Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.359
Filter
Add more filters








Publication year range
1.
Abdom Radiol (NY) ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980403

ABSTRACT

OBJECTIVES: To compare the image quality of 1.5T and 3T prostate MRIs of the same post-hip arthroplasty patients, with a specific focus on the degree of susceptibility artifacts. METHODS: This single-center retrospective study included post-hip arthroplasty patients who underwent 1.5T prostate MRIs between 2021 and 2023, as well as comparative 3T prostate MRIs. Three blinded abdominal radiologists retrospectively reviewed their diffusion-weighted imaging (DWI, 50 s/mm2), T2-weighted imaging (T2WI), and dynamic contrast-enhanced imaging (DCE) to evaluate the image quality. The degree of susceptibility artifacts was categorized using a three-point scale, with 3 indicating the least artifact and 1 indicating the most. Image quality was also evaluated using Prostate Imaging Quality (PI-QUAL) version 2. The median of the three raters' scores was compared between 1.5T and 3T prostate MRIs using the Wilcoxon signed-rank test. The inter-rater agreement was evaluated using the multi-rater generalized kappa. RESULTS: Twenty pairs of 1.5T and 3T prostate MRI examinations from 20 unique patients were included. The DWI susceptibility artifact score at 1.5T was significantly higher than at 3T (mean score ± standard deviation, 2.80 ± 0.41 vs. 2.35 ± 0.93, p = 0.014). In contrast, no significant differences were observed in the susceptibility artifact scores in T2WI and DCE, or in the PI-QUAL score. The inter-reader agreement in the susceptibility artifact score was moderate (multi-rater generalized kappa: 0.60) in DWI, perfect in T2WI (not applicable), and substantial (0.65) in DCE. The inter-reader agreement was fair (0.27) in the PI-QUAL score. CONCLUSION: Using 1.5T scanners may be preferable to reduce susceptibility artifacts from hip prostheses in DWI.

2.
ACG Case Rep J ; 11(7): e01413, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39006051

ABSTRACT

Intestinal subepithelial lesions are often encountered during endoscopy. Etiologies can include lesions intrinsic or extrinsic to the gastrointestinal wall. They can present a diagnostic dilemma as simple mucosal biopsies are often nondiagnostic. The combination of characteristic radiographic, endoscopic, and endosonographic features can aid in a definitive diagnosis precluding the need for unnecessary tissue sampling of extrinsic compressive etiologies. The location of the space of Retzius which is the traditional site of penile prosthetic pump reservoir insertion can predispose to cecal compression. We present a rare case of a penile prosthetic pump reservoir presenting as a cecal subepithelial mass on endoscopy.

3.
Appl Ergon ; 120: 104344, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38991493

ABSTRACT

Limb amputation can lead to significant functional challenges in daily activities, prompting amputees to use prosthetic devices (PDs). However, the cognitive demands of PDs and usability issues have resulted in user rejections. This study aimed to create a Human Performance Model for Upper-Limb Prosthetic Devices (HPM-UP). The model used formulations of learnability, error rate, memory load, efficiency, and satisfaction to assess usability. The model was validated in an experiment with 30 healthy participants using a bypass prosthetic device. Findings indicated that the HPM-UP successfully predicted the usability of prosthetic devices, aligning with human subject data. This research proposes a quantitative approach to predict upper limb prosthetic device usability by quantifying each dimension and computationally connecting them. The model, available on Github and executable with Rstudio, could enable clinicians to assess and analyze the human performance of various commercial prostheses, aiding in recommending optimal devices for patients.

4.
Cureus ; 16(5): e61430, 2024 May.
Article in English | MEDLINE | ID: mdl-38947601

ABSTRACT

This case report describes the care given to a 58-year-old male patient with severe upper jaw atrophy. The treatment strategy involved utilizing zygomatic implants in conjunction with endosteal implants to rehabilitate both the maxilla and mandible. Temporary prostheses were used during the healing phase, followed by the fabrication and placement of final prostheses. The utilization of zygomatic implants offers advantages such as immediate stabilization and function without the need for extensive bone grafting. This approach not only reduces treatment time and costs but also enhances patient outcomes. Furthermore, guided surgical techniques are increasingly employed to ensure precise implant placement, optimizing prosthetic support.

5.
Surg Radiol Anat ; 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38951185

ABSTRACT

INTRODUCTION: The current study, which delves into proximal tibia morphometric parameters in a Greek sample, not only analyzes whether specific linear distance ratios are consistent but also paves the way for a potential novel metric system for knee arthroplasty imaging studies using constant ratios. These findings could have significant implications for future enlarged research and clinical practice. METHODS: A total of 38 dried tibiae were evaluated by two independent investigators. The following distances were measured with a digital Vernier sliding caliper: (1) the mediolateral distance of the proximal surface (A), (2) the anteroposterior distance of the proximal surface (B), (3) The longitudinal length of the bone (C), (4) the line connecting the anterior margin of the proximal surface with the highest peak of the tibia tuberosity (D), (5) the depth of the proximal margin of the medial articular facet (AF) (medial plateau) (E) and (6) the depth of the proximal margin of the lateral AF (lateral plateau) (F). RESULTS: The A, B, C, D, E, and F mean distances were 71.3 mm, 47.4 mm, 340.2 mm, 37.1 mm, 42 mm, and 35.9 mm. Reliability analysis for each observer on all measurements revealed an interclass correlation (ICC) score of 0.975 (observer 1) and 0.971 (observer 2). The ratio A/B was 1.5, A/C was a constant 0.2, and D/C was 0.1. The ratio E/F was 1.2. The six measurements (A-F) showed excellent inter-observer reliability (all ICC values > 0.990). CONCLUSIONS: The study established constant ratios of the studied linear distances around the proximal tibia. Considering these ratios, asymmetrical tibial components in knee arthroplasty seem to replicate the native anatomy more closely. Furthermore, the distance from the anterior margin of the proximal surface to the tibial tuberosity peak, constituting one-tenth of the longitudinal length of the tibia, shows promise as a metric system for imaging studies, especially in assessing lesions around tibial components.

6.
J Robot Surg ; 18(1): 274, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38951387

ABSTRACT

Breast cancer is the most common malignant tumor worldwide, and mastectomy remains the primary strategy for treating early stage breast cancer. However, the complication rates, surgical variables, and oncologic safety of minimally invasive nipple-sparing mastectomy (MINSM) have not been fully addressed. We systematically searched PubMed, Web of Science, Embase, and the Cochrane Library for randomized-controlled trials (RCTs) and non-RCTs that compared MINSM with conventional nipple-sparing mastectomy (CNSM), both followed by Prosthesis Breast Reconstruction (PBR). The main outcomes observed included overall complications, (Grade III) complications, skin and nipple necrosis, wound dehiscence, infection, seroma, hematoma, implant loss, and oncologic safety (positive margins and recurrence). Secondary outcomes included operation time, blood loss, hospital stay, cost-effectiveness, and patient satisfaction. Binary and continuous variables were compared using odds ratios (OR) and mean differences (MD) with 95% confidence intervals (CI). A total of 10 studies involving 2,166 patients were included. There were no statistically significant differences between MINSM and CNSM in terms of skin necrosis, wound dehiscence, infection, seroma, hematoma, implant loss, or oncologic safety. However, MINSM significantly reduced overall complications (OR = 0. 74, 95% CI [0. 58, 0. 94], p = 0. 01) and (Grade III) complications (OR = 0. 47, 95% CI [0. 31, 0. 71], p = 0. 0003). Nipple necrosis events were also significantly reduced in the MINSM group (OR = 0. 49, 95% CI [0. 30, 0. 80], p = 0. 005). Patient satisfaction improved notably in the MINSM group. Additionally, compared with the CNSM group, the MINSM group had longer operating times (MD = 46. 88, 95% CI [19. 55, 74. 21], p = 0. 0008) and hospital stays (MD = 1. 39, 95% CI [0. 65, 2. 12], p < 0. 001), while intraoperative blood loss was significantly reduced (MD = -29. 05, 95% CI [-36. 20, -21. 90], p < 0. 001). Compared with CNSM, MINSM offers advantages in reducing complications and intraoperative blood loss, as well as improving aesthetic outcomes and patient satisfaction. Therefore, MINSM may become a viable option for breast surgery. Nevertheless, a long-term evaluation of the oncologic safety of this approach is necessary to ensure its efficacy and safety for patients.


Subject(s)
Breast Neoplasms , Mammaplasty , Minimally Invasive Surgical Procedures , Nipples , Postoperative Complications , Female , Humans , Breast Implants , Breast Neoplasms/surgery , Length of Stay/statistics & numerical data , Mammaplasty/methods , Mastectomy/methods , Minimally Invasive Surgical Procedures/methods , Nipples/surgery , Operative Time , Organ Sparing Treatments/methods , Patient Satisfaction , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome
7.
J Oral Implantol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38962860

ABSTRACT

This study aimed to identify the ideal inter-implant distance for optimum outcome on immediately loaded implant supported prosthesis. Hence this study was taken up to analyze the effect of varying inter-implant distance on fracture resistance of implant supported provisional FDP. A total of 24 bis-acrylate composite resin samples were prepared. Inter- implant distance was present in the metal die for placement of dummy implants at distances of 14 mm, 21 mm & 30 mm respectively. Wax-up for 3 unit, 4 unit & 5 unit implant supported provisional restoration were made. Silicone molds were used for making multiple interim prostheses using bis-acrylate composite material. All samples were subjected to fracture test in the universal testing machine with a crosshead speed of 1 mm/min. All samples were loaded with gradual force starting from 100 N till it fractured. The Load was applied at the center of prosthesis. Data was analyzed by one way ANOVA and Bonferroni post hoc test. Mean Fracture resistance of 3 unit provisional FDP at 14 mm of inter-implant distance showed 1342.61 ± 179.15 N. Mean Fracture resistance of 4 unit provisional FDP at 21 mm of inter-implant distance showed 1420.44 ± 170.37 N. Mean Fracture resistance of 5 unit provisional FDP at 30 mm of inter-implant distance showed 791.61 ± 203.59 N. Both 14mm and 21mm of inter implant distance are suitable span lengths to be considered for the optimum outcome during immediately loading with implant supported provisional restorations. Limitations of the study was force application was static in nature and not dynamic and the arch form was not "U" shaped but longitudinal using Bis-Acrly material only with no cantilever. Future studies can be done to evaluate the fracture resistance of bis- acrylate material considering biomechanics and arch form of natural dentition. Distal cantilever should be considered along with different material for fabricating provisional restoration.

9.
Future Cardiol ; : 1-9, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38985451

ABSTRACT

Mitral valve repair is the ideal intervention for mitral valve disease with excellent long-term survival comparable to the age-matched general population. When the mitral valve is not repairable, mechanical prostheses may be associated with improved survival as compared with biological prostheses. Newer mechanical and biological valve prostheses have the potential to improve outcomes following mitral valve replacement in young patients. Patients presenting for mitral valve surgery after failed transcatheter mitral valve-in-valve have high rates of postoperative mortality and morbidity, exceeding those seen with reoperative mitral valve surgery, which poses issues in young patients who have a higher cumulative incidence of reintervention.


Patients presenting with mitral valve disease, the most common type of heart valve disease, have a survival advantage when they undergo mitral valve repair as opposed to replacement, and this is particularly true for young patients. When the mitral valve is not repairable, mechanical prostheses (prosthetic implants) may be associated with improved survival as compared with biological prostheses, and this difference is mostly observed until the age of 70 years. Newer techniques of treating mitral valve disease without requiring open heart surgery have not yet been shown to be superior or even equivalent to traditional open heart surgery in the general population. Patients presenting for mitral valve surgery after failure of these newer techniques have high rates of death, exceeding those seen with mitral valve reoperation, which has important implications for young patients with mitral valve disease.

11.
J Orthop ; 57: 72-78, 2024 Nov.
Article in English | MEDLINE | ID: mdl-38988723

ABSTRACT

Purpose: Resection arthroplasty (RA) is still the most common surgical intervention for the treatment of symptomatic trapeziometacarpal (TMC) joint osteoarthritis. The implantation of a dual mobility prosthesis may represent a joint function preserving alternative. The aim of the presented study is to prospectively compare the outcomes of RA with dual mobility prosthesis. Methods: In this 2-center non-randomized prospective study, we compared results of RA (n = 22) with implantation of a dual mobility prosthesis (n = 49) (Touch®) at a minimum of 3-year follow-up. The patients underwent preoperative assessments and postoperative follow-up at 6 weeks, 3, 6, 12, 24, and 36 months. Comparisons were conducted, covering pain assessment via the visual analogue scale (VAS), thumb range of motion (ROM), pinch and grip strength, as well as functional scores and radiological examinations. Results: The time intervals from surgery until absence of pain on the VAS (3 months: 3 vs 1, p = 0.0001), recovery of ROM in radial (3 months: 33° vs 42°, p = 0.0001), and palmar abduction (3 months: 33° vs 48°, p = 0.0001), were significantly longer for the RA group compared with the prosthesis group. At 3-year follow-up there was no significant difference in absence of pain, ROM and grip strength between both groups. Key pinch strength was significantly weaker in the RA group compared to prosthesis group at 3 months (2.6 kg vs 4.6 kg, p = 0.001), to 3-year follow-up (3.1 kg vs 5.7 kg, p = 0.0001). The final mean DASH (15.5 vs 13.2, p = 0.01) and MHQ scores (78 vs 82, p = 0.01) were significantly better in the prosthesis group. Conclusion: Both techniques show high patient satisfaction in mid-term follow-up. Dual mobility TMC joint arthroplasty seems to be associated with a superior pinch strength and shorter time of recovery as compared to patients after RA.

12.
J Med Case Rep ; 18(1): 340, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-38997777

ABSTRACT

BACKGROUND: This case highlights several complications of a late and rare presentation of culture-negative Streptococcus pyogenes endocarditis of a previously repaired mitral valve with an annuloplasty ring including recurrent cardioembolic strokes, which was initially missed on transthoracic echocardiography. CASE PRESENTATION: A 66-year-old Caucasian female with prior mitral valve prolapse status post mitral valve annuloplasty and left atrial appendage occlusion, followed by two strokes, presented with supraventricular tachycardia that resolved spontaneously. During an inpatient admission, she developed symptoms of another stroke, and imaging studies were suggestive of recurrent cardioembolic phenomenon. Additional workup revealed two small intra-atrial masses adherent to the mitral annuloplasty ring missed on prior evaluation for recurrent stroke. She underwent surgical repair in the setting of a chronic culture-negative infectious endocarditis with Streptococcus pyogenes and recovered well with no further cardioembolic phenomenon. CONCLUSION: This case serves to highlight the importance of having a higher index of suspicion in any cardiac prosthesis patient for endocarditis when presenting with symptoms such as recurrent stroke, arrhythmias, and abnormal cardiac lab work. It also demonstrates the need for appropriate imaging with transthoracic echocardiography followed by transesophageal echocardiography and reviews surgical indications to diagnose and treat culture-negative endocarditis.


Subject(s)
Echocardiography , Endocarditis, Bacterial , Streptococcal Infections , Streptococcus pyogenes , Humans , Female , Aged , Streptococcus pyogenes/isolation & purification , Streptococcal Infections/diagnostic imaging , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/surgery , Mitral Valve Annuloplasty , Mitral Valve Prolapse/surgery , Mitral Valve Prolapse/diagnostic imaging , Echocardiography, Transesophageal , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/surgery
13.
Molecules ; 29(13)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38999030

ABSTRACT

Coatings with xenogenic materials, made of detonation nanodiamonds, provide additional strength and increase elasticity. A functionally developed surface of nanodiamonds makes it possible to apply antibiotics. Previous experiments show the stability of such coatings; however, studies on stability in the bloodstream and calcification of the material in natural conditions have yet to be conducted. Tritium-labeled nanodiamonds (negative and positive) were obtained by the tritium activation method and used to develop coatings for a pork aorta to analyze their stability in a pig's bloodstream using a radiotracer technique. A chitosan layer was applied from a solution of carbonic acid under high-pressure conditions to prevent calcification. The obtained materials were used to prepare a porcine conduit, which was surgically stitched inside the pig's aorta for four months. The aorta samples, including nanodiamond-coated and control samples, were analyzed for nanodiamond content and calcium, using the radiotracer and ICP-AES methods. A histological analysis of the materials was also performed. The obtained coatings illustrate a high in vivo stability and low levels of calcification for all types of nanodiamonds. Even though we did not use additional antibiotics in this case, the development of infection was not observed for negatively charged nanodiamonds, opening up prospects for their use in developing coatings.


Subject(s)
Coated Materials, Biocompatible , Nanodiamonds , Tritium , Animals , Nanodiamonds/chemistry , Swine , Coated Materials, Biocompatible/chemistry , Tritium/chemistry , Aorta , Bioprosthesis , Chitosan/chemistry , Heart Valve Prosthesis
14.
J Clin Med ; 13(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38999314

ABSTRACT

Background: Previous studies have assessed the capability of PRAAT for acoustic voice analysis in total laryngectomized (TL) patients, although this software was designed for acoustic analysis of laryngeal voice. Recently, we have witnessed the development of specialized acoustic analysis software, Tracheoesophageal Voice Analysis (TEVA). This study aims to compare the analysis with both programs in TL patients. Methods: Observational analytical study of 34 TL patients where a quantitative acoustic analysis was performed for stable phonation with vowels [a] and [i] as well as spectrographic characterization using the TEVA and PRAAT software. Results: The Voice Handicap Index (VHI-10) showed a mean score of 11.29 ± 11.16 points, categorized as a moderate handicap. TEVA analysis found lower values in the fundamental frequency vs. PRAAT (p < 0.05). A significant increase in shimmer values was observed with TEVA (>20%). No significant differences were found between spectrographic analysis with TEVA and PRAAT. Conclusions: Tracheoesophageal speech is an alaryngeal voice, characterized by a higher degree of irregularity and noise compared to laryngeal speech. Consequently, it necessitates a more tailored approach using objective assessment tools adapted to these distinct features, like TEVA, that are designed specifically for TL patients. This study provides statistical evidence supporting its reliability and suitability for the evaluation and tracking of tracheoesophageal speakers.

15.
J Clin Med ; 13(13)2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38999532

ABSTRACT

Background: The treatment of spheno-orbital meningiomas (SOMs) requires extensive bone resections, creating significant defects in a complex geometrical space. Bone reconstruction represents a fundamental step that optimizes long-term aesthetic and functional outcomes. In recent years, 3D printing technology has also been exploited for complex skull base reconstructions, but reports remain scarce. Methods: We retrospectively analyzed four consecutive patients who underwent SOM resection and one-step 3D PEEK customized reconstruction from 2019 to 2023. A systematic review of 3D printing customized implants for SOM was then performed. Results: All patients underwent a frontotemporal craniotomy, removal of SOM, and reconstruction of the superolateral orbital wall and pterional region. The aesthetic outcome was extremely satisfactory in all cases. No orbital implant malposition or infectious complications were documented. Eleven papers were included in the literature review, describing 27 patients. Most (23) patients underwent a single-stage reconstruction; in three cases, the implant was positioned to correct postoperative delayed enophthalmos. Porous titanium was the most used material (16 patients), while PEEK was used in three cases. Prosthesis malposition was described in two (7.4%) patients. Conclusions: Single-step reconstruction with a personalized 3D PEEK prosthesis represents a valid reconstruction technique for the treatment of SOMs with good aesthetic outcomes.

16.
Am J Cardiol ; 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-39004197

ABSTRACT

To compare long-term outcomes of mechanical versus bioprosthetic aortic valve replacement (AVR) in patients under the age of 50, we performed a study-level meta-analysis with reconstructed time-to-event data including studies published by December of 2023. The primary outcome was overall survival. Secondary outcomes included reoperation, major bleeding, and stroke. Five studies met our inclusion criteria with a total of 4245 patients (2311 mechanical, 1934 bioprosthetic). All studies were observational and the mean age of groups across the studies ranged from 38.2 to 43.0 years. The median follow-up time was 11.4 years (IQR, 6.9-15.0). Bioprosthetic AVR was associated with reduced overall survival and higher risk of all-cause death (HR, 1.170 [95% CI, 1.002-1.364], P=0.046), increased risk of reoperation over time (HR, 2.581, [95% CI, 2.102-3.168], P<0.001), decreased risk of major bleeding (HR, 0.500, [95% CI, 0.367-0.682], P<0.001), and decreased risk of stroke (HR, 0.751, [95% CI, 0.565-0.998], P=0.049) compared to mechanical AVR in patients under 50. In conclusion, for patients under the age of 50, bioprosthetic AVR is associated with increased mortality and risk of reoperation compared to mechanical valves. On the other hand, mechanical AVR is associated with an increased risk of major bleeding events and stroke. These aspects should be carefully considered during the selection of valve type in this age group; however, we should keep in mind that the statistically significant differences in the risk of all-cause death and stroke might not be clinically relevant (due to marginal statistical significance).

17.
Article in English | MEDLINE | ID: mdl-38953771

ABSTRACT

OBJECTIVES: One stage functional jaw reconstruction is defined as the resection and reconstruction of segmental defects in conjunction with the placement of dental implants in an ideal prosthetic position and loaded with a provisional restoration, during one surgical procedure. The aim of the study is to describe clinical outcomes of patients who underwent one stage functional jaw reconstruction. METHODS: Patients who underwent one-stage functional jaw reconstruction, from January 2013 to March 2016 were recalled in 2022 and 2023. Planning and execution for the reconstruction utilized either analogue or digital techniques. Outcome parameters recorded were treatment-related outcomes at patient level, implant-related outcomes and patient-reported outcome measures. RESULTS: Eighteen patients underwent one-stage jaw reconstruction with a total of 57 implants. Four patients had maxillary and 14 had mandibular reconstructions. Ten patients underwent postoperative radiotherapy. Ten patients were planned using analogue and eight by digital planning. Three patients had partial flap necrosis, three patients had plate fractures, implant loss was seen in one patient and four patients died during the period. A functional prosthesis was provided in 16 out of the 18 patients. CONCLUSION: One-stage functional jaw reconstruction is a predictable method for providing rehabilitation with successful outcomes at 7-11 years. However, caution should be exercised when the treatment modality is carried out in patients with malignant pathologies who have undergone radiotherapy.

18.
Cureus ; 16(6): e61764, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38975453

ABSTRACT

When considering dental restorations, the use of fixed partial dentures is one of the most widely accepted treatment options. In the past, fabrication was done using traditional techniques and the conventional workflow was by far the popular method; however, nowadays digital workflows are being used as a means to produce the prosthesis. This systematic review aims to compare the workflows by considering their respective qualities, such as precision, efficiency, cost-effectiveness, and clinical performance. A complete search has been carried out to incorporate any relevant studies published between the years 2012 and 2023 in databases such as Scopus, Web of Science, PubMed, ScienceDirect, and Cochrane Library. Two independent reviewers screened articles for inclusion and assessed the studies' methodological quality rating via the NIH Tool. A total of 22 relevant articles were reviewed after a systematic search strategy. The main outcome of the review was digital workflows were found to reduce working time, eliminate the selection of trays, minimize material consumption, and enhance patient comfort and acceptance. The studies also showed that digital workflows resulted in greater patient satisfaction and higher success rates than conventional workflows. Workflows for digital dentistry demonstrated to be better than traditional ones due to the cost-effectiveness, accuracy, and time optimization for the fabrication of fixed prostheses.

19.
J Sex Med ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38979774

ABSTRACT

BACKGROUND: Chlorhexidine gluconate (CHG) (0.05%) has recently been suggested as both a dip for the hydrophilic surface and an irrigation solution in the setting of penile prosthesis (PP) surgery. AIM: The study sought to compare the antimicrobial efficacy of 0.05% CHG with vancomycin and gentamicin (VG) antibiotics as dip and/or irrigation solutions in the setting of a hydrophilic PP surface in vitro. METHODS: Sterile PPs with a hydrophilic coating were obtained. A series of experiments were performed to evaluate the efficacy of normal saline (NS), 0.05% CHG, or VG as dip and/or irrigation solutions to reduce methicillin-sensitive Staphylococcus aureus adhesion to PP surfaces. The 8-mm discs from PPs were incubated in 105 colony-forming units/mL of methicillin-sensitive S aureus for 48 hours, plated, and counted. Disc-diffusion tests were conducted by suspending 6-mm discs for 2 minutes in NS, 0.05% CHG, or VG, then placing them coated side down onto plates streaked with the following organisms: methicillin-sensitive S aureus, S epidermidis, Enterococcus, and Escherichia coli. After 24 hours of growth, zones of inhibition were measured. OUTCOMES: We found average bacterial counts (colony-forming units/mL) and zones of inhibition (mm) following a series of treatment protocols of PP discs. RESULTS: PP discs dipped in VG reduced bacterial adhesion to the implant surface >0.05% CHG (~5.5 log vs ~1.5 log; P < .01). Discs irrigated with either 0.05% CHG or NS removed all dip solution adsorbed to the hydrophilic surface, allowing bacterial growth. VG irrigation adsorbed to the hydrophilic surface even after 0.05% CHG or NS dips, reducing bacterial adherence (~3 log). Dipping and irrigating discs with VG was most effective in reducing adherent bacteria (~5.5 log) and was the only irrigation that showed antimicrobial activity. CLINICAL TRANSLATION: VG, when used both as a prophylactic dip and as an intraoperative irrigation solution for hydrophilic penile implant surfaces, has improved efficacy to 0.05% CHG and NS. STRENGTHS AND LIMITATIONS: This is the first study to compare the use of VG, 0.05% CHG, and NS as prophylactic dips and intraoperative irrigations for hydrophilic penile implant surfaces. Limitations include the use of in vitro studies, which serve as a proxy for in vivo practices and may not be entirely accurate nor translatable clinically. CONCLUSION: We demonstrated the superior efficacy of VG as a combined dip and irrigation solution for hydrophilic penile implant surfaces compared with 0.05% CHG.

20.
Brain Commun ; 6(4): fcae044, 2024.
Article in English | MEDLINE | ID: mdl-38978721

ABSTRACT

Paediatrics with congenital upper-limb reduction deficiency often face difficulties with normal development such as motor skills, needing assistance with daily activities such as self-care limitations with certain movements, sports, or activities. The purpose of this non-randomized longitudinal controlled trial was to assess, using intent-to-treat analysis, the effects of an 8-week home intervention of prosthetic use on the sensorimotor cortex in paediatrics with congenital upper-limb reduction deficiency. A paediatric population with congenital upper-limb reduction deficiency (n = 14) who were aged 6-18 years and who had a 20° or greater range of motion in the appropriate joint of the affected arm to move the body-powered prosthesis were enrolled. An age- and sex-matched control group (n = 14) was also enrolled. Participants were non-randomized and fitted with a custom low-cost 3D printed prosthesis and participated in 8 weeks of prosthetic use training at home. Control participants utilized a prosthetic simulator. The home intervention incorporated daily use training and exercises utilizing the prosthesis in direct use and assistive tasks explained by the researchers. After the home intervention, both groups displayed significant improvements in gross manual dexterity. During prosthetic use with the affected limb, significant increases in oxygenated hemodynamic responses were only displayed in the left premotor cortex of the upper-limb reduction deficiency group. The novel findings of this non-randomized longitudinal controlled trial suggest that the intervention may have improved the functional role of the left hemisphere which translated to the improvement of learning direction during adaptation to visuomotor control. The prosthetic home intervention was assumed to provide closed-loop training which could provide a direct benefit to the motor development of paediatrics with upper-limb reduction deficiency.

SELECTION OF CITATIONS
SEARCH DETAIL