BMJ Open Respir Res ; 11(1)2024 May 22.
Article in English | MEDLINE | ID: mdl-38777583

ABSTRACT

INTRODUCTION: Asthma attacks are a leading cause of morbidity and mortality but are preventable in most if detected and treated promptly. However, the changes that occur physiologically and behaviourally in the days and weeks preceding an attack are not always recognised, highlighting a potential role for technology. The aim of this study 'DIGIPREDICT' is to identify early digital markers of asthma attacks using sensors embedded in smart devices including watches and inhalers, and leverage health and environmental datasets and artificial intelligence, to develop a risk prediction model to provide an early, personalised warning of asthma attacks. METHODS AND ANALYSIS: A prospective sample of 300 people, 12 years or older, with a history of a moderate or severe asthma attack in the last 12 months will be recruited in New Zealand. Each participant will be given a smart watch (to assess physiological measures such as heart and respiratory rate), peak flow meter, smart inhaler (to assess adherence and inhalation) and a cough monitoring application to use regularly over 6 months with fortnightly questionnaires on asthma control and well-being. Data on sociodemographics, asthma control, lung function, dietary intake, medical history and technology acceptance will be collected at baseline and at 6 months. Asthma attacks will be measured by self-report and confirmed with clinical records. The collected data, along with environmental data on weather and air quality, will be analysed using machine learning to develop a risk prediction model for asthma attacks. ETHICS AND DISSEMINATION: Ethical approval has been obtained from the New Zealand Health and Disability Ethics Committee (2023 FULL 13541). Enrolment began in August 2023. Results will be presented at local, national and international meetings, including dissemination via community groups, and submission for publication to peer-reviewed journals. TRIAL REGISTRATION NUMBER: Australian New Zealand Clinical Trials Registry ACTRN12623000764639; Australian New Zealand Clinical Trials Registry.


Subject(s)
Artificial Intelligence , Asthma , Adolescent , Adult , Child , Female , Humans , Male , Nebulizers and Vaporizers , New Zealand , Observational Studies as Topic , Prospective Studies
2.
Cureus ; 16(4): e58670, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38774171

ABSTRACT

INTRODUCTION: Chronic obstructive pulmonary disease (COPD) and bronchial asthma pose significant threats and challenges to global health care, emphasizing the need for precise inhaler therapies to overcome this burden. The optimal peak inspiratory flow rate (PIFR) is a crucial determinant for the right selection and effective use of an inhaler device. It also helps to improve the treatment effectiveness of obstructive airway diseases worldwide as it allows effective drug delivery to distal airways and lung parenchyma. It is used as a selection criterion by physicians around the world for selecting personalized inhaler devices. OBJECTIVE: To find out the optimal and non-optimal PIFR prevalence and its influencing factors in stable and exacerbation phases of COPD and bronchial asthma in Tamil Nadu, India. METHODOLOGY: It is a single-center, observational, cross-sectional study conducted from February 2022 to August 2023. The patients who meet the diagnostic criteria specified by the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines for COPD and the Global Initiative for Asthma (GINA) guidelines for bronchial asthma are enrolled in our study. The PIFR was measured using a hand-held digital spirometry device, along with demographic data collection. Statistical analyses, including t-tests and chi-square tests, were performed using SPSS version 21 (IBM Corp., Armonk, NY). RESULTS: Gender, height, and disease severity significantly impacted the PIFR. Females, normal BMI individuals, and those with moderate disease severity exhibited higher optimal PIFR rates. Stable or exacerbation phases, disease, and smoking status do not influence either optimal or non-optimal PIFR. Notably, substantial differences in lung function parameters were observed between optimal (60-90 L/min) and non-optimal PIFR (insufficient: <30 L/min, suboptimal: 30-60 L/min, excessive: >90 L/min) groups, highlighting their impact on respiratory health. CONCLUSION: This study emphasizes the importance of personalized inhaler strategies, considering gender, height, and disease severity. Proper inhaler device selection, continuous monitoring of inhaler technique, and tailored inhaler education at every OPD visit are vital for optimizing effective COPD and bronchial asthma management and improving adherence to treatment.

3.
BMJ Open Respir Res ; 11(1)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38626929

ABSTRACT

BACKGROUND: Errors using inhaled delivery systems for COPD are common and it is assumed that these lead to worse clinical outcomes. Previous systematic reviews have included patients with both asthma and COPD and much of the evidence related to asthma. More studies in COPD have now been published. Through systematic review, the relationship between errors using inhalers and clinical outcomes in COPD, including the importance of specific errors, was assessed.MethodsElectronic databases were searched on 27 October 2023 to identify cohort, case-control or randomised controlled studies, which included patients with COPD, an objective assessment of inhaler errors and data on at least one outcome of interest (forced expiratory volume in 1 s, (FEV1), dyspnoea, health status and exacerbations). Study quality was assessed using the Newcastle and Ottawa scales. A narrative synthesis of the results was performed as there was insufficient detail in the publications to allow quantitative synthesis. There was no funding for the review. RESULTS: 19 publications were included (7 cohort and 12 case-control) reporting outcomes on 6487 patients. 15 were considered low quality, and most were confounded by the absence of adherence data. There was weak evidence that lower error rates are associated with better FEV1, symptoms and health status and fewer exacerbations. Only one considered the effects of individual errors and found that only some were related to worse outcomes. CONCLUSION: Evidence about the importance of specific errors using inhalers and outcomes would optimise the education and training of patients with COPD. Prospective studies, including objective monitoring of inhalation technique and adherence, are needed. PROSPERO REGISTRATION NUMBER: CRD42023393120.


Subject(s)
Nebulizers and Vaporizers , Pulmonary Disease, Chronic Obstructive , Pulmonary Disease, Chronic Obstructive/drug therapy , Humans , Administration, Inhalation , Medication Errors , Forced Expiratory Volume , Bronchodilator Agents/administration & dosage , Treatment Outcome
4.
BMJ Open Respir Res ; 11(1)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38642917

ABSTRACT

BACKGROUND: Inhaler concordance and the peak inspiratory flow rate (PIFR) are important determinants of treatment effects in patients with chronic airway diseases. Adequate PIFR is required for driving aerosol medication into the lower respiratory tract. However, the relationship between them has not been discussed previously. This study aimed to describe the characteristics of inhaler concordance and PIFR in Chinese patients with chronic airway diseases and discuss the associated variables and the relationship between them. METHODS: In this single-centre, observational study, a total of 680 patients with chronic airway diseases were enrolled from July 2021 to April 2023. We collected data on the socio-demographic and clinical variables of inhaler concordance using the test of adherence to inhalers (TAI) and PIFR. Multivariate logistic regression was conducted to examine variables related to inhaler concordance and PIFR. RESULTS: A total of 49.4% of patients had low concordance. Patients with chronic obstructive pulmonary disease (COPD) were more concordant than patients with asthma (mean TAI score: 43.60 vs 41.20; p<0.01), while there was no difference in concordance between the asthma-COPD overlap group and the asthma or COPD group. Suboptimal PIFR (adjusted OR, 1.61; 95% CI 1.04 to 2.51) increased the risk of poor concordance among all patients, while triple therapy (adjusted OR, 0.60; 95% CI 0.35 to 0.86) reduced the risk. A total of 54.9% of patients had suboptimal PIFR. Older age, lower educational level, use of dry powder inhalers and lower forced expiratory volume in 1 s % predicted were significantly correlated with insufficient PIFR. Subgroup analysis revealed a greater proportion of patients with insufficient PIFR during exacerbation than during the stable phase (61.7% vs 43.5%, p<0.001). CONCLUSION: Inhaler concordance was low, and suboptimal PIFR was a risk factor for poor concordance among Chinese patients with chronic airway diseases. In addition, current inhalation devices may not be suitable, and PIFR reassessment should be considered for patients with COPD during exacerbation. TRIAL REGISTRATION NUMBER: The study was registered in chictr.org.cn (ChiCTR2100052527) on 31 October 2021.


Subject(s)
Asthma , Pulmonary Disease, Chronic Obstructive , Humans , Respiratory Aerosols and Droplets , Pulmonary Disease, Chronic Obstructive/therapy , Asthma/drug therapy , Dry Powder Inhalers , Risk Factors
5.
Can J Hosp Pharm ; 77(2): e3507, 2024.
Article in English | MEDLINE | ID: mdl-38601135

ABSTRACT

Background: The choice of inhaler device type can play a crucial role in managing asthma and chronic obstructive pulmonary disease (COPD). With various devices available, differences in choice and application may lead to confusion for both prescribers and patients. Furthermore, improper use of a device may lead to suboptimal or inadequate treatment. Objectives: The primary objective was to identify factors that prescribers consider when selecting an inhaler device for a patient. The secondary objective was to evaluate the rankings of these factors, including identification of which factors had greater importance and frequency for prescribers' choice of inhaler device for patients. Methods: A 10-question online survey was developed and distributed in late 2021 to prescribers (physicians, nurse practitioners, and pharmacists) in western Canada in an outpatient setting. Prescribers were asked to use their own words to describe the factors they considered important and were then asked to rank the stated factors in order of importance for 2 scenarios: an 83-year-old woman with COPD and a 21-year-old man with asthma. The results were examined qualitatively and quantitatively. Recurring themes were identified, and each response was categorized on the basis of its corresponding theme. Results: In all, 82 respondents completed the survey (yielding a total of 164 responses across the 2 scenarios). Overall, prescriber experience (84/164, 51%), cost (84/164, 51%), patient ease of use (59/164, 36%), and other patient considerations (49/164, 30%) were the factors most frequently mentioned. The prescriber's experience was most often mentioned as a factor for scenario 1 (COPD), whereas cost was most often mentioned for scenario 2 (asthma). In both scenarios, prescriber experience was the highest-ranked factor. Conclusions: When determining the appropriate type of inhaler device, respondents frequently prioritized their own experience, as well as cost and ease of use. However, many respondents ranked prescriber experience higher than all other factors.


Contexte: Le choix du type d'inhalateur peut jouer un rôle crucial dans la gestion de l'asthme et de la maladie pulmonaire obstructive chronique (MPOC). Étant donné la diversité des dispositifs disponibles, les différences de choix et d'application peuvent prêter à confusion tant pour les prescripteurs que pour les patients. De plus, la mauvaise utilisation d'un appareil peut conduire à un traitement sous-optimal ou inadéquat. Objectifs: L'objectif principal consistait à identifier les facteurs pris en compte par les prescripteurs lors de la sélection de l'inhalateur pour un patient. L'objectif secondaire consistait à évaluer le classement de ces facteurs, notamment l'identification des facteurs les plus importants et des inhalateurs les plus fréquemment choisis par les prescripteurs. Méthodes: Un sondage en ligne de 10 questions a été préparé et distribué fin 2021 aux prescripteurs (médecins, infirmières praticiennes et pharmaciens) de l'ouest du Canada en milieu ambulatoire. Les prescripteurs devaient, dans leurs propres mots, décrire les facteurs qui leur semblaient importants avant de les classer par ordre d'importance dans le cadre de deux scénarios : une femme de 83 ans atteinte de MPOC et un homme de 21 ans avec de l'asthme. Les résultats ont fait l'objet d'un examen qualitatif et quantitatif. Des thèmes récurrents ont été identifiés et chaque réponse a été catégorisée en fonction du thème correspondant. Résultats: Au total, 82 répondants ont répondu au sondage (total de 164 réponses dans les 2 scénarios). Dans l'ensemble, l'expérience du prescripteur (84/164, 51 %), le coût (84/164, 51 %), la facilité d'utilisation pour le patient (59/164, 36 %) et d'autres considérations en rapport avec le patient (49/164, 30 %) étaient les facteurs déterminants les plus fréquemment mentionnés. Pour le scénario 1 (MPOC), l'expérience du prescripteur était le facteur le plus souvent mentionné, alors que le coût l'était pour le scénario 2 (asthme). Dans les deux scénarios, l'expérience du prescripteur était le facteur le plus important. Conclusions: Lors de la détermination du type d'inhalateur approprié, les répondants ont souvent donné la priorité à leur expérience personnelle, ainsi qu'au coût et à la facilité d'utilisation. Cependant, de nombreux répondants ont accordé une note plus élevée à l'expérience du prescripteur qu'à d'autres facteurs.

6.
Thorax ; 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38413192

ABSTRACT

BACKGROUND: Poorly controlled asthma is associated with increased morbidity and healthcare resource utilisation (HCRU). Therefore, to quantify the environmental impact of asthma care, this retrospective, cohort, healthCARe-Based envirONmental cost of treatment (CARBON) study estimated greenhouse gas (GHG) emissions in the UK associated with the management of well-controlled versus poorly controlled asthma. METHODS: Patients with current asthma (aged ≥12 years) registered with the Clinical Practice Research Datalink (2008‒2019) were included. GHG emissions, measured as carbon dioxide equivalent (CO2e), were estimated for asthma-related medication use, HCRU and exacerbations during follow-up of patients with asthma classified at baseline as well-controlled (<3 short-acting ß2-agonist (SABA) canisters/year and no exacerbations) or poorly controlled (≥3 SABA canisters/year or ≥1 exacerbation). Excess GHG emissions due to suboptimal asthma control included ≥3 SABA canister prescriptions/year, exacerbations and any general practitioner and outpatient visits within 10 days of hospitalisation or an emergency department visit. RESULTS: Of the 236 506 patients analysed, 47.3% had poorly controlled asthma at baseline. Scaled to the national level, the overall carbon footprint of asthma care in the UK was 750 540 tonnes CO2e/year, with poorly controlled asthma contributing excess GHG emissions of 303 874 tonnes CO2e/year, which is equivalent to emissions from >124 000 houses in the UK. Poorly controlled versus well-controlled asthma generated 3.1-fold higher overall and 8.1-fold higher excess per capita carbon footprint, largely SABA-induced, with smaller contributions from HCRU. CONCLUSIONS: These findings suggest that addressing the high burden of poorly controlled asthma, including curbing high SABA use and its associated risk of exacerbations, may significantly alleviate asthma care-related carbon emissions.

7.
Thorax ; 79(5): 395-402, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38184370

ABSTRACT

BACKGROUND: The potential association between the use of inhaled corticosteroids (ICS) and the risk of pneumonia among adults is disputed and paediatric-specific evidence is scarce. AIM: To assess the potential association between ICS, use and the risk of hospitalisation for pneumonia among children (age 2-17 years) with asthma. METHODS: This was a cohort study based on nationwide data from routine clinical practice in Sweden (January 2007 to November 2021). From 425 965 children with confirmed asthma, episodes of new ICS use and no use were identified using records of dispensed drugs. We adjusted for potential confounders with propensity score overlap weighting and the risk of a hospitalisation with pneumonia as primary diagnosis was estimated. Multiple subgroup and sensitivity analyses were also performed. RESULTS: We identified 249 351 ICS (mean follow-up of 0.9 years) and 214 840 no-use (mean follow-up of 0.7 years) episodes. During follow-up, 369 and 181 events of hospitalisation for pneumonia were observed in the ICS and no-use episodes, respectively. The weighted incidence rates of hospitalisation for pneumonia was 14.5 per 10 000 patient-years for ICS use episodes and 14.6 for no-use episodes. The weighted HR for hospitalisation for pneumonia associated with ICS use was 1.06 (95% CI 0.88 to 1.28) and the absolute rate difference was -0.06 (95% CI -2.83 to 2.72) events per 10 000 patient-years, compared with no use. CONCLUSIONS: In this nationwide cohort study, we found no evidence of an association between ICS use and the risk of hospitalisation for pneumonia among children with asthma, as compared with no use.


Subject(s)
Anti-Asthmatic Agents , Asthma , Pneumonia , Adult , Child , Humans , Child, Preschool , Adolescent , Anti-Asthmatic Agents/therapeutic use , Cohort Studies , Administration, Inhalation , Asthma/drug therapy , Asthma/epidemiology , Adrenal Cortex Hormones/adverse effects , Hospitalization , Pneumonia/chemically induced , Pneumonia/epidemiology
8.
BMJ Open Respir Res ; 11(1)2024 01 06.
Article in English | MEDLINE | ID: mdl-38184317

ABSTRACT

BACKGROUND: Inhaled corticosteroids have been widely reported as a preventive measure against the development of severe forms of COVID-19 not only in patients with asthma. METHODS: In 654 Czech and Slovak patients with asthma who developed COVID-19, we investigated whether the correct use of inhaler containing corticosteroids was associated with a less severe course of COVID-19 and whether this had an impact on the need for hospitalisation, measurable lung functions and quality of life (QoL). RESULTS: Of the studied cohort 51.4% had moderate persistent, 29.9% mild persistent and 7.2% severe persistent asthma. We found a significant adverse effect of poor inhaler adherence on COVID-19 severity (p=0.049). We also observed a lower hospitalisation rate in patients adequately taking the inhaler with OR of 0.83. Vital capacity and forced expiratory lung volume deterioration caused by COVID-19 were significantly reversed, by approximately twofold to threefold, in individuals who inhaled correctly. CONCLUSION: Higher quality of inhalation technique of corticosteroids measured by adherence to an inhaled medication application technique (A-AppIT) score had a significant positive effect on reversal of the vital capacity and forced expiratory lung volume in 1 s worsening (p=0.027 and p<0.0001, respectively) due to COVID-19. Scoring higher in the A-AppIT was also associated with significantly improved QoL. All measured variables concordantly and without exception showed a positive improvement in response to better adherence. We suggest that corticosteroids provide protection against the worsening of lungs in patients with COVID-19 and that correct and easily assessable adherence to corticosteroids with appropriate inhalation technique play an important role in preventing severe form of COVID-19.


Subject(s)
Asthma , COVID-19 , Humans , Quality of Life , Asthma/drug therapy , Adrenal Cortex Hormones , Forced Expiratory Volume
9.
BMJ Open Respir Res ; 10(1)2023 12 22.
Article in English | MEDLINE | ID: mdl-38135462

ABSTRACT

BACKGROUND: Patients with chronic obstructive pulmonary disease (COPD) may be prescribed multiple inhalers that require different techniques for optimal performance. Mixing devices has been associated with poorer COPD outcomes suggesting that it leads to inappropriate inhaler technique. However, empirical evidence is lacking. AIMS: Compare the nature and frequency of dry powder inhaler (DPI) technique errors in patients with COPD using (1) a single DPI or (2) mixed-devices (a DPI and pressurised metered dose inhaler (pMDI)). METHODS: Data from the PIFotal study-a cross-sectional study on Peak Inspiratory Flow in patients with COPD using a DPI as maintenance therapy, capturing data from 1434 patients on demographic characteristics, COPD health status and inhaler technique-were used to select 291 patients using mixed-devices. Frequency matching based on country of residence and DPI device type was used to select 291 patients using a DPI-only for comparison. Predetermined checklists were used for the evaluation of DPI video recordings and complemented with additional errors that were observed in ≥10%. Error proportions were calculated for the (1) individual and total number of errors, (2) number of critical errors and (3) number of pMDI-related errors. RESULTS: The study sample contained 582 patients (mean (SD) age 69.6 (9.4) years, 47.1% female). DPI technique errors were common, but not significantly different between the groups. The majority of patients made at least one critical error (DPI-only: 90.7% vs mixed-devices: 92.8%). Proportions of total, 'pMDI-related' and critical errors did not significantly differ between the groups. CONCLUSION: The nature and frequency of inhaler technique errors did not substantially differ between patients prescribed with a single DPI and mixed-devices. Currently, 'pMDI-related errors' in DPI use are not accounted for in existing checklists. TRIAL REGISTRATION NUMBER: ENCEPP/EUPAS48776.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Humans , Female , Aged , Male , Cross-Sectional Studies , Metered Dose Inhalers/adverse effects , Administration, Inhalation , Dry Powder Inhalers
10.
BMJ Open Respir Res ; 10(1)2023 09.
Article in English | MEDLINE | ID: mdl-37775111

ABSTRACT

BACKGROUND: Inhaled corticosteroids (ICSs) are associated with an increased risk of pneumonia among patients with chronic obstructive pulmonary disease (COPD). The introduction of extrafine particle ICS has aimed to improve the distribution of medicine in the airways by altering deposition within the lungs, potentially affecting efficacy and side effects. It remains unclear if extrafine particle ICS administration alters the risk of pneumonia compared with standard particle size ICS. METHODS: An observational cohort study including all Danish COPD outpatients receiving ICS from 2010 to 2017. The primary outcome was pneumonia hospitalisation in the different ICS particle dosing regimens. The primary analysis was an adjusted Cox proportional hazards model. For sensitivity analysis, a subgroup analysis of patients receiving spray devices was done. Further, we created a propensity score matched cohort, in which we matched for the same covariates as adjusted for in the main analysis. RESULTS: A total of 35 691 patients were included of whom 1471 received extrafine particle ICS. Among these patients, 4657 were hospitalised due to pneumonia. Patients with COPD receiving extrafine particle ICS had a lower risk of hospitalisation due to pneumonia compared with patients receiving standard particle size ICS in our primary analysis (HR 0.75; 95% CI 0.63 to 0.89; p=0.002), subgroup analysis (HR 0.54; 95% CI 0.45 to 0.65; p<0.0001) and the propensity-matched population (HR 0.72; 95% CI 0.60 to 0.87; p=0.0006). INTERPRETATION: The use of extrafine particle ICS administration was associated with a lower risk of pneumonia hospitalisation in patients with COPD compared with those who received standard size treatment.


Subject(s)
Pneumonia , Pulmonary Disease, Chronic Obstructive , Humans , Cohort Studies , Particle Size , Administration, Inhalation , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/drug therapy , Adrenal Cortex Hormones , Pneumonia/epidemiology , Pneumonia/etiology , Nebulizers and Vaporizers
11.
BMJ Open Respir Res ; 10(1)2023 05.
Article in English | MEDLINE | ID: mdl-37192778

ABSTRACT

BACKGROUND: Asthma remains highly prevalent, with more severe symptoms in low-income to middle-income countries (LMICs) compared with high-income countries. Identifying risk factors for severe asthma symptoms can assist with improving outcomes. We aimed to determine the prevalence, severity and risk factors for asthma in adolescents in an LMIC. METHODS: A cross-sectional survey using the Global Asthma Network written and video questionnaires was conducted in adolescents aged 13 and 14 from randomly selected schools in Durban, South Africa, between May 2019 and June 2021. RESULTS: A total of 3957 adolescents (51.9% female) were included. The prevalence of lifetime, current and severe asthma was 24.6%, 13.7% and 9.1%, respectively. Of those with current and severe asthma symptoms; 38.9% (n=211/543) and 40.7% (n=147/361) had doctor-diagnosed asthma; of these, 72.0% (n=152/211) and 70.7% (n=104/147), respectively, reported using inhaled medication in the last 12 months. Short-acting beta agonists (80.4%) were more commonly used than inhaled corticosteroids (13.7%). Severe asthma was associated with: fee-paying school quintile (adjusted OR (CI)): 1.78 (1.27 to 2.48), overweight (1.60 (1.15 to 2.22)), exposure to traffic pollution (1.42 (1.11 to 1.82)), tobacco smoking (2.06 (1.15 to 3.68)), rhinoconjunctivitis (3.62 (2.80 to 4.67)) and eczema (2.24 (1.59 to 3.14)), all p<0.01. CONCLUSION: Asthma prevalence in this population (13.7%) is higher than the global average (10.4%). Although common, severe asthma symptoms are underdiagnosed and associated with atopy, environmental and lifestyle factors. Equitable access to affordable essential controller inhaled medicines addressing the disproportionate burden of asthma is needed in this setting.


Subject(s)
Asthma , Humans , Female , Adolescent , Male , Prevalence , Cross-Sectional Studies , South Africa/epidemiology , Risk Factors , Asthma/epidemiology , Asthma/etiology , Schools
12.
Patient Prefer Adherence ; 17: 951-959, 2023.
Article in English | MEDLINE | ID: mdl-37038436

ABSTRACT

Background: Inhalation therapy is the cornerstone of treatment of bronchial asthma. A patient-specific selection of inhalation devices is necessary, as preference for a device plays an important role in terms of error rates in handling and adherence to therapy. However, there is no industry-independent study providing information on children's preferences for common inhaler types. The aim of the present study was to investigate the preference of asthmatic children for inhaler types commonly used in Germany. The effects of age, gender and the type of school visited on device preferences as well as the frequency of patient education and the role of health care providers in the choice for an inhaler were investigated. Methods: Eighty children were included in this prospective cross-sectional study (age: 10.87 ± 2.62 years). The analysis was based on a questionnaire and validated checklists. All participants tested the use of nine placebo inhalers (Breezhaler, Diskus, Respimat, Spiromax, Turbohaler, Autohaler, metered-dose inhaler, Easyhaler and Novolizer) in a randomized order. For each device, patients were asked to assess handling, rate different device characteristics and name the device they would prefer most or least. Results: The most favored device was the Novolizer. Moreover, the Spiromax scored highest in numerous categories such as suitability in emergencies and "easiest" device to use. Patient preferences with respect to the addressed inhaler features were not significantly related to age, gender or school type. Conclusion: The Novolizer and the Spiromax showed higher preference in pediatric patients as compared to other tested devices. Overall, there were significant differences in terms of preference when comparing the tested inhalers in different aspects.

13.
Front Pharmacol ; 14: 1152069, 2023.
Article in English | MEDLINE | ID: mdl-37089917

ABSTRACT

Objective: To understand the level of knowledge about inhaler devices among medical staff. Methods: This study evaluated the knowledge of inhalation therapy and the use of inhaler devices among nurses in China. We administered a new self-designed online questionnaire to 1,831 nurses. The questionnaire comprised 11 questions, including the storage location of inhaler devices, steps involved in using inhaler devices, and common errors when using various devices. Results: Among the 1,831 participants, 816(44.57%), 122(6.66%), and 893(48.77%) nurses worked in community, secondary, and tertiary hospitals, respectively. Adequate knowledge of inhaler devices was demonstrated by 20.10%, 8.20%, and 13.10% of nurses working in community, secondary, and tertiary hospitals, respectively. Of the nurses working in community hospitals, 27.70% knew the key points for using inhalers compared to 15.57% in secondary hospitals and 23.18% in tertiary hospitals (p < 0.01). Only 9.50%-26.00% of participants chose correct answers to the 9 questions about the use of inhalers. The accuracy rate of the responses was generally low, and the highest accuracy rate was 26.00%. Conclusion: Knowledge of inhalation therapy was better among nurses working in community hospitals than among those working in high-level hospitals. This is because of the clearer division of work and higher workload in high-level hospitals. Overall, nurses' knowledge of inhalation therapy is low. Furthermore, knowledge about inhaler devices should be strengthened among nurses in Chinese hospitals. It is necessary to create training opportunities for nurses in China to increase their awareness and knowledge regarding the management of chronic respiratory diseases.

14.
BMJ Open Respir Res ; 10(1)2023 03.
Article in English | MEDLINE | ID: mdl-36878611

ABSTRACT

BACKGROUND: Aboriginal Australians are reported to have a high burden of chronic airway diseases. However, prescribing patterns and related outcomes of airway directed inhaled pharmacotherapy, (short-acting beta agonists (SABA), short-acting muscarinic antagonists (SAMA), long-acting ß-agonists (LABA), long-acting muscarinic antagonists (LAMA) and inhaled corticosteroids (ICS)) among Aboriginal Australian patients with chronic airway disease have been sparsely reported in the past. METHODS: A retrospective cohort study was conducted, using clinical, spirometry data, chest radiology, primary healthcare (PHC) presentations and hospital admission rates among Aboriginal patients identified to have been prescribed inhaled pharmacotherapy in remote and rural communities referred to the respiratory specialist service in the Top End, Northern Territory of Australia. RESULTS: Of the 372 identified active patients, 346 (93%) had inhaled pharmacotherapy prescribed (64% female, median age 57.7 years). ICS was the most common prescription (72% of the total cohort) and was recorded to be prescribed in 76% of patients with bronchiectasis, and 80% of patients with asthma or chronic obstructive pulmonary disease (COPD). Fifty-eight percent of patients had a respiratory hospital admission and 57% had a recorded PHC presentation for a respiratory issue during the study period, with a higher rate of hospital admissions among patients prescribed ICS compared with those on SAMA/SABA or LAMA/LABA without ICS (median rate (per person per year) 0.42 vs 0.21 and 0.21 (p=0.004). Regression models demonstrated that presence of COPD or bronchiectasis alongside ICS was associated with significantly increased hospitalisation rates (1.01 admissions/person/year (95% CI 0.15 to 1.87) and 0.71 admissions/person/year (95% CI 0.23 to 1.18) against patients without COPD/bronchiectasis, respectively). CONCLUSIONS: This study demonstrates that among Aboriginal patients with chronic airway diseases, ICS is the most common inhaled pharmacotherapy prescribed. Although LAMA/LABA and concurrent ICS use may be appropriate among patients with asthma and COPD, the use of ICS may have detrimental effects among those with underlying bronchiectasis either in isolation or concurrent COPD and bronchiectasis, potentially leading to higher hospital admission rates.


Subject(s)
Asthma , Bronchiectasis , Pulmonary Disease, Chronic Obstructive , Humans , Female , Middle Aged , Male , Northern Territory/epidemiology , Australian Aboriginal and Torres Strait Islander Peoples , Muscarinic Antagonists/therapeutic use , Retrospective Studies , Pulmonary Disease, Chronic Obstructive/drug therapy
15.
J Investig Allergol Clin Immunol ; 33(4): 250-262, 2023 Jul 27.
Article in English | MEDLINE | ID: mdl-36648318

ABSTRACT

BACKGROUND: Pressurized metered-dose inhalers (pMDIs) exert an environmental impact resulting from CO2 emissions. Therapeutic alternatives with less environmental impact are widely used. Nevertheless, the choice of device and appropriate therapy should meet the clinical needs and the characteristics of the patient. OBJECTIVE: The primary objective was to estimate the impact of pMDIs prescribed for any indication on annual CO2 emissions in Spain.The secondary objective was to evaluate the potential impact of switching pMDIs to dry-powder inhalers (DPIs) in patients with asthma. METHODS: A systematic review of the evidence published during 2010-2021 was carried out. Average annual CO2 emissions of DPIs and pMDIs were calculated in 2 scenarios: the current situation and a hypothetical situation involving a switch from all pMDIs to DPIs. The impact of the switch on clinical outcomes was also evaluated. RESULTS: The total value of CO2-eq/year due to DPIs and pMDIs accounted for 0.0056% and 0.0909%, respectively, of total emissions in Spain. In the event of switching pMDIs to DPIs, except those used for rescue medication, the percentages were 0.0076% and 0.0579%. The evaluation of efficacy, handling, satisfaction, safety, and use of health care resources was not conclusive. CONCLUSIONS: Current CO2 emissions by pMDIs account for a small percentage of the total CO2 footprint in Spain. Nevertheless, there is a need for research into new and more sustainable devices. Suitability and patient clinical criteria such as age and inspiratory flow should be prioritized when prescribing an inhaler.


Subject(s)
Asthma , Carbon Footprint , Humans , Spain/epidemiology , Carbon Dioxide/therapeutic use , Asthma/drug therapy , Dry Powder Inhalers , Administration, Inhalation
16.
BMJ Open Respir Res ; 9(1)2022 12.
Article in English | MEDLINE | ID: mdl-36522130

ABSTRACT

INTRODUCTION: Suboptimal asthma control is associated with incorrect inhaler use and poor medication adherence, which could lead to unfavourable clinical and economic outcomes. Smart inhaler programmes using electronic monitoring devices (EMDs) could support self-management and increase medication adherence and asthma control. However, evidence on long-term benefits and acceptability is scarce. This study aims to investigate the effectiveness of a smart inhaler asthma self-management programme on medication adherence and clinical outcomes in adults with uncontrolled asthma, to evaluate its acceptability and to identify subgroups who would benefit most based on patient characteristics. METHODS AND ANALYSIS: This open-label cluster randomised controlled trial of 12 months will be conducted in primary care in the Netherlands. General practices will be randomly assigned to either intervention or control group. We aim to include 242 patients. The intervention consists of (1) an EMD attached to the patient's inhaler that measures medication use; (2) a smartphone application to set medication reminders, receive motivational messages and track asthma symptoms; and (3) a portal for healthcare professionals to view data on medication use. The control group is passively monitored by the EMD but cannot view their inhaler data or receive feedback. Eligible patients are adults with suboptimal controlled asthma (Asthma Control Questionnaire score ≥0.75) with evidence of non-adherence established by the EMD during a 6-week run-in period. Primary outcome is the difference in mean medication adherence between intervention and control group. Secondary outcomes include asthma control, asthma-related quality of life, exacerbations, acceptance, cost-effectiveness and whether the effect of the intervention on medication adherence and asthma control is modified by patient characteristics (eg, self-efficacy, medication beliefs and eHealth literacy).Trial registration numberNL7854.


Subject(s)
Asthma , Mobile Applications , Adult , Humans , Quality of Life , Nebulizers and Vaporizers , Asthma/drug therapy , Asthma/diagnosis , Medication Adherence , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
17.
BMJ Open Respir Res ; 9(1)2022 09.
Article in English | MEDLINE | ID: mdl-36171051

ABSTRACT

INTRODUCTION: Treatment pathways of patients with chronic obstructive pulmonary disease (COPD) receiving single-device dual therapies in England remain unclear. This study describes the characteristics of patients with COPD before initiating treatment with a single-device inhaled corticosteroid/long-acting ß2-agonist (ICS/LABA) in primary care in England. METHODS: This is a retrospective, descriptive study of linked primary and secondary healthcare data (Clinical Practice Research Datalink Aurum, Hospital Episode Statistics). Patients with COPD were indexed on first prescription of fixed-dose, single-device ICS/LABA (June 2015-December 2018). Demographics, clinical characteristics, prescribed treatments, healthcare resource use (HCRU) and direct healthcare costs were assessed over 12 months pre-index. Incident users (indexed on first ever prescription) could be non-triple users (no concomitant long-acting muscarinic antagonist at index); a subset were initial maintenance therapy (IMT) users (no history of pre-index maintenance therapy). RESULTS: Overall, 13 451 incident users (non-triple users: 7448, 55.4%; IMT users: 5162, 38.4%) were indexed on beclomethasone dipropionate/formoterol (6122, 45.5%), budesonide/formoterol (2703, 20.1%) or Other ICS/LABA combinations (4626, 34.4%). Overall, 20.8% of incident users had comorbid asthma and 42.6% had ≥1 moderate-to-severe acute exacerbation of COPD pre-index. Baseline characteristics were similar across indexed therapies. At 3 months pre-index, 45.3% and 35.4% of non-triple and IMT users were receiving maintenance treatment. HCRU and direct healthcare costs were similar across indexed treatments. Prescribing patterns varied regionally. CONCLUSION: Patient characteristics, prior treatments, prior COPD-related HCRU and direct healthcare costs were similar across single-device ICS/LABAs in primary care in England. A high proportion of patients were not receiving any respiratory medication pre-index, indicating that prescribing in primary care in England is more closely aligned with national guidelines than global treatment strategies. Comorbid asthma may have influenced prescribing decisions. Less than half of users had preindex exacerbations, suggesting that ICS/LABA is not being prescribed principally based on exacerbation history.


Subject(s)
Asthma , Pulmonary Disease, Chronic Obstructive , Administration, Inhalation , Adrenal Cortex Hormones , Adrenergic beta-2 Receptor Agonists/adverse effects , Asthma/drug therapy , Beclomethasone/therapeutic use , Budesonide, Formoterol Fumarate Drug Combination/therapeutic use , Formoterol Fumarate/therapeutic use , Humans , Muscarinic Antagonists/therapeutic use , Primary Health Care , Pulmonary Disease, Chronic Obstructive/drug therapy , Retrospective Studies
18.
BMJ Open Respir Res ; 9(1)2022 08.
Article in English | MEDLINE | ID: mdl-36007980

ABSTRACT

BACKGROUND: In randomised controlled trials, as-needed inhaled corticosteroid (ICS)-formoterol reliever therapy reduces severe exacerbation risk compared with maintenance ICS plus short-acting beta2-agonist (SABA) reliever in adolescent and adult asthma, but results in slightly worse control of asthma symptoms, as measured by mean Asthma Control Questionnaire-5 (ACQ-5) score. OBJECTIVE: To assess the levels and changes in asthma control for as-needed budesonide-formoterol versus maintenance budesonide plus SABA in post hoc analyses from the Novel START and PRACTICAL clinical trials. METHODS: The number and proportion of participants at study end in each ACQ-5 category ('well-controlled', 'partly controlled' or 'inadequately controlled' symptoms), and in each responder category based on the minimal clinically important difference for ACQ-5 of 0.5 (improved, no change and worse) with as-needed budesonide-formoterol and maintenance budesonide plus SABA treatment were calculated. RESULTS: With last observation carried forwards, 189/214 (88.3%) and 354/434 (81.6%) of patients in the budesonide-formoterol group had 'well-controlled' or 'partly controlled' symptoms at the end of the study, vs 183/214 (85.5%) and 358/431 (83.1%) in the budesonide maintenance group, for Novel START and PRACTICAL, respectively. The proportion of patients whose symptom control was either improved or unchanged from baseline was 190/214 (88.8%) and 368/434 (84.8%) for budesonide-formoterol, vs 185/214 (86.4%) and 376/431 (87.2%) for maintenance budesonide, in Novel START and PRACTICAL respectively. CONCLUSIONS: There were no clinically important differences in the proportions of patients with 'well-controlled' or 'partly controlled' asthma symptoms, or proportions who improved or maintained their level of control, with as-needed budesonide-formoterol versus maintenance budesonide plus SABA.


Subject(s)
Anti-Asthmatic Agents , Asthma , Adolescent , Adult , Humans , Adrenal Cortex Hormones/therapeutic use , Anti-Asthmatic Agents/therapeutic use , Asthma/drug therapy , Bronchodilator Agents , Budesonide/therapeutic use , Budesonide, Formoterol Fumarate Drug Combination/therapeutic use , Ethanolamines/therapeutic use , Formoterol Fumarate/therapeutic use , Randomized Controlled Trials as Topic
19.
Thorax ; 77(10): 1045-1047, 2022 10.
Article in English | MEDLINE | ID: mdl-35970539

ABSTRACT

The 2021 purchase of the respiratory pharmaceutical company Vectura by Phillip Morris International has been criticised by the public health and medical community, as a conflict of interest, with little input to date, from the patient community or the public. To address this gap, the COPD Foundation, along with global partners, surveyed 1196 people with chronic respiratory disease. 70% were bothered by a tobacco company making an inhaler to treat lung conditions and 48% reported that they would want to switch inhalers if they knew that a tobacco company made or sold their inhaler devices. Patients care about who makes the therapies used to treat their diseases.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Respiration Disorders , Respiratory Tract Diseases , Tobacco Industry , Humans , Ownership , Pulmonary Disease, Chronic Obstructive/drug therapy , Nebulizers and Vaporizers , Respiratory Tract Diseases/drug therapy , Pharmaceutical Preparations , Administration, Inhalation
20.
Thorax ; 2022 Jul 18.
Article in English | MEDLINE | ID: mdl-35851045

ABSTRACT

OBJECTIVE: To compare bronchodilator response after to salbutamol and budesonide/formoterol in adults with stable asthma. METHODS: A double-blind, cross-over, single-centre, placebo-controlled, non-inferiority trial. Adults with stable asthma were randomised to different orders of two treatment regimens: two actuations of placebo via MDI and one actuation of budesonide/formoterol 200/6 µg via turbuhaler; and one actuation of placebo turbuhaler and two actuations of salbutamol 100 µg via MDI. The primary outcome measure was FEV1 after 2 min. Secondary outcome measures included FEV1, mBorg Dyspnoea Scale score and visual analogue score for breathlessness over 30 min. RESULTS: Forty-nine of 50 potential participants were randomised. One participant withdrew following the first intervention visit and another could not be randomised due to COVID-19 restrictions. The mean (SD) change from baseline FEV1 2 min after treatment administration for budesonide/formoterol and salbutamol was 0.08 (0.14) L, n=49, and 0.17 (0.18) L, n=48, respectively, mean (95% CI) paired difference of -0.097 L (-0.147 to -0.047), p=0.07, against a non-inferiority bound of -0.06 L. In the secondary analysis, FEV1 over 30 min was lower for budesonide/formoterol compared with salbutamol, difference (95% CI): -0.10 (-0.12 to -0.08) L, p<0.001. There were no differences in Visual Analogue Scale score or mBorg Dyspnoea Scale score between treatments. CONCLUSION: The results do not support the primary hypothesis of non-inferiority at the boundary of -0.06 L for the difference between budesonide/formoterol 200/6 µg compared with salbutamol 200 µg for FEV1 at 2 min, and could be consistent with inferiority with a p value of 0.07. For the secondary analysis of FEV1 measurements over time, the FEV1 was higher with salbutamol. TRIAL REGISTRATION NUMBER: Australian and New Zealand Clinical Trials Registry (ACTRN 12619001387112).