Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters








Database
Language
Publication year range
1.
Sensors (Basel) ; 23(21)2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37960370

ABSTRACT

Abnormalities of navigation buoys include tilting, rusting, breaking, etc. Realizing automatic extraction and evaluation of rust on buoys is of great significance for maritime supervision. Severe rust may cause damage to the buoy itself. Therefore, a lightweight method based on machine vision is proposed for extracting and evaluating the rust of the buoy. The method integrates image segmentation and processing. Firstly, image segmentation technology is used to extract the metal part of the buoy based on an improved U-Net. Secondly, the RGB image is converted into an HSV image by preprocessing, and the transformation law of HSV channel color value is analyzed to obtain the best segmentation threshold and then the pixels of the rusted and the metal parts can be extracted. Finally, the rust ratio of the buoy is calculated to evaluate the rust level of the buoy. Results show that both the segmentation precision and recall are above 0.95, and the accuracy is nearly 1.00. Compared with the rust evaluation algorithm directly using the image processing method, the accuracy and processing speed of rust grade evaluation are greatly improved.

2.
J Bone Oncol ; 42: 100498, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37670740

ABSTRACT

Objective: The objective of this study was to investigate the use of contrast-enhanced magnetic resonance imaging (CE-MRI) combined with radiomics and deep learning technology for the identification of spinal metastases and primary malignant spinal bone tumor. Methods: The region growing algorithm was utilized to segment the lesions, and two parameters were defined based on the region of interest (ROI). Deep learning algorithms were employed: improved U-Net, which utilized CE-MRI parameter maps as input, and used 10 layers of CE images as input. Inception-ResNet model was used to extract relevant features for disease identification and construct a diagnosis classifier. Results: The diagnostic accuracy of radiomics was 0.74, while the average diagnostic accuracy of improved U-Net was 0.98, respectively. the PA of our model is as high as 98.001%. The findings indicate that CE-MRI based radiomics and deep learning have the potential to assist in the differential diagnosis of spinal metastases and primary malignant spinal bone tumor. Conclusion: CE-MRI combined with radiomics and deep learning technology can potentially assist in the differential diagnosis of spinal metastases and primary malignant spinal bone tumor, providing a promising approach for clinical diagnosis.

3.
Healthcare (Basel) ; 10(12)2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36554021

ABSTRACT

Glaucoma is prominent in a variety of nations, with the United States and Europe being two of the most famous. Glaucoma now affects around 78 million people throughout the world (2020). By the year 2040, it is expected that there will be 111.8 million cases of glaucoma worldwide. In countries that are still building enough healthcare infrastructure to cope with glaucoma, the ailment is misdiagnosed nine times out of ten. To aid in the early diagnosis of glaucoma, the creation of a detection system is necessary. In this work, the researchers propose using a technology known as deep learning to identify and predict glaucoma before symptoms appear. The glaucoma dataset is used in this deep learning algorithm that has been proposed for analyzing glaucoma images. To get the required results when using deep learning principles for the job of segmenting the optic cup, pretrained transfer learning models are integrated with the U-Net architecture. For feature extraction, the DenseNet-201 deep convolution neural network (DCNN) is used. The DCNN approach is used to determine whether a person has glaucoma. The fundamental goal of this line of research is to recognize glaucoma in retinal fundus images, which will aid in assessing whether a patient has the condition. Because glaucoma can affect the model in both positive and negative ways, the model's outcome might be either positive or negative. Accuracy, precision, recall, specificity, the F-measure, and the F-score are some of the metrics used in the model evaluation process. An extra comparison study is performed as part of the process of establishing whether the suggested model is accurate. The findings are compared to convolution neural network classification methods based on deep learning. When used for training, the suggested model has an accuracy of 98.82 percent and an accuracy of 96.90 percent when used for testing. All assessments show that the new paradigm that has been proposed is more successful than the one that is currently in use.

4.
Materials (Basel) ; 15(13)2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35806543

ABSTRACT

Grain size is one of the most important parameters for metallographic microstructure analysis, which can partly determine the material performance. The measurement of grain size is based on accurate image segmentation methods, which include traditional image processing methods and emerging machine-learning-based methods. Unfortunately, traditional image processing methods can hardly segment grains correctly from metallographic images with low contrast and blurry boundaries. Moreover, the proposed machine-learning-based methods need a large dataset to train the model and can hardly deal with the segmentation challenge of complex images with fuzzy boundaries and complex structure. In this paper, an improved U-Net model is proposed to automatically accomplish image segmentation of complex metallographic images with only a small training set. The experiments on metallographic images show the significant advantage of the method, especially for the metallographic images with low contrast, a fuzzy boundary and complex structure. Compared with other deep learning methods, the improved U-Net scored higher in ACC, MIoU, Precision, and F1 indexes, among which ACC was 0.97, MIoU was 0.752, Precision was 0.98, and F1 was 0.96. The grain size was calculated based on the segmentation according to the American Society for Testing Material (ASTM) standards, producing a satisfactory result.

5.
Phys Eng Sci Med ; 44(3): 703-712, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34047928

ABSTRACT

Automated assessment and segmentation of Brain MRI images facilitate towards detection of neurological diseases and disorders. In this paper, we propose an improved U-Net with VGG-16 to segment Brain MRI images and identify region-of-interest (tumor cells). We compare results of improved U-Net with a custom-designed U-Net architecture by analyzing the TCGA-LGG dataset (3929 images) from the TCI archive, and achieve pixel accuracies of 0.994 and 0.9975 from basic U-Net and improved U-Net architectures, respectively. Our results outperformed common CNN-based state-of-the-art works.


Subject(s)
Brain Neoplasms , Image Processing, Computer-Assisted , Brain Neoplasms/diagnostic imaging , Humans , Magnetic Resonance Imaging , Neural Networks, Computer , Neuroimaging
SELECTION OF CITATIONS
SEARCH DETAIL