Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 19.046
Filter
1.
EuroIntervention ; 20(13): e793-e805, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949240

ABSTRACT

Periprocedural stroke after transcatheter aortic valve implantation (TAVI) remains a significant issue, which is associated with high morbidity, and is increasingly important as intervention shifts to younger and lower-risk populations. Over the last decade of clinical experience with TAVI, the incidence of periprocedural stroke has stayed largely unchanged, although it is prone to underreporting due to variation in ascertainment methods. The aetiology of stroke in TAVI patients is multifactorial, and changing risk profiles, differing study populations, and frequent device iterations have made it difficult to discern consistent risk factors. The objective of this review is to analyse and clarify the contemporary published literature on the epidemiology and mechanisms of neurological events in TAVI patients and evaluate potential preventive measures. This summary aims to improve patient risk assessment and refine case selection for cerebral embolic protection devices, while also providing a foundation for designing future trials focused on stroke prevention.


Subject(s)
Aortic Valve Stenosis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Stroke/etiology , Stroke/prevention & control , Aortic Valve Stenosis/surgery , Risk Assessment , Aortic Valve/surgery , Incidence , Treatment Outcome , Embolic Protection Devices
2.
Aust J Gen Pract ; 53(7): 444-448, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38957057

ABSTRACT

BACKGROUND: Aortic stenosis (AS) remains one of the most commonly encountered valvular pathologies. Medical management does not alter the progression of the disease, making assessment of severity and timing of referral for valve replacement the most important aspects of caring for patients with AS. OBJECTIVE: To review the contemporary management of AS, including signs and symptoms, echocardiography and decision making in management. DISCUSSION: Severe symptomatic AS is frequently accompanied by dyspnoea, chest pain or syncope and a physical examination might reveal the presence of an ejection systolic murmur. Echocardiography is the first and most useful investigation to stratify risk and determine requirement for valve replacement by assessing valve gradients and left ventricular function. Surgical and transcatheter options now exist for treatment of AS and decision making is usually multidisciplinary and based on individual patient parameters.


Subject(s)
Aortic Valve Stenosis , Echocardiography , Humans , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/therapy , Echocardiography/methods
3.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866455

ABSTRACT

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
6.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866457

ABSTRACT

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Subject(s)
Aortic Valve , Calcinosis , Heart Valve Prosthesis , Hydrodynamics , Prosthesis Design , Prosthesis Failure , Registries , Transcatheter Aortic Valve Replacement , X-Ray Microtomography , Humans , Aged , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/pathology , Calcinosis/physiopathology , Calcinosis/diagnostic imaging , Calcinosis/pathology , Calcinosis/surgery , Female , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Middle Aged , Time Factors , Device Removal , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Hemodynamics , Biomechanical Phenomena , Materials Testing , Video Recording
7.
Cardiol Rev ; 32(4): 320-327, 2024.
Article in English | MEDLINE | ID: mdl-38848535

ABSTRACT

Calcified aortic stenosis (AS) is one of the most common valvular heart diseases worldwide, characterized by progressive fibrocalcific remodeling and thickening of the leaflets, which ultimately leads to obstruction of blood flow. Its pathobiology is an active and complicated process, involving endothelial cell dysfunction, lipoprotein deposition and oxidation, chronic inflammation, phenotypic transformation of valve interstitial cells, neovascularization, and intravalvular hemorrhage. To date, no targeted drug has been proven to slow down or prevent disease progression. Aortic valve replacement is still the optimal treatment of AS. This article reviews the etiology, diagnosis, and management of calcified aortic stenosis and proposes novel potential therapeutic targets.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Calcinosis/therapy , Aortic Valve/pathology , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods
8.
Arq Bras Cardiol ; 121(5): e20230467, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38896588

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has established itself as the preferential strategy to approach severe aortic stenosis. Information on procedural improvements and nationwide results obtained with the technique throughout the past decade are unknown. OBJECTIVES: To assess the temporal variation of the demographic profile, procedural characteristics, and in-hospital outcomes of patients undergoing TAVI procedures at the Rede D'Or São Luiz. METHODS: Observational registry comprising 29 national institutions, comparing the characteristics of the TAVI procedures performed from 2012 to 2017 (Group 1) to those performed from 2018 to 2023 (Group 2). The statistical significance level adopted was p < 0.05. RESULTS: This study assessed 661 patients, 95 in Group 1 and 566 in Group 2, with a mean age of 81.1 years. Group 1 patients had a higher prevalence of New York Heart Association functional class III or IV and STS risk score > 8%. In addition, they more often underwent general anesthesia, transesophageal echocardiographic monitoring, and access through femoral dissection. Group 2 patients had a higher success rate of the TAVI procedure (95.4% versus 89.5%; p = 0.018), lower mortality (3.9% versus 11.6%; p = 0.004), and less often needed permanent pacemaker implantation (8.5% versus 17.9%; p = 0.008). CONCLUSIONS: The 10-year temporal trends analysis of the TAVIDOR Registry shows a reduction in patients' clinical complexity over time. Furthermore, the advance to minimalistic implantation techniques, added to the technological evolution of the devices, may have contributed to the favorable outcomes observed among those whose implantation occurred in the last 5 years studied.


FUNDAMENTO: O implante percutâneo de bioprótese valvar aórtica (TAVI) consolidou-se como opção terapêutica da estenose aórtica de grau importante. Dados sobre as características evolutivas dos procedimentos e dos resultados obtidos com a técnica ao longo da última década, em escala nacional, são desconhecidos. OBJETIVOS: Analisar a tendência temporal referente ao perfil demográfico, características dos procedimentos e desfechos hospitalares de pacientes submetidos a TAVI na Rede D'Or São Luiz. MÉTODOS: Registro observacional envolvendo 29 instituições nacionais. Comparou-se características dos procedimentos realizados de 2012 a 2017 (Grupo 1) e de 2018 a 2023 (Grupo 2). Foram considerados significantes os resultados com valor de p < 0,05. RESULTADOS: Foram analisados 661 casos, 95 pertencentes ao Grupo 1 e 566 ao Grupo 2. A média de idade foi 81,1 anos. Observou-se no Grupo 1 maior prevalência de pacientes em classe funcional III ou IV e escore de risco > 8%. Foi mais frequente o emprego de anestesia geral, monitorização ecocardiográfica transesofágica e via de acesso por dissecção. Maior taxa de sucesso do procedimento (95,4% versus 89,5%; p = 0,018) foi aferida em implantes efetivados a partir de 2018, assim como menor mortalidade (3,9% versus 11,6%; p = 0,004) e necessidade de marcapasso definitivo (8,5% versus 17,9%; p = 0,008). CONCLUSÕES: A análise temporal de 10 anos do Registro TAVIDOR demonstra uma queda na complexidade clínica dos pacientes. Além disso, o avanço para técnicas de implante minimalistas, somadas à evolução tecnológica dos dispositivos, podem ter contribuído para desfechos favoráveis dentre aqueles cujo implante ocorreu no último quinquênio.


Subject(s)
Aortic Valve Stenosis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/trends , Male , Female , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aged , Treatment Outcome , Time Factors , Risk Factors , Brazil/epidemiology , Hospital Mortality
9.
J Cardiothorac Surg ; 19(1): 349, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907320

ABSTRACT

BACKGROUND: Observational studies have shown reduced perioperative bleeding in patients undergoing minimally invasive, compared with full sternotomy, aortic valve replacement. Data from randomized trials are conflicting. METHODS: This was a Swedish single center study where adult patients with aortic stenosis, 100 patients were randomly assigned in a 1:1 ratio to undergo either minimally invasive (ministernotomy) or full sternotomy aortic valve replacement. The primary outcome was severe or massive bleeding defined by the Universal Definition of Perioperative Bleeding in adult cardiac surgery (UDPB). Secondary outcomes included blood product transfusions, chest tube output, re-exploration for bleeding, and several other clinically relevant events. RESULTS: Out of 100 patients, three patients randomized to ministernotomy were intraoperatively converted to full sternotomy (none was bleeding-related). Three patients (6%) in the full sternotomy group and 3 patients (6%) in the ministernotomy group suffered severe or massive postoperative bleeding according to the UDPB definition (p = 1.00). Mean chest tube output during the first 12 postoperative hours was 350 (standard deviation (SD) 220) ml in the full sternotomy group and 270 (SD 190) ml in the ministernotomy group (p = 0.08). 28% of patients in the full sternotomy group and 36% of patients in the ministernotomy group received at least one packed red blood cells transfusion (p = 0.39). Two patients in each group (4%) underwent re-exploration for bleeding. CONCLUSIONS: Minimally invasive aortic valve replacement did not result in less bleeding-related outcomes compared to full sternotomy. CLINICAL TRIAL REGISTRATION: http://www. CLINICALTRIALS: gov . Unique identifier: NCT02272621.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Minimally Invasive Surgical Procedures , Postoperative Hemorrhage , Sternotomy , Humans , Male , Female , Minimally Invasive Surgical Procedures/methods , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Aged , Sternotomy/methods , Sternotomy/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Aged, 80 and over , Sweden , Middle Aged , Treatment Outcome , Blood Loss, Surgical/prevention & control
10.
BMC Anesthesiol ; 24(1): 209, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907200

ABSTRACT

BACKGROUND: We used transcatheter aortic valve implantation (TAVI) procedure time to investigate the association between surgical team maturity and outcome. METHODS: Among patients who underwent TAVI between October 2015 and November 2019, those who had Sapien™ implanted with the transfemoral artery approach were included in the analysis. We used TAVI procedure time and surgery number to draw a learning curve. Then, we divided the patients into two groups before and after the number of cases where the sigmoid curve reaches a plateau. We compared the two groups regarding the surveyed factors and investigated the correlation between the TAVI procedure time and survey factors. RESULTS: Ninety-nine of 149 patients were analysed. The sigmoid curve had an inflection point in 23.2 cases and reached a plateau in 43.0 cases. Patients in the Late group had a shorter operating time, less contrast media, less radiation exposure, and less myocardial escape enzymes than the Early group. Surgical procedure time showed the strongest correlation with the surgical case number. CONCLUSION: The number of cases required for surgeon proficiency for isolated Sapien™ valve implantation was 43. This number may serve as a guideline for switching the anesthesia management of TAVI from general to local anesthesia.


Subject(s)
Learning Curve , Operative Time , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Male , Female , Aged, 80 and over , Aged , Clinical Competence , Treatment Outcome , Aortic Valve Stenosis/surgery
11.
BMC Cardiovasc Disord ; 24(1): 314, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907344

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established treatment for high and intermediate-risk patients with severe aortic stenosis (AS). Recent studies have demonstrated non-inferiority of TAVI compared to surgery in low-risk patients. In the past decade, numerous literature reviews (SLRs) have assessed the use of TAVI in different risk groups. This is the first attempt to provide an overview of SRs (OoSRs) focusing on secondary studies reporting clinical outcomes/process indicators. This research aims to summarize the findings of extant literature on the performance of TAVI over time. METHODS: A literature search took place from inception to April 2024. We searched MEDLINE and the Cochrane Library for SLRs. SLRs reporting at least one review of clinical indicators were included. Subsequently, a two-step inclusion process was conducted: [1] screening based on title and abstracts and [2] screening based on full-text papers. Relevant data were extracted and the quality of the reviews was assessed. RESULTS: We included 33 SLRs with different risks assessed via the Society of Thoracic Surgeons (STS) score. Mortality rates were comparable between TAVI and Surgical Aortic Valve Replacement (SAVR) groups. TAVI is associated with lower rates of major bleeding, acute kidney injury (AKI) incidence, and new-onset atrial fibrillation. Vascular complications, pacemaker implantation, and residual aortic regurgitation were more frequent in TAVI patients. CONCLUSION: This study summarizes TAVI performance findings over a decade, revealing a shift to include both high and low-risk patients since 2020. Overall, TAVI continues to evolve, emphasizing improved outcomes, broader indications, and addressing challenges.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Risk Factors , Treatment Outcome , Risk Assessment , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Postoperative Complications/etiology , Postoperative Complications/mortality , Time Factors , Systematic Reviews as Topic
12.
Cardiol Clin ; 42(3): 333-338, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910018

ABSTRACT

Patients with concomitant severe aortic stenosis and significant coronary artery disease present a diagnostic and therapeutic challenge in clinical practice. There are no clear-cut guidelines as to the timing of revascularization in these patients who are referred for transcatheter aortic valve replacement (TAVR). This article aims to show that in patients without high-grade proximal coronary artery disease, revascularization after TAVR is safe, feasible, and practical. Additionally, the use of preoperative TAVR computed tomographic angiography might be used in both intermediate and high-risk patients rather than invasive coronary angiography to assess for significant proximal coronary artery disease to help guide the timing of revascularization.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Coronary Artery Disease/surgery , Coronary Artery Disease/diagnosis , Coronary Angiography , Myocardial Revascularization/methods , Percutaneous Coronary Intervention/methods
13.
Cardiol Clin ; 42(3): 361-371, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910021

ABSTRACT

Coronary artery obstruction is a rare complication of transcatheter aortic valve replacement (TAVR). This risk increases in TAVR-valve-in-valve procedure. Several anatomic risk factors were described in many studies to identify the predictive elements of coronary artery occlusion on computed tomography cardiac scan. Rescue percutaneous coronary intervention was the first approach described to treat this complication with a high mortality rate. Later on, preventive chimney stenting technique was evaluated and results showed that is a safe and effective strategy but it leads to a difficult coronary access later. New preventive techniques are being evaluated recently (Basilica and Shorctut).


Subject(s)
Aortic Valve Stenosis , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Postoperative Complications/prevention & control , Postoperative Complications/epidemiology , Coronary Occlusion/surgery , Coronary Occlusion/diagnosis , Coronary Occlusion/etiology , Risk Assessment/methods , Coronary Angiography/methods , Global Health
14.
Cardiol Clin ; 42(3): 373-387, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910022

ABSTRACT

Self-expanding valves (SEV) and balloon-expandable valves (BEV) for transcatheter aortic valve implantation (TAVI) have their own features. There is a growing interest in long-term outcomes with the adoption of lifetime management in younger patients. To evaluate late outcomes in TAVI with SEV versus BEV, we performed a study-level meta-analysis of reconstructed time-to-event data published by May 31, 2023. We found no statistically significant difference in all-cause death after TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Treatment Outcome , Time Factors
15.
JMIR Mhealth Uhealth ; 12: e53964, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38832585

ABSTRACT

Background: Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks. Currently, we are not able to adequately predict functional outcomes after TAVI. Quality of life measurement tools and traditional functional assessment tests do not always agree and can depend on factors unrelated to heart disease. Activity tracking using wearable devices might provide a more comprehensive assessment. Objective: This study aimed to identify objective parameters (eg, change in heart rate) associated with improvement after TAVI for severe aortic stenosis from a wearable device. Methods: In total, 100 patients undergoing routine TAVI wore a Philips Health Watch device for 1 week before and after the procedure. Watch data were analyzed offline-before TAVI for 97 patients and after TAVI for 75 patients. Results: Parameters such as the total number of steps and activity time did not change, in contrast to improvements in the 6-minute walking test (6MWT) and physical limitation domain of the transformed WHOQOL-BREF questionnaire. Conclusions: These findings, in an older TAVI population, show that watch-based parameters, such as the number of steps, do not change after TAVI, unlike traditional 6MWT and QoL assessments. Basic wearable device parameters might be less appropriate for measuring treatment effects from TAVI.


Subject(s)
Transcatheter Aortic Valve Replacement , Wearable Electronic Devices , Humans , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/statistics & numerical data , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Prospective Studies , Wearable Electronic Devices/statistics & numerical data , Wearable Electronic Devices/standards , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Surveys and Questionnaires , Quality of Life/psychology
16.
A A Pract ; 18(6): e01795, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38836558

ABSTRACT

Patients undergoing transcatheter aortic valve replacement (TAVR) as a bridge to noncardiac surgery have improved outcomes. Older clinical trials concluded no increased risk of performing noncardiac surgery within 30 days of the TAVR procedure. Emerging evidence suggests patients with preexisting conduction abnormalities may require additional intervention to proceed safely with noncardiac surgery. More data are needed to clarify this clinical situation, especially for the anesthesiologist whose job is to mitigate risk for these patients. We present a patient who received a TAVR and suffered associated complications during subsequent surgery. We further discuss preventative measures and perioperative considerations for this patient population.


Subject(s)
Aortic Valve Stenosis , Heart Block , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aged, 80 and over , Heart Block/etiology , Male , Female , Postoperative Complications/prevention & control , Postoperative Complications/etiology
17.
Echocardiography ; 41(6): e15859, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853624

ABSTRACT

Aortic stenosis (AS) stands as the most common valvular heart disease in developed countries and is characterized by progressive narrowing of the aortic valve orifice resulting in elevated transvalvular flow resistance, left ventricular hypertrophy, and progressive increased risk of heart failure and sudden death. This narrative review explores clinical challenges and evolving perspectives in moderate AS, where discrepancies between aortic valve area and pressure gradient measurements may pose diagnostic and therapeutic quandaries. Transthoracic echocardiography is the first-line imaging modality for AS evaluation, yet cases of discordance may require the application of ancillary noninvasive diagnostic modalities. This review underscores the importance of accurate grading of AS severity, especially in low-gradient phenotypes, emphasizing the need for vigilant follow-up. Current clinical guidelines primarily recommend aortic valve replacement for severe AS, potentially overlooking latent risks in moderate disease stages. The noninvasive multimodality imaging approach-including echocardiography, cardiac magnetic resonance, computed tomography, and nuclear techniques-provides unique insights into adaptive and maladaptive cardiac remodeling in AS and offers a promising avenue to deliver precise indications and exact timing for intervention in moderate AS phenotypes and asymptomatic patients, potentially improving long-term outcomes. Nevertheless, what we may have gleaned from a large amount of observational data is still insufficient to build a robust framework for clinical decision-making in moderate AS. Future research will prioritize randomized clinical trials designed to weigh the benefits and risks of preemptive aortic valve replacement in the management of moderate AS, as directed by specific imaging and nonimaging biomarkers.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Echocardiography , Humans , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Echocardiography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Severity of Illness Index
19.
Korean J Radiol ; 25(7): 634-643, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38942457

ABSTRACT

OBJECTIVE: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. MATERIALS AND METHODS: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. RESULTS: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. CONCLUSION: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.


Subject(s)
Contrast Media , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aged, 80 and over , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Tomography, X-Ray Computed/methods , Aged , Acute Kidney Injury/etiology , Acute Kidney Injury/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Radiography, Dual-Energy Scanned Projection/methods , Radiation Dosage , Reproducibility of Results , Renal Insufficiency , Retrospective Studies , Signal-To-Noise Ratio
20.
Int J Mol Sci ; 25(12)2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38928127

ABSTRACT

Valvular disease is a complex pathological condition that impacts countless individuals around the globe. Due to limited treatments, it is crucial to understand its mechanisms to identify new targets. Valve disease may result in pulmonary venous hypertension, which is linked to compromised functioning of the alveolar and capillary membranes and hindered gas exchange. Nonetheless, the correlation between surfactant proteins (SPs) and valve disease remains unexplored. A total of 44 patients were enrolled in this study, with 36 undergoing aortic valve replacement and 8 needing a second aortic valve substitution due to bioprosthetic valve degeneration. Ten healthy subjects were also included. The results showed that patients who underwent both the first valve replacement and the second surgery had significantly higher levels of immature SP-B (proSP-B) compared to control subjects. The levels of the extra-lung collectin SP-D were higher in patients who needed a second surgery due to bioprosthetic valve degeneration, while SP-A levels remained unchanged. The research also showed that there was no reciprocal relationship between inflammation and SP-D as the levels of inflammatory mediators did not differ between groups. The present study demonstrates that circulating proSP-B serves as a reliable marker of alveolar-capillary membrane damage in patients with valvular heart disease.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Pulmonary Surfactant-Associated Protein B , Humans , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/surgery , Male , Female , Pulmonary Surfactant-Associated Protein B/blood , Pulmonary Surfactant-Associated Protein B/metabolism , Aged , Calcinosis/blood , Aortic Valve/surgery , Aortic Valve/pathology , Middle Aged , Biomarkers/blood , Case-Control Studies
SELECTION OF CITATIONS
SEARCH DETAIL