Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters








Database
Language
Publication year range
1.
J Nucl Med ; 65(5): 722-727, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38514081

ABSTRACT

Anti-programmed death 1 (PD-1) inhibitors are the standard of care for advanced gastroesophageal cancer. Although recommendations and approval by regulatory agencies are often based on programmed death ligand 1 (PD-L1) expression, pathologic assessments of PD-L1 status have several limitations. Single-site biopsies do not adequately capture disease heterogeneity within individual tumor lesions or among several lesions within the same patient, the PD-L1 combined positive score is a dynamic biomarker subject to evolution throughout a patient's disease course, and repeated biopsies are invasive and not always feasible. Methods: This was a prospective pilot study of the PD-L1-targeting radiotracer, 18F-BMS-986229, with PET imaging (PD-L1 PET) in patients with gastroesophageal cancer. Patients were administered the 18F-BMS-986229 radiotracer intravenously at a dose of 370 MBq over 1-2 min and underwent whole-body PET/CT imaging 60 min later. The primary objective of this study was to evaluate the safety and feasibility of 18F-BMS-986229. The trial is registered with ClinicalTrials.gov (NCT04161781). Results: Between February 3, 2020, and February 2, 2022, 10 patients with gastroesophageal adenocarcinoma underwent PD-L1 PET. There were no adverse events associated with the 18F-BMS-986229 tracer, and imaging did not result in treatment delays; the primary endpoint was achieved. Radiographic evaluation of PD-L1 expression was concordant with pathologic assessment in 88% of biopsied lesions, and 18F-BMS-986229 uptake on PET imaging correlated with pathologic evaluation by the combined positive score (Spearman rank correlation coefficient, 0.64). Seventy-one percent of patients with 18F-BMS-986229 accumulation on PET imaging also had lesions without 18F-BMS-986229 uptake, highlighting the intrapatient heterogeneity of PD-L1 expression. Patients treated with frontline programmed death 1 inhibitors who had 18F-BMS-986229 accumulation in any lesions on PET imaging had longer progression-free survival than patients without tracer accumulation in any lesions (median progression-free survival, 28.4 vs. 9.9 mo), though the small sample size prevents any definitive conclusions. Conclusion: PD-L1 PET imaging was safe, feasible, and concordant with pathologic evaluation and offers a potential noninvasive tool to assess PD-L1 expression.


Subject(s)
B7-H1 Antigen , Esophageal Neoplasms , Positron Emission Tomography Computed Tomography , Stomach Neoplasms , Humans , B7-H1 Antigen/metabolism , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/metabolism , Male , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/metabolism , Female , Middle Aged , Aged , Pilot Projects , Fluorine Radioisotopes , Prospective Studies , Adult
2.
J Nucl Med ; 62(9): 1228-1234, 2021 09 01.
Article in English | MEDLINE | ID: mdl-33517324

ABSTRACT

Blocking the interaction of the immune checkpoint molecule programmed cell death protein-1 and its ligand, PD-L1, using specific antibodies has been a major breakthrough for immune oncology. Whole-body PD-L1 expression PET imaging may potentially allow for a better prediction of response to programmed cell death protein-1-targeted therapies. Imaging of PD-L1 expression is feasible by PET with the adnectin protein 18F-BMS-986192. However, radiofluorination of proteins such as BMS-986192 remains complex and labeling yields are low. The goal of this study was therefore the development and preclinical evaluation of a 68Ga-labeled adnectin protein (68Ga-BMS-986192) to facilitate clinical trials. Methods:68Ga labeling of DOTA-conjugated adnectin (BXA-206362) was performed in NaOAc-buffer at pH 5.5 (50°C, 15 min). In vitro stability in human serum at 37°C was analyzed using radio-thin layer chromatography and radio-high-performance liquid chromatography. PD-L1 binding assays were performed using the transduced PD-L1-expressing lymphoma cell line U-698-M and wild-type U-698-M cells as a negative control. Immunohistochemical staining studies, biodistribution studies, and small-animal PET studies of 68Ga-BMS-986192 were performed using PD-L1-positive and PD-L1-negative U-698-M-bearing NSG mice. Results:68Ga-BMS-986192 was obtained with quantitative radiochemical yields of more than 97% and with high radiochemical purity. In vitro stability in human serum was at least 95% after 4 h of incubation. High and specific binding of 68Ga-BMS-986192 to human PD-L1-expressing cancer cells was confirmed, which closely correlates with the respective PD-L1 expression level determined by flow cytometry and immunohistochemistry staining. In vivo, 68Ga-BMS-986192 uptake was high at 1 h after injection in PD-L1-positive tumors (9.0 ± 2.1 percentage injected dose [%ID]/g) and kidneys (56.9 ± 9.2 %ID/g), with negligible uptake in other tissues. PD-L1-negative tumors demonstrated only background uptake of radioactivity (0.6 ± 0.1 %ID/g). Coinjection of an excess of unlabeled adnectin reduced tumor uptake of PD-L1 by more than 80%. Conclusion:68Ga-BMS-986192 enables easy radiosynthesis and shows excellent in vitro and in vivo PD-L1-targeting characteristics. The high tumor uptake combined with low background accumulation at early imaging time points demonstrates the feasibility of 68Ga-BMS-986192 for imaging of PD-L1 expression in tumors and is encouraging for further clinical applications of PD-L1 ligands.


Subject(s)
B7-H1 Antigen , Humans , Peptide Fragments , Tissue Distribution
SELECTION OF CITATIONS
SEARCH DETAIL