Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Int J Neonatal Screen ; 10(1)2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38535123

ABSTRACT

In this study, we evaluated the implementation of a second-tier genetic screening test using an amplicon-based next-generation sequencing (NGS) panel in our laboratory during the period of 1 September 2021 to 31 August 2022 for the newborn screening (NBS) of six conditions for inborn errors of metabolism: citrullinemia type II (MIM #605814), systemic primary carnitine deficiency (MIM #212140), glutaric acidemia type I (MIM #231670), beta-ketothiolase deficiency (#203750), holocarboxylase synthetase deficiency (MIM #253270) and 3-hydroxy-3-methylglutaryl-CoA lyase deficiency (MIM # 246450). The custom-designed NGS panel can detect sequence variants in the relevant genes and also specifically screen for the presence of the hotspot variant IVS16ins3kb of SLC25A13 by the copy number variant calling algorithm. Genetic second-tier tests were performed for 1.8% of a total of 22,883 NBS samples. The false positive rate for these six conditions after the NGS second-tier test was only 0.017%, and two cases of citrullinemia type II would have been missed as false negatives if only biochemical first-tier testing was performed. The confirmed true positive cases were citrullinemia type II (n = 2) and systemic primary carnitine deficiency (n = 1). The false positives were later confirmed to be carrier of citrullinemia type II (n = 2), carrier of glutaric acidemia type I (n = 1) and carrier of systemic primary carnitine deficiency (n = 1). There were no false negatives reported. The incorporation of a second-tier genetic screening test by NGS greatly enhanced our program's performance with 5-working days turn-around time maintained as before. In addition, early genetic information is available at the time of recall to facilitate better clinical management and genetic counseling.

2.
World J Pediatr ; 2024 Feb 24.
Article in English | MEDLINE | ID: mdl-38401044

ABSTRACT

INTRODUCTION: Methylmalonic acidemia (MMA) is a disorder of autosomal recessive inheritance, with an estimated prevalence of 1:50,000. First-tier clinical diagnostic tests often return many false positives [five false positive (FP): one true positive (TP)]. In this work, our goal was to refine a classification model that can minimize the number of false positives, currently an unmet need in the upstream diagnostics of MMA. METHODS: We developed machine learning multivariable screening models for MMA with utility as a secondary-tier tool for false positives reduction. We utilized mass spectrometry-based features consisting of 11 amino acids and 31 carnitines derived from dried blood samples of neonatal patients, followed by additional ratio feature construction. Feature selection strategies (selection by filter, recursive feature elimination, and learned vector quantization) were used to determine the input set for evaluating the performance of 14 classification models to identify a candidate model set for an ensemble model development. RESULTS: Our work identified computational models that explore metabolic analytes to reduce the number of false positives without compromising sensitivity. The best results [area under the receiver operating characteristic curve (AUROC) of 97%, sensitivity of 92%, and specificity of 95%] were obtained utilizing an ensemble of the algorithms random forest, C5.0, sparse linear discriminant analysis, and autoencoder deep neural network stacked with the algorithm stochastic gradient boosting as the supervisor. The model achieved a good performance trade-off for a screening application with 6% false-positive rate (FPR) at 95% sensitivity, 35% FPR at 99% sensitivity, and 39% FPR at 100% sensitivity. CONCLUSIONS: The classification results and approach of this research can be utilized by clinicians globally, to improve the overall discovery of MMA in pediatric patients. The improved method, when adjusted to 100% precision, can be used to further inform the diagnostic process journey of MMA and help reduce the burden for patients and their families.

3.
Clin Chem Lab Med ; 62(3): 493-505, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-37794778

ABSTRACT

OBJECTIVES: Acylcarnitine and amino acid analyses of dried blood spot (DBS) samples using tandem mass spectrometry in newborn screening (NBS) programmes can generate false positive (FP) results. Therefore, implementation of second-tier tests (2TTs) using DBS samples has become increasingly important to avoid FPs. The most widely used 2TT metabolites include methylmalonic acid, 3-hydroxypropionic acid, methylcitric acid, and homocysteine. METHODS: We simultaneously measured 46 underivatised metabolites, including organic acids, acylglycine and acylcarnitine isomers, homocysteine, and orotic acid, in DBS samples using tandem mass spectrometry. To validate this method, we analysed samples from 147 healthy newborns, 160 patients with genetic disorders diagnosed via NBS, 20 patients with acquired vitamin B12 deficiency, 10 newborns receiving antibiotic treatment, and nine external quality control samples. RESULTS: The validation study revealed that 31 metabolites showed good analytical performance. Furthermore, this method detected key metabolites for all diseases associated with increased levels of the following acylcarnitines: C3, C4, C5, C4DC/C5OH, and C5DC. The sensitivity of this method to detect all diseases was 100 %, and the specificity was 74-99 %, except for glutaric aciduria type 1. This method can also be used to diagnose mitochondrial fatty acid ß-oxidation disorders (FAODs) and urea cycle defects (UCDs). CONCLUSIONS: We have described a 2TT panel of 31 metabolites in DBS samples based on an easy and rapid method without derivatisation. Its implementation allowed us to distinguish between different organic acidurias, some FAODs, and UCDs. This new strategy has increased the efficiency of our NBS programme by reducing FP and false negative results, second sample requests, and the time required for diagnosis.


Subject(s)
Amino Acid Metabolism, Inborn Errors , Brain Diseases, Metabolic , Carnitine/analogs & derivatives , Glutaryl-CoA Dehydrogenase/deficiency , Neonatal Screening , Tandem Mass Spectrometry , Humans , Infant, Newborn , Tandem Mass Spectrometry/methods , Neonatal Screening/methods , Spain , Chromatography, Liquid/methods , Homocysteine , Dried Blood Spot Testing/methods
4.
Int J Neonatal Screen ; 9(2)2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37367212

ABSTRACT

Fabry disease is an X-linked progressive lysosomal disorder, due to α-galactosidase A deficiency. Patients with a classic phenotype usually present in childhood as a multisystemic disease. Patients presenting with the later onset subtypes have cardiac, renal and neurological involvements in adulthood. Unfortunately, the diagnosis is often delayed until the organ damage is already irreversibly severe, making specific treatments less efficacious. For this reason, in the last two decades, newborn screening has been implemented to allow early diagnosis and treatment. This became possible with the application of the standard enzymology fluorometric method to dried blood spots. Then, high-throughput multiplexable assays, such as digital microfluidics and tandem mass spectrometry, were developed. Recently DNA-based methods have been applied to newborn screening in some countries. Using these methods, several newborn screening pilot studies and programs have been implemented worldwide. However, several concerns persist, and newborn screening for Fabry disease is still not universally accepted. In particular, enzyme-based methods miss a relevant number of affected females. Moreover, ethical issues are due to the large number of infants with later onset forms or variants of uncertain significance. Long term follow-up of individuals detected by newborn screening will improve our knowledge about the natural history of the disease, the phenotype prediction and the patients' management, allowing a better evaluation of risks and benefits of the newborn screening for Fabry disease.

5.
Int J Neonatal Screen ; 10(1)2023 Dec 25.
Article in English | MEDLINE | ID: mdl-38248631

ABSTRACT

In the last two decades, the development of high-throughput diagnostic methods and the availability of effective treatments have increased the interest in newborn screening for lysosomal storage disorders. However, long-term follow-up experience is needed to clearly identify risks, benefits and challenges. We report our 8-year experience of screening and follow-up on about 250,000 neonates screened for four lysosomal storage diseases (Pompe disease, mucopolysaccharidosis type I, Fabry disease, Gaucher disease), using the enzyme activity assay by tandem mass spectrometry, and biomarker quantification as a second-tier test. Among the 126 positive newborns (0.051%), 51 infants were confirmed as affected (positive predictive value 40%), with an overall incidence of 1:4874. Of these, three patients with infantile-onset Pompe disease, two with neonatal-onset Gaucher disease and four with mucopolysaccharidosis type I were immediately treated. Furthermore, another four Gaucher disease patients needed treatment in the first years of life. Our study demonstrates the feasibility and effectiveness of newborn screening for lysosomal storage diseases. Early diagnosis and treatment allow the achievement of better patient outcomes. Challenges such as false-positive rates, the diagnosis of variants of uncertain significance or late-onset forms and the lack of treatment for neuronopathic forms, should be addressed.

6.
Crit Rev Clin Lab Sci ; 59(4): 257-277, 2022 06.
Article in English | MEDLINE | ID: mdl-35037566

ABSTRACT

Mucopolysaccharidosis type I (MPS I), a lysosomal storage disease caused by a deficiency of α-L-iduronidase, leads to storage of the glycosaminoglycans, dermatan sulfate and heparan sulfate. Available therapies include enzyme replacement and hematopoietic stem cell transplantation. In the last two decades, newborn screening (NBS) has focused on early identification of the disorder, allowing early intervention and avoiding irreversible manifestations. Techniques developed and optimized for MPS I NBS include tandem mass-spectrometry, digital microfluidics, and glycosaminoglycan quantification. Several pilot studies have been conducted and screening programs have been implemented worldwide. NBS for MPS I has been established in Taiwan, the United States, Brazil, Mexico, and several European countries. All these programs measure α-L-iduronidase enzyme activity in dried blood spots, although there are differences in the analytical strategies employed. Screening algorithms based on published studies are discussed. However, some limitations remain: one is the high rate of false-positive results due to frequent pseudodeficiency alleles, which has been partially solved using post-analytical tools and second-tier tests; another involves the management of infants with late-onset forms or variants of uncertain significance. Nonetheless, the risk-benefit ratio is favorable. Furthermore, long-term follow-up of patients detected by neonatal screening will improve our knowledge of the natural history of the disease and inform better management.


Subject(s)
Mucopolysaccharidosis I , Heparitin Sulfate , Humans , Iduronidase/analysis , Infant , Infant, Newborn , Mucopolysaccharidosis I/diagnosis , Neonatal Screening/methods , Tandem Mass Spectrometry/methods
7.
Int J Neonatal Screen ; 7(3)2021 Jul 26.
Article in English | MEDLINE | ID: mdl-34449524

ABSTRACT

Historically, the analyses used for newborn screening (NBS) were biochemical, but increasingly, molecular genetic analyses are being introduced in the workflow. We describe the application of molecular genetic analyses in the Danish NBS programme and show that second-tier molecular genetic testing is useful to reduce the false positive rate while simultaneously providing information about the precise molecular genetic variant and thus informing therapeutic strategy and easing providing information to parents. When molecular genetic analyses are applied as second-tier testing, valuable functional data from biochemical methods are available and in our view, such targeted NGS technology should be implemented when possible in the NBS workflow. First-tier NGS technology may be a promising future possibility for disorders without a reliable biomarker and as a general approach to increase the adaptability of NBS for a broader range of genetic diseases, which is important in the current landscape of quickly evolving new therapeutic possibilities. However, studies on feasibility, sensitivity, and specificity are needed as well as more insight into what views the general population has towards using genetic analyses in NBS. This may be sensitive to some and could have potentially negative consequences for the NBS programme.

8.
Biomolecules ; 11(7)2021 06 27.
Article in English | MEDLINE | ID: mdl-34199132

ABSTRACT

Fabry disease (FD) is a progressive multisystemic lysosomal storage disease. Early diagnosis by newborn screening (NBS) may allow for timely treatment, thus preventing future irreversible organ damage. We present the results of 5.5 years of NBS for FD by α-galactosidase A activity and globotriaosylsphingosine (lyso-Gb3) assays in dried blood spot through a multiplexed MS/MS assay. Furthermore, we report our experience with long-term follow-up of positive subjects. We screened more than 170,000 newborns and 22 males were confirmed to have a GLA gene variant, with an incidence of 1:7879 newborns. All patients were diagnosed with a variant previously associated with the later-onset phenotype of FD or carried an unclassified variant (four patients) or the likely benign p.Ala143Thr variant. All were asymptomatic at the last visit. Although lyso-Gb3 is not considered a reliable second tier test for newborn screening, it can simplify the screening algorithm when its levels are elevated at birth. After birth, plasma lyso-Gb3 is a useful marker for non-invasive monitoring of all positive patients. Our study is the largest reported to date in Europe, and presents data from long-term NBS for FD that reveals the current incidence of FD in northeastern Italy. Our follow-up data describe the early disease course and the trend of plasma lyso-Gb3 during early childhood.


Subject(s)
Dried Blood Spot Testing/methods , Fabry Disease/blood , Fabry Disease/diagnosis , Neonatal Screening/methods , alpha-Galactosidase/blood , Dried Blood Spot Testing/trends , Fabry Disease/epidemiology , Female , Follow-Up Studies , Glycolipids/blood , Humans , Infant, Newborn , Italy/epidemiology , Male , Neonatal Screening/trends , Sphingolipids/blood , Time Factors
9.
Orphanet J Rare Dis ; 16(1): 195, 2021 04 30.
Article in English | MEDLINE | ID: mdl-33931066

ABSTRACT

BACKGROUND: Alteration of vitamin B12 metabolism can be genetic or acquired, and can result in anemia, failure to thrive, developmental regression and even irreversible neurologic damage. Therefore, early diagnosis and intervention is critical. Most of the neonatal cases with acquired vitamin B12 deficiency have been detected by clinical symptoms and only few of them trough NBS programs. We aim to assess the usefulness of the second-tier test: methylmalonic acid (MMA), methylcitric acid (MCA) and homocysteine (Hcys) in our newborn screening program and explore the implications on the detection of cobalamin (vitamin B12) related disorders, both genetic and acquired conditions. METHODS: A screening strategy using the usual primary markers followed by the analysis of MMA, MCA and Hcys as second tier-test in the first dried blood spot (DBS) was developed and evaluated. RESULTS: During the period 2015-2018 a total of 258,637 newborns were screened resulting in 130 newborns with acquired vitamin B12 deficiency (incidence 1:1989), 19 with genetic disorders (incidence 1:13,613) and 13 were false positive. No false negatives were notified. Concerning the second-tier test, the percentage of cases with MMA above the cut-off levels, both for genetic and acquired conditions was very similar (58% and 60%, respectively). Interestingly, the percentage of cases with increased levels of Hcys was higher in acquired conditions than in genetic disorders (87% and 47%, respectively). In contrast, MCA was high only in 5% of the acquired conditions versus in 53% of the genetic disorders, and it was always very high in all patients with propionic acidemia. CONCLUSIONS: When screening for methylmalonic acidemia and homocystinuria, differential diagnosis with acquired vitamin B12 deficiency should be done. The results of our strategy support the inclusion of this acquired condition in the NBS programs, as it is easily detectable and allows the adoption of corrective measures to avoid the consequences of its deficiency.


Subject(s)
Propionic Acidemia , Vitamin B 12 Deficiency , Homocysteine , Humans , Infant, Newborn , Methylmalonic Acid , Neonatal Screening , Vitamin B 12 , Vitamin B 12 Deficiency/diagnosis , Vitamin B 12 Deficiency/genetics , Vitamins
10.
J. inborn errors metab. screen ; 9: e20210005, 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1287013

ABSTRACT

Abstract Elevation of branched-chain amino acids (BCAAs) in biological fluids indicates a deficiency in the branched-chain ketoacid dehydrogenase complex, which causes maple syrup urine disease (MSUD). Detection of increased levels of alloisoleucine confirms the diagnosis, while routine monitoring of leucine concentration is crucial for preventing metabolic decompensation and neurological dysfunction. In the metabolic center at Universidad de Chile, we have confirmed and monitored more than fifty MSUD patients in the last 20 years. Most diagnoses were made by clinical and sibling diagnosis, as MSUD is not included in the Chilean national newborn screening program. Shortening diagnosis time has a fundamental impact on the outcome of patients, therefore we focused on implementing detection of BCAAs in dried blood spot by liquid chromatography mass spectrometry (LC-MSMS) for disease confirmation as well as for biochemical monitoring. Retrospective analysis of samples from 9 diagnosed MSUD patients were performed; BCAAs values were determined via MSMS and LC-MSMS conducted in parallel. Leucine and alloisoleucine levels were positively correlated with patient's diagnosis age. Alloisoleucine was significatively elevated as early as 24 hr after birth. A predictable variation in BCAAs levels after nutritional intervention among diagnosed MSUD patients was found.

11.
Rev Esp Salud Publica ; 942020 Dec 16.
Article in Spanish | MEDLINE | ID: mdl-33323922

ABSTRACT

OBJECTIVE: Newborn screening programmes (NBSP) have experienced a qualitative breakthrough due to the implementation of tandem mass spectrometry. However, the tests used give rise to false positives (FP) generating an excessive request for second samples with the consequent anxiety of the families. In order to avoid this problem several programmes have developed second-tier tests (2TT). METHODS: This article presents our experience in the implementation of 2TT in the NBSP of Catalonia, as well as in other international programmes. RESULTS: From 2004 to the present, 2TT tests have been developed for more than 30 diseases. The use of 2TT helps to decrease the FP rate and increase the positive predictive value (PPV). In the NBSP of Catalonia, the implementation of 2TT for the detection of methylmalonic and propionic acidemias, homocystinurias, maple syrup disease and citrulinaemia, has managed to increase the PPV to 95% and decrease the PF rate to less than 0.01%. In cystic fibrosis, the application of 2TT slightly increases PPV but with a significant decrease in the request for second samples and in the number of cases referred to clinical units. CONCLUSIONS: The introduction of 2TT in the NBSP allows to reduce considerably the FP, decreases the number of requested samples, as well as both anxiety and stress of the families, at the same time that the hospital costs are reduced and the PPV is increased, improving notably the efficiency of the NBSP.


OBJETIVO: Los programas de cribado neonatal (PCN) han experimentado un gran avance cualitativo debido a la implementación de la espectrometría de masas en tándem. Sin embargo, las pruebas utilizadas dan lugar a falsos positivos (FP) generando una excesiva solicitud de segundas muestras con la consiguiente ansiedad de las familias. Con el fin de evitar este problema diversos programas han desarrollado pruebas de segundo nivel (2TT). METODOS: En este artículo se presenta nuestra experiencia en la implementación de 2TT en el PCN de Cataluña, así como en otros programas internacionales. RESULTADOS: Desde el año 2004 hasta la actualidad se han desarrollado pruebas de 2TT para más de 30 enfermedades. La utilización de 2TT ayuda a disminuir la tasa de FP y aumentar el valor predictivo positivo (VPP). En el PCN de Cataluña, la implementación de 2TT para la detección de acidemias metilmalónicas y propiónica, homocistinurias, jarabe de arce y citrulinemia, ha conseguido aumentar el VPP a un 95% y disminuir la tasa de FP a menos del 0,01%. En la fibrosis quística la aplicación de 2TT aumenta ligeramente el VPP pero con disminución significativa de la solicitud de segundas muestras y de los casos referidos a las unidades clínicas. CONCLUSIONES: La introducción de los 2TT en los PCN permite reducir considerablemente los FP, disminuye el número de muestras solicitadas, así como la ansiedad y el estrés de las familias, a la vez que se reducen los costes hospitalarios y se aumenta el VPP, mejorando notablemente la eficiencia de los PCN.


Subject(s)
Cystic Fibrosis/diagnosis , Metabolism, Inborn Errors/diagnosis , Neonatal Screening/methods , Severe Combined Immunodeficiency/diagnosis , Tandem Mass Spectrometry/methods , Anxiety/etiology , Anxiety/prevention & control , Biomarkers/blood , Cystic Fibrosis/blood , False Positive Reactions , Family/psychology , Humans , Infant, Newborn , International Cooperation , Metabolism, Inborn Errors/blood , Neonatal Screening/psychology , Reproducibility of Results , Sensitivity and Specificity , Severe Combined Immunodeficiency/blood , Spain , Stress, Psychological/etiology , Stress, Psychological/prevention & control
12.
Int J Neonatal Screen ; 6(4)2020 Nov 02.
Article in English | MEDLINE | ID: mdl-33147868

ABSTRACT

The expansion of national newborn screening (NBS) programmes has provided significant benefits in the diagnosis and early treatment of several rare, heritable conditions, preventing adverse health outcomes for most affected infants. New technological developments have enabled the implementation of testing panel covering over 50 disorders. Consequently, the increment of false positive rate has led to a high number of healthy infants recalled for expensive and often invasive additional testing, opening a debate about the harm-benefit ratio of the expanded newborn screening. The false-positive rate represents a challenge for healthcare providers working in NBS systems. Here, we give an overview on the most commonly used strategies for decreasing the adverse effects due to inconclusive screening results. The focus is on NBS performance improvement through the implementation of analytical methods, the application of new and more informative biomarkers, and by using post-analytical interpretive tools. These strategies, used as part of the NBS process, can to enhance the positive predictive value of the test and reduce the parental anxiety and healthcare costs related to the unnecessary tests and procedures.

13.
Int J Neonatal Screen ; 6(4)2020 Nov 02.
Article in English | MEDLINE | ID: mdl-33147872

ABSTRACT

Mucopolysaccharidosis type I (MPS I) is a progressive lysosomal storage disease, with neurological and visceral involvement, in which early diagnosis through newborn screening (NBS) and early treatment can improve outcomes. We present our first 5 years of experience with laboratory and clinical management of NBS for MPS I. Since 2015, we have screened 160,011 newborns by measuring α-L-iduronidase (IDUA) activity and, since 2019, glycosaminoglycans (GAGs) in dried blood spot (DBS) as a second-tier test. Positive screening patients were referred to our clinic for confirmatory clinical and molecular testing. We found two patients affected by MPS I (incidence of 1:80,005). Before the introduction of second-tier testing, we found a high rate of false-positives due to pseudodeficiency. With GAG analysis in DBS as a second-tier test, no false-positive newborns were referred to our clinic. The confirmed patients were early treated with enzyme replacement therapy and bone-marrow transplantation. For both, the clinical outcome of the disease is in the normal range. Our experience confirms that NBS for MPS I is feasible and effective, along with the need to include GAG assay as a second-tier test. Follow-up of the two positive cases identified confirms the importance of early diagnosis through NBS and early treatment to improve the outcome of these patients.

14.
Int J Neonatal Screen ; 6(2): 33, 2020 Jun.
Article in English | MEDLINE | ID: mdl-33073028

ABSTRACT

The expansion of the recommend uniform screening panel to include more than 50 primary and secondary target conditions has resulted in a substantial increase of false positive results. As an alternative to subjective manipulation of cutoff values and overutilization of molecular testing, here we describe the performance outcome of an algorithm for disorders of methionine, cobalamin, and propionate metabolism that includes: (1) first tier screening inclusive of the broadest available spectrum of markers measured by tandem mass spectrometry; (2) integration of all results into a score of likelihood of disease for each target condition calculated by post-analytical interpretive tools created byCollaborative Laboratory Integrated Reports (CLIR), a multivariate pattern recognition software; and (3) further evaluation of abnormal scores by a second tier test measuring homocysteine, methylmalonic acid, and methylcitric acid. This approach can consistently reduce false positive rates to a <0.01% level, which is the threshold of precision newborn screening. We postulate that broader adoption of this algorithm could lead to substantial savings in health care expenditures. More importantly, it could prevent the stress and anxiety experienced by many families when faced with an abnormal newborn screening result that is later resolved as a false positive outcome.

15.
Clin Chem Lab Med ; 58(12): 2063-2072, 2020 11 26.
Article in English | MEDLINE | ID: mdl-32432561

ABSTRACT

Objectives Mucopolysaccharidosis type I (MPS I) was added to our expanded screening panel in 2015. Since then, 127,869 newborns were screened by measuring α-L-iduronidase (IDUA) enzyme activity with liquid chromatography tandem mass spectrometry (LC-MS/MS). High false positives due to frequent pseudodeficiency alleles prompted us to develop a second-tier test to quantify glycosaminoglycan (GAG) levels in dried blood spot (DBS). Methods Heparan-sulfate (HS) and dermatan-sulfate (DS) were measured with LC-MS/MS after methanolysis. DBSs were incubated with methanolic-HCl 3 N at 65 °C for 45 min. Chromatographic separation used an amide column with a gradient of acetonitrile and water with 10 mM ammonium acetate in a 9-min run. The method was validated for specificity, linearity, lower limit of quantification (LOQ), accuracy and precision. Results Intra- and inter-day coefficients of variation were <15% for both metabolites. Reference values in 40 healthy newborns were: HS mean 1.0 mg/L, 0-3.2; DS mean 1.5 mg/L, 0.5-2.7). The two confirmed newborn MPS I patients had elevated HS (4.9-10.4 mg/L, n.v. <3.2) and DS (7.4-8.8 mg/L, n.v. <2.7). Since its introduction in February 2019, the second-tier test reduced the recall rate from 0.046% to 0.006%. Among 127,869 specimens screened, the incidence was 1:63,935 live births. Both patients started enzyme replacement therapy (ERT) within 15 days of birth and one of them received allogenic hematopoietic stem cell transplantation (HSCT) at ht age of 6 months. Conclusions GAGs in DBS increased the specificity of newborn screening for MPS I by reducing false-positives due to heterozygosity or pseudodeficiency. Early diagnosis and therapeutical approach has improved the outcome of our patients with MPS I.


Subject(s)
Glycosaminoglycans/analysis , Iduronidase/analysis , Mucopolysaccharidosis I/diagnosis , Chromatography, Liquid/methods , Glycosaminoglycans/blood , Humans , Iduronidase/blood , Infant, Newborn , Mucopolysaccharidosis I/blood , Neonatal Screening/methods , Reference Values , Tandem Mass Spectrometry/methods
16.
Int J Neonatal Screen ; 5(2): 24, 2019 Jun.
Article in English | MEDLINE | ID: mdl-33072983

ABSTRACT

The increasing availability of treatments and the importance of early intervention have stimulated interest in newborn screening for lysosomal storage diseases. Since 2015, 112,446 newborns in North Eastern Italy have been screened for four lysosomal disorders-mucopolysaccharidosis type I and Pompe, Fabry and Gaucher diseases-using a multiplexed tandem mass spectrometry (MS/MS) assay system. We recalled 138 neonates (0.12%) for collection of a second dried blood spot. Low activity was confirmed in 62 (0.06%), who underwent confirmatory testing. Twenty-five neonates (0.02%) were true positive: eight with Pompe disease; seven with Gaucher disease; eight with Fabry disease; and two with Mucopolysaccharidosis type I. The combined incidence of the four disorders was 1 in 4497 births. Except for Pompe disease, a second-tier test was implemented. We conclude that newborn screening for multiple lysosomal storage diseases combined with a second-tier test can largely eliminate false-positives and achieve rapid diagnosis.

17.
Genet Med ; 20(8): 840-846, 2018 08.
Article in English | MEDLINE | ID: mdl-29095812

ABSTRACT

PURPOSE: To describe a novel biochemical marker in dried blood spots suitable to improve the specificity of newborn screening for Pompe disease. METHODS: The new marker is a ratio calculated between the creatine/creatinine (Cre/Crn) ratio as the numerator and the activity of acid α-glucosidase (GAA) as the denominator. Using Collaborative Laboratory Integrated Reports (CLIR), the new marker was incorporated in a dual scatter plot that can achieve almost complete segregation between Pompe disease and false-positive cases. RESULTS: The (Cre/Crn)/GAA ratio was measured in residual dried blood spots of five Pompe cases and was found to be elevated (range 4.41-13.26; 99%ile of neonatal controls: 1.10). Verification was by analysis of 39 blinded specimens that included 10 controls, 24 samples with a definitive classification (16 Pompe, 8 false positives), and 5 with genotypes of uncertain significance. The CLIR tool showed 100% concordance of classification for the 24 known cases. Of the remaining five cases, three p.V222M homozygotes, a benign variant, were classified by CLIR as false positives; two with genotypes of unknown significance, one likely informative, were categorized as Pompe disease. CONCLUSION: The CLIR tool inclusive of the new ratio could have prevented at least 12 of 13 (92%) false-positive outcomes.


Subject(s)
Glycogen Storage Disease Type II/diagnosis , Neonatal Screening/methods , Algorithms , Biomarkers/blood , Creatine/analysis , Creatine/blood , Creatinine/analysis , Creatinine/blood , Dried Blood Spot Testing/methods , Glycogen Storage Disease Type II/blood , Humans , Infant, Newborn , Sensitivity and Specificity , alpha-Glucosidases/analysis , alpha-Glucosidases/blood
18.
J. inborn errors metab. screen ; 4: e160012, 2016. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1090916

ABSTRACT

Abstract The isodecyl neopentanoate is an ingredient used in the cosmetic industry to prepare a nipple fissure balm. We report on 12 newborns that showed elevated C5-acylcarnitine levels upon newborn screening following treatment with balm. The first 3 neonates were immediately recalled for confirmatory tests and resulted negative for both isovaleric acidemia and short/branched chain acyl-CoA dehydrogenase deficiency. In the other 9 cases, the immediate recall was avoided by applying a new second-tier test able to confirm the presence of pivaloylcarnitine. The concentration of C5-acylcarnitine was measured in the days following the suspension of balm application. Abnormal concentrations of C5-acylcarnitine did not seem to be associated with free carnitine deficiency, probably due to the short time of exposure. A direct correlation between balm ingestion and the elevation in pivaloylcarnitine has been demonstrated in 10 adult volunteers. The commercial balm containing a pivalic acid derivative is causal of false-positive results during newborn screening, and it could have the potential to cause secondary carnitine deficiency when used chronically.

19.
J Pharm Biomed Anal ; 88: 201-6, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24076575

ABSTRACT

Severe combined immunodeficiency due to adenosine-deaminase defect (ADA-SCID) is usually deadly in childhood because of severe recurrent infections. When clinical diagnosis is done, permanent damages due to infections or metabolite accumulation are often present. Gene therapy, bone marrow transplantation or enzyme replacement therapy may be effective if started early. The aim of this study was to set-up a robust method suitable for screening with a minimized preparation process and with inexpensive running costs, for diagnosing ADA-SCID by tandem mass spectrometry. ADA-SCID satisfies all the criteria for inclusion in a newborn screening program. We describe a protocol revised to incorporate adenosine and 2-deoxyadenosine testing into an expanded newborn screening program. We assessed the effectiveness of this approach testing dried blood spots from 4 genetically confirmed early-onset and 5 delayed-onset ADA-SCID patients. Reference values were established on 50,000 healthy newborns (deoxyadenosine <0.09µmol/L, adenosine <1.61µmol/L). We also developed a second tier test to distinguish true positives from false positives and improve the positive predictive value of an initial abnormal result. In the first 18 months, the pilot project has identified a newborn with a genetically confirmed defect in adenosine deaminase (ADA) gene. The results show that the method having great simplicity, low cost and low process preparations can be fully applicable to a mass screening program.


Subject(s)
Adenosine Deaminase/blood , Dried Blood Spot Testing , Neonatal Screening/methods , Severe Combined Immunodeficiency/blood , Tandem Mass Spectrometry , Calibration , Humans , Infant, Newborn , Pilot Projects , Predictive Value of Tests , Reference Values , Reproducibility of Results , Retrospective Studies , Severe Combined Immunodeficiency/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL