Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
SICOT J ; 10: 22, 2024.
Article in English | MEDLINE | ID: mdl-38819292

ABSTRACT

PURPOSE: Controversy exists on the best fixation for total knee arthroplasty (TKA). Non-cemented fixation has been theorized to improve patient outcomes and longevity of implantation but no study has focused on comparison between cemented or cementless posterior-stabilized implants despite being the most commonly or second most frequently utilized implant in most total knee replacement registries. METHODS: Inclusion criteria with observational and interventional papers, and review articles that focused on patients with cementless and cemented PS TKAs were used to analyze outcomes such as implant survivorship, complication, or revision rates. Using a combination of keywords, a systematic search was performed on Medline (PubMed), Embase, and Cochrane Library for Meta-Analysis. RESULTS: When using the specified criteria, only 8 studies were selected for full-text analysis and meta-analysis after eliminating screening duplicates, titles, and abstracts without full-text access. These eight studies contain 1652 patients, 693 in the non-cemented Group, and 959 in the cemented total knee prosthesis Group. The meta-analysis revealed the advantage of cementless fixation over cemented fixation in implant survivorship, with 0.6% and 2.6% of aseptic loosening in each Group. The cumulative survival at 12 years was 97.4% for the cementless Group and 89.2% for the cemented Group. The subgroup with a stem showed a positive outcome for cementless fixation over cemented fixation regarding implant survivorship. No differences between the cemented and cementless TKAs were observed in patient-reported outcomes, revision rates, or radiolucent line development. CONCLUSION: We observed comparable rates for cemented and cementless posterior-stabilized TKAs over a medium-term follow-up period.

2.
Arch Orthop Trauma Surg ; 144(5): 2317-2326, 2024 May.
Article in English | MEDLINE | ID: mdl-38642162

ABSTRACT

INTRODUCTION: The aim of this study was to compare the results of cementless bilateral total knee arthroplasty (TKA) between individuals in different obesity groups. MATERIALS AND METHODS: This was a retrospective cohort study. Patients with a body mass index (BMI) greater than 25 who underwent bilateral TKA for gonarthrosis between 2014 and 2020 and completed a minimum follow-up of 24 months were included. Age, sex, height, weight, BMI, operation time, length of stay, patient satisfaction, knee scores and complications were compared. Patients with missing data, who were followed for less than 24 months or had postoperative fractures around the knee were excluded. RESULTS: There was a significant difference between the groups in terms of operation time (Class III > overweight > Class II > Class I p < 0.001). There was a significant difference in complications between the groups (Class III > Class I > Class II > overweight p = 0.010). According to our pairwise comparison, complications were more common in the class III group than in the overweight group. Knee score (KS) and function score (FS) increased significantly after surgery in all groups (p < 0.001), with no difference in FS (p = 0.448). Knee score changes were greater in the overweight and class I groups (p < 0.001). There was a significant interaction between both KS and FS and person satisfaction (p < 0.001). CONCLUSION: Cementless TKA improved KS and FS in all obesity groups, yielded high patient satisfaction. Although the incidence of complications was higher in the morbidly obese patients than in the overweight patients, the difference was not significant. Patients with morbid obesity should be informed about related risks before planning cementless TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Body Mass Index , Humans , Arthroplasty, Replacement, Knee/methods , Male , Female , Retrospective Studies , Middle Aged , Aged , Postoperative Complications/epidemiology , Obesity/complications , Patient Satisfaction , Osteoarthritis, Knee/surgery , Treatment Outcome , Operative Time
3.
J Arthroplasty ; 39(9S2): S45-S53, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38458333

ABSTRACT

BACKGROUND: Total knee arthroplasty (TKA) is one of the most common procedures in orthopaedics, but there is still debate over the optimal fixation method for long-term durability: cement versus cementless bone ingrowth. Recent improvements in implant materials and technology have offered the possibility of cementless TKA to change clinical practice with durable, stable biological fixation of the implants, improved operative efficiency, and optimal long-term results, particularly in younger and more active patients. METHODS: This symposium evaluated the history of cementless TKA, the recent resurgence, and appropriate patient selection, as well as the historical and modern-generation outcomes of each implant (tibia, femur, and patella). Additionally, surgical technique pearls to assist in reliable, reproducible outcomes were detailed. RESULTS: Historically, cemented fixation has been the gold standard for TKA. However, cementless fixation is increasing in prevalence in the United States and globally, with equivalent or improved results demonstrated in appropriately selected patients. CONCLUSIONS: Cementless TKA provides durable biologic fixation and successful long-term results with improved operating room efficiency. Cementless TKA may be broadly utilized in appropriately selected patients, with intraoperative care taken to perform meticulous bone cuts to promote appropriate bony contact and biologic fixation.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Cements , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Knee Joint/surgery , Patient Selection , Prosthesis Design , Treatment Outcome , Congresses as Topic
4.
Cureus ; 15(4): e38259, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37252495

ABSTRACT

Background Although most TKR surgeries are cemented, the interest in cementless TKR has increased dramatically during the last few years because of the new generation of cementless prostheses and the increased number of young patients who need TKR. Methods Ten years of retrospective reviews of 80 patients who had cementless, complete rotating platform TKR (DePuy Synthes, Warsaw, Indiana) were performed. Patients were divided into two groups according to their age (above and below 70 years old). Functional outcomes at the final follow-up were evaluated clinically by filling out a satisfaction form, and the Oxford Knee Score as well as all medical and surgical complications were recorded for each patient. Results The 10-year cumulative implant survival rate was 100%, i.e. no patients had revision surgeries with no significant statistical difference between the two age groups. The 10-year evaluation rate was 90%. Conclusion The use of cementless TKA exhibited good survivability, long-term clinical and functional results, and no implant revision in various age groups, as well as a high satisfaction rate. There was no statistically significant difference between the results of different age groups.

5.
J Arthroplasty ; 38(10): 2131-2136, 2023 10.
Article in English | MEDLINE | ID: mdl-37142071

ABSTRACT

BACKGROUND: Despite renewed interest in cementless fixation of total knee implants, many surgeons have anecdotal concerns about slower recovery and higher early pain scores. We sought to analyze 90-day opioid utilizations, inhospital pain scores, and patient-reported outcome measures (PROMs) in patients undergoing primary cemented versus cementless total knee arthroplasty (TKA). METHODS: We retrospectively identified a cohort of opioid naïve patients undergoing primary TKA for osteoarthritis. There were 186 patients who had cementless TKAs matched 1:6 with 1,116 who received a cemented TKAs based on age (±6 years), body mass index (BMI) (±5), and sex. We compared inhospital pain scores, 90-day opioid utilizations in morphine milligram equivalents (MMEs), and early postoperative PROMs. RESULTS: The cemented and cementless cohorts had similar lowest (0.09 versus 0.08), highest (7.36 versus 7.34), and average (3.26 versus 3.27) pain scores using numeric rating scale (P > .05). They received similar inhospital (90 versus 102, P = .176), discharge (315 versus 315, P = .483), and total (687 versus 720, P = .547) MMEs. They had similar average inpatient hourly opioid consumption (2.5 versus 2.5 MMEs/hour, P = .965). Average refills 90 days postoperatively were similar in both cohorts (1.5 versus 1.4 refills, P = .893). Also, preoperative, 6-week, 3-month, delta 6-week, and delta 3-month PROMs scores were similar between cemented and cementless cohorts (P > .05) CONCLUSION: This matched study demonstrated similar in-hospital pain scores and opioid utilization, total MMEs prescribed within 90 days, and PROMs at 6 weeks and 3 months postoperatively between cemented and cementless TKAs. LEVEL OF EVIDENCE: III, retrospective cohort study.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Analgesics, Opioid/therapeutic use , Retrospective Studies , Inpatients , Pain
6.
J Arthroplasty ; 38(6S): S151-S156, 2023 06.
Article in English | MEDLINE | ID: mdl-36963531

ABSTRACT

BACKGROUND: With the use of newer biomaterials, many authors have reported similar results between cementless and cemented total knee arthroplasty (TKA). The purpose of this study was to compare the early clinical and radiographic outcomes of cementless and cemented TKA using the same dual-pivot articulation. METHODS: A consecutive series of 806 TKAs were implanted by a single surgeon using the same dual-pivot articulation. There were 634 TKAs (79%) cemented and 172 (21%) uncemented. One patient in the cementless group was lost before two years. The remaining 171 cementless TKAs were matched 1:1 with cemented TKAs with respect to age, sex, and body mass index. All patients were followed for a minimum of two years (range, 24-66 months) using the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement , and Knee Society clinical and radiographic evaluation. The average follow-up was 3.8 years (range, 24-66 months) in the cemented group and 3.4 years (range, 24-56 months) in the cementless group. RESULTS: At final follow-up, the average Knee Injury and Osteoarthritis Outcome Score for Joint Replacement was higher in the cementless group (86 points (range, 64-100) versus 80 points (range, 57-100). Postoperative Knee Society scores (including pain and function) were similar. There was one deep infection (cemented TKA). The manipulation rate was 1.2% in the cementless group and 2.4% in the cemented TKA group. Excluding infection, two knees (1.2%) were revised in each group. No cases of femoral or tibial component loosening were identified. CONCLUSION: Patients implanted with either a cemented or cementless TKA using the same conforming dual-pivot articulation design had similar early outcomes and functional improvements. The type of fixation did not appear to influence the early clinical results.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Follow-Up Studies , Bone Cements , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Treatment Outcome , Prosthesis Failure
7.
J Arthroplasty ; 38(6S): S131-S136, 2023 06.
Article in English | MEDLINE | ID: mdl-36791886

ABSTRACT

BACKGROUND: There is a renewed interest in uncemented total knee arthroplasty to potentially provide longer durability, including the use of newer design metal-backed patellae (MBPs). The purpose of this study was to review survivorship with failure mode and time to failure of an earlier version MBP at up to 10-30 years of follow-up that may influence the desirability of using these components today. METHODS: A retrospective review was performed of patients that had uncemented total knee arthroplasty with an uncemented MBP. All-cause revision rates were obtained from chart reviews and telephone discussions with patients and family members of deceased patients. Kaplan-Meier plots were used to determine the implant survivorship. Outcome scores were compared between revised and nonrevised patients. RESULTS: The 97 knees that had an end point of an aseptic revision or last known contact with implant survivorship averaged 15 years (range, 0-32 years). There were 40 knees that underwent revision that included 37 patella component failures (38.1%). All patellar failures had polyethylene wear or fracture. None were revised due to loosening. Survivorship was 97.9% at 5 years, 88.7% at 10 years, and 53.0% at 20 years. Median time to failure was 11 years. CONCLUSION: Loosening is not a failure mode with this MBP. There were 75% of the failures occurring after 10 years. Use of contemporary MBP with improved but still thin polyethylene warrants guarded optimism when used in younger patients where longer survivorship than with a cemented all-polyethylene patellar component is the goal.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Patella/surgery , Treatment Outcome , Polyethylene , Prosthesis Design , Reoperation , Metals , Prosthesis Failure , Follow-Up Studies
8.
J Arthroplasty ; 38(4): 691-699, 2023 04.
Article in English | MEDLINE | ID: mdl-36272510

ABSTRACT

BACKGROUND: Cementless total knee arthroplasty (TKA) is the subject of renewed interest. Previous concerns about survivorship have been addressed and there is an appeal in terms of biological fixation and surgical efficiency. However, even surgeon advocates have concerns about the risk of marked subsidence when using this technology in older patients at risk for osteoporosis. METHODS: This was a retrospective analysis of 1,000 consecutive fully cementless mobile bearing TKAs performed at a single institution on women over 75 years of age who had postoperative and 1-year x-rays. The primary outcome was the incidence of subsidence. RESULTS: There were three asymptomatic cases with definite subsidence and change in alignment. In a fourth symptomatic case, the femoral component subsided into varus and the tibia into valgus, thus maintaining alignment which facilitated nonoperative treatment in a 92-year-old. Overall, at 1 year, there were two- liner revisions for infection without recurrence. Five patients had further surgery, of which three were washouts and two were for periprosthetic fractures sustained postoperatively within 1 year. Seven patients had further anesthesia, of which five were manipulations and two were nonrecurrent closed reductions for spinouts. CONCLUSION: Cementless TKA did not have a high risk of subsidence in this at-risk population. In the hands of experienced surgeons, these procedures can be used safely irrespective of bone quality.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Female , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Retrospective Studies , Knee Prosthesis/adverse effects , Tibia/surgery , Radiography , Reoperation , Treatment Outcome
9.
J Arthroplasty ; 37(6S): S221-S225, 2022 06.
Article in English | MEDLINE | ID: mdl-35249788

ABSTRACT

BACKGROUND: Total knee arthroplasty (TKA) tibial baseplate thickness, metallurgy, and implant fixation with cement may influence stress shielding. The purpose of the present study is to compare bone mineral density of 2 cemented and press-fit TKA designs with differing tibial baseplate thicknesses and metallurgy over a 2-year period to assess for changes in stress shielding. METHODS: One-hundred one TKAs were performed in this Institutional Review Board-approved, prospective study. There were 4 cohorts: DePuy Attune cemented and press-fit, and Stryker Triathlon cemented and press-fit. The Attune tibial baseplate was thicker; both cemented tibial and femoral components were cobalt-chromium. The DePuy Attune press-fit had a cobalt-chromium sintered bead porous coating while the Stryker Triathlon was 3-dimensional printed highly porous titanium alloy. All patients had quantitative dual-energy X-ray absorptiometry scans performed at baseline (4-6 weeks postoperatively) and at 1 and 2 years postoperatively. Stress shielding was evaluated by comparing percent change in bone mineral density in 11 radiographic zones over 2 years. RESULTS: Over a 2-year period, there were no differences in stress shielding on the tibial side in either cemented or press-fit between Stryker Triathlon and DePuy Attune; however, there were differences on the femoral side. The press-fit tibial components of the Stryker Triathlon and DePuy Attune had either similar or less stress shielding over a 2-year period compared to their cemented counterparts. CONCLUSION: This study comparing 2 TKA implants with differing tibial tray thickness did not find significant differences in tibial stress shielding between designs. There was a difference in stress shielding on the femoral side between designs, suggesting that longer term follow-up is warranted.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Arthroplasty, Replacement, Knee/methods , Bone Cements , Chromium , Cobalt , Humans , Prospective Studies , Prosthesis Design , Tibia/surgery
10.
Bone Joint J ; 103-B(11): 1702-1708, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34719272

ABSTRACT

AIMS: Intra-articular administration of antibiotics during primary total knee arthroplasty (TKA) may represent a safe, cost-effective strategy to reduce the risk of acute periprosthetic joint infection (PJI). Vancomycin with an aminoglycoside provides antimicrobial cover for most organisms isolated from acute PJI after TKA. However, the intra-articular doses required to achieve sustained therapeutic intra-articular levels while remaining below toxic serum levels is unknown. The purpose of this study is to determine the intra-articular and serum levels of vancomycin and tobramycin over the first 24 hours postoperatively after intra-articular administration in primary cementless TKA. METHODS: A prospective cohort study was performed. Patients were excluded if they had poor renal function, known allergic reaction to vancomycin or tobramycin, received intravenous vancomycin, or were scheduled for same-day discharge. All patients received 600 mg tobramycin and 1 g of vancomycin powder suspended in 25 cc of normal saline and injected into the joint after closure of the arthrotomy. Serum from peripheral venous blood and drain fluid samples were collected at one, four, and 24 hours postoperatively. All concentrations are reported in µg per ml. RESULTS: A total of 22 patients were included in final analysis. At one, four, and 24 hours postoperatively, mean (95% confidence interval (CI)) serum concentrations were 2.4 (0.7 to 4.1), 5.0 (3.1 to 6.9), and 4.8 (2.8 to 6.9) for vancomycin and 4.9 (3.4 to 6.3), 7.0 (5.8 to 8.2), and 1.3 (0.8 to 1.8) for tobramycin; intra-articular concentrations were 1,900.6 (1,492.5 to 2,308.8), 717.9 (485.5 to 950.3), and 162.2 (20.5 to 304.0) for vancomycin and 2,105.3 (1,389.9 to 2,820.6), 403.2 (266.6 to 539.7), and 98.8 (0 to 206.5) for tobramycin. CONCLUSION: Intra-articular administration of 1 g of vancomycin and 600 mg of tobramycin as a solution after closure of the arthrotomy in primary cementless TKA achieves therapeutic intra-articular concentrations over the first 24 hours postoperatively and does not reach sustained toxic levels in peripheral blood. Cite this article: Bone Joint J 2021;103-B(11):1702-1708.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/blood , Arthroplasty, Replacement, Knee , Knee Prosthesis/adverse effects , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/prevention & control , Tobramycin/administration & dosage , Tobramycin/blood , Vancomycin/administration & dosage , Vancomycin/blood , Aged , Female , Humans , Injections, Intra-Articular , Injections, Intralesional , Male , Middle Aged , Prospective Studies
11.
J Arthroplasty ; 34(10): 2392-2397, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31178387

ABSTRACT

BACKGROUND: Patients between 45 and 54 years old will be the fastest-growing cohort seeking total knee arthroplasty (TKA) over the next 15 years. The purpose of this investigation is to determine the clinical outcomes of TKA in patients less than 50 years old at a minimum of 10 years. We hypothesized that this patient population would have a high rate of survivorship that is similar to that of older patients. METHODS: We reviewed 298 consecutive TKAs on 242 patients at a minimum of 10 years postoperatively. Twenty patients died and 30 TKAs were lost to follow-up leaving 248 TKAs in 202 patients (91 male, 111 female) with a mean age of 45.7 years (range, 26-49) at the time of surgery. Patient-reported outcomes, survivorship, causes of reoperation, and initial postoperative radiographic parameters were collected. RESULTS: At a mean of 13.0 years, there were 9 revisions for tibial loosening (3.6%), 8 for deep infection (3.2%), 7 for polyethylene wear (2.8%), and 3 for failed ingrowth of a cementless femoral component (1.2%). Kaplan-Meier analysis demonstrated 92.0% survivorship with failures defined as aseptic component revision and 83.9% survivorship for all-cause reoperation at 13 years. Patients with tibial alignment of 4° or more of varus or 10° or more of posterior slope were found to have increased rate of failure. CONCLUSION: While overall durability was good in this young patient population, tibial fixation and deep infection were relatively common causes of failure. In addition, increased tibial varus and slope were found to increase the rate of failure. Furthermore, the nearly 3% risk of revision for wear suggests that the use of more wear-resistant bearing surfaces may reduce the risk of failure in this patient population.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Adult , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Odds Ratio , Patient Reported Outcome Measures , Polyethylene , Postoperative Period , Prosthesis Design , Prosthesis Failure , Reoperation/adverse effects , Retrospective Studies , Risk , Tibia/physiology , Tibia/surgery
12.
Int Orthop ; 43(8): 1849-1857, 2019 08.
Article in English | MEDLINE | ID: mdl-30284003

ABSTRACT

INTRODUCTION: Using a cementless fixation for total knee arthroplasty (TKA) is controversial. We hypothesized that cementless tibial base plate with a monoblock long stem (MLS) would provide secure tibial alignment and stable fixation when bone conditions were considered as poor for a cementless fixation. The purpose of this study was to compare the mean eight year survivorship of cementless standard keels (SK) vs cementless MLS. MATERIAL METHODS: We report a matched series of 98 cases of SK and 98 cases of MLS in patients with poor bone conditions. The two cohorts were statistically compared. Revision for tibial loosening was used as the endpoint in the survivorship analysis. RESULTS: We recorded two cases of tibial loosening and three cases of bipolar loosening in the SK group (0% MLS vs 5% SK). No tibial loosening occurred in the MLS group (statistically significant). No tibial periprosthetic or intra-operative fractures occurred in either group. The survivorship at eight years of follow-up was 95.6% in the SS cohort vs 100% in the MLS cohort using revision for tibial loosening as the endpoint. DISCUSSION: This study was not randomized. Its strength was that it took into account the comparative midterm outcomes of a matched cohort of patients implanted with two types of cementless components in the same bone conditions. We did not record any tibial loosening in the MLS group. Using long stems has been criticized but we did not observe any adverse reactions and no intra-operative tibial fracture occurred. CONCLUSION: MLS improves the alignment and fixation of cementless TKA. This is a safe solution when bone conditions are poor or modified by previous surgery.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Cohort Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Reoperation , Tibia/surgery
13.
J Arthroplasty ; 33(12): 3672-3677, 2018 12.
Article in English | MEDLINE | ID: mdl-30077469

ABSTRACT

BACKGROUND: The cemented Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary knee kinematics data and has shown satisfactory long-term outcomes. METHODS: We retrospectively evaluated prospectively collected data from 2 groups of patients. Group A consisted of 54 patients (54 TKAs), 18 men and 36 women, and mean age at surgery was 63.2 ± 5.2 years; group B consisted of 54 patients (54 TKAs), 17 men and 37 women, and mean age at surgery was 63.8 ± 5.1 years. Patients of both groups were matched for age, gender, side, body mass index, and length of follow-up. The cementless components of this design were implanted in group A and the cemented in group B. Implant failure, complication rates, clinical (both subjective and objective) and radiological outcomes were assessed in all patients of both groups. RESULTS: All patients of both groups were available for final follow-up evaluation at a mean of 8.6 ± 0.4 years. Survival analysis at 9 years showed a cumulative success rate of 100% in both groups with all end points. In neither group were implant-related, surgeon-related, or patient-related failures observed. When both groups were compared, in all time intervals, no differences were recorded on Knee Society system, Western Ontario and McMaster University Osteoarthritis Index, Short Form-12, and Oxford Knee Scores. On radiological examination, for both groups, all parameters evaluated were satisfactory. CONCLUSION: This study presents satisfactory midterm clinical and radiological outcomes with the use of both versions of this design. Moreover, no implant-related failures were observed with the use of cancellous titanium-coated tibial implants.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Bone Cements , Knee Prosthesis/statistics & numerical data , Tibia/surgery , Aged , Female , Humans , Knee Joint/diagnostic imaging , Male , Middle Aged , Osteoarthritis, Knee/surgery , Radiography , Retrospective Studies , Titanium , Treatment Outcome
14.
Open Orthop J ; 12: 196-202, 2018.
Article in English | MEDLINE | ID: mdl-30008968

ABSTRACT

BACKGROUND: There is an ongoing debate about whether to use cementless or cemented fixation for Total Knee Arthroplasty (TKA). OBJECTIVE: The study aimed to assess midterm survivorship of the Vanguard cementless system, and to demonstrate the utility of the Bone Hardness Test (BHT) for the selection of cementless fixation TKA. METHODS: From September 2009 through November 2014, 123 total knee arthroplasties were completed, with cementless Vanguard Cruciate Retaining TKA in 110 knees (102 patients) and cemented Vanguard in 13 cases (12 patients). Implant fixation was based on intraoperative assessment of posterior cruciate ligament stability, bone quality, and BHT. All patients with a cementless Vanguard implant were eligible for this retrospective study. Preoperative and postoperative Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index were obtained. Standardized standing anteroposterior and lateral radiographs were taken. RESULTS: Three patients (4 TKAs) were lost to follow-up. The mean follow-up time was 5.5 ± 1.4 years. All scores significantly improved postoperatively. No radiographic failures were observed. Five-year implant survival, with revision of any component for any reason as an endpoint, was 97.2% (95% confidence interval, 91.7 - 99.1%). Five-year survival with revision for aseptic loosening was 100%. Only one knee required revision due to an isolated unrelated bearing exchange, and two additional knees required secondary resurfacing of the patella for retropatellar pain. CONCLUSION: Good midterm results were obtained with the cementless Vanguard Cruciate Retaining TKA for the treatment of osteoarthritis. The Bone Hardness Test appears to be an effective way to determine the selection of cementless TKA.

15.
Acta Orthop Traumatol Turc ; 51(6): 433-436, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29102502

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. METHODS: A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. RESULTS: The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. CONCLUSION: Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. LEVEL OF EVIDENCE: Level IV, Therapeutic study.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Screws , Durapatite/therapeutic use , Knee Joint , Knee Prosthesis , Long Term Adverse Effects , Reoperation , Adult , Aged , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Biocompatible Materials/therapeutic use , Female , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/physiopathology , Knee Joint/surgery , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/etiology , Long Term Adverse Effects/physiopathology , Long Term Adverse Effects/surgery , Male , Middle Aged , Outcome and Process Assessment, Health Care , Radiography/methods , Recovery of Function , Reoperation/methods , Reoperation/statistics & numerical data , Surgical Fixation Devices , Tibia/surgery , Turkey
16.
J Orthop Case Rep ; 7(1): 32-35, 2017.
Article in English | MEDLINE | ID: mdl-28630836

ABSTRACT

INTRODUCTION: Along with the increase of osteoporotic patients in an aging society, complications in surgeries associated with osteoporosis are also increasing. In cementless total knee arthroplasty (TKA), poor primary stability and subsequent initial loosening of the implant may be seen. CASE REPORT: The patient, a 75-year-old Asian woman with a history of osteoporosis, underwent cementless TKA. Knee radiography at 5 weeks postoperatively showed radiolucent lines outlined beneath the tibial tray and around the stem. The tibial component was considered unstable due to loosening. A 56.5 µg weekly dose of teriparatide (rh [1-34] parathyroid hormone) was administered. After 2 months of treatment, knee pain and knee swelling had disappeared. Tomosynthesis taken after 6 months of treatment confirmed complete ingrowth of the component to the bone. CONCLUSION: This case showed that a weekly teriparatide administration of 56.5 µg improved initial loosening of the tibial implant in cementless TKA. Administration of teriparatide in cases of the osteoporotic patient who has loosening in cementless TKA may be a useful adjuvant to achieve bone ingrowth again.

17.
Bone Joint J ; 98-B(7): 867-73, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27365463

ABSTRACT

As the number of younger and more active patients treated with total knee arthroplasty (TKA) continues to increase, consideration of better fixation as a means of improving implant longevity is required. Cemented TKA remains the reference standard with the largest body of evidence and the longest follow-up to support its use. However, cementless TKA, may offer the opportunity of a more bone-sparing procedure with long lasting biological fixation to the bone. We undertook a review of the literature examining advances of cementless TKA and the reported results. Cite this article: Bone Joint J 2016;98-B:867-73.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Humans , Patient Selection , Prosthesis Design , Prosthesis Failure
18.
Ann Transl Med ; 4(7): 129, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27162779

ABSTRACT

Interest for uncemented total knee arthroplasty (TKA) has greatly increased in recent years. This technique, less used than cemented knee replacement in the last decades, sees a revival thanks an advance in prosthetic design, instrumentation and operative technique. The related literature in some cases shows conflicting data on survival and on the revision's rate, but in most cases a success rate comparable to cemented TKA is reported. The optimal fixation in TKA is a subject of debate with the majority of surgeons favouring cemented fixation.

19.
J Arthroplasty ; 29(6): 1192-6, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24355257

ABSTRACT

A prospective matched cohort study was performed to compare outcomes of cementless total knee arthroplasties between 171 knees in obese patients (BMI ≥ 30) and 171 non-obese patients (BMI < 30). Mean follow-up was 7 years. There were no significant differences in overall functional outcomes or components alignment. In the obese group, there were 14 perioperative complications, 9 revisions, and 5 other patients were considered clinical failures, whereas in the non-obese group there were 3, 5, and 7, respectively. There were no significant differences between obese class I-II and class III (morbid) subgroups. The obese and non-obese groups had similar implant survivorship at 7 years. Although TKA outcome in obese was satisfactory, these patients should be informed of the perioperative risks, and advised to lose weight prior to surgery.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Obesity/complications , Osteoarthritis, Knee/surgery , Adult , Aged , Aged, 80 and over , Cementation , Cohort Studies , Female , Follow-Up Studies , Humans , Knee Prosthesis , Male , Middle Aged , Osteoarthritis, Knee/complications , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL