Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters








Database
Language
Publication year range
1.
Acta Radiol ; 57(7): 829-36, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26468389

ABSTRACT

BACKGROUND: With fast computed tomography (CT), it is possible for the scanning to outpace the contrast medium bolus during aortic CT angiography (CTA). PURPOSE: To evaluate the effectiveness of a new method for reducing the risk of outpacing in which the scan start timing (ST) and speed can be estimated from the peak enhancement time measured at the femoral artery using a single test-bolus injection (femoral artery test injection method [FTI method]). MATERIAL AND METHODS: In 30 cases of aortic CTA, we measured the time to peak enhancement at the femoral artery (TPF) and the ascending aorta (TPA) with test-bolus injection performed twice in each examination. From the resultant linear relationship between TPF and transit time (TT = TPF - TPA), we developed a method for determining the ST and TT from TPF. One hundred patients were assigned to two groups: FTI and bolus tracking (BT), each with 50 patients. CT values were measured in main vessels (ascending aorta, descending aorta, femoral artery). The CT values of the vessels and the rate of cases with more than 300 HU (good cases) were compared between the two groups. RESULTS: The enhancement in the FTI method was significantly higher than that of the BT method (average CT values: FTI, 388.3 ± 52.4; BT, 281.2 ± 59.1; P < 0.001). The rates of good cases for FTI and BT were 86.0% and 46.0%, respectively. CONCLUSION: The FTI method was very effective in reducing the risk of outpacing of the contrast medium transit in aortic CTA without the need for an additional contrast medium dose.


Subject(s)
Aortic Diseases/diagnostic imaging , Computed Tomography Angiography , Contrast Media/administration & dosage , Contrast Media/pharmacokinetics , Iopamidol/administration & dosage , Iopamidol/pharmacokinetics , Adult , Aged , Aged, 80 and over , Female , Femoral Artery , Humans , Male , Middle Aged , Time Factors
2.
Eur J Radiol ; 82(9): 1373-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23726126

ABSTRACT

OBJECTIVE: The purpose of this study is to reduce the administered contrast medium volume in abdominal CTA by using a test bolus injection, with the preservation of adequate quantitative and qualitative vessel enhancement. STUDY DESIGN: For this technical efficacy study 30 patients, who were referred for a CTA examination of the abdominal aorta, were included. Randomly 15 patients were assigned to undergo a multiphasic injection protocol and received 89 mL of contrast medium (Optiray 350) (protocol I). Fifteen patients were assigned to the test bolus injection protocol (protocol II), which implies injection of a 10 mL test bolus of Optiray 350 prior to performing CTA with a 40 mL of contrast medium. Quantitative assessment of vascular enhancement was performed by measuring the amount of Hounsfield Units in the aorta at 30 positions from the celiac trunk to the iliac arteries in both groups. Qualitative assessment was performed by three radiologists who scored the images at a 5-point scale. RESULTS: Quantitative assessment showed that there was no significant difference in vascular enhancement for patients between the two protocols, with mean attenuation values of 280.9 ± 50.84 HU and 258.60 ± 39.28 HU, respectively. The image quality of protocol I was rated 4.31 (range: 3.67/5.00) and of protocol II 4.11 (range: 2.67/5.00). These differences were not statistically significant. CONCLUSION: This study showed that by using a test bolus injection and the administration of 50 mL of contrast medium overall, CTA of the abdominal aorta can reliably be performed, with regard to quantitative and qualitative adequate vessel enhancement.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/diagnostic imaging , Triiodobenzoic Acids/administration & dosage , Adult , Aged , Aged, 80 and over , Aortography , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Double-Blind Method , Female , Humans , Injections, Intravenous , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL