Eur J Med Res ; 29(1): 281, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735983

ABSTRACT

The base excess value (BE, mmol/L), not standard base excess (SBE), correctly calculated including pH, pCO2 (mmHg), sO2 (%) and cHb (g/dl) is a diagnostic tool for several in vivo events, e.g., mortality after multiple trauma or shock, acidosis, bleeding, clotting, artificial ventilation. In everyday clinical practice a few microlitres of blood (arterial, mixed venous or venous) are sufficient for optimal diagnostics of any metabolic acidosis or alkalosis.The same applies to a therapeutic tool-then referred to as potential base excess (BEpot)-for several in vitro assessments, e.g., solutions for infusion, sodium bicarbonate, blood products, packed red blood cells, plasma. Thus, BE or BEpot has been a parameter with exceptional clinical significance since 2007.


Subject(s)
Acidosis , Humans , Acidosis/diagnosis , Acidosis/blood , Acid-Base Imbalance/diagnosis , Acid-Base Imbalance/therapy , Acid-Base Equilibrium/physiology , Alkalosis/diagnosis , Alkalosis/blood