Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Front Pediatr ; 12: 1410627, 2024.
Article in English | MEDLINE | ID: mdl-38873580

ABSTRACT

Background: While positive pressure ventilation has been considered an important contributing factor associated with pulmonary air leaks, studies examining the association between specific ventilatory settings during acute-phase high-frequency oscillatory ventilation (HFOV) and pulmonary air leaks among extremely preterm infants are limited. Methods: This was a single-center retrospective cohort study conducted at an institution that primarily used HFOV after intubation in extremely preterm infants. We analyzed data from extremely preterm infants born between 2010 and 2021. The primary outcome was pulmonary air leakage during the first 7 days of life. The exposure variable was the maximum mean airway pressure (MAP) on HFOV during the first 7 days of life or before the onset of pulmonary air leaks. Maximum MAP was categorized into three groups: low (7-10 cmH2O), moderate (11-12 cmH2O), and high (13-15 cmH2O) MAP categories. We conducted robust Poisson regression analyses after adjustment for perinatal confounders, using the low MAP category as the reference. Results: The cohort included 171 infants (low MAP, 123; moderate MAP, 27; and high MAP, 21). The median (interquartile range) gestational age and birth weight were 25.7 (24.3-26.7), 25.7 (24.9-26.9), and 25.3 (24.3-26.6) weeks and 760 (612-878), 756 (648-962), and 734 (578-922) g for infants in the low, moderate, and high MAP categories, respectively. Compared to infants in the low MAP category, those in the high MAP category had a higher incidence of pulmonary air leaks (4.1% vs. 33.3%; adjusted risk ratio, 5.4; 95% confidence interval, 1.6-18.5). In contrast, there was no clear difference in the risk of pulmonary air leaks between the moderate and low MAP categories (3.7% vs. 4.1%; adjusted risk ratio, 0.9; 95% confidence interval, 0.1-6.1). Conclusion: Extremely preterm infants requiring high MAP (≥13 cmH2O) in acute-phase HFOV had a higher risk of pulmonary air leak during the first 7 days of life.

2.
J Thorac Dis ; 15(11): 6151-6159, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38090287

ABSTRACT

Background: Pulmonary resection can present technical challenges for surgeons due to the dissection and closure of tissues, which vary in thickness and elastic properties, occasionally leading to prolonged air leaks. Staple line reinforcements (SLRs) are widely utilized tools for fortifying the stability and integrity of closures in thoracic surgery, however, materials available and ease of use for both surgeon and scrub nurse have been suboptimal. A novel "click-and-go" device pre-loaded with bioabsorbable buttress material was recently developed, the Echelon Endopath SLR (ESLR, Ethicon, Inc., Cincinnati, OH, USA). This prospective study examines the safety and efficacy of this novel device in lung resections. Methods: Adult surgical candidates undergoing primary pulmonary resection (both open and thoracoscopic) where the ESLR would be used were enrolled. Exclusion included reoperation/revision in same anatomical location, hypersensitivity to polyglactin or related products, and body mass index (BMI) ≥46.0 kg/m2. The primary endpoint assessed the incidence of specific device-related adverse events (AEs): prolonged air leak and empyema. Additional endpoints included number of devices replaced during surgery due to slippage or bunching, and surgeon-reported usability responses. Data was summarized for AEs deemed device-related and usability questionnaire responses. Results: A total of 131 subjects were included in the primary endpoint analysis data set with 120 subjects completing the study (91.6%). The mean age at consent was 62.8±12.0 years and 55.7% were female. The most common primary indication for the procedure was malignancy 61.1%, and primary non-malignant lung disease (non-chronic obstructive pulmonary disease) 12.2%. Common procedures performed were wedge resection (58.0%) and lobectomy (34.4%). There were zero reported device-specific/-related AEs which counted toward the primary endpoint. Responses from a usability questionnaire found all surgeons (100.0%) reported the ease of setup was superior to previous devices utilized. Surgeons expressed greater confidence in the buttress material of the ESLR than that of previous SLR devices (strongly agree 88.9%; slightly agree 11.1%). Most also felt that there was less wastage with the click-and-go ESLR (strongly agree 77.8%, slightly agree 11.1%, neutral 11.1%). Conclusions: The ESLR device demonstrates safe and effective performance in this post-market study of specific thoracic procedures. Furthermore, surgeons found this was easier to use.

3.
Surg Today ; 53(1): 31-41, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36376403

ABSTRACT

PURPOSE: Intraoperative control of air leaks is important for preventing prolonged air leaks after surgery. The usefulness of suturing free pericardial fat pads (FPFPs) as pledgets for repairing air leaks was investigated. METHODS: A total of 111 patients who underwent anatomical lung resection and required suture repair for intraoperative air leaks were retrospectively reviewed. Mattress sutures were performed using polyglycolic acid (PGA) sheets (PGA group; n = 60) in the early period (April 2014 to March 2018) and FPFPs (FPFP group; n = 51) in the late period (April 2018 to March 2021) as pledgets. RESULTS: More patients had a history of smoking in the FPFP group than in the PGA group. The duration of air leakage was significantly shorter (mean 1.2 vs. 3.5 days, p = 0.002) and prolonged air leakage (> 5 days) was less frequently observed (23.3% vs. 5.9%, p = 0.016) in the FPFP group than in the PGA group. The FPFP group had fewer cases requiring pleurodesis and with recurrent air leaks than in the PGA group. In one case in the FPFP group, fat necrosis with fibrosis and fibrous adhesion to the visceral pleura was found on a pathological examination. CONCLUSION: Parenchymal repair using FPFPs as pledgets can reduce prolonged air leaks after surgery.


Subject(s)
Adipose Tissue , Pneumonectomy , Humans , Retrospective Studies , Pleura , Postoperative Complications/prevention & control
4.
Front Med (Lausanne) ; 9: 848639, 2022.
Article in English | MEDLINE | ID: mdl-35433732

ABSTRACT

Background: The role of excessive inspiratory effort in promoting alveolar and pleural rupture resulting in air leak (AL) in patients with SARS-CoV-2 induced acute respiratory failure (ARF) while on spontaneous breathing is undetermined. Methods: Among all patients with COVID-19 related ARF admitted to a respiratory intensive care unit (RICU) and receiving non-invasive respiratory support, those developing an AL were and matched 1:1 [by means of PaO2/FiO2 ratio, age, body mass index-BMI and subsequent organ failure assessment (SOFA)] with a comparable population who did not (NAL group). Esophageal pressure (ΔPes) and dynamic transpulmonary pressure (ΔPL) swings were compared between groups. Risk factors affecting AL onset were evaluated. The composite outcome of ventilator-free-days (VFD) at day 28 (including ETI, mortality, tracheostomy) was compared between groups. Results: Air leak and NAL groups (n = 28) showed similar ΔPes, whereas AL had higher ΔPL (20 [16-21] and 17 [11-20], p = 0.01, respectively). Higher ΔPL (OR = 1.5 95%CI[1-1.8], p = 0.01), positive end-expiratory pressure (OR = 2.4 95%CI[1.2-5.9], p = 0.04) and pressure support (OR = 1.8 95%CI[1.1-3.5], p = 0.03), D-dimer on admission (OR = 2.1 95%CI[1.3-9.8], p = 0.03), and features suggestive of consolidation on computed tomography scan (OR = 3.8 95%CI[1.1-15], p = 0.04) were all significantly associated with AL. A lower VFD score resulted in a higher risk (HR = 3.7 95%CI [1.2-11.3], p = 0.01) in the AL group compared with NAL. RICU stay and 90-day mortality were also higher in the AL group compared with NAL. Conclusion: In spontaneously breathing patients with COVID-19 related ARF, higher levels of ΔPL, blood D-dimer, NIV delivery pressures and a consolidative lung pattern were associated with AL onset.

5.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Article in English | MEDLINE | ID: mdl-36651370

ABSTRACT

OBJECTIVES: Prolonged air leak (PAL) is often associated with pain and immobilization and is a major limiting factor for discharge from the hospital. The efficacy of 2 surgical patches was investigated in the treatment of air leak following open surgery. METHODS: Forty-five patients were randomized in a 1:1 ratio either to treatment with Neoveil (polyglycolic acid) (n = 22) or TachoSil (collagen sponge) (n = 23). Air leak was monitored at 2, 4, 8, 12 and 24 h after surgery and then daily at 8 am and 6 pm, using a digital recording system. The primary outcome was the time to air leak closure. Secondary outcomes were incidence, air leak intensity, incidence of PAL and incidence of pneumonia. RESULTS: Air leak 2 h after surgery was observed in 11/22 (50%) vs 14/23 (61%) patients treated with polyglycolic acid, respectively, with collagen sponge. On average, air loss within the first 24 h after surgery was lower and declined faster in patients treated with polyglycolic acid. Time to pulmonary air leak closure was somewhat shorter with polyglycolic acid (median [interquartile range] 10 [2, 52] h) compared to collagen sponge (19 [2, 141] h). However, the difference was not statistically significant (P = 0.35, Wilcoxon rank-sum test). PAL occurred in 3/22 (14%) vs 6/23 (26%) patients, and pneumonia occurred in 2/22 (9%) vs 3/23 (13%) patients treated with polyglycolic acid, respectively, collagen sponge. CONCLUSIONS: Both systems are effective in the treatment of air leak. Our results suggest a possible superiority of Neoveil over TachoSil in post-surgery air leak control. CLINICAL TRIAL REGISTRATION NUMBER: NCT04065880.


Subject(s)
Collagen , Lung , Humans , Prospective Studies , Lung/surgery , Polyglycolic Acid , Pneumonectomy/methods , Postoperative Complications/etiology
6.
Adv Respir Med ; 88(1): 27-29, 2020.
Article in English | MEDLINE | ID: mdl-32153005

ABSTRACT

Persistent pulmonary air leaks are usually treated conservatively with prolonged thoracostomy tube drainage. In case this approach fails, surgical revision used to be the only option. This case report describes the successful treatment of a 66-year old patient who developped a pulmonary air leak after cardiothoracic surgery that persisted despite attempted surgical repair and talc pleurodesis. The treatment was successfully completed with endobronchial valves thereby demonstrating that treatment with endobronchial valves doesn't only represent an alternative to surgery, but that it can also be successful in case surgical intervention fails.


Subject(s)
Anastomotic Leak/surgery , Bronchoscopy/methods , Pleural Cavity/surgery , Postoperative Complications/surgery , Anastomotic Leak/etiology , Humans , Male , Middle Aged , Postoperative Complications/etiology , Prostheses and Implants , Thoracic Surgical Procedures/adverse effects , Treatment Outcome
7.
Korean J Anesthesiol ; 70(2): 217-220, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28367295

ABSTRACT

A 34-year-old woman at 25 weeks 3 days was diagnosed with preterm labor and underwent an emergency cesarean section. The neonate did not cry or show any activity. The heart rate was 80 beats/min and the oxygen saturation on pulse oximetry (SpO2) was 77%. Immediately, positive pressure ventilation was delivered by T piece resuscitator, and then anesthesiologist performed endotracheal intubation. The neonate demonstrated severe cyanosis and the SpO2 dropped to 30%. Ventilation was not successful even after intubation, and we found neck crepitus, chest wall distension, and severe cyanosis on physical examination. We suspected tension pneumothorax and performed needle thoracentesis. The neonate was stabilized and transferred to the neonatal intensive care unit for further treatment, but expired on the 10th day of life. We report a case of pulmonary air leak developing tension pneumothorax, pneumomediastinum, subcutaneous emphysema in an extremely-low-birth-weight preterm infant immediately after birth.

8.
Arch Dis Child Fetal Neonatal Ed ; 100(5): F382-7, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25854822

ABSTRACT

OBJECTIVE: The Japan Resuscitation Council (JRC) Guidelines 2010 for neonatal resuscitation introduced continuous positive airway pressure (CPAP) in delivery room. The present study evaluated the effect of CPAP for pulmonary air leak at term birth. DESIGN, SETTING AND PATIENTS: This retrospective single-centre study used the data of term neonates who were born without major congenital anomalies at our centre between 2008 and 2009, and between 2011 and 2012. INTERVENTIONS: Resuscitation according to the JRC Guidelines 2010. MAIN OUTCOME MEASURES: We examined the association between the JRC Guidelines 2010, CPAP by face mask and pulmonary air leak. RESULTS: A total of 5038 infants were analysed. The frequency of CPAP by face mask increased after the update of the JRC Guidelines in 2010 (1.7% vs 11.1%; p<0.001). Pulmonary air leak increased at early term (37 weeks: 1.0% vs 3.5%, p=0.02; 38 weeks: 0.7% vs 2.2%, p=0.02). While adjusting for confounders, the JRC Guidelines 2010 was associated with pulmonary air leak in early-term neonates (37 weeks: adjusted OR (aOR) 4.37; 95% CI 1.40 to 17.45; 38 weeks: aOR 2.80; 95% CI 1.04 to 8.91), but this association disappeared while adjusting for face mask CPAP additionally (37 weeks: aOR 1.90; 95% CI 0.47 to 8.71; 38 weeks: aOR 1.66; 95% CI 0.54 to 5.77). CONCLUSIONS: Following the update of the JRC guidelines on neonatal resuscitation, we observed an increased use of CPAP via face mask, which was associated with a higher prevalence of pulmonary air leak in early-term neonates in our centre.


Subject(s)
Continuous Positive Airway Pressure/adverse effects , Mediastinal Emphysema/etiology , Pneumothorax/etiology , Continuous Positive Airway Pressure/methods , Gestational Age , Guideline Adherence , Humans , Infant, Newborn , Masks , Practice Guidelines as Topic , Retrospective Studies
9.
Rev Port Pneumol ; 20(3): 162-6, 2014.
Article in English, Portuguese | MEDLINE | ID: mdl-24268518

ABSTRACT

Air leaks are a common problem after pulmonary resection and can be a source of significant morbidity and mortality. The authors describe the case of a 68-year-old male patient who presented with a persistent air-leak after pulmonary resection. Watchful waiting, surgical procedures, as well as medical therapy like pleurodesis and implantation of endobronchial one-way valves on the bronchial segments identified using systematic occlusion of the bronchial segments, were all tried unsuccessfully. During that time the patient remained hospitalized with a chest tube. The instillation of methylene blue through the chest tube was used to identify the segments leading to the persistent air-leak; this enabled successful endobronchial valve placement which sufficiently reduced the size of the air-leak so that the chest tube could be removed. Nonsurgical approaches seem promising and, for some patients may be the only treatment option after all conventional treatments have failed or are considered too high risk.


Subject(s)
Lung Diseases/etiology , Pneumonectomy/adverse effects , Aged , Air , Humans , Lung Diseases/diagnosis , Lung Diseases/surgery , Male
SELECTION OF CITATIONS
SEARCH DETAIL