Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters








Database
Language
Publication year range
1.
J Clin Neurosci ; 125: 152-158, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38815301

ABSTRACT

BACKGROUND: The pathogenesis of postoperative complications in patients with osteoporotic vertebral compressive fractures (OVCFs) undergoing percutaneous vertebroplasty (PVP) is multifaceted, with local biomechanical deterioration playing a pivotal role. Specifically, the disparity in stiffness between the bone cement and osteoporotic cancellous bone can precipitate interfacial stress concentrations, potentially leading to cement-augmented vertebral body collapse and clinical symptom recurrence. This study focuses on the biomechanical implications of the space between the bone cement and bony endplate (BEP), hypothesizing that this interface may be a critical locus for stress concentration and subsequent vertebral failure. METHODS: Leveraging a validated numerical model from our previous study, we examined the biomechanical impact of the cement-BEP interface in the L2 vertebral body post-PVP, simulated OVCF and PVP and constructed three distinct models: one with direct bone cement contact with both cranial and caudal BEPs, one with contact only with the caudal BEPs and one without contact with either BEP. Moreover, we assessed stress distribution across cranial and caudal BEPs under various loading conditions to describe the biomechanical outcomes associated with each model. RESULTS: A consistent trend was observed across all models: the interfaces between the bone cement and cancellous bone exhibited higher stress values under the majority of loading conditions compared to models with direct cement-BEP contact. The most significant difference was observed in the flexion loading condition compared to the mode with direct contact between BEP and cement. The maximum stress in models without direct contact increased by at least 30%. CONCLUSIONS: Our study reveals the biomechanical significance of interfacial stiffness differences at the cement-BEP junction, which can exacerbate local stress concentrations and predispose to augmented vertebral collapse. We recommend the strategic distribution of bone cement to encompass a broader contact area with the BEP for preventing biomechanical failure and subsequent vertebral collapse.


Subject(s)
Bone Cements , Computer Simulation , Fractures, Compression , Spinal Fractures , Vertebroplasty , Humans , Bone Cements/adverse effects , Spinal Fractures/surgery , Biomechanical Phenomena/physiology , Fractures, Compression/surgery , Vertebroplasty/adverse effects , Vertebroplasty/methods , Osteoporotic Fractures/surgery , Lumbar Vertebrae/surgery , Finite Element Analysis , Stress, Mechanical , Postoperative Complications/epidemiology , Postoperative Complications/etiology
2.
Sensors (Basel) ; 16(4): 468, 2016 Apr 02.
Article in English | MEDLINE | ID: mdl-27049385

ABSTRACT

In this paper, a new micromachined tuning fork gyroscope (TFG) with an anchored diamond coupling mechanism is proposed while the mode ordering and the vibration sensitivity are also investigated. The sense-mode of the proposed TFG was optimized through use of an anchored diamond coupling spring, which enables the in-phase mode frequency to be 108.3% higher than the anti-phase one. The frequencies of the in- and anti-phase modes in the sense direction are 9799.6 Hz and 4705.3 Hz, respectively. The analytical solutions illustrate that the stiffness difference ratio of the in- and anti-phase modes is inversely proportional to the output induced by the vibration from the sense direction. Additionally, FEM simulations demonstrate that the stiffness difference ratio of the anchored diamond coupling TFG is 16.08 times larger than the direct coupling one while the vibration output is reduced by 94.1%. Consequently, the proposed new anchored diamond coupling TFG can structurally increase the stiffness difference ratio to improve the mode ordering and considerably reduce the vibration sensitivity without sacrificing the scale factor.

SELECTION OF CITATIONS
SEARCH DETAIL