differences in baseline AD-related biomarkers except survivors had higher baseline NfL levels than controls (p = .013). Survivors had lower adjusted longitudinal APE than controls starting from baseline and continuing over time (p = <0.002). However, baseline AD-related biomarker levels were not independently associated with adjusted cognition over time, except controls had lower APE scores with higher GFAP levels (p = .008). CONCLUSION: The results do not support a relationship between baseline AD-related biomarkers and CRCD. Further investigation is warranted to confirm the findings, test effects of longitudinal changes in AD-related biomarkers and examine other mechanisms and factors affecting cognition pre-systemic therapy.

18.
Clin Ophthalmol ; 18: 1313-1328, 2024.
Article in English | MEDLINE | ID: mdl-38765459

ABSTRACT

Background: Laser therapy has been proven as an effective technique for managing ophthalmological disorders. To guide future research, we conducted a bibliometric analysis of laser applications in eye diseases from 1990 to 2022, aiming to identify key themes and trends. Methods: We retrieved 3027 publications from the Web of Science Core Collection (WoSCC). Bibliometrix was used for science mapping of the literature, while VOSviewer and CiteSpace were applied to visualize co-authorship, co-citation, co-occurrence, and bibliographic coupling networks. Results: From a co-citation reference network, we identified 52 distinct clusters. Our analysis uncovered three main research trends. The first trend revolves around the potential evolution of corneal laser surgery techniques, shifting from the treatment of refractive errors to broader applications in biomedical optics. The second trend illustrates the advancement of laser applications in treating a range of disorders, from retinal and ocular surface diseases to glaucoma. The third trend focuses on the innovative uses of established technologies. Conclusion: This study offers significant insights into the evolution of laser applications in ophthalmology over the past 30 years, which will undoubtedly assist scientists in directing further research in this promising field.

19.
Article in English | MEDLINE | ID: mdl-38753024

ABSTRACT

To evaluate lenticular biomechanical and geometric parameters in Chinese adults with myopia and identify relevant factors using Brillouin microscopy (BM) and Pentacam. The biomechanical and geometric properties of the ocular lenses of Chinese adults with myopia were quantified using BM. Anterior segment images were acquired using a Pentacam. Correlated factors including age, sex, spherical equivalent (SE), intraocular pressure (IOP), axial length (AL), white-to-white ratio (WTW), central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were analyzed. We studied 65 eyes from 65 participants (mean age, 25.23 ± 6.12 years). Width of Top Plateau (WTP), Width of Bottom Plateau (WBP), Slope of Anterior Cortex (SAC), Slope of Posterior Cortex (SPC), and Height of Plateau (Height) metrics obtained using BM showed mean values of 2.597 ± 0.393 mm, 4.310 ± 0.535 mm, 1.344 ± 0.549 GPa/mm, -1.343 ± 0.480 GPa/mm, and 3.373 ± 0.048 GPa, respectively. No significant correlation was found between these parameters and sex, SE, IOP, CCT, ACA, or Height. Interestingly, WBP (r = 0.467, P < 0.001), SAC (r = 0.412, P = 0.001), and SPC (r = -0.280, P = 0.024) were significantly associated with age, and an age-related increase of WBP (slope of 35.36 ± 10.08 µm per year) was identified. Both ACD and ACV showed significant correlations with SAC (r = 0.329 and 0.380, P = 0.008 and 0.002, respectively), but not with SPC. BM provided a novel perspective on lenticular biomechanical and geometric properties in Chinese adults with myopia, which correlated with age, AL, WTW, ACD, and ACV.

20.
Am J Ophthalmol ; 265: 137-146, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38701876

ABSTRACT

PURPOSE: To evaluate the visual outcomes and perioperative complications for cataract surgery in eyes with axial length (AL) >33.0 mm. DESIGN: Prospective clinical cohort study. METHODS: One hundred twenty-two eyes with moderate high myopia (26.0 mm ≤ AL < 28.0 mm, control group), and 118 eyes with extreme high myopia (AL > 33.0 mm, EHM group) were followed up after cataract surgery (1 week and 1 year post-op). Myopic maculopathy grading according to ATN system, best-corrected visual acuity (BCVA), and complications were compared. RESULTS: Postoperatively, BCVA in the EHM group improved significantly at both visits (both P < .001), despite being worse than that of the control group (both P < .05). The EHM group exhibited greater hyperopic refractive errors (P < .001), which were found to be associated with more severe T grade, longer AL, poorer second follow-up BCVA, and smaller anterior capsular opening (ACO) area. A higher incidence of retinal detachment and a more constricted ACO were observed in the EHM group (P = .030 and <.001, respectively), with the latter being significantly associated with longer AL and the absence of capsular tension ring (both P < .05). No difference in BCVA was found between the aphakic and pseudophakic eyes in the EHM group at both visits (both P > .05). CONCLUSION: Cataract surgery improves vision of eyes with AL >33 mm, yet the increased risk of perioperative complications requires attention. Leaving these eyes aphakic might be effective and safe in the long term.