Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 319
Filter
1.
Heliyon ; 10(19): e38322, 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-39398020

ABSTRACT

The early-age temperature rise in concrete, induced by cement hydration, poses a significant risk of thermal cracking. Accurate prediction of concrete hydration temperature is essential for thermal cracking prevention. Cement hydration heat obtained from isothermal calorimetry has been applied to concrete temperature modelling by previous studies. Isothermal calorimetry often excludes coarse aggregates due to the calorimeter capacity limitations, assuming mortar hydration heat can represent concrete, which may neglect the hydration delay effect of coarse aggregates. This study uses an isothermal calorimeter capable of accommodating coarse aggregates to measure the hydration heat of concrete and equivalent mortar, evaluating the validity of this assumption. Results show that the 3-day cumulative hydration heat of concrete exceeds that of mortar, especially at elevated curing temperatures. Significant differences were found in the activation energy and hydration parameters between concrete and mortar, indicating that the presence of coarse aggregates affects samples' temperature sensitivity and hydration heat development. Concrete temperature finite element modelling, validated by semi-adiabatic calorimetry, demonstrates that models based on concrete isothermal calorimetry data provide higher accuracy than those based on mortars. This study demonstrates that the hydration heat development, activation energy, and hydration parameters differ significantly between mortar and concrete. Concrete temperature models based on mortar hydration heat data can result in prediction errors exceeding 5 %. This study recommended employing micro-concrete samples in isothermal calorimetry to replicate actual concrete mixes.

2.
Clin Biomech (Bristol, Avon) ; 120: 106352, 2024 Sep 20.
Article in English | MEDLINE | ID: mdl-39321613

ABSTRACT

BACKGROUND: Oblique lumbar intervertebral fusion aims to decompress spinal nerves via an interbody fusion cage, but the optimal surgical strategy, including implant selection for specific patient characteristics, remains unclear. A biomechanical model was developed to assess how pathophysiological characteristics and instrumentation impact spinal realignment, indirect decompression, and cage subsidence risk. METHODS: A finite element model of the L4-L5 segment was derived from a validated asymptomatic T1-S1 spine model. Five cases of grade I spondylolisthesis with normal or osteoporotic bone densities and initial disc heights of 4.3 to 8.3 mm were simulated. Oblique lumbar intervertebral fusion with cage heights of 10, 12, and 14 mm (12° lordosis) was examined. Postoperative changes in disc height, foraminal and spinal canal dimensions, segmental lordosis, and vertebral slip were assessed. Vertebral stresses and displacements under 10 Nm flexion and 400 N gravitational load were compared between stand-alone constructs and bilateral pedicle screw fixation using rods of 4.75, 5.5, and 6 mm diameters. FINDINGS: Oblique lumbar intervertebral fusion significantly improved postoperative disc height, foraminal and spinal canal dimensions, with the greatest enhancements observed with 14 mm cages. Bilateral pedicle screw fixation markedly reduced cortical endplate stresses and displacements compared to stand-alone constructs, with added benefits from larger rod diameters. Low bone density increased displacements by 63 %. INTERPRETATION: Thicker cages achieve better decompression but increase subsidence risk. Bilateral pedicle screw fixation with 6 mm rods minimizes endplate stresses and displacements, especially in osteoporotic cases. Future research will validate these findings and explore the model's potential for surgical planning.

3.
Polymers (Basel) ; 16(17)2024 Sep 05.
Article in English | MEDLINE | ID: mdl-39274156

ABSTRACT

This study proposes a new, doubly re-entrant auxetic unit-cell design that is based on the widely used auxetic honeycomb structure. Our objective was to develop a structure that preserves and enhances the advantages of the auxetic honeycomb while eliminating all negative aspects. The doubly re-entrant geometry design aims to enhance the mechanical properties, while eliminating the buckling deformation characteristic of the re-entrant deformation mechanism. The effects of the geometric modification are described and evaluated using two parameters, offset and deg. A series of experiments were conducted on a wide range of parameters based on these two parameters. Specimens were printed via the vat photopolymerization process and were subjected to a compression test. Our aim was to investigate the mechanical properties (energy absorption and compressive force) and the deformation behaviour of these specimens in relation to the relevant parameters. The novel geometry achieved the intended properties, outperforming the original auxetic honeycomb structure. Increasing the offset and deg parameters results in increasing the energy absorption capability (up to 767%) and the maximum compressive force (up to 17 times). The right parameter choice eliminates buckling and results in continuous auxetic behaviour. Finally, the parameter dependency of the deformation behaviour was predicted by analytical approximation as well.

4.
Dent Mater ; 40(10): 1669-1676, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39095247

ABSTRACT

The clinical failure mode of dental crown ceramics involves radial cracking at the interface, driven by the surface tension generated from the flexure of the ceramic layer on the subsurface. This results in a reduced lifespan for most all-ceramic dental crowns. Therefore, investigating optimal material combinations to reduce stress concentration in dental crown materials has become crucial for future successful clinical applications. The anisotropic complex structures of natural materials, such as nacre, could potentially create suitable strong and damage-resistant materials. Their imitation of natural structural optimisation and mechanical functionality at both the macro- and micro-levels minimises weaknesses in dental crowns. This research aims to optimise cost-effective, freeze-casted bioinspired composites for the manufacture of novel, strong, and tough ceramic-based dental crowns. To this end, multilayer alumina (Al2O3) composites with four different polymer phases were tested to evaluate their bending behaviour and determine their flexural strength. A computational model was developed and validated against the experimental results. This model includes Al2O3 layers that undergo gentle compression and distribute stress, while the polymer layers act as stress relievers, undergoing plastic deformation to reduce stress concentration. Based on the experimental data and numerical modelling, it was concluded that these composites exhibit variability in mechanical properties, primarily due to differences in microstructures and their flexural strength. Furthermore, the findings suggest that bioinspired Al2O3-based composites demonstrate promising deformation and strengthening behaviour, indicating potential for application in the dental field.


Subject(s)
Aluminum Oxide , Composite Resins , Flexural Strength , Materials Testing , Aluminum Oxide/chemistry , Composite Resins/chemistry , Crowns , Dental Materials/chemistry , Dental Stress Analysis , Polyurethanes/chemistry , Ceramics/chemistry , Methacrylates/chemistry , Polyethylene Glycols/chemistry , Surface Properties , Polymethacrylic Acids/chemistry , Finite Element Analysis , Stress, Mechanical
5.
IEEE Open J Eng Med Biol ; 5: 661-669, 2024.
Article in English | MEDLINE | ID: mdl-39184963

ABSTRACT

Goal: Electrical impedance spectroscopy (EIS) has been suggested as a possible technique to differentiate between thyroid and parathyroid tissue during surgery. This study aims to explore this potential using computational models to simulate the impedance spectra of these tissues, and examine how they are influenced by specific differences in tissue composition and morphology. Materials and methods: Finite element models of thyroid and parathyroid tissues at multiple scales were created, and simulated spectra were compared to existing data collected using ZedScanTM probe during surgery. Geometrical and material properties were varied in a local sensitivity study to assess their relative influence. Results: Both simulated and measured EIS parathyroid spectra show a higher [Formula: see text] dispersion frequency relative to thyroid. However, impedances exhibit overlap at frequencies below 100 kHz. A computational sensitivity study identified uncertainties in extracellular space dimensions, and properties of colloid and fascia compartments as having a significant effect on simulated impedance spectra characteristics. Conclusions: We have demonstrated the utility of our multiscale model in simulating impedance spectra and providing insight into their sensitivity to variations in tissue features. Our results suggest that distinguishing between the thyroid and parathyroid spectra is challenging, but could be improved by constraining the properties of colloid and fascia through further computational or experimental research.

6.
Sensors (Basel) ; 24(14)2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39066080

ABSTRACT

Air pollution has been associated with several health problems. Detecting and measuring the concentration of harmful pollutants present in complex air mixtures has been a long-standing challenge, due to the intrinsic difficulty of distinguishing among these substances from interferent species and environmental conditions, both indoor and outdoor. Despite all efforts devoted by the scientific and industrial communities to tackling this challenge, the availability of suitable device technologies able to selectively discriminate these pollutants present in the air at minute, yet dangerous, concentrations and provide a quantitative measure of their concentrations is still an unmet need. Thermal conductivity detectors (TCDs) show promising characteristics that make them ideal gas sensing tools capable of recognising different gas analytes based on their physical fingerprint characteristics at the molecular level, such as their density, thermal conductivity, dynamic viscosity, and others. In this paper, the operation of TCD gas sensors is presented and explored using a finite element simulation of Joule heating in a sensing electrode placed in a gas volume. The results obtained show that the temperature, and hence, the resistance of the individual suspended microbridge sensor device, depends on the surrounding gas and its thermal conductivity, while the sensitivity and power consumption depend on the properties of the constitutive metal. Moreover, the electrode resistance is proven to be linearly dependent on the applied voltage.

7.
J Mech Behav Biomed Mater ; 157: 106634, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38945119

ABSTRACT

Micro finite-element (µFE) simulations serve as a crucial research tool to assist laboratory experiments in the biomechanical assessment of screw anchorage in bone. However, accurately modelling the interface between bone and screw threads at the microscale poses a significant challenge. Currently, the gold-standard approach involves employing computationally intensive physical contact models to simulate this interface. This study compared nonlinear µFE predictions of deformations, whole-construct stiffness, maximum force and damage patterns of three different computationally efficient simplified interface approaches to the general contact interface in Abaqus Explicit, which was defined as gold-standard and reference model. The µCT images (resolution: 32.8 µm) of two human radii with varying bone volume fractions were utilized and a screw was virtually inserted up to 50% and 100% of the volar-dorsal cortex distance. Materially nonlinear µFE models were generated and loaded in tension, compression and shear. In a first step, the common simplification of using a fully-bonded interface was compared to the general contact interface, revealing overestimations of whole-construct stiffness (19% on average) and maximum force (26% on average), along with inaccurate damage pattern replications. To enhance predictions, two additional simplified interface models were compared: tensionally strained element deletion (TED) and a novel modification of TED (TED-M). TED deletes interface elements strained in tension based on a linear-elastic simulation before the actual simulation. TED-M extends the remaining contact interface of TED by incorporating neighboring elements to the contact area. Both TED and TED-M reduced the errors in whole-construct stiffness and maximum force and improved the replication of the damage distributions in comparison to the fully-bonded approach. TED was better in predicting whole-construct stiffness (average error of 1%), while TED-M showed lowest errors in maximum force (1% on average). In conclusion, both TED and TED-M offer computationally efficient alternatives to physical contact modelling, although the fully-bonded interface may deliver sufficiently accurate predictions for many applications.


Subject(s)
Bone Screws , Finite Element Analysis , Humans , Nonlinear Dynamics , Mechanical Phenomena , Biomechanical Phenomena , Materials Testing , Stress, Mechanical , X-Ray Microtomography
8.
Dermatol Ther (Heidelb) ; 14(5): 1189-1210, 2024 May.
Article in English | MEDLINE | ID: mdl-38703308

ABSTRACT

INTRODUCTION: In dermatology, inflammatory skin conditions impose a substantial burden worldwide, with existing therapies showing limited efficacy and side effects. This report aims to compare a novel immunological activation induced by hyperthermic 20 MHz high intensity focused ultrasound (HIFU) with conventional cryotherapy. The bioeffects from the two methods are initially investigated by numerical models, and subsequently compared to clinical observations after treatment of a patient with the inflammatory disease granuloma annulare (GA). METHODS: Clinical responses to moderate energy HIFU and cryotherapy were analysed using numerical models. HIFU-induced pressure and heat transfer were calculated, and a three-layer finite element model simulated temperature distribution and necrotic volume in the skin. Model output was compared to 22 lesions treated with HIFU and 10 with cryotherapy in a patient with GA. RESULTS: Cryotherapy produced a necrotic volume of 138.5 mm3 at - 92.7 °C. HIFU at 0.3-0.6 J/exposure and focal depths of 0.8 or 1.3 mm generated necrotic volumes up to only 15.99 mm3 at temperatures of 68.3-81.2 °C. HIFU achieved full or partial resolution in all treated areas, confirming its hyperthermic immunological activation effect, while cryotherapy also resolved lesions but led to scarring and dyspigmentation. CONCLUSION: Hyperthermic immunological activation of 20 MHz HIFU shows promise for treating inflammatory skin conditions as exemplified by GA. Numerical models demonstrate minimal skin necrosis compared to cryotherapy. Suggested optimal HIFU parameters are 1.3 mm focal depth, 0.4-0.5 J/exposure, 1 mm spacing, and 1 mm margin. Further studies on GA and other inflammatory diseases are recommended.

9.
Front Bioeng Biotechnol ; 12: 1324802, 2024.
Article in English | MEDLINE | ID: mdl-38712332

ABSTRACT

The fallopian tubes play an important role in human fertility by facilitating the spermatozoa passage to the oocyte as well as later actively facilitating the fertilized oocyte transportation to the uterus cavity. The fallopian tubes undergo changes involving biological, physical, and morphological processes due to women aging, which may impair fertility. Here, we have modelled fallopian tubes of women at different ages and evaluated the chances of normal and pathological sperm cells reaching the fertilization site, the ampulla. By utilizing a unique combination of simulative tools, we implemented dynamic three-dimensional (3D) detailed geometrical models of many normal and pathological sperm cells swimming together in 3D geometrical models of three fallopian tubes associated with different women's age groups. By tracking the sperm cell swim, we found that for all age groups, the number of normal sperm cells in the ampulla is the largest, compared with the pathological sperm cells. On the other hand, the number of normal sperm cells in the fertilization site decreases due to the morphological and mechanical changes that occur in the fallopian tube with age. Moreover, in older ages, the normal sperm cells swim with lower velocities and for shorter distances inside the ampulla toward the ovary. Thus, the changes that the human fallopian tube undergoes due to women's aging have a significant influence on the human sperm cell motility. Our model of sperm cell motility through the fallopian tube in relation to the woman's age morphological changes provides a new scope for the investigation and treatment of diseases and infertility cases associated with aging, as well as a potential personalized medicine tool for evaluating the chances of a natural fertilization per specific features of a man's sperm and a woman's reproductive system.

10.
J Exp Biol ; 227(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38725420

ABSTRACT

A fatigue-failure process is hypothesized to govern the development of tibial stress fractures, where bone damage is highly dependent on the peak strain magnitude. To date, much of the work examining tibial strain during running has ignored uphill and downhill running despite the prevalence of this terrain. This study examined the sensitivity of tibial strain to changes in running grade and speed using a combined musculoskeletal-finite element modelling routine. Seventeen participants ran on a treadmill at ±10, ±5 and 0 deg; at each grade, participants ran at 3.33 m s-1 and at a grade-adjusted speed of 2.50 and 4.17 m s-1 for uphill and downhill grades, respectively. Force and motion data were recorded in each grade and speed combination. Muscle and joint contact forces were estimated using inverse-dynamics-based static optimization. These forces were applied to a participant-adjusted finite element model of the tibia. None of the strain variables (50th and 95th percentile strain and strained volume ≥4000 µÎµ) differed as a function of running grade; however, all strain variables were sensitive to running speed (F1≥9.59, P≤0.03). In particular, a 1 m s-1 increase in speed resulted in a 9% (∼260 µÎµ) and 155% (∼600 mm3) increase in peak strain and strained volume, respectively. Overall, these findings suggest that faster running speeds, but not changes in running grade, may be more deleterious to the tibia.


Subject(s)
Running , Tibia , Running/physiology , Humans , Male , Tibia/physiology , Biomechanical Phenomena , Adult , Female , Young Adult , Finite Element Analysis , Stress, Mechanical
11.
Comput Biol Med ; 177: 108633, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38805810

ABSTRACT

BACKGROUND: Endoscopic strip craniectomy followed by helmet therapy (ESCH) is a minimally invasive approach for correcting sagittal craniosynostosis. The treatment involves a patient-specific helmet designed to facilitate lateral growth while constraining sagittal expansion. In this study, finite element modelling was used to predict post-treatment head reshaping, improving our comprehension of the necessary helmet therapy duration. METHOD: Six patients (aged 11 weeks to 9 months) who underwent ESCH at Connecticut Children's Hospital were enrolled in this study. Day-1 post-operative 3D scans were used to create skin, skull, and intracranial volume models. Patient-specific helmet models, incorporating areas for growth, were designed based on post-operative imaging. Brain growth was simulated through thermal expansion, and treatments were modelled according to post-operative Imaging available. Mechanical testing and finite element modelling were combined to determine patient-specific mechanical properties from bone samples collected from surgery. Validation compared simulated end-of-treatment skin surfaces with optical scans in terms of shape matching and cranial index estimation. RESULTS: Comparison between the simulated post-treatment head shape and optical scans showed that on average 97.3 ± 2.1 % of surface data points were within a distance range of -3 to 3 mm. The cranial index was also accurately predicted (r = 0.91). CONCLUSIONS: In conclusion, finite element models effectively predicted the ESCH cranial remodeling outcomes up to 8 months postoperatively. This computational tool offers valuable insights to guide and refine helmet treatment duration. This study also incorporated patient-specific material properties, enhancing the accuracy of the modeling approach.


Subject(s)
Craniosynostoses , Head Protective Devices , Humans , Craniosynostoses/surgery , Craniosynostoses/diagnostic imaging , Infant , Male , Female , Craniotomy , Computer Simulation , Finite Element Analysis , Endoscopy/methods , Head/diagnostic imaging , Head/surgery
12.
Article in English | MEDLINE | ID: mdl-38695541

ABSTRACT

Within the past decade, injuries caused by electric scooter (e-scooter) crashes have significantly increased. A common cause of fatalities for e-scooter riders is a collision between a car and an e-scooter. To develop a better understanding of the complex injury mechanisms in these collisions, four crashes between an e-scooter and a family car/sedan and a sports utility vehicle were simulated using finite element models. The vehicles impacted the e-scooter at a speed of 30 km/hr in a perpendicular collision, and at 15 degrees towards the vehicle, to simulate a rider being struck by a turning vehicle. The risks of serious injury to the rider were low for the head, brain, and neck, but femur/tibia fractures were observed in all simulations. The primary cause of head and brain injuries was found to be the head-ground impact in cases where such an impact occurred.

13.
Biomech Model Mechanobiol ; 23(3): 1031-1053, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38619712

ABSTRACT

The subject-specific range of motion (RoM) of a musculoskeletal joint system is balanced by pre-tension levels of individual muscles, which affects their contraction capability. Such an inherent pre-tension or pre-stretch of muscles is not measureable with in vivo experiments. Using a 3D continuum mechanical forward simulation approach for motion analysis of the musculoskeletal system of the forearm with 3 flexor and 2 extensor muscles, we developed an optimization process to determine the muscle fibre pre-stretches for an initial arm position, which is given human dataset. We used RoM values of a healthy person to balance the motion in extension and flexion. The performed sensitivity study shows that the fibre pre-stretches of the m. brachialis, m. biceps brachii and m. triceps brachii with 91 % dominate the objective flexion ratio, while m. brachiradialis and m. anconeus amount 7.8 % and 1.2 % . Within the multi-dimensional space of the surrogate model, 3D sub-spaces of primary variables, namely the dominant muscles and the global objective, flexion ratio, exhibit a path of optimal solutions. Within this optimal path, the muscle fibre pre-stretch of two flexors demonstrate a negative correlation, while, in contrast, the primary extensor, m. triceps brachii correlates positively to each of the flexors. Comparing the global optimum with four other designs along the optimal path, we saw large deviations, e.g., up to 15 ∘ in motion and up to 40% in muscle force. This underlines the importance of accurate determination of fibre pre-stretch in muscles, especially, their role in pathological muscular disorders and surgical applications such as free muscle or tendon transfer.


Subject(s)
Joints , Models, Biological , Range of Motion, Articular , Humans , Range of Motion, Articular/physiology , Joints/physiology , Biomechanical Phenomena , Muscle, Skeletal/physiology , Musculoskeletal System/anatomy & histology , Computer Simulation , Muscle Contraction/physiology , Male
14.
J Funct Biomater ; 15(4)2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38667558

ABSTRACT

This study aims to analyse, using a finite element analysis, the effects of Ti-base abutment height on the distribution and magnitude of transferred load and the resulting bone microstrain in the bone-implant system. A three-dimensional bone model of the mandibular premolar section was created with an implant placed in a juxta-osseous position. Three prosthetic models were designed: a 1 mm-high titanium-base (Ti-base) abutment with an 8 mm-high cemented monolithic zirconia crown was designed for model A, a 2 mm-high Ti-base abutment with a 7 mm-high crown for model B, and a 3 mm-high abutment with a 6 mm-high crown for model C. A static load of 150 N was applied to the central fossa at a six-degree angle with respect to the axial axis of the implant to evaluate the magnitude and distribution of load transfer and microstrain. The results showed a trend towards a direct linear association between the increase in the height of the Ti-base abutments and the increase in the transferred stress and the resulting microstrain to both the prosthetic elements and the bone/implant system. An increase in transferred stress and deformation of all elements of the system, within physiological ranges, was observed as the size of the Ti-base abutment increased.

15.
Materials (Basel) ; 17(3)2024 Feb 05.
Article in English | MEDLINE | ID: mdl-38591660

ABSTRACT

Self-healing cementitious materials containing microcapsules filled with healing agents can autonomously seal cracks and restore structural integrity. However, optimising the microcapsule mechanical properties to survive concrete mixing whilst still rupturing at the cracked interface to release the healing agent remains challenging. This study develops an integrated numerical modelling and machine learning approach for tailoring acrylate-based microcapsules for triggering within cementitious matrices. Microfluidics is first utilised to produce microcapsules with systematically varied shell thickness, strength, and cement compatibility. The capsules are characterised and simulated using a continuum damage mechanics model that is able to simulate cracking. A parametric study investigates the key microcapsule and interfacial properties governing shell rupture versus matrix failure. The simulation results are used to train an artificial neural network to rapidly predict the triggering behaviour based on capsule properties. The machine learning model produces design curves relating the microcapsule strength, toughness, and interfacial bond to its propensity for fracture. By combining advanced simulations and data science, the framework connects tailored microcapsule properties to their intended performance in complex cementitious environments for more robust self-healing concrete systems.

16.
Materials (Basel) ; 17(7)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38612023

ABSTRACT

A typical piezoelectric energy harvester is a bimorph cantilever with two layers of piezoelectric material on both sides of a flexible substrate. Piezoelectric layers of lead-based materials, typically lead zirconate titanate, have been mainly used due to their outstanding piezoelectric properties. However, due to lead toxicity and environmental problems, there is a need to replace them with environmentally benign materials. Here, our main efforts were focused on the preparation of hafnium-doped barium titanate (BaHfxTi1-xO3; BHT) sol-gel materials. The original process developed makes it possible to obtain a highly concentrated sol without strong organic complexing agents. Sol aging and concentration can be controlled to obtain a time-stable sol for a few months at room temperature, with desired viscosity and colloidal sizes. Densified bulk materials obtained from this optimized sol are compared with a solid-state synthesis, and both show good electromechanical properties: their thickness coupling factor kt values are around 53% and 47%, respectively, and their converse piezoelectric coefficient d33∗ values are around 420 and 330 pm/V, respectively. According to the electromechanical properties, the theoretical behavior in a bimorph configuration can be simulated to predict the resonance and anti-resonance frequencies and the corresponding output power values to help to design the final device. In the present case, the bimorph configuration based on BHT sol-gel material is designed to harvest ambient vibrations at low frequency (<200 Hz). It gives a maximum normalized volumetric power density of 0.03 µW/mm3/Hz/g2 at 154 Hz under an acceleration of 0.05 m/s2.

17.
Sensors (Basel) ; 24(7)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38610409

ABSTRACT

Electrical impedance spectroscopy (EIS) has been proposed as a promising noninvasive method to differentiate healthy thyroid from parathyroid tissues during thyroidectomy. However, previously reported similarities in the in vivo measured spectra of these tissues during a pilot study suggest that this separation may not be straightforward. We utilise computational modelling as a method to elucidate the distinguishing characteristics in the EIS signal and explore the features of the tissue that contribute to the observed electrical behaviour. Firstly, multiscale finite element models (or 'virtual tissue constructs') of thyroid and parathyroid tissues were developed and verified against in vivo tissue measurements. A global sensitivity analysis was performed to investigate the impact of physiological micro-, meso- and macroscale tissue morphological features of both tissue types on the computed macroscale EIS spectra and explore the separability of the two tissue types. Our results suggest that the presence of a surface fascia layer could obstruct tissue differentiation, but an analysis of the separability of simulated spectra without the surface fascia layer suggests that differentiation of the two tissue types should be possible if this layer is completely removed by the surgeon. Comprehensive in vivo measurements are required to fully determine the potential for EIS as a method in distinguishing between thyroid and parathyroid tissues.


Subject(s)
Dielectric Spectroscopy , Thyroid Gland , Thyroid Gland/surgery , Pilot Projects , Computer Simulation , Electricity
18.
R Soc Open Sci ; 11(4): 231158, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38577216

ABSTRACT

Sagittal craniosynostosis (SC) is a congenital condition whereby the newborn skull develops abnormally owing to the premature ossification of the sagittal suture. Spring-assisted cranioplasty (SAC) is a minimally invasive surgical technique to treat SC, where metallic distractors are used to reshape the newborn's head. Although safe and effective, SAC outcomes remain uncertain owing to the limited understanding of skull-distractor interaction and the limited information provided by the analysis of single surgical cases. In this work, an SC population-averaged skull model was created and used to simulate spring insertion by means of the finite-element analysis using a previously developed modelling framework. Surgical parameters were varied to assess the effect of osteotomy and spring positioning, as well as distractor combinations, on the final skull dimensions. Simulation trends were compared with retrospective measurements from clinical imaging (X-ray and three-dimensional photogrammetry scans). It was found that the on-table post-implantation head shape change is more sensitive to spring stiffness than to the other surgical parameters. However, the overall end-of-treatment head shape is more sensitive to spring positioning and osteotomy size parameters. The results of this work suggest that SAC surgical planning should be performed in view of long-term results, rather than immediate on-table reshaping outcomes.

19.
Ann Biomed Eng ; 52(8): 1982-1990, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38503945

ABSTRACT

The process of lens shape change in the eye to alter focussing (accommodation) is still not fully understood. Modelling approaches have been used to complement experimental findings in order to determine how constituents in the accommodative process influence the shape change of the lens. An unexplored factor in modelling is the role of the modelling software on the results of simulated shape change. Finite element models were constructed in both Abaqus and Ansys software using biological parameters from measurements of shape and refractive index of two 35-year-old lenses. The effect of zonular insertion on simulated shape change was tested on both 35-year-old lens models and with both types of software. Comparative analysis of shape change, optical power, and stress distributions showed that lens shape and zonular insertion positions affect the results of simulated shape change and that Abaqus and Ansys show differences in their respective models. The effect of the software package used needs to be taken into account when constructing finite element models and deriving conclusions.


Subject(s)
Finite Element Analysis , Lens, Crystalline , Models, Biological , Lens, Crystalline/physiology , Lens, Crystalline/anatomy & histology , Humans , Computer Simulation , Accommodation, Ocular/physiology , Adult , Software
20.
J Mech Behav Biomed Mater ; 153: 106474, 2024 May.
Article in English | MEDLINE | ID: mdl-38447273

ABSTRACT

Total Hip Arthroplasty has been a revolutionary technique in restoring mobility to patients with damaged hip joints. The introduction of modular components of the hip prosthesis allowed for bespoke solutions based on the requirements of the patient. The femoral stem is designed with a conical trunnion to allow for assembly of different femoral head sizes based on surgical requirements. The femoral head diameters for a metal-on-polyethylene hip prosthesis have typically ranged between 22 mm and 36 mm and are typically manufactured using Cobalt-Chromium alloy. A smaller femoral head diameter is associated with lower wear of the polyethylene, however, there is a higher risk of dislocation. In this study, a finite element model of a standard commercial hip arthroplasty prosthesis was modelled with femoral head diameters ranging from 22 mm to 36 mm to investigate the wear evolution and material loss at both contacting surfaces (acetabular cup and femoral stem trunnion). The finite element model, coupled with a validated in-house wear algorithm modelled a human walking for 10 million steps. The results have shown that as the femoral head size increased, the amount of wear on all contacting surfaces increased. As the femoral head diameter increased from 22 mm to 36 mm, the highly cross-linked polyethylene (XLPE) volumetric wear increased by 61% from 98.6 mm3 to 159.5 mm3 while the femoral head taper surface volumetric wear increased by 21% from 4.18 mm3 to 4.95 mm3. This study has provided an insight into the amount of increased wear as the femoral head size increased which can highlight the life span of these prostheses in the human body.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Femur Head , Finite Element Analysis , Prosthesis Design , Prosthesis Failure , Polyethylene , Chromium Alloys
SELECTION OF CITATIONS
SEARCH DETAIL