Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 480
Filter
1.
Spine J ; 2024 Sep 30.
Article in English | MEDLINE | ID: mdl-39357743

ABSTRACT

BACKGROUND CONTEXT: Pedicle screw instrumentation is widely used in spine surgery. Axial screw misplacement is a common complication. In addition to the recognized neurovascular risks associated with screw misplacement, the biomechanical stability of misplaced screws remains a subject of debate. PURPOSE: The present study investigates whether screw misplacement in the lumbar spine reduces mechanical screw hold. STUDY DESIGN/SETTING: Cadaveric biomechanical study METHODS: Pedicle screw (mis)placement was planned for 12 fresh frozen cadaveric spines between the T12 and the L5 levels. The screws were then implanted into the vertebrae with the help of 3D-printed template guides. Pre- and post-instrumentation computed tomography (CT) scans were acquired for instrumentation planning and quantification of the misplacement. The instrumented vertebrae were potted into CT transparent boxes using Polymethyl methacrylate and mounted on a standardized biomechanical setup for pull-out (PO) testing with uniaxial tensile load. RESULTS: The bone density of all the specimens as per HU was comparable. The predicted pull-out force (POF) for screws medially misplaced by 2mm, 4mm, and 6mm was respectively 985 N (SD 474), 968 N (SD 476) and 822 N (SD 478). For screws laterally misplaced by 2mm, 4mm, and 6mm the POF was respectively 605 N (SD 473), 411 N (SD 475), and 334 N (SD 477). Screws that did not perforate the pedicle (control) resisted pull-out forces of 837 N (SD 471). CONCLUSIONS: Medial misplacement is associated with increased axial screw hold against static loads compared to correctly placed screws and laterally placed screws. CLINICAL SIGNIFICANCE: In clinical settings, the reinsertion of medially misplaced screws should primarily aim to prevent neurological complications while the reinsertion of lateral misplaced screws should aim to prevent screw loosening.

2.
Cureus ; 16(9): e68760, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39376803

ABSTRACT

Neuronavigation, a computer-assisted surgical technique, enhances the accuracy of spinal surgery by using medical imaging to guide the surgeon's instruments. This method mitigates the serious complications of screw misplacement, such as dural tears, nerve damage, vascular injuries, and internal organ damage, by integrating pre-operative imaging data with real-time intraoperative sensor readings. Because of this integration, it is possible to visualize the spine in three dimensions, guaranteeing accurate instrument placement and greatly lowering the risk of complications. Despite its growing popularity, the benefits of neuronavigation in spinal instrumentation are debated. While some studies report improved accuracy in pedicle screw placement, others find no significant difference compared to conventional freehand techniques. Further research is required to determine the long-term benefits of neuronavigation, including its impact on patient outcomes, like reduced pain and improved function. This systematic review will evaluate the evidence on the risks and benefits of neuronavigation in spinal instrumentation surgery, compared to conventional techniques.

3.
J Spine Surg ; 10(3): 386-394, 2024 Sep 23.
Article in English | MEDLINE | ID: mdl-39399071

ABSTRACT

Background: Interspinous devices were introduced in the field of spine surgery as an alternative to traditional pedicle screw fixation in selected patients for treatment of spinal stenosis and fixation. These devices designs have evolved from non-fixated extension blocks to sophisticated interspinous fixation devices (IFDs). There is an absence of literature comparing the biomechanical fixation strength of different IFD plate designs and the role of set screw locking systems. The aim of this study was to evaluate fixation strengths by bench testing static disassembly and pullout strength of two dissimilar IFD designs and locking mechanisms. We hypothesized that the InSpan (InSpan LLC, Burlington, MA, USA) dual-locking symmetrically IFD plate designed will have stronger fixation than the Aspen (ZimVie, Parsippany, NJ, USA) single-locking asymmetric IFD plate design. Methods: We conducted two biomechanical bench tests to evaluate the load to failure locking characteristics of symmetrical InSpan and asymmetrical Aspen IFD designs. Static pullout testing involved locking each IFD to the stainless steel and 40 pcf cellular polyurethane foam and measuring pullout load and displacement six times. Seven InSpan and two Aspen IFDs (including the "used" IFDs from the pullout testing) underwent static disassembly tests using a pair of disassembly fixtures positioned between the IFD plates to measure disassembly force and displacement. All tests were performed under ambient conditions using an INSTRON 8874 Bi-Axial Tabletop Servohydraulic Dynamic Testing System (INSTRON, Norwood, MA, USA), and data was collected at a 0.2 mm/s displacement control rate until the test was stopped when there was a drop in the continuously increasing force against resistance (gross failure). Results: The InSpan IFD experienced 94.81% higher resistance to pullout compared to the Aspen IFD in static pullout testing (P<0.05), owing to its notably larger footprint area of 69.8%. Gross failure for both IFD implant designs occurred at the foam block-block interface. In static disassembly testing, pristine InSpan required 60.7% higher force over pristine Aspen and 401.3% for "used" IFDs. Gross failure was characterized by the gradual distraction of the plates and material removal at the set screw contact points. Implant failure at the block-implant interface emphasized the pivotal role of teeth design and the contact surface area of the plates in ensuring stability. Conclusions: The dual-locking symmetrical InSpan IFD outperformed single-locking asymmetric Aspen IFD in both static disassembly and pullout bench tests. This highlights the benefits of InSpan's improved design and its potential for enhanced long-term stability in spinal fixation applications.

4.
J Spine Surg ; 10(3): 354-361, 2024 Sep 23.
Article in English | MEDLINE | ID: mdl-39399093

ABSTRACT

Background: Achieving optimal immediate stability is crucial in lumbar fusion surgeries. Traditionally, four pedicle screws have been utilized to provide posterior stability at the L5-S1 level. However, the use of bilateral transfacet pedicle screws (TFPS) as an alternative construct has shown promising results in terms of biomechanical stability. This research paper investigates the biomechanical stability of TFPS with a lag design in comparison to equivalent-sized unilateral or bilateral fully threaded pedicle screw-rod (PSR) constructs at the L5-S1 disc level. The study assesses the immediate stability achieved by these constructs which have clinical implications in achieving lumbar segment fusion. We hypothesized that bilateral TFPS will yield immediate lumbar fixation that is comparable to unilateral or bilateral PSR constructs. Methods: Cadaveric biomechanical testing was conducted in vitro to evaluate the stability of posterior fixation using bilateral TFPS (FacetFuse®, LESSpine, Burlington, MA, USA), bilateral and unilateral PSR (PedFuse Return, LESSpine, Burlington, MA, USA) constructs measuring 5.0 mm × 40 mm. A comprehensive analysis of range of motion (ROM) and stability under various loading conditions was performed to a maximum of 7.5 Nm. The constructs were assessed for their ability to provide immediate stability at the L5-S1 disc level. Results: Fourteen specimens were analyzed with an average age of 53.14±10.99 years and comparable bone mineral density. TFPS demonstrated a reduced ROM that was notably lower than that of unilateral PSR in all loading modes and was comparable to bilateral PSR, especially in extension and axial rotation (AR). The unilateral and bilateral PSR groups differed notably in lateral bending (LB) and AR. Conclusions: Bilateral TFPS demonstrated superior immediate stability than unilateral PSR and was an equivalent substitute to bilateral PSR constructs at the L5-S1 disc level. Further clinical investigations are necessary to validate these results and ascertain the long-term outcomes and advantages associated with the use of bilateral TFPS as an alternative construct. Our findings showed that bilateral TFPS could potentially reduce the number of required pedicle screws while achieving comparable stability in lumbar fusion procedures.

5.
J Clin Med ; 13(18)2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39337041

ABSTRACT

This paper delves into the historical evolution of spinal surgery, focusing on the pivotal role of the Harrington rod in treating spinal deformities. Introduced in 1955, the Harrington rod marked a significant breakthrough in neurosurgery, especially for scoliosis treatment, by offering a novel approach to spinal stabilization. Through a retrospective analysis, this study examines the development and impact of the Harrington rod, highlighting Dr. Paul Harrington's contributions to spinal surgery. His innovative technique revolutionized the management of spinal deformities, laying the groundwork for future advancements in spinal instrumentation. Despite initial skepticism, Harrington's methods gained acceptance, significantly influencing neurosurgical practices and patient outcomes. This study also explores subsequent advancements that built on Harrington's work, including the transition to long-segment spine constructs and the introduction of segmental pedicle screws, which allowed for more precise deformity correction. Reflecting on Harrington's legacy, this paper acknowledges the continuous evolution of spinal surgery, driven by the interplay between clinical challenges and technological innovations. Harrington's pioneering spirit exemplifies the ongoing pursuit of better surgical outcomes, underscoring the importance of innovation in the field of neurosurgery.

6.
World Neurosurg ; 2024 Sep 11.
Article in English | MEDLINE | ID: mdl-39270794

ABSTRACT

OBJECTIVE: This study aims to evaluate the safety and efficacy of the ultrasonic bone burr (UBB) in facilitating C1 pedicle screw placement for atlantoaxial instability treatment, compared to the conventional high-speed drill (HSD) technique. METHODS: A retrospective analysis was conducted on patients undergoing posterior screw-rod fixation for atlantoaxial instability between December 2017 and July 2023. The patients were divided into 2 groups based on the tools used for screw placement: UBB and HSD. Data on surgical duration, estimated blood loss, spinal cord and arterial injury incidence, screw placement accuracy, neurological status measured by the Japanese Orthopedic Association score, and fusion rates were collected and analyzed. RESULTS: Thirteen patients received C1 pedicle screw placement via UBB facilitation, while 8 were treated using the HSD approach. The UBB group showed a significant reduction in blood loss and operation time compared to the HSD group (P = 0.002 and P < 0.001, respectively). No spinal cord or arterial injuries occurred in either group. Optimal screw placement was confirmed in all UBB cases versus 87.5% in the HSD group (P = 0.139). Both groups demonstrated significant improvements in Japanese Orthopedic Association scores with no intergroup difference. The fusion rate was 100% in the UBB group and 87.5% in the HSD group, not statistically different (P = 0.381). CONCLUSIONS: UBB is a viable alternative for C1 pedicle screw placement, associated with reduced blood loss and shorter operation time, while achieving comparable clinical outcomes to the conventional HSD method. Nevertheless, further research with a larger sample size is needed.

7.
JOR Spine ; 7(3): e70001, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39291095

ABSTRACT

Background: In spinal revision surgery, previous pedicle screws (PS) may need to be replaced with new implants. Failure to accurately identify the brand of PS-based instrumentation preoperatively may increase the risk of perioperative complications. This study aimed to develop and validate an optimal deep learning (DL) model to identify the brand of PS-based instrumentation on plain radiographs of spine (PRS) using anteroposterior (AP) and lateral images. Methods: A total of 529 patients who received PS-based instrumentation from seven manufacturers were enrolled in this retrospective study. The postoperative PRS were gathered as ground truths. The training, validation, and testing datasets contained 338, 85, and 106 patients, respectively. YOLOv5 was used to crop out the screws' trajectory, and the EfficientNet-b0 model was used to develop single models (AP, Lateral, Merge, and Concatenated) based on the different PRS images. The ensemble models were different combinations of the single models. Primary outcomes were the models' performance in accuracy, sensitivity, precision, F1-score, kappa value, and area under the curve (AUC). Secondary outcomes were the relative performance of models versus human readers and external validation of the DL models. Results: The Lateral model had the most stable performance among single models. The discriminative performance was improved by the ensemble method. The AP + Lateral ensemble model had the most stable performance, with an accuracy of 0.9434, F1 score of 0.9388, and AUC of 0.9834. The performance of the ensemble models was comparable to that of experienced orthopedic surgeons and superior to that of inexperienced orthopedic surgeons. External validation revealed that the Lat + Concat ensemble model had the best accuracy (0.9412). Conclusion: The DL models demonstrated stable performance in identifying the brand of PS-based instrumentation based on AP and/or lateral images of PRS, which may assist orthopedic spine surgeons in preoperative revision planning in clinical practice.

8.
Spine J ; 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39154945

ABSTRACT

BACKGROUND: Intraoperative 3D imaging with cone-beam CT (CBCT) improves assessment of implant position and reduces complications in spine surgery. It is also used for image-guided surgical techniques, resulting in improved quality of care. However, in some cases, metal artifacts can reduce image quality and make it difficult to assess pedicle screw position and reduction. PURPOSE: The objective of this study was to investigate whether a change in CBCT acquisition trajectory in relation to pedicle screw position during dorsal instrumentation can reduce metal artifacts and consequently improve image quality and clinical assessability. STUDY DESIGN: Experimental cadaver study. METHODS: A human cadaver was instrumented with pedicle screws in the thoracic and lumbar spine region (Th11 to L5). Then, the acquisition trajectory of the CBCT (Cios Spin, Siemens, Germany) to the pedicle screws was systematically changed in 5° steps in angulation (-30° to +30°) and swivel (-25° to +25°). Subsequently, radiological evaluation was performed by 3 blinded, qualified raters on image quality using 9 questions (including anatomical structures, implant position, appearance of artifacts) with a score (1-5 points). For statistical evaluation, the image quality of the different acquisition trajectories was compared to the standard acquisition trajectory and checked for significant differences. RESULTS: The angulated acquisition trajectory significantly increased the score for subjective image quality (p<.001) as well as the clinical assessability of pedicle screw position (p<.001) with particularly strong effects on subjective image quality in the vertebral pedicle region (d=1.61). Swivel of the acquisition trajectory significantly improved all queried domains of subjective image quality (p<.001) as well as clinical assessability of pedicle screw position (p<.001). CONCLUSIONS: In this cadaver study, the angulation as well as the swivel of the acquisition trajectory led to a significantly improved image quality in intraoperative 3D imaging (CBCT) with a constant isocenter. The data show that maximizing the angulation/swivel angle towards 30°/25° provides the best tested subjective image quality and enhances clinical assessability. Therefore, a correct adjustment of the acquisition trajectory can help to make intraoperative revision decisions more reliably. CLINICAL SIGNIFICANCE: The knowledge of enhanced image quality by changing the acquisition trajectory in intraoperative 3D imaging can be used for the assessment of critical screw positions in spine surgery. The implementation of this knowledge requires only a minor change of the current intraoperative imaging workflow without additional technical equipment and could further reduce the need for revision surgery.

9.
J Neurosurg Spine ; 41(4): 519-531, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38968628

ABSTRACT

OBJECTIVE: Pedicle screw placement guidance is critical in spinal fusions, and spinal surgery robots aim to improve accuracy and reduce complications. Current literature has yet to compare the relative merits of available robotic systems. In this review, the authors aimed to 1) assess the current state of spinal robotics literature; 2) conduct a meta-analysis of robotic performance based on accuracy, speed, and safety; and 3) offer recommendations for robotic system selection. METHODS: Following PRISMA guidelines, the authors conducted a systematic literature review across PubMed, Embase, Cochrane Library, Web of Science, and Scopus as of April 28, 2022, for studies on approved robots for placing lumbar pedicle screws. Three reviewers screened and extracted data relating to the study characteristics, accuracy rate, intraoperative revisions, and reoperations. Secondary performance metrics included operative time, blood loss, and radiation exposure. The authors statistically compared the performance of the robots using a random-effects model to account for variation within and between the studies. Each robot was also compared with performance benchmarks of traditional techniques including freehand, fluoroscopic, and CT-navigated insertion. Finally, we performed a Duval and Tweedie trim-and-fill test to assess for the presence of publication bias. RESULTS: The authors identified 46 studies, describing 4670 patients and 25,054 screws, that evaluated 4 different robotic systems: Mazor X, ROSA, ExcelsiusGPS, and Cirq. The weighted accuracy rates of Gertzbein-Robbins classification grade A or B screws were as follows: ExcelsiusGPS, 98.0%; ROSA, 98.0%; Mazor, 98.2%; and Cirq, 94.2%. No robot was significantly more accurate than the others. However, the accuracy of the ExcelsiusGPS was significantly higher than that of traditional methods, and the accuracies of the Mazor and ROSA were significantly higher than that of fluoroscopy. The intraoperative revision rates were Cirq, 0.55%; ROSA, 0.91%; Mazor, 0.98%; and ExcelsiusGPS, 1.08%. The reoperation rates were Cirq, 0.28%; ExcelsiusGPS, 0.32%; and Mazor, 0.76% (no reoperations were reported for ROSA). Operative times were similar for all robots. Both the ExcelsiusGPS and Mazor were associated with significantly less blood loss than the ROSA. The Cirq had the lowest radiation exposure. Robots tended to be more accurate and generally their use was associated with fewer reoperations and less blood loss than freehand, fluoroscopic, or CT-navigated techniques. CONCLUSIONS: Robotic platforms perform comparably based on key metrics, with high accuracy rates and low intraoperative revision and reoperation rates. The spinal robotics publication rate will continue to accelerate, and choosing a robot will depend on the context of the practice.


Subject(s)
Pedicle Screws , Reoperation , Robotic Surgical Procedures , Spinal Fusion , Humans , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Spinal Fusion/methods , Spinal Fusion/instrumentation , Reoperation/statistics & numerical data , Operative Time , Treatment Outcome
10.
J Craniovertebr Junction Spine ; 15(2): 224-229, 2024.
Article in English | MEDLINE | ID: mdl-38957756

ABSTRACT

Introduction: Transpedicular screw placement has superior pullout strength compared to alternative forms of spinal fusion and is often performed in deformity correction surgery with navigation for optimal accuracy and reliability. Freehand technique for pedicle screws minimizes operation time and radiation exposure without fluoroscopy but is not widely adopted given the challenge of difficult anatomical corridors and accurate placement, especially in idiopathic scoliosis and advanced deformity. We used a computer-generated model to assess a proof-of-concept and anatomical feasibility of a freehand screw technique in severe scoliosis. Methods: Three-dimensional (3D) reconstructions of vertebra from a sample of two male patients with severe idiopathic scoliosis deformity (1 thoracic and 1 lumbar) with Cobb angles of 100° were used for planned placement of 17 levels of thoracolumbar (6.5 mm × 45 mm) pedicle screws. 3D reconstruction of each vertebra was created and measurements of screw entries and trajectories were reproduced with a 3D slicer software image computing platform. Results: Accurate transpedicular screw placement is possible with anatomical landmarks based on the 3D reconstructed vertebral levels. A series of 5 figures were assembled to demonstrate sagittal, coronal, and axial planes and key anatomical landmarks and trajectories of thoracic and lumbar freehand pedicle screws in severe idiopathic scoliosis. Conclusions: Anatomical landmarks for freehand transpedicular screw placement (between pedicle, lamina, and superior articulating process) are constant and reliable in severe idiopathic scoliosis as evidenced by 3D computer modeling. Preoperative computed tomography modeling may assist appropriate screw entry and trajectory based on anatomical landmarks for spine surgeons, and guide freehand technique for screw placement in adolescent idiopathic scoliosis.

11.
Front Bioeng Biotechnol ; 12: 1416872, 2024.
Article in English | MEDLINE | ID: mdl-39070162

ABSTRACT

Background: Cervical spinal fusion surgeries require accurate placement of the pedicle screws. Any misplacement/misalignment of these screws may lead to injuries to the spinal cord, arteries and other organs. Template guides have emerged as accurate and cost-effective tools for the safe and rapid insertions of pedicle screws. Questions/Purposes: Novel patient-specific single- and multi-level non-covering templates for cervical pedicle screw insertions were designed, 3D-printed, and evaluated. Methods: CT scans of two patients were acquired to reconstruct their 3D spine model. Two sets of single-level (C3-C7) and multi-level (C4-C6) templates were designed and 3D-printed. Pedicle screws were inserted into the 3D-printed vertebrae by free-hand and guided techniques. For single-level templates, a total of 40 screws (2 patients × 5 vertebrae × 2 methods × 2 screws) and for multi-level templates 24 screws (2 patients × 3 vertebrae × 2 methods × 2 screws) were inserted by an experienced surgeon. Postoperative CT images were acquired to measure the errors of the entry point, 3D angle, as well as axial and sagittal plane angles of the inserted screws as compared to the initial pre-surgery designs. Accuracy of free-hand and guided screw insertions, as well as those of the single- and multi-level guides, were also compared using paired t-tests. Results: Despite the minimal removal of soft tissues, the 3D-printed templates had acceptable stability on the vertebrae during drillings and their utilization led to statistically significant reductions in all error variables. The mean error of entry point decreased from 3.02 mm (free-hand) to 0.29 mm (guided) using the single-level templates and from 5.7 mm to 0.76 mm using the multi-level templates. The percentage reduction in mean of other error variables for, respectively, single- and multi-level templates were as follows: axial plane angle: 72% and 87%, sagittal plane angle: 56% and 78%, and 3D angle: 67% and 83%. The error variables for the multi-level templates generally exceeded those of the single-level templates. The use of single- and multi-level templates also considerably reduced the duration of pedicle screw placements. Conclusion: The novel single- and multi-level non-covering templates are valuable tools for the accurate placement of cervical pedicle screws.

12.
ACS Appl Mater Interfaces ; 16(25): 31983-31996, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38865688

ABSTRACT

Effective osteointegration is of great importance for pedicle screws in spinal fusion surgeries. However, the lack of osteoinductive activity of current screws diminishes their feasibility for osteointegration and fixation, making screw loosening a common complication worldwide. In this study, Ti-6Al-4V pedicle screws with full through-hole design were fabricated via selective laser melting (SLM) 3D printing and then deposited with porous oxide coatings by microarc oxidation (MAO). The porous surface morphology of the oxide coating and the release of bioactive ions could effectively support cell adhesion, migration, vascularization, and osteogenesis in vitro. Furthermore, an in vivo goat model demonstrated the efficacy of modified screws in improving bone maturation and osseointegration, thus providing a promising method for feasible orthopedic internal fixation.


Subject(s)
Ceramics , Goats , Osseointegration , Oxidation-Reduction , Pedicle Screws , Printing, Three-Dimensional , Titanium , Animals , Osseointegration/drug effects , Titanium/chemistry , Titanium/pharmacology , Ceramics/chemistry , Ceramics/pharmacology , Alloys/chemistry , Alloys/pharmacology , Osteogenesis/drug effects , Humans , Porosity , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Cell Adhesion/drug effects
13.
BMC Musculoskelet Disord ; 25(1): 458, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38858717

ABSTRACT

BACKGROUND: Minimally invasive posterior fixation surgery for pyogenic spondylitis is known to reduce invasiveness and complication rates; however, the outcomes of concomitant insertion of pedicle screws (PS) into the infected vertebrae via the posterior approach are undetermined. This study aimed to assess the safety and efficacy of PS insertion into infected vertebrae in minimally invasive posterior fixation for thoracolumbar pyogenic spondylitis. METHODS: This multicenter retrospective cohort study included 70 patients undergoing minimally invasive posterior fixation for thoracolumbar pyogenic spondylitis across nine institutions. Patients were categorized into insertion and skip groups based on PS insertion into infected vertebrae, and surgical data and postoperative outcomes, particularly unplanned reoperations due to complications, were compared. RESULTS: The mean age of the 70 patients was 72.8 years. The insertion group (n = 36) had shorter operative times (146 versus 195 min, p = 0.032) and a reduced range of fixation (5.4 versus 6.9 vertebrae, p = 0.0009) compared to the skip group (n = 34). Unplanned reoperations occurred in 24% (n = 17) due to surgical site infections (SSI) or implant failure; the incidence was comparable between the groups. Poor infection control necessitating additional anterior surgery was reported in four patients in the skip group. CONCLUSIONS: PS insertion into infected vertebrae during minimally invasive posterior fixation reduces the operative time and range of fixation without increasing the occurrence of unplanned reoperations due to SSI or implant failure. Judicious PS insertion in patients with minimal bone destruction in thoracolumbar pyogenic spondylitis can minimize surgical invasiveness.


Subject(s)
Lumbar Vertebrae , Minimally Invasive Surgical Procedures , Operative Time , Pedicle Screws , Spondylitis , Thoracic Vertebrae , Humans , Retrospective Studies , Male , Female , Aged , Thoracic Vertebrae/surgery , Lumbar Vertebrae/surgery , Minimally Invasive Surgical Procedures/methods , Spondylitis/surgery , Spondylitis/diagnostic imaging , Spondylitis/microbiology , Middle Aged , Aged, 80 and over , Spinal Fusion/methods , Spinal Fusion/adverse effects , Spinal Fusion/instrumentation , Treatment Outcome , Reoperation , Surgical Wound Infection/epidemiology , Surgical Wound Infection/etiology , Surgical Wound Infection/prevention & control
14.
J Clin Med ; 13(9)2024 May 03.
Article in English | MEDLINE | ID: mdl-38731218

ABSTRACT

Background: Although several biomechanical studies have been reported, few clinical studies have compared the efficacy of monoaxial and polyaxial pedicle screws in the surgical treatment of adolescent idiopathic scoliosis (AIS). This study aims to compare the radiological and clinical outcomes of mono- and polyaxial pedicle screws in the surgical treatment of AIS. Methods: A total of 46 AIS patients who underwent surgery to treat scoliosis using pedicle screw instrumentation (PSI) and rod derotation (RD) were divided into two groups according to the use of pedicle screws: the monoaxial group (n = 23) and polyaxial group (n = 23). Results: The correction rate of the main Cobb's angle was higher in the monoaxial group (70.2%) than in the polyaxial group (65.3%) (p = 0.040). No differences in the rotational correction of the apical vertebra were evident between the two groups. SRS-22 scores showed no significant differences according to the type of pedicle screws used. Conclusions: The use of polyaxial pedicle screws resulted in coronal, sagittal, and rotational correction outcomes comparable to those associated with the use of monoaxial pedicle screws for surgical treatment using PSI and RD to treat moderate cases of AIS.

15.
Zhongguo Gu Shang ; 37(5): 470-6, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778530

ABSTRACT

OBJECTIVE: To explore the clinical effect of percutaneous pedicle screw anchored vertebral augmentation(PPSAVA) in the treatment of asymptomatic Kümmell disease without neurological symptoms. METHODS: The clinical data of 20 patients with Kümmell disease without neurological symptoms treated with PPSAVA in our hospital from January 2019 to December 2021 were analyzed retrospectively, including 5 males and 15 females, aged 56 to 88 (74.95±9.93) years old. and the course of disease was 7 to 60 days with an average of (21.35±14.46) days. All patients were treated with PPSAVA. The time of operation, the amount of bone cement injected and the leakage of bone cement were recorded. The visual analogue scale(VAS), Oswestry disability index(ODI), vertebral body angle(VBA), anterior edge height and midline height of vertebral body were compared among the before operation, 3 days after operation and during the final follow-up. The loosening and displacement of bone cement were observed during the final follow-up. RESULTS: All the 20 patients completed the operation successfully. The operation time was 30 to 56 min with an average of (41.15±7.65) min, and the amount of bone cement injection was 6.0 to 12.0 ml with an average of (9.30±1.49) ml. Bone cement leakage occurred in 6 cases and there were no obvious clinical symptoms. The follow-up time was 6 to 12 months with an average of (8.43±2.82) months. The VBA, anterior edge height and midline height of of injured vertebral body were significantly improved 3 days after operation and the final follow-up(P<0.05), and the VBA, anterior edge height and midline height of of injured vertebral body were lost in different degrees at the final follow-up (P<0.05). The VAS and ODI at 3 days after operation and at the final follow-up were significantly lower than those at preoperatively(P<0.05), but the VAS score and ODI at the final follow-up were not significantly different from those at 3 d after operation(P>0.05). At the last follow-up, no patients showed loosening or displacement of bone cement. CONCLUSION: PPSAVA is highly effective in treating Kümmell disease without neurological symptoms, improving patients' pain and functional impairment, and reducing the risk of cement loosening and displacement postoperatively.


Subject(s)
Pedicle Screws , Humans , Female , Male , Aged , Middle Aged , Aged, 80 and over , Retrospective Studies , Spinal Fractures/surgery , Bone Cements
16.
Spine Deform ; 12(4): 989-1000, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38558382

ABSTRACT

PURPOSE: Hypoplastic pedicles of the thoracolumbar spine (<5 mm diameter) are often found in syndromic deformities of the spine and pose a challenge in pedicle screw instrumentation. 3D-printed patient-specific guides might help overcome anatomical difficulties when instrumenting pedicles with screws, thereby reducing the necessity for less effective fixation methods such as hooks or sublaminar wires. In this study, the surgical feasibility and clinical outcome of patients with hypoplastic pedicles following pedicle screw instrumentation with 3D-printed patient-specific guides were assessed. METHODS: Hypoplastic pedicles were identified on preoperative computed tomography (CT) scans in six patients undergoing posterior spinal fusion surgery between 2017 and 2020. Based on these preoperative CT scans, patient-specific guides were produced to help with screw instrumentation of these thin pedicles. Postoperatively, pedicle-screw-related complications or revisions were analyzed. RESULTS: 93/105 (88.6%) pedicle screws placed with patient-specific guides were instrumented. 62/93 (66.7%) of these instrumented pedicles were defined as hypoplastic with a mean width of 3.07 mm (SD ±0.98 mm, 95% CI [2.82-3.32]). Overall, 6 complications in the 62 hypoplastic pedicles (9.7%) were observed and included intraoperatively managed 4 cerebrospinal fluid leaks, 1 pneumothorax and 1 delayed revision due to 2 lumbar screws (2/62, 3.3%) impinging the L3 nerve root causing a painful radiculopathy. The mean follow-up time was 26.7 (SD ±11.7) months. Complications were only noted when the pedicle-width-to-screw-diameter ratio measured less than 0.62. CONCLUSION: Patient-specific 3D-printed guides can aid in challenging instrumentation of hypoplastic pedicles in the thoracolumbar spine, especially if the pedicle-width-to-screw-diameter ratio is greater than 0.62.


Subject(s)
Pedicle Screws , Printing, Three-Dimensional , Spinal Fusion , Thoracic Vertebrae , Humans , Spinal Fusion/instrumentation , Spinal Fusion/methods , Male , Female , Thoracic Vertebrae/surgery , Thoracic Vertebrae/diagnostic imaging , Tomography, X-Ray Computed , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Adolescent , Feasibility Studies , Adult , Treatment Outcome , Postoperative Complications/etiology
17.
Spine Deform ; 12(4): 909-921, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38573487

ABSTRACT

BACKGROUND: Adolescent idiopathic scoliosis (AIS) affects 1-3% of adolescents, and treatment approaches, including the density of constructs in surgical fusion, vary among orthopedic surgeons. Studies have sought to establish whether high-density or low-density constructs offer superior clinical and radiological outcomes, yet conclusive results are lacking. This meta-analysis aims to provide a definitive answer to the controversial and ambiguous question surrounding the efficacy of different pedicle screw densities in treating AIS. METHODS: PubMed, Cochrane, and Google Scholar (page 1-20) were searched till December 2023. The studied outcomes were Major Cobb angle, major curve correction, lumbar curve, kyphosis (T5-T12), lumbar lordosis, coronal balance, LIV Tilt angle, TAV translation, LAV translation, apical trunk rotation, trunk shift, SRS-22, operative time, blood loss, complications and cost. RESULTS: Twenty-four studies (total of 1985 patients, 1045 in LD group and 940 in HD group) were included in this meta-analysis. A statistically significant better improvement in ATR (p = 0.02) and LIV tilt angle (p = 0.02) was seen in the high-density group. On the other hand, longer operative time (p = 0.002), blood loss (p = 0.0004) and costs (p = 0.02) were seen in the high-density group. No difference was seen in the remaining radiographic and clinical outcomes between both surgeries. CONCLUSION: Both low-density (LD) and high-density (HD) screw constructs show comparable and satisfactory radiographic and QOL for AIS patients. Furthermore, HD constructs had increased costs, operative time, and blood loss associated. However, a definitive conclusion cannot be made and more studies taking into account multiple additional variables are necessary to do so.


Subject(s)
Pedicle Screws , Scoliosis , Spinal Fusion , Humans , Scoliosis/surgery , Scoliosis/diagnostic imaging , Adolescent , Spinal Fusion/methods , Spinal Fusion/instrumentation , Treatment Outcome , Operative Time , Radiography , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging
18.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 466-473, 2024 Apr 15.
Article in Chinese | MEDLINE | ID: mdl-38632068

ABSTRACT

Objective: To investigate the effectiveness of injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion for thoracolumbar fracture dislocation with disc injury. Methods: Between January 2017 and June 2022, 28 patients with thoracolumbar fracture dislocation with disc injury were underwent posterior depression, the injured vertebra fixation with inclined-long pedicle screws, and interbody fusion. There were 22 males and 6 females, with a mean age of 41.4 years (range, 22-58 years). The causes of injury included falling from height in 18 cases, traffic accident in 5 cases, and bruise in 5 cases. Fracture segment included 1 case of T 11, 7 cases of T 12, 9 cases of L 1, and 11 cases of L 2. According to the American Spinal Injury Association (ASIA) scale, the spinal injuries were graded as grade A in 4 cases, grade B in 2 cases, grade C in 11 cases, and grade D in 11 cases. Preoperative spinal canal encroachment ratio was 17.7%-75.3% (mean, 44.0%); the thoracolumbar injury classification and severity score (TLICS) ranged from 9 to 10 (mean, 9.9). Seventeen patients were associated with other injuries. The time from injury to operation ranged from 1 to 4 days (mean, 2.3 days). The perioperative indicators (operation time, intraoperative blood loss, and the occurrence of complications), clinical evaluation indicators [visual analogue scale (VAS) score and Oswestry Disability Index (ODI)], radiologic evaluation indicators [anterior vertebral height ratio (AVHR), kyphosis Cobb angle (KCA), intervertebral space height (ISH), vertebral wedge angle (VWA), displacement angle (DA), and percent fracture dislocation displacement (PFDD)], neurological function, and interbody fusion were recorded. Results: The operation time was 110-159 minutes (mean, 130.2 minutes). The intraoperative blood loss was 200-510 mL (mean, 354.3 mL). All incisions healed by first intention, and no surgical complications such as wound infection or hematoma occurred. All patients were followed up 12-15 months (mean, 12.7 months). The chest and lumbar pain significantly relieved, VAS scores and ODI after operation were significantly lower than those before operation, and further decreased with the extension of postoperative time, with significant differences ( P<0.05). At last follow-up, the ASIA classification of neurological function of the patients was grade A in 3 cases, grade B in 1 case, grade C in 1 case, grade D in 10 cases, and grade E in 13 cases, which was significantly different from preoperative one ( Z=-4.772, P<0.001). Imaging review showed that AVHR, KCA, ISH, VWA, DA, and PFDD significantly improved at 1 week, 3 months and last follow-up ( P<0.05). There was no significant difference between different time points after operation ( P>0.05). At last follow-up, according to the modified Brantigan score, all patients achieved good intervertebral bone fusion, including 22 complete fusion and 6 good intervertebral fusion with a few clear lines. No complications such as internal fixation failure or kyphosis occurred during follow-up. Conclusion: The injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion is an effective treatment for thoracolumbar fracture dislocation with disc injury, which can correct the fracture dislocation, release the nerve compression, restore the injured vertebral height, and reconstruct spinal stabilization.


Subject(s)
Fracture Dislocation , Fractures, Bone , Kyphosis , Pedicle Screws , Spinal Fractures , Adult , Female , Humans , Male , Blood Loss, Surgical , Fracture Fixation, Internal/methods , Lumbar Vertebrae/surgery , Retrospective Studies , Spinal Fractures/surgery , Thoracic Vertebrae/surgery , Treatment Outcome , Young Adult , Middle Aged
19.
J Clin Med ; 13(8)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38673447

ABSTRACT

Background: Modern surgical techniques allow for the correction of spinal deformity, stopping its progression and improving pain relief and social and physical functioning. These instruments have different implant designs, screws, and rod diameters and can be composed of different metal alloys with different hardnesses, which can have a significant impact on the effect of correcting spinal deformities. We designed a retrospective cohort study based on the same surgical technique and spine system using different implant sizes, and compared the results across them. Methods: This is a retrospective review of adolescent idiopathic scoliosis (AIS) patients who underwent posterior spinal fusion (PSF) between 2016 and 2022 with a minimum two-year follow-up (FU) using two spinal implant systems: 5.5 and 6.0 mm diameter screws with double 5.5 mm titanium rods (Group 1 (G1)), and 6.0 and 6.5 mm diameter pedicle screws with double 6.0 mm cobalt-chromium rods (Group 2 (G2)). The evaluated data were as follows: preoperative personal data, radiographic outcomes, complications, and health-related quality of life questionnaire (HRQoL). The parameters were reviewed preoperatively, after the final fusion, and during the FU. Results: The mean age of all 260 patients at surgery was 14.8 years. The average BMI was also similar in both groups and was noted as 21. The mean levels of fusion and screw density were similar in both groups. The mean preoperative major curves (MCs) were 57.6° and 62.5° in G1 and G2, respectively. The mean flexibility of the curves was noted as 35% in G1 and 33% in G2. After definitive surgery, the mean percentage correction of the MC was better in G2 vs. G1, with 74.5% vs. 69.8%, respectively (p < 0.001). At the final FU, the average loss of correction was 5.9° for G1 and 3.2° for G2 (p < 0.001). The mean preoperative (TK) thoracic kyphosis (T2-T5) was 12.2° in G1 and 10.8° in G2. It was corrected to 15.2° in G1 and to 13° in G2. At the FFU, we noted a significant difference in the TK (T2-T5) between the groups, with 16.7° vs. 9.6° for G1 vs. G2, respectively (p < 0.001). Statistical significance was observed between the preoperative sagittal balance and the final follow-up for both groups (p < 0.001). Conclusions: AIS patients surgically treated with screws with a larger diameter and thicker and stiffer rods showed greater correction and postoperative thoracic kyphosis without implant failure. The complication rates, implant density, and clinical outcomes remained similar. The radiographic benefits reported in this cohort study suggest that large-sized screws and stiffer rods for the correction of pediatric spinal deformities are safe and very effective.

20.
Neurospine ; 21(1): 116-127, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38569638

ABSTRACT

OBJECTIVE: This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery. METHODS: We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed. RESULTS: Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained. CONCLUSION: RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.

SELECTION OF CITATIONS
SEARCH DETAIL