Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 174
Filter
1.
JACC Case Rep ; 29(18): 102524, 2024 Sep 18.
Article in English | MEDLINE | ID: mdl-39359973

ABSTRACT

We present a case of cardioembolic stroke in a patient with a history of mechanical aortic valve who was compliant with anticoagulation medication. Cardiac computed tomography was used as an alternative, noninvasive means of evaluation for the cardioembolic source of stroke and identified subvalvular mobile pannus of the mechanical aortic valve.

2.
J Clin Med ; 13(19)2024 Sep 25.
Article in English | MEDLINE | ID: mdl-39407772

ABSTRACT

Objectives: This study aimed to compare the clinical outcomes of mechanical and biological valve prostheses in patients with infective endocarditis presenting with stroke. Methods: Ninety-five adults with infective endocarditis complicated by stroke at baseline who underwent aortic and/or mitral valve replacement were analyzed retrospectively. The primary outcome was a composite outcome of all-cause mortality, ischemic stroke, hemorrhagic stroke, and re-endocarditis. Secondary outcomes included the individual components of the composite outcome and modified Rankin scale deterioration during follow-up. Results: Among the study cohort, 34 patients (35.8%) received mechanical valve prostheses and 61 (64.2%) received biological valve prostheses. Implantation of a mechanical valve prosthesis seems to be associated with a decreased risk of attaining the composite outcome (adjusted HR 0.46, 95% CI 0.22-0.96, and p = 0.037). Analyses of the individual components of the composite outcome showed that implantation of a mechanical valve prosthesis might not be associated with an increased risk of ischemic stroke, hemorrhagic stroke, and all-cause mortality during the follow-up period. Further, the risk of re-endocarditis was significantly lower in recipients of a mechanical valve prosthesis (adjusted HR 0.15, 95% CI 0.06-0.77, p = 0.026). Notably, a trend toward decreased risk of modified Rankin scale deterioration throughout the follow-up period was observed in this group (adjusted odds ratio 0.22, 95% CI 0.05-1.02, p = 0.053). Conclusions: Implantation of mechanical valve prostheses in patients presenting with infective endocarditis complicated by stroke seems to be beneficial in terms of a reduced risk of experiencing a composite outcome. Analyses of larger cohorts are required to validate our findings.

3.
Diseases ; 12(8)2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39195190

ABSTRACT

BACKGROUND: The timing of treatment for chronic aortic valve regurgitation (AR), especially in asymptomatic patients, is gaining attention since less invasive strategies have become available. The aim of the present study was to evaluate left ventricular reverse remodeling after aortic valve replacement (AVR) for severe AR. METHODS: Patients (n = 25) who underwent surgical AVR for severe AR with left ventricular ejection fraction (LVEF) less than 55% were included in this study. Preprocedural and follow-up clinical and echocardiographic measurements of LVEF and left ventricular (LV) diameters were retrospectively analyzed. RESULTS: Mean LVEF increased significantly following surgical AVR (p < 0.0001). LV diameters showed a clear regression (p = 0.0088). Younger patients and those receiving a mechanical valve tended to have less improved LVEF on follow-up than patients over 60 years or the ones who were implanted with a biological prosthesis (p = 0.0239 and p = 0.069, respectively). Gender had no effect on the degree of LVEF improvement (p = 0.4908). CONCLUSIONS: We demonstrated significant LV reverse remodeling following AVR for AR. However, more data are needed on LV functional and geometrical improvement comparing the different types of valve prostheses to provide an optimal treatment strategy.

5.
J Clin Med ; 13(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38999334

ABSTRACT

The mechanical valve was first invented in the 1950s, and since then, a wide variety of prostheses have been developed. Although mechanical valves have outstanding durability, their use necessitates life-long treatment with anticoagulants, which increases the risk of bleeding and thromboembolic events. The current guidelines recommend a mechanical prosthetic valve in patients under 50-60 years; however, for patients aged 50-70 years, the data are conflicting and there is not a clear-cut recommendation. In recent decades, progress has been made in several areas. First, the On-X mechanical valve was introduced; this valve has a lower anticoagulant requirement in the aortic position. Second, a potential alternative to vitamin K-antagonist treatment, rivaroxaban, has shown encouraging results in small-scale trials and is currently being tested in a large randomized clinical trial. Lastly, an innovative mechanical valve that eliminates the need for anticoagulant therapy is under development. We attempted to review the current literature on the subject with special emphasis on the role of mechanical valves in the current era and discuss alternatives and future innovations.

6.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38936344

ABSTRACT

OBJECTIVES: Prothesis choice in isolated mitral valve replacement for patients aged 75 years or younger remains debated as most studies comparing prothesis type have included large proportions of combined operations and benefits are influenced by concomitant procedures. This study compared long-term outcomes of isolated mechanical versus bioprosthetic mitral valves in different age groups of propensity-matched populations. METHODS: This is a retrospective, multicentre, propensity-matched observational study. Baseline characteristics, operative details and long-term outcomes (mortality and freedom from surgical/transcatheter reintervention) were collected. RESULTS: Totally, 1536 isolated mitral valve replacements (806 mechanical, 730 bioprosthetic) were performed between 2000 and 2017. Over 90% of eligible patients successfully underwent propensity matching, yielding 226 each of mechanical and bioprosthetic valves in patients aged <65 years and 171 each of bioprosthetic and mechanical valves in patients aged 65-75 years with median follow-up of 13 years (maximum 20 years). In matched patients <65 years, 10-year survival was superior with mechanical valves versus bioprosthetic valves (78.2% vs 69.8%, P = 0.029), as was 10-year freedom from reintervention (96.2% vs 81.3%, P < 0.001). For matched patients between 65 and 75 years, there were no differences between mechanical and bioprosthetic valves in 10-year survival (64.6% vs 60.8%, P = 0.86) or 10-year freedom from reintervention (94.0% vs 97.2%, P = 0.23). Rates of post-operative stroke, gastrointestinal bleeding, renal failure and permanent pacemaker insertion were similar. CONCLUSIONS: In patients requiring isolated mitral valve replacement, mechanical valves confer significantly better long-term survival and freedom from reintervention for patients <65 years, while no benefit is observed at age 65-75 years compared to bioprosthetic valves.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Propensity Score , Humans , Aged , Male , Female , Retrospective Studies , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Middle Aged , Age Factors , Treatment Outcome , Prosthesis Design , Heart Valve Diseases/surgery , Postoperative Complications/epidemiology
7.
J Chest Surg ; 57(5): 496-499, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-38835208

ABSTRACT

Calcification of the mitral valve annulus is common in patients on dialysis. The growing number of individuals receiving dialysis has been accompanied by an increase in cases necessitating surgical intervention for mitral valve annulus calcification. In this report, we present a severe case characterized by bulky calcification of the mitral annulus, which was managed with mechanical mitral valve replacement. A 61-year-old man on dialysis presented with chest pain upon exertion that had persisted for 3 months. Cardiac echocardiography revealed severe mitral stenosis and regurgitation, accompanied by cardiac dysfunction. During surgery, an ultrasonic aspiration system was employed to remove the calcification of the mitral valve annulus to the necessary extent. Subsequently, a mechanical mitral valve was sutured into the supra-annular position. To address the regurgitation, the area surrounding the valve was sewn to the wall of the left atrium. Postoperative assessments indicated an absence of perivalvular leak and demonstrated improved cardiac function. The patient was discharged on postoperative day 22. We describe a successful mitral mechanical valve replacement in a case of extensive circumferential mitral annular calcification. Even with severe calcification extending into the left ventricular myocardium, we were able to minimize the decalcification process. This approach enabled the performance of mitral mechanical valve replacement in a high-risk patient on dialysis, thus expanding the possibilities for cardiac surgery.

8.
Curr Cardiol Rep ; 26(7): 747-755, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38789693

ABSTRACT

PURPOSE OF REVIEW: Dysfunction and thrombosis of mechanical heart valves, although uncommon, represents a challenge that requires multidisciplinary expertise for diagnosis and management. The aim of this review is to summarize strengths and weaknesses of diagnostic methods and therapeutic strategies for this uncommon but potentially life-threatening pathology. RECENT FINDINGS: Expeditious diagnosis of mechanical valve thrombosis and exclusion of other diagnostic considerations, often with incorporation of multimodality imaging, can inform the best treatment strategy. Presentation of mechanical valve thrombosis can be asymptomatic or can include heart failure, life-threatening embolic events, or cardiogenic shock. Echocardiography, fluoroscopy and computed tomography are important in the evaluation of mechanical valve dysfunction. Therapeutic strategies for thrombosis include anticoagulation, systemic thrombolysis, and surgery. Choice of treatment depends on multiple factors including thrombus size, degree of valve dysfunction, clinical presentation, and available surgical expertise.


Subject(s)
Heart Valve Prosthesis , Thrombosis , Humans , Thrombosis/etiology , Thrombosis/diagnostic imaging , Thrombosis/therapy , Thrombosis/physiopathology , Thrombolytic Therapy/methods , Anticoagulants/therapeutic use , Echocardiography , Heart Valve Diseases/therapy , Heart Valve Diseases/physiopathology , Prosthesis Failure , Tomography, X-Ray Computed
9.
Eur Heart J Case Rep ; 8(5): ytae194, 2024 May.
Article in English | MEDLINE | ID: mdl-38707525

ABSTRACT

Background: Complex atrial tachycardia (AT) is commonly observed in patients with cardiac surgery. High-density mapping is widely adopted for catheter ablation of complex AT in patients with cardiac surgery. Several case reports have described that PentaRay mapping catheter can be trapped in the mechanical valve and sheared off and successful retrieval of the spline by a snare system. We described a rare case in which PentaRay mapping catheter spline was successfully retrieved from the distal anterior tibial artery by direct syringe suction via the diagnostic catheter following entrapment in the mechanical mitral valve (MV) and rupture of the spline. Case summary: A 70-year-old female with mechanical bileaflet MV underwent catheter ablation for AT. During mapping in left atrium, the catheter was entrapped in mechanical MV and sheared off. We attempted to release the entrapped the spline by advancing the ablation catheter towards the stuck disc and pushing on the hinge portion of the disc with the catheter tip. The stuck and closed disc was opened, and the deeply entrapped spline was released. However, the entrapped PentaRay spline floated through the Valsalva sinus and strayed into the distal left anterior tibial artery. Fortunately, we successfully retrieved the spline from the distal anterior tibial artery by direct syringe suction instead of a snare system. Discussion: The possibility of the entrapment and subsequent rupture of the spline should always be considered during mapping the site close to mechanical valve. A rapid retrieval of embolized material should be carried out. If the spline strays into the distal and small artery in which the snare system is difficult to advance, a direct syringe suction via the diagnostic catheter may be attempted.

10.
J Cardiothorac Surg ; 19(1): 279, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715032

ABSTRACT

OBJECTIVE: Reports on long-term outcomes of surgical aortic valve replacement (AVR) for patients aged < 60 years are scarce in Japan. Hence, we aimed to evaluate these outcomes in patients aged < 60 years. METHODS: Between March 2000 and December 2020, 1477 patients underwent aortic valve replacement. In total, 170 patients aged < 60 years who underwent aortic valve replacement were recruited. Patients aged < 18 years were excluded. Patient data collected from the operative records and follow-up assessments were reviewed. RESULTS: The mean age was 49 ± 9 years, and 64.1% of patients were male. One-hundred-and-fifty-two patients (89.4%) underwent aortic valve replacement with a mechanical valve and 18 (10.6%) with a bioprosthetic valve. The mean follow-up period was 8.1 ± 5.5 years. No operative mortality occurred, and in-hospital mortality occurred in one patient (0.6%). Ten late deaths occurred, with seven cardiac-related deaths. The overall survival rate was 95.4 ± 1.7%, 93.9 ± 2.3%, 90.6 ± 3.9%, and 73.2 ± 11.8% at 5, 10, 15, and 20 years, respectively. Freedom from major bleeding was 96.4 ± 1.6% at 5, 10, and 15 years, and 89.0 ± 7.3% at 20 years. Freedom from thromboembolic events was 98.7 ± 1.3%, 97.3 ± 1.9%, 90.5 ± 4.5%, and 79.0 ± 11.3% at 5, 10, 15, and 20 years, respectively. Freedom from valve-related reoperation was 99.4 ± 0.6% at 5 years, 97.8 ± 1.7% at 10 and 15 years, and 63.9 ± 14.5% at 20 years. CONCLUSIONS: Patients aged < 60 years undergoing aortic valve replacement with a high mechanical valve implantation rate had favorable long-term outcomes.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Male , Middle Aged , Female , Heart Valve Prosthesis Implantation/methods , Aortic Valve/surgery , Adult , Bioprosthesis , Retrospective Studies , Postoperative Complications/epidemiology , Japan/epidemiology , Follow-Up Studies , Treatment Outcome , Survival Rate/trends , Age Factors , Time Factors , Hospital Mortality
11.
Int Med Case Rep J ; 17: 465-470, 2024.
Article in English | MEDLINE | ID: mdl-38770519

ABSTRACT

This report reviews an Ethiopian patient who underwent cardiac surgery and had a mechanical heart valve implanted on the mitral valve with tricuspid valve repair for rheumatic heart disease via a local non-profit organization donation later complicated by cardio-embolic stroke, and aims to describe the challenges faced by patients from rural Ethiopia who require cardiac surgery for rheumatic heart disease and narrate the importance of careful follow-up. The lessons to be drawn from this case are that careful follow-up and adherence to prescribed Vitamin K antagonists after surgery for mechanical heart valves are critical and, when such patients are lost to follow-up as was witnessed in this case, it can induce lifelong morbidity. Morbidity that could have been avoided with strict and meticulous follow-up and with standardized patient tracing or contact systems. When patients are lost to follow-up it needs to be top priority to trace them after cardiac surgery and this report highlights the pivotal role of the health education in such populations. Unless we utilize this opportunity to unlock the door and embrace a systemic approach to reforming our risk assessment, referral chain system, and integration of various healthcare professionals in patient follow-up, as well as enhancing health education among our patients in rural Ethiopia and other low-income countries, the consequences could prove to be significant. Preventing such fatal complications is far superior to managing them afterwards, as it not only saves on expenses but also saves lives and enhances quality-of-life.

12.
Artif Organs ; 48(9): 977-987, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38651352

ABSTRACT

BACKGROUND: In vitro assessment is mandatory for artificial heart valve development. This study aims to investigate the effects of pulse duplicator features on valve responsiveness, conduct a sensitivity analysis across valve prosthesis types, and contribute on the development of versatile pulse duplicator systems able to perform reliable prosthetic aortic valve assessment under physiologic hemodynamic conditions. METHODS: A reference pulse duplicator was established based on literature. Further optimization process led to new designs that underwent a parametric study, also involving different aortic valve prostheses. These designs were evaluated on criteria such as mean pressure differential and pulse pressure (assessed from high-fidelity pressure measurements), valve opening and closing behavior, flow, and regurgitation. Finally, the resulting optimized setup was tested under five different hemodynamic settings simulating a range of physiologic and pathologic conditions. RESULTS: The results show that both, pulse duplicator design and valve type significantly influence aortic and ventricular pressure, flow, and valve kinematic response. The optimal design comprised key features such as a compliance chamber and restrictor for diastolic pressure maintenance and narrow pulse pressure. Additionally, an atrial reservoir was included to prevent atrial-aortic interference, and a bioprosthetic valve was used in mitral position to avoid delayed valve closing effects. CONCLUSION: This study showed that individual pulse duplicator features can have a significant effect on valve's responsiveness. The optimized versatile pulse duplicator replicated physiologic and pathologic aortic valve hemodynamic conditions, serving as a reliable characterization tool for assessing and optimizing aortic valve performance.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Humans , Aortic Valve/surgery , Models, Cardiovascular , Bioprosthesis
13.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38478403
14.
Article in English | MEDLINE | ID: mdl-38522873

ABSTRACT

When the options of aortic valve repair or the Ross procedure are not feasible or have been exhausted, mechanical aortic valve replacement (AVR) may provide a reliable and structurally durable alternative, but with the limitations of long-term anticoagulation, thrombosis risk and lack of valve growth potential. In this article, we review the longitudinal outcomes of mechanical AVR in children in our institution and compare them to those recently reported by others. From 1978 to 2020, 62 patients underwent mechanical AVR at a median age of 12.4 years (interquartile range (IQR): 8.6-16.8 years). The most common underlying diagnoses were: conotruncal anomalies (40%, 25/62), congenital aortic stenosis (16%, 10/62), rheumatic valve disease (16%, 10/62), connective tissue disease (8.1%, 5/62) and infective endocarditis (6.5%, 4/62). Thirty-two patients (52%, 32/62) had at least 1 prior aortic valve surgery prior to mechanical AVR. Early death was 3.2% (2/62). Median follow-up was 14.4 years (IQR: 8.4-28.2 years). Kaplan-Meier survival was 96.8%, 91.9%, 86.3%, and 81.9% at 1, 5, 10, and 20 years. On competing risk analysis, the proportion of patients alive without aortic valve reoperation at 1, 5, 10, and 20 years was 95.2%, 87.0%, 75.5% and 55.4%, respectively, while the proportion of patients that had aortic valve reoperation (with death as a competing event) at 1, 5, 10, and 20 years was 1.6%, 4.9%, 12.8%, and 28.5%, respectively. In conclusion, when the options of aortic valve repair or the Ross procedure are not feasible in children, mechanical AVR is an alternative, yet the long-term rates of mortality and need for aortic valve reoperation are of concern.


Subject(s)
Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Child , Humans , Aortic Valve/surgery , Treatment Outcome , Retrospective Studies , Heart Valve Diseases/surgery , Reoperation
15.
J Chest Surg ; 57(3): 242-251, 2024 May 05.
Article in English | MEDLINE | ID: mdl-38472122

ABSTRACT

Background: This study compared the outcomes of surgical aortic valve replacement (AVR) in patients aged 50 to 70 years based on the type of prosthetic valve used. Methods: We compared patients who underwent mechanical AVR to those who underwent bioprosthetic AVR at our institution between January 2000 and March 2019. Competing risk analysis and the inverse probability of treatment weighting (IPTW) method based on propensity score were employed for comparisons. Results: A total of 1,580 patients (984 patients with mechanical AVR; 596 patients with bioprosthetic AVR) were enrolled. There was no significant difference in early mortality between the mechanical AVR and bioprosthetic AVR groups (0.9% vs. 1.7%, p=0.177). After IPTW adjustment, the risk of all-cause mortality was significantly higher in the bioprosthetic AVR group than in the mechanical AVR group (hazard ratio [HR], 1.39; 95% confidence interval [CI], 1.07-1.80; p=0.014). Competing risk analysis revealed lower risks of stroke (sub-distributional hazard ratio [sHR], 0.44; 95% CI, 0.28-0.67; p<0.001) and anticoagulation- related bleeding (sHR, 0.35; 95% CI, 0.23-0.53; p<0.001) in the bioprosthetic AVR group. Conversely, the risk of aortic valve (AV) reintervention was higher in the bioprosthetic AVR group (sHR, 6.14; 95% CI, 3.17-11.93; p<0.001). Conclusion: Among patients aged 50 to 70 years who underwent surgical AVR, those receiving mechanical valves showed better survival than those with bioprosthetic valves. The mechanical AVR group exhibited a higher risk of stroke and anticoagulation-related bleeding, while the bioprosthetic AVR group showed a higher risk of AV reintervention.

16.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38305431

ABSTRACT

OBJECTIVES: This nationwide retrospective cohort study assessed the impact of the explanted valve type on reoperative outcomes in aortic valve surgery within the UK over a 23-year period. METHODS: Data were sourced from the National Institute for Cardiovascular Outcomes Research (NICOR) database. All patients undergoing first-time isolated reoperative aortic valve replacement between 1996 and 2019 in the UK were included. Concomitant procedures, homograft implantation or aortic root enlargement were excluded. Propensity score matching was utilized to compare outcomes and risk factors for in-hospital mortality was evaluated through multivariable logistic regression. Final model selection was conducted using Akaike Information Criterion through bootstrapping. The primary end point was in-hospital mortality, and secondary end points included postoperative morbidities. RESULTS: Out of 2371 patients, 24.9% had mechanical and 75% had bioprosthetic valves implanted during the primary procedure. Propensity matched groups of 324 patients each, were compared. In-hospital mortality for mechanical and bioprosthetic valve explants was 7.1% and 5.9%, respectively (P = 0.632). On multivariable logistic regression analysis, valve type was not a risk factor for mortality [odds ratio (OR) 0.62, 95% confidence interval (CI) 0.37-1.05; P = 0.1]. Age (OR 1.03, 95% CI 1.01-1.05; P < 0.05), left ventricular ejection fraction (OR 1.62, 95% CI 1.08-2.42; P < 0.05), creatinine ≥ 200 mg/dl (OR 2.21, 95% CI 1.17-4.04; P < 0.05) and endocarditis (OR 2.66, 95% CI 1.71-4.14; P < 0.05) emerged as risk factors for mortality. CONCLUSIONS: The type of valve initially implanted (mechanical or bioprosthetic) did not determine mortality. Instead, age, left ventricular ejection fraction, renal impairment and endocarditis were significant risk factors for in-hospital mortality.


Subject(s)
Bioprosthesis , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Heart Valve Prosthesis/adverse effects , Reoperation , Endocarditis/surgery , United Kingdom/epidemiology , Bioprosthesis/adverse effects , Treatment Outcome
17.
Cureus ; 16(1): e52550, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38371071

ABSTRACT

This study aimed to investigate the safety and efficacy of bioprosthetic (BV) versus mechanical valves (MV) on long-term outcomes in 50- to 70-year-old aortic stenosis (AS) patients. A literature search for articles published until April 2023 yielded 13 eligible studies, with 15,320 patients divided into BV (n = 7,320) and MV (n = 8,000) cohorts. The review was registered prospectively with PROSPERO (CRD42021278777). MV demonstrated a favorable hazard ratio (HR: 1.12, 95% CI: 1.00-1.25, I2 = 60%) and higher survival rates at 5 (OR:1.13, 95% CI: 1.02-1.25, I2 = 42%) and 10 years (OR: 1.13, 95% CI: 1.05-1.23, I2 = 0%). At 15 years, stroke incidence was comparable (OR: 1.12, 95% CI: 0.98-1.27, I2 = 4%). BV showed lower bleeding events (OR: 1.7, 95% CI: 1.18-2.46, I2 = 88%), but MV replacement showed lower reoperation incidence (OR: 0.27, 95% CI: 0.18-0.42, I2 = 85%). MV appears favorable for the long-term approach in AS management compared to BV.

19.
Gen Thorac Cardiovasc Surg ; 72(3): 149-156, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37452910

ABSTRACT

Current commercially available prosthetic valves suffer from limited size, high requirements for implantation technique, subvalvular structural destruction, and valve dysfunction due to proliferation of fibrous endothelial tissue. This study aims to perform the preclinical large animal experiments for surgically implanting a chimney-shaped artificial mechanical heart valve with zero left ventricular occupancy, which fully accommodates the movement of the valve leaflets in the valve frame and realizes completely supra-annular surgical implantation. A total of 7 sheep underwent the replacement of artificial valve, and 5 sheep survived normally until anatomical examination. The mechanical properties of these artificial mitral valves remain functionally normal. There was no obvious thromboembolism around the artificial valve and in the important organs. The tissue layer of suture ring was completely organized and endothelialized, and the thickness of tissue layer was about 0.6-1.0 mm. The follow-up of echocardiography showed that the left ventricular ejection fraction was normal (60-70%) before and 6 months after operation. The results of transvalvular pressure gradient and blood flow velocity of artificial valve were normal. Left ventricular retrograde angiography showed that the artificial valve was completely located in the left atrium with good position and normal opening and closing. There was no obvious perivalvular leakage and other abnormalities. At 3 and 6 months, there were no obvious abnormalities in blood routine test, liver and kidney function, and other indexes. The new chimney-shaped artificial mechanical valve implanted completely above the mitral annulus had good wear resistance, histocompatibility, and antithrombotic and hemodynamic performance.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Animals , Sheep , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Stroke Volume , Prosthesis Design , Ventricular Function, Left/physiology
SELECTION OF CITATIONS
SEARCH DETAIL