Results 1 - 20 de 68
Filter
1.
Abdom Radiol (NY) ; 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-39404872

ABSTRACT

PURPOSE: To assess the potential of virtual monoenergetic images in assessing colorectal liver metastasis (CRLM) compared with conventional CT images. METHODS: This single-center, retrospective study included 173 consecutive patients (mean age, 65.5 ± 10.6 years; 106 men) who underwent dual-layer spectral CT (DLSCT) between November 2016 and April 2021. Portal venous phase images were reconstructed using hybrid iterative reconstruction (iDose) and virtual monoenergetic imaging at 50 keV. Four radiologists independently and randomly reviewed the de-identified iDose and 50 keV images. Lesion detection, CRLM conspicuity, and CRLM diagnosis were compared between these images using a generalized estimating equation analysis. The reference standards used were histopathology and follow-up imaging findings. RESULTS: The study included 797 focal liver lesions, including 463 CRLMs (median size, 18.1 mm [interquartile range, 10.9-37.7 mm]). Lesion detection was better with 50 keV images than with iDose images (45.0% [95% confidence interval [CI]: 39-50] vs 40.0% [95% CI: 34-46], P = 0.003). CRLM conspicuity was higher in the 50 keV images than in the iDose images (3.27 [95% CI: 3.09-3.46] vs 3.09 [95% CI: 2.90-3.28], P < 0.001). However, the specificity for diagnosing CRLM was lower with 50 keV images than with iDose images (94.5% [95% CI: 91.6-96.4] vs 96.0% [95% CI: 93.2-98.1], P = 0.022), whereas sensitivity did not differ significantly (77.6% [95% CI: 70.3-83.5] vs 76.9% [95% CI: 70.0-82.7], P = 0.736). Indeterminate lesions were more frequently noted in 50 keV images than in iDose images (13% [445/3188] vs 9% [313/3188], P = 0.005), and 56% (247/445) of the indeterminate lesions at 50 keV were not CRLMs. CONCLUSION: The 50 keV images obtained from DLSCT were better than the iDose images in terms of CRLM conspicuity and lesion detection. However, 50 keV images did not improve CRLM diagnosis but slightly increased the reporting of indeterminate focal liver lesions associated with CRLMs.

2.
Diagnostics (Basel) ; 14(19)2024 Oct 06.
Article in English | MEDLINE | ID: mdl-39410635

ABSTRACT

Objectives: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. Materials & Methods: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. Results: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (p < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (p < 0.001) except for 50 keV (p > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60-70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. Conclusions: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40-50 keV.

3.
Radiol Med ; 2024 Sep 17.
Article in English | MEDLINE | ID: mdl-39287697

ABSTRACT

PURPOSE: Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. MATERIALS AND METHODS: A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery. RESULTS: Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) (p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01). CONCLUSIONS: Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

4.
J Clin Med ; 13(14)2024 Jul 11.
Article in English | MEDLINE | ID: mdl-39064110

ABSTRACT

Dual-Energy computed tomography (DECT) with its various advanced techniques, including Virtual Non-Contrast (VNC), effective atomic number (Z-eff) calculation, Z-maps, Iodine Density Index (IDI), and so on, holds great promise in the diagnosis and management of urogenital tumours. In this narrative review, we analyze the current status of knowledge of this technology to provide better lesion characterization, improve the staging accuracy, and give more precise treatment response assessments in relation to urological tumours.

5.
Br J Radiol ; 97(1158): 1180-1190, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38597871

ABSTRACT

OBJECTIVES: We propose a deep learning (DL) multitask learning framework using convolutional neural network for a direct conversion of single-energy CT (SECT) to 3 different parametric maps of dual-energy CT (DECT): virtual-monochromatic image (VMI), effective atomic number (EAN), and relative electron density (RED). METHODS: We propose VMI-Net for conversion of SECT to 70, 120, and 200 keV VMIs. In addition, EAN-Net and RED-Net were also developed to convert SECT to EAN and RED. We trained and validated our model using 67 patients collected between 2019 and 2020. Single-layer CT images with 120 kVp acquired by the DECT (IQon spectral CT; Philips Healthcare, Amsterdam, Netherlands) were used as input, while the VMIs, EAN, and RED acquired by the same device were used as target. The performance of the DL framework was evaluated by absolute difference (AD) and relative difference (RD). RESULTS: The VMI-Net converted 120 kVp SECT to the VMIs with AD of 9.02 Hounsfield Unit, and RD of 0.41% compared to the ground truth VMIs. The ADs of the converted EAN and RED were 0.29 and 0.96, respectively, while the RDs were 1.99% and 0.50% for the converted EAN and RED, respectively. CONCLUSIONS: SECT images were directly converted to the 3 parametric maps of DECT (ie, VMIs, EAN, and RED). By using this model, one can generate the parametric information from SECT images without DECT device. Our model can help investigate the parametric information from SECT retrospectively. ADVANCES IN KNOWLEDGE: DL framework enables converting SECT to various high-quality parametric maps of DECT.


Subject(s)
Neural Networks, Computer , Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Radiography, Dual-Energy Scanned Projection/methods , Deep Learning
6.
J Clin Med ; 13(8)2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38673712

ABSTRACT

Background/Objectives: Advancements in oral imaging technology are continually shaping the landscape of dental diagnosis and treatment planning. Among these, photon-counting computed tomography (PCCT), introduced in 2021, has emerged as a promising, high-quality oral technology. Dental imaging typically requires a resolution beyond the standard CT systems achievable with the specialized cone-beam CT. PCCT can offer up to 100 µm resolution, improve soft-tissue contrast, and provide faster scanning times, which are crucial for detailed dental diagnosis and treatment planning. Using semiconductor detectors, PCCT produces sharper images and can potentially reduce the number of scans required, thereby decreasing patient radiation exposure. This review aimed to explore the potential benefits of PCCT in dental imaging. Methods: This review analyzed the literature on PCCT in dental imaging from January 2010 to February 2024, sourced from PubMed, Scopus, and Web of Science databases, focusing on high-resolution, patient safety, and diagnostic efficiency in dental structure assessment. We included English-language articles, case studies, letters, observational studies, and randomized controlled trials while excluding duplicates and studies unrelated to PCCT's application in dental imaging. Results: Studies have highlighted the superiority of PCCT in reducing artifacts, which are often problematic, compared to conventional CBCT and traditional CT scans, due to metallic dental implants, particularly when used with virtual monoenergetic imaging and iterative metal artifact reduction, thereby improving implant imaging. This review acknowledges limitations, such as the potential for overlooking other advanced imaging technologies, a narrow study timeframe, the lack of real-world clinical application data in this field, and costs. Conclusions: PCCT represents a promising advancement in dental imaging, offering high-resolution visuals, enhanced contrast, and rapid scanning with reduced radiation exposure.

7.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38535045

ABSTRACT

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

8.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38535047

ABSTRACT

BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.

9.
Cancers (Basel) ; 16(6)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38539562

ABSTRACT

This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772-0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.

10.
J Endovasc Ther ; : 15266028241230943, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38380529

ABSTRACT

PURPOSE: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector-CT (PCD-CT) in comparison with an energy-integrating detector-CT (EID-CT), with a special focus on low-contrast attenuation. METHODS: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. RESULTS: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. CONCLUSION: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. CLINICAL IMPACT: ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.

11.
Abdom Radiol (NY) ; 49(1): 103-116, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37796327

ABSTRACT

PURPOSE: To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). METHODS: Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). RESULTS: Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. CONCLUSION: PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Radiography, Dual-Energy Scanned Projection , Male , Humans , Aged , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms/diagnostic imaging , Carcinoma, Pancreatic Ductal/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
12.
Acad Radiol ; 31(6): 2501-2510, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38135625

ABSTRACT

RATIONALE AND OBJECTIVES: To investigate the feasibility of virtual monochromatic imaging (VMI) of dual-layer spectral detector computed tomography (SDCT) to reduce iodinated contrast material (CM) and radiation dose in craniocervical computed tomography angiography (CTA). MATERIALS AND METHODS: A total of 280 consecutively selected patients performed craniocervical CTA with SDCT were prospectively selected and randomly divided into four groups (A, DoseRight index (DRI) 31, iopromide 370mgI/mL, volume 0.8 mL/kg; B, DRI 26, iopromide 370mgI/mL, volume 0.4 mL/kg; C, DRI 26, ioversol 320mgI/mL, volume 0.4 mL/kg; D, DRI 26, iohexol 300mgI/mL, volume 0.4 mL/kg). 50-70 kiloelectron volts (keV) VMIs in group B were reconstructed and compared to group A to select the optimal keV. Then, the optimal keV in groups B, C and D was reconstructed and compared. Objective image quality, including vascular attenuation, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), was evaluated. Subjective image quality was assessed using a 5-point Likert scale. In addition, the effective dose (ED), iodine load and iodine delivery rate (IDR) were compared between groups A and D. RESULTS: 55 keV VMI was the optimal VMI in group B. The objective and subjective image quality of 55 keV VMI in group B were equal to or better than those of the CI in group A. The SNR, CNR and subjective image quality in group D were similar to those in group B (P > 0.05). The ED, iodine load and IDR of group D were reduced by 44%, 59% and 19%, respectively, when compared to those of group A. CONCLUSION: Low dose iodinated CM and radiation for 55 keV VMI in craniocervical CTA using SDCT could still provide equivalent or better image quality than the conventional scanning protocol.


Subject(s)
Computed Tomography Angiography , Contrast Media , Feasibility Studies , Iohexol , Radiation Dosage , Humans , Male , Female , Prospective Studies , Middle Aged , Computed Tomography Angiography/methods , Iohexol/analogs & derivatives , Aged , Triiodobenzoic Acids , Adult , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods
13.
Eur J Radiol Open ; 11: 100538, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38028186

ABSTRACT

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa-statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (κ = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p ≤ 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images. Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.

14.
Insights Imaging ; 14(1): 181, 2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37880460

ABSTRACT

OBJECTIVES: To investigate the optimal parameters of spectral CT for preferably visualizing the periprosthetic vasculature and metal artifact reduction (MAR) in total hip arthroplasty (THA). METHODS: A total of 34 THA of 30 patients were retrospectively included. Image reconstructions included conventional image (CI), CI combined with MAR (CIMAR), and virtual monoenergetic images (VMI) combined with MAR (VMIMAR) at 50-120 keV. The attenuation and standard deviation of the vessel and artifact, and the width of artifact were measured. Qualitative scoring was evaluated including the vascular contour, the extent of artifact, and overall diagnostic evaluation. RESULTS: The attenuation, noise of the vessel and artifact, and the width of artifact decreased as the energy level increased (p < 0.001). The downtrend was relatively flat at 80-120 keV, and the vascular attenuation dropped to 200 HU at 90 keV. The qualitative rating of vascular contour was significantly higher at CIMAR (3.47) and VMIMAR 60-80 keV (2.82-3.65) compared with CI (2.03) (p ≤ 0.029), and the highest score occurred at 70 and 80 keV (3.65 and 3.56). The score of the extent of artifact was higher at VMIMAR 80 keV than CIMAR (3.53 VS 3.12, p = 0.003). The score of the overall diagnostic evaluation was higher at VMIMAR 70 and 80 keV (3.32 and 3.53, respectively) than CIMAR (3.12) (p ≤ 0.035). CONCLUSION: Eighty kiloelectron volts on VMIMAR, providing satisfactorily reduced metal artifacts and improved vascular visualization, can be an optimal recommended parameter of spectrum CT for the assessment of periprosthetic vasculature in THA patients. CRITICAL RELEVANCE STATEMENT: The metal artifact is gradually reducing with increasing energy level; however, the vascular visualization is worsening. The vascular visualization is terrible above 100 keV, while the vessel is disturbed by artifacts below 70 keV. The best performance is found at 80 keV. KEY POINTS: • VMIMAR can provide both reduced metal artifacts and improved vascular visualization. • Eighty kiloelectron volts on VMIMAR performs best in vascular visualization of total hip arthroplasty patients. • Energy spectrum CT is recommended for routine use in patients with total hip arthroplasty.

15.
Clin Imaging ; 102: 109-115, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37672849

ABSTRACT

PURPOSE: Advantages of virtual monoenergetic images (VMI) have been reported for dual energy CT of the head and neck, and more recently VMIs derived from photon-counting (PCCT) angiography of the head and neck. We report image quality metrics of VMI in a PCCT angiography dataset, expanding the anatomical regions evaluated and extending observer-based qualitative methods further than previously reported. METHODS: In a prospective study, asymptomatic subjects underwent contrast enhanced PCCT of the head and neck using an investigational scanner. Image sets of low, high, and full spectrum (Threshold-1) energies; linear mix of low and high energies (Mix); and 23 VMIs (40-150 keV, 5 keV increments) were generated. In 8 anatomical locations, SNR and radiologists' preferences for VMI energy levels were measured using a forced-choice rank method (4 observers) and ratings of image quality using visual grading characteristic (VGC) analysis (2 observers) comparing VMI to Mix and Threshold-1 images. RESULTS: Fifteen subjects were included (7 men, 8 women, mean 57 years, range 46-75). Among all VMIs, SNRs varied by anatomic location. The highest SNRs were observed in VMIs. Radiologists preferred 50-60 keV VMIs for vascular structures and 75-85 keV for all other structures. Cumulative ratings of image quality averaged across all locations were higher for VMIs with areas under the curve of VMI vs Mix and VMI vs Threshold-1 of 0.67 and 0.68 for the first reader and 0.72 and 0.76 for the second, respectively. CONCLUSION: Preferred keV level and quality ratings of VMI compared to mixed and Threshold-1 images varied by anatomical location.


Subject(s)
Head , Neck , Male , Female , Humans , Prospective Studies , Head/diagnostic imaging , Neck/diagnostic imaging , Tomography, X-Ray Computed , Angiography
16.
Eur J Radiol ; 166: 111008, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37542817

ABSTRACT

PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.


Subject(s)
Coronary Vessels , Tomography, X-Ray Computed , Humans , Male , Female , Coronary Vessels/diagnostic imaging , Tomography, X-Ray Computed/methods , Computed Tomography Angiography/methods , Heart , Photons , Phantoms, Imaging
17.
Radiother Oncol ; 187: 109840, 2023 10.
Article in English | MEDLINE | ID: mdl-37536377

ABSTRACT

BACKGROUND: Objective and subjective assessment of image quality of brain metastases on dual-energy computed tomography (DECT) virtual monoenergetic imaging (VMI) and its impact on target volume delineation. MATERIALS AND METHODS: 26 patients with 37 brain metastases receiving Magnetic Resonance Imaging (MRI) and DECT for stereotactic radiotherapy planning were included in this retrospective analysis. Lesion contrast (LC), contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed for reconstructed VMI at 63 keV and artificial 120 kV Computed Tomography (CT). Image contrast and demarcation of metastases between 120 kV CT, VMI and MRI were subjectively assessed. Brain metastases were delineated by four radiation oncologists on VMI with a fixed or free brain window and contours were compared to solely MRI-based delineation using the Dice similarity coefficient. RESULTS: LC, CNR and SNR were significantly higher in VMI than in 120 kV CT (p < 0.0001). Image contrast and lesion demarcation were significantly better on VMI compared to 120 kV CT (p < 0.0001). Mean gross tumor volume (GTV)/planning target volume (PTV) Dice similarity coefficients were 0.87/0.9 for metastases without imaging uncertainties (no artifacts, calcification or impaired visibility with MRI) but worse for metastases with imaging uncertainties (0.71/0.74). Target volumes delineated on VMI were around 5-10% smaller compared to MRI. CONCLUSION: Image quality of VMI is objectively and subjectively superior to conventional CT. VMI provides significant advantages in stereotactic radiotherapy planning with improved visibility of brain metastases and geometrically distortion-free representation of brain metastases. Beside a plausibility check of MRI-based target volume delineation, VMI might improve reliability and accuracy in target volume definition particularly in cases with imaging uncertainties with MRI.


Subject(s)
Brain Neoplasms , Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Reproducibility of Results , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Radiographic Image Interpretation, Computer-Assisted/methods
18.
Eur J Radiol ; 165: 110946, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37399668

ABSTRACT

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.


Subject(s)
Artifacts , Tomography, X-Ray Computed , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Spine/diagnostic imaging , Spine/surgery , Metals , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio
19.
PeerJ ; 11: e15707, 2023.
Article in English | MEDLINE | ID: mdl-37483982

ABSTRACT

Objectives: To assess the performance of 3D Res-UNet for fully automated segmentation of esophageal cancer (EC) and compare the segmentation accuracy between conventional images (CI) and 40-keV virtual mono-energetic images (VMI40 kev). Methods: Patients underwent spectral CT scanning and diagnosed of EC by operation or gastroscope biopsy in our hospital from 2019 to 2020 were analyzed retrospectively. All artery spectral base images were transferred to the dedicated workstation to generate VMI40 kev and CI. The segmentation model of EC was constructed by 3D Res-UNet neural network in VMI40 kev and CI, respectively. After optimization training, the Dice similarity coefficient (DSC), overlap (IOU), average symmetrical surface distance (ASSD) and 95% Hausdorff distance (HD_95) of EC at pixel level were tested and calculated in the test set. The paired rank sum test was used to compare the results of VMI40 kev and CI. Results: A total of 160 patients were included in the analysis and randomly divided into the training dataset (104 patients), validation dataset (26 patients) and test dataset (30 patients). VMI40 kevas input data in the training dataset resulted in higher model performance in the test dataset in comparison with using CI as input data (DSC:0.875 vs 0.859, IOU: 0.777 vs 0.755, ASSD:0.911 vs 0.981, HD_95: 4.41 vs 6.23, all p-value <0.05). Conclusion: Fully automated segmentation of EC with 3D Res-UNet has high accuracy and clinically feasibility for both CI and VMI40 kev. Compared with CI, VMI40 kev indicated slightly higher accuracy in this test dataset.


Subject(s)
Esophageal Neoplasms , Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Radiography, Dual-Energy Scanned Projection/methods , Arteries , Esophageal Neoplasms/diagnostic imaging
20.
J Appl Clin Med Phys ; 24(10): e14062, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37312288

ABSTRACT

OBJECTIVE: The stopping power ratio (SPR) prediction error will contribute to the range uncertainty of proton therapy. Spectral CT is promising in reducing the uncertainty in SPR estimation. The purpose of this research is to determine the optimal energy pairs of SPR prediction for each tissue and to evaluate the dose distribution and range difference between the spectral CT with the optimal energy pairs method and the single energy CT (SECT) method. METHODS: A new method was proposed based on image segmentation to calculate the proton dose with spectral CT images for the head and body phantom. CT number of each organ region were converted to SPR with the optimal energy pairs of each organ. The CT images were segmented into different organ parts with thresholding method. Virtual monoenergetic (VM) images from 70 keV to 140 keV were investigated to determine the optimal energy pairs for each organ based on Gammex 1467 phantom. The beam data of Shanghai Advanced Proton Therapy facility (SAPT) was employed in matRad (an open-source software for radiation treatment planning) for the dose calculation. RESULTS: The optimal energy pairs were obtained for each tissue. The dose distribution of two tumor sites (brain and lung) were calculated with the aforementioned optimal energy pairs. The maximum dose deviation between spectral CT and SECT at the target region was 2.57% and 0.84% for the lung tumor and brain tumor respectively. The range difference between spectral and SECT was significant with 1.8411 mm for the lung tumor. γ passing rate was 85.95% and 95.49% for the lung tumor and brain tumor with the criterion 2%/2 mm. CONCLUSIONS: This work presents a way to determine the optimal energy pairs for each organ and to calculate the dose distribution based on the more accurate SPR prediction.


Subject(s)
Brain Neoplasms , Lung Neoplasms , Proton Therapy , Humans , Protons , Uncertainty , Tomography, X-Ray Computed/methods , China , Proton Therapy/methods , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Phantoms, Imaging , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy