Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.035
Filter
4.
Front Cardiovasc Med ; 11: 1410594, 2024.
Article in English | MEDLINE | ID: mdl-39006165

ABSTRACT

Transesophageal Echocardiography (TEE) is an important imaging method for the evaluation of cardiac structure and function, and it holds significant value in the clinical management of cardiovascular diseases. Unlike transthoracic echocardiography (TTE), which is non-invasive, TEE involves semi-invasive intracavity operations, leading to increasing attention to its safety and potential complications. Especially with the increasing demand for TEE applications in clinical practice and the rapid growth in the number of facilities utilizing it, the standardized application and safe operation of TEE technology have become particularly crucial. This article will review the literature and draw upon personal experience to analyze the complications and safety of TEE examinations from a technical perspective.

5.
Diagnostics (Basel) ; 14(13)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-39001245

ABSTRACT

Infective endocarditis is a rare disease with an increasing incidence and an unaltered high mortality rate, despite medical development. Imaging plays an integrative part in the diagnosis of infective endocarditis, with echocardiography as the initial diagnostic test. Research data in the utility of cardiac computed tomography (CCT) in the diagnostic algorithm of IE are rising, which indicates its importance in detection of IE-related lesion along with the exclusion of coronary artery disease. The latest 2023 European Society of Cardiology Guidelines in the management of IE classified CCT as class of recommendation I and level of evidence B in detection of both valvular and paravalvular lesions in native and prosthetic valve endocarditis. This review article provides a comprehensive and contemporary review of the role of CCT in the diagnosis of IE, the optimization of acquisition protocols, the morphology characteristics of IE-related lesions, the published data of the diagnostic performance of CCT in comparison to echocardiography as the state-of-art method, as well as the limitations and future possibilities.

6.
Diagnostics (Basel) ; 14(13)2024 Jul 05.
Article in English | MEDLINE | ID: mdl-39001329

ABSTRACT

BACKGROUND: Yeo's index is a novel measure of the severity of rheumatic mitral valve stenosis (MS). It is derived from the product of the mitral leaflet separation index and dimensionless index. This study aims to validate Yeo's index using a transesophageal echocardiogram (TEE) three-dimensional (3D) mitral valve area (MVA) as a comparator and to compare the concordance of existing echocardiographic measures of the MVA with TEE 3DMVA. METHODS AND RESULTS: We studied 111 patients with rheumatic MS who underwent both transthoracic echocardiography (TTE) and a TEE assessment of MS severity. Yeo's index, the MVA determined by 2D planimetry, pressure half-time (PHT) and continuity equation (CE) measured on TTE were compared with the TEE 3DMVA. With a linear correlation, Yeo's index showed the best correlation with TEE 3DMVA (r2 = 0.775), followed by 2D planimetry (r2 = 0.687), CE (r2 = 0.598) and PHT (r2 = 0.363). Using TEE 3DMVA as comparator, Yeo's index (ρc = 0.739) demonstrated the best concordance, followed by 2D planimetry (ρc = 0.632), CE (ρc = 0.464) and PHT (ρc = 0.366). When both Yeo's index and 2D planimetry suggested significant MS, the positive predictive value was high (an AUC of 0.966 and a PPV of 100.00% for severe MS, and an AUC of 0.864 and a PPV of 85.71% for very severe MS). When both measures suggested the absence of significant MS, the negative predictive value was also high (an AUC of 0.940 and an NPV of 88.90% for severe MS, and an AUC of 0.831 and an NPV of 88.71% for very severe MS). CONCLUSIONS: Yeo's index performed well in identifying severe MS when compared with TEE 3DMVA and may be a useful adjunct to existing methods of measuring MS severity. Combining it with 2D planimetry could further enhance its accuracy.

8.
Cureus ; 16(6): e61872, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38975408

ABSTRACT

Acute aortic dissection is a life-threatening condition. Myocardial ischemia associated with dissection occurs due to direct extension into the coronary artery or indirect involvement of the coronary ostia secondary to the dissection flap. Thus, the surgical procedure may require coronary reconstruction, in addition to aortic replacement. We experienced a case in which coronary artery reconstruction could be avoided because intraoperative transesophageal echocardiography showed that the aortic flap did not obstruct the right coronary artery in systole, and pulsed Doppler imaging indicated that there was sufficient coronary blood flow. This case shows that it is critical to establish a correct and early diagnosis and to proceed with the appropriate treatment for patients with myocardial ischemia.

9.
Clin Case Rep ; 12(7): e9143, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38962457

ABSTRACT

Septal occluder devices can be used with palliative intent to close tracheoesophageal fistulas and improve the quality of life of patients.

10.
Article in English | MEDLINE | ID: mdl-38970594

ABSTRACT

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

12.
Cureus ; 16(5): e60677, 2024 May.
Article in English | MEDLINE | ID: mdl-38903337

ABSTRACT

The Gerbode defect is a rare ventricular septal defect (VSD) between the left ventricle (LV) and right atrium (RA). We describe a challenging case of a rare acquired Gerbode defect from infective endocarditis. A 73-year-old male presented for left lower extremity edema and shortness of breath with exertion. He was discharged from the hospital one week prior after being diagnosed with right hip septic arthritis. A transthoracic echocardiogram (TTE) did not demonstrate an abscess or vegetation, but was significant for severely elevated tricuspid regurgitation velocity and pulmonary artery (PA) systolic pressure of 70 mm Hg without structural changes to the right ventricle or RA. A transesophageal echocardiogram (TEE) was performed due to these abnormal values and demonstrated a VSD between the LV and RA. This type of defect is known as a Gerbode defect, which is suggestive of an aortic root abscess. The patient ultimately was transferred to a tertiary care center, and the Gerbode defect with aortic root abscess was confirmed by direct visualization. This case reports a unique case of an acquired Gerbode defect secondary to infective endocarditis. Our patient's defect was noted to be above the tricuspid valve, which essentially confirmed the etiology as a VSD. Although the TEE did not demonstrate a clear aortic root abscess, direct visualization during the surgical intervention confirmed this suspicion. Prompt diagnosis of the Gerbode defect allowed the patient to receive urgent surgical intervention. Gerbode defects are rare but clinically important complications of infective endocarditis. This case highlights the importance of maintaining a high level of suspicion, especially if the values obtained during TTE do not fully explain a patient's clinical presentation. A high level of suspicion leading to a timely diagnosis of this condition is essential in preventing further valvular destruction and allowing prompt surgical intervention.

14.
Diagnostics (Basel) ; 14(11)2024 May 24.
Article in English | MEDLINE | ID: mdl-38893620

ABSTRACT

BACKGROUND AND OBJECTIVES: Transesophageal echocardiography (TEE) is considered an indispensable tool for perioperative evaluation in mitral valve (MV) surgery. TEE is routinely performed by anesthesiologists competent in TEE; however, in certain situations, the expertise of a senior cardiologist specializing in TEE is required, which incurs additional costs. The purpose of this study is to determine the indications for specialized perioperative TEE based on its utility and the correlation between intraoperative TEE diagnoses and surgical findings, compared with routine TEE performed by an anesthesiologist. MATERIALS AND METHODS: We conducted a three-year prospective study involving 499 patients with MV disease undergoing cardiac surgery. Patients underwent intraoperative and early postoperative TEE and at least one other perioperative echocardiographic evaluation. A computer application was dedicated to calculating the utility of each type of specialized TEE indication depending on the type of MV disease and surgical intervention. RESULTS: The indications for performing specialized perioperative TEE identified in our study can be categorized into three groups: standard, relative, and uncertain. Standard indications for specialized intraoperative TEE included establishing the mechanism and severity of MR (mitral regurgitation), guiding MV valvuloplasty, diagnosing associated valvular lesions post MVR (mitral valve replacement), routine evaluations in triple-valve replacements, and identifying the causes of acute, intraoperative, life-threatening hemodynamic dysfunction. Early postoperative specialized TEE in the intensive care unit (ICU) is indicated for the suspicion of pericardial or pleural effusions, establishing the etiology of acute hemodynamic dysfunction, and assessing the severity of residual MR post valvuloplasty. CONCLUSIONS: Perioperative TEE in MV surgery can generally be performed by a trained anesthesiologist for standard measurements and evaluations. In certain cases, however, a specialized TEE examination by a trained senior cardiologist is necessary, as it is indirectly associated with a decrease in postoperative complications and early postoperative mortality rates, as well as an improvement in immediate and long-term prognoses. Also, for standard indications, the correlation between surgical and TEE diagnoses was superior when specialized TEE was used.

16.
Article in English | MEDLINE | ID: mdl-38890085

ABSTRACT

This article is the eighth in an annual series reviewing the research highlights of the year pertaining to the subspecialty of perioperative echocardiography for the Journal of Cardiothoracic and Vascular Anesthesia. The authors thank the editor-in-chief, Dr Kaplan, and the editorial board for the opportunity to continue this series. In most cases, these will be research articles targeted at the perioperative echocardiographic diagnosis and treatment of patients after cardiothoracic surgery; but in some cases, the articles will target the use of perioperative echocardiography in general.

17.
Article in English | MEDLINE | ID: mdl-38887842

ABSTRACT

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.

18.
J Clin Med ; 13(12)2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38930056

ABSTRACT

Given the high morbidity and mortality associated with cardiopulmonary arrest, there have been multiple trials aimed at better monitoring and augmenting coronary, cerebral, and systemic perfusion. This article aims to elucidate these interventions, first by detailing the physiology of cardiopulmonary resuscitation and the available tools for managing cardiopulmonary arrest, followed by an in-depth examination of the newest advances in the monitoring and delivery of advanced cardiac life support.

19.
J Cardiothorac Surg ; 19(1): 388, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38926775

ABSTRACT

BACKGROUND: Cardiac myxomas are the most common type of primary cardiac tumors in adults, but they can have variable features that make them difficult to diagnose. We report two cases of atrial myxoma with calcification or ossification, which are rare pathological subgroups of myxoma. CASE PRESENTATION: A 47-year-old woman and a 35-year-old man presented to our hospital with different symptoms. Both patients had a history of chronic diseases. Transthoracic and transesophageal echocardiography revealed a mass in the left or right atrium, respectively, with strong echogenicity and echogenic shadows. The masses were suspected to be malignant tumors with calcification or ossification. Contrast transthoracic echocardiography(cTEE) showed low blood supply within the lesions. The patients underwent surgical resection of the atrial mass, and the pathology confirmed myxoma with partial ossification or massive calcification. CONCLUSION: We report two rare cases of atrial myxoma with calcification or ossification and analyze their ultrasonographic features. Transthoracic echocardiography and cTEE can provide valuable information for the diagnosis and management of such mass. However, distinguishing calcification and ossification in myxoma from calcification in malignant tumors is challenging. More studies are needed to understand the pathogenesis and imaging characteristics of these myxoma variants.


Subject(s)
Calcinosis , Heart Atria , Heart Neoplasms , Myxoma , Ossification, Heterotopic , Humans , Myxoma/diagnosis , Myxoma/surgery , Myxoma/complications , Heart Neoplasms/diagnosis , Heart Neoplasms/surgery , Heart Neoplasms/complications , Heart Neoplasms/pathology , Heart Neoplasms/diagnostic imaging , Male , Middle Aged , Calcinosis/diagnostic imaging , Calcinosis/diagnosis , Calcinosis/surgery , Heart Atria/pathology , Heart Atria/diagnostic imaging , Female , Adult , Ossification, Heterotopic/diagnosis , Ossification, Heterotopic/complications , Ossification, Heterotopic/surgery , Echocardiography , Echocardiography, Transesophageal
20.
Biomedicines ; 12(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38927452

ABSTRACT

Pigs as laboratory animals are used in preclinical studies aimed at developing medical devices for cardiac surgery. The anatomy of the cardiovascular system of these animals has been well studied and acknowledged as suitable for use and the testing of new cardiovascular devices developed for humans. However, there are no morphometric characteristics of the aortic root and thoraco-abdominal part of porcine aorta. This can lead to difficulties in experimental surgery and even result in the death of experimental animals due to the mismatch in the size of the implantable devices. Thus, such information is essential to enhance the efficiency of surgical technologies used for eliminating aortic pathologies in their various sections. The purpose of our research is to study the anatomy of the aorta in mini pigs and to assess whether the size, age, and sex of the animals affect the size of the main structures in their aortas. In addition, we attempted to compare the results obtained by transesophageal echocardiography (TEE) and angiography. We studied 28 laboratory mini pigs, dividing them into three groups by body weight (40-70 kg, 71-90 kg, and 90 kg). We did not find any relationship between the external somatometric characteristics of the animals and the size of their aortas. Animals have individual anatomical variability in their cardiovascular systems, which means that they need to be examined in terms of preoperative planning by any available method-echocardiography, angiography, or multispiral computed tomography (CT).

SELECTION OF CITATIONS
SEARCH DETAIL