Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.201
Filter
1.
Pediatr Surg Int ; 40(1): 128, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722444

ABSTRACT

INTRODUCTION: Continuous ambulatory peritoneal dialysis is an important modality of renal replacement therapy in children. Catheter dysfunction (commonly obstruction) is a major cause of morbidity and is a significant concern that hampers renal replacement therapy. As omentum is a significant cause of obstruction, some recommend routine omentectomy during insertion of the peritoneal dialysis catheter. Omentopexy rather than omentectomy has been described in adults to spare the omentum as it may be needed as a spare part in many conditions. Laparoscopic approach is commonly preferred as it provides global evaluation of the peritoneal space, proper location of the catheteral end in the pelvis and lesser morbidity due to inherent minimally invasive nature. AIM: The aim of this study is to present the technique of laparoscopic peritoneal dialysis catheter placement in children with concurrent omentopexy. METHODS: We retrospectively evaluated our patients who underwent laparoscopic placement of peritoneal dialysis catheter with concomitant omentopexy or omentectomy. RESULTS: A total of 30 patients were enrolled who received either omentectomy (n = 18) or omentopexy (n = 12). Four catheters were lost in the omentopexy group (33%) and 3 in the omentectomy group (17%), but none were related to omental obstruction. Three out of 4 patients in the omentopexy group and 2 out of 3 patients in the omentectomy group had a previous abdominal operation as a potential cause of catheter loss. Previous history of abdominal surgery was present in 6 patients (50%) in the omentopexy group and 3 patients (17%) in the omentectomy group. CONCLUSIONS: As omentum was associated with catheter failure, omentectomy is commonly recommended. Alternatively, omentopexy can be preferred in children to spare an organ that may potentially be necessary for many surgical reconstructive procedures in the future. Laparoscopic peritoneal dialysis catheter placement with concomitant omentopexy appears as a feasable and reproducible technique. Although the catheter loss seems to be higher in the omentopexy group, none was related with the omentopexy procedure and may be related to the higher rate of history of previous abdominal operations in this group.


Subject(s)
Laparoscopy , Omentum , Humans , Omentum/surgery , Laparoscopy/methods , Retrospective Studies , Male , Female , Child , Child, Preschool , Catheterization/methods , Adolescent , Catheters, Indwelling , Peritoneal Dialysis/methods , Peritoneal Dialysis, Continuous Ambulatory/methods , Infant , Treatment Outcome
2.
Article in English | MEDLINE | ID: mdl-38696241

ABSTRACT

In this video tutorial, we present the cannulation technique for venopulmonary extracorporeal membrane oxygenation using the ProtekDuo dual-lumen cannula in a patient with acute respiratory distress syndrome.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Humans , Extracorporeal Membrane Oxygenation/methods , Respiratory Distress Syndrome/therapy , Catheterization/methods , Male
3.
Anesthesiol Clin ; 42(2): 317-328, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38705679

ABSTRACT

Continuous peripheral nerve block catheters are simple in concept: percutaneously inserting a catheter adjacent to a peripheral nerve. This procedure is followed by local anesthetic infusion via the catheter that can be titrated to effect for extended anesthesia or analgesia in the perioperative period. The reported benefits of peripheral nerve catheters used in the surgical population include improved pain scores, decreased narcotic use, decreased nausea/vomiting, decreased pruritus, decreased sedation, improved sleep, and improved patient satisfaction.


Subject(s)
Catheters , Nerve Block , Humans , Anesthetics, Local/administration & dosage , Catheterization/methods , Nerve Block/methods , Peripheral Nerves
5.
Ren Fail ; 46(1): 2349123, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38727002

ABSTRACT

BACKGROUND: Laparoscopic techniques are being widely applied for peritoneal dialysis (PD) catheter (PDC) placement. The suture passer is a novel fixation tool that aims to reduce catheter migration. We compared the clinical value of the suture passer combined with two-hole laparoscopic PDC placement to open surgical placement by evaluating preoperative and postoperative conditions, as well as the onset of complications in both groups. METHODS: A retrospective study was conducted including 169 patients who underwent PDC placement surgery from January 2021 to May 2023. Based on the method employed, patients were divided into two groups: the suture passer combined with a two-hole laparoscopy group (SLG) and the open surgical group (SG). Comprehensive patient information, including general data, preoperative and postoperative indicators, peritoneal function after surgery, and the incidence rate of complications, were collected and analyzed. RESULTS: The SLG showed a statistically significant decrease in operative time, intraoperative blood loss, and 6-month postoperative drift rate compared to the SG (p < 0.05). No statistically significant differences were observed between the two groups in terms of sex, age, primary disease, hospitalization time, hospitalization costs, preoperative and postoperative examination indicators, peritonitis, and omental wrapping. CONCLUSIONS: Suture passer combined with two-hole laparoscopic PDC placement, characterized by simplicity and facilitating secure catheter fixation, was deemed safe and effective for patients undergoing PD. It reduces the catheter migration rate and improved surgical comfort. Overall, this technique demonstrates favorable outcomes in clinical practice.


Subject(s)
Laparoscopy , Peritoneal Dialysis , Humans , Male , Female , Laparoscopy/methods , Retrospective Studies , Middle Aged , Peritoneal Dialysis/methods , Peritoneal Dialysis/instrumentation , Aged , Catheterization/methods , Adult , Catheters, Indwelling , Operative Time , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Kidney Failure, Chronic/therapy , Suture Techniques
6.
BMC Pregnancy Childbirth ; 24(1): 401, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822253

ABSTRACT

BACKGROUND: Previous studies had found that the mechanical methods were as effective as pharmacological methods in achieving vaginal delivery. However, whether balloon catheter induction is suitable for women with severe cervical immaturity and whether it will increase the related risks still need to be further explored. RESEARCH AIM: To evaluate the efficacy and safety of Foley catheter balloon for labor induction at term in primiparas with different cervical scores. METHODS: A total of 688 primiparas who received cervical ripening with a Foley catheter balloon were recruited in this study. They were divided into 2 groups: Group 1 (Bishop score ≤ 3) and Group 2 (3 < Bishop score < 7). Detailed medical data before and after using of balloon were faithfully recorded. RESULTS: The cervical Bishop scores of the two groups after catheter placement were all significantly higher than those before (Group 1: 5.49 ± 1.31 VS 2.83 ± 0.39, P<0.05; Group 2: 6.09 ± 1.00 VS 4.45 ± 0.59, P<0.05). The success rate of labor induction in group 2 was higher than that in group 1 (P<0.05). The incidence of intrauterine infection in Group 1 was higher than that in Group 2 (18.3% VS 11.3%, P<0.05). CONCLUSION: The success rates of induction of labor by Foley catheter balloon were different in primiparas with different cervical conditions, the failure rate of induction of labor and the incidence of intrauterine infection were higher in primiparas with severe cervical immaturity.


Subject(s)
Cervical Ripening , Cervix Uteri , Labor, Induced , Humans , Labor, Induced/methods , Female , Pregnancy , Retrospective Studies , Adult , Parity , Catheterization/methods , Term Birth , Young Adult , Urinary Catheterization/methods , Urinary Catheterization/instrumentation , Catheters
7.
Indian J Ophthalmol ; 72(6): 849-855, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38804802

ABSTRACT

PURPOSE: To study the outcomes of balloon dacryoplasty (BD) or (BDCP) in children with persistent congenital nasolacrimal duct obstruction (pCNLDO) by using new and reused balloon catheters. METHODS: Our retrospective analysis focused on managing pCNLDO by using the BD or BDCP technique. The study included children aged >1 year to <12 years who underwent single or multiple probings before. Our specific lacrimal workup included a detailed history and examination, as published earlier. We used conventional, straight, 2 mm × 13 mm/3 mm × 15 mm lacrimal balloons (FCI, Ophthacath). We have described a technique to use the same catheter for three BD procedures (1 new + 2 reuse). The outcomes were categorized as complete success, partial success, and failure. The minimum follow-up of each child was 6 months. RESULTS: We analyzed 64 children (89 eyes) with a mean age of 58 months (15-132 months). All children (100%) had epiphora with discharge and positive FDDT. All children underwent BD under general anesthesia - new balloons in 59 eyes and reused balloons in 30 eyes. The balloons were plasma sterilized akin to vitrectomy cutters and tubings of phaco machines. We noted three leaks from reused balloons (2 from the balloon tip and 1 from the plastic hub). At a mean follow-up of 14.5 months, complete success was noted in 77 eyes (86.5%) (52 new and 25 reuse), while 8 eyes had partial success (8.9%) (4 new and 4 reuse). Failure of BD was noted in four eyes (4.5%) (3 new and 1 reuse). None had significant complications with new or reused balloons. CONCLUSION: BD or BDCP is a quick, safe, easy, and effective procedure that resolves pCNLDO symptoms satisfactorily. Carefully reusing a conventional balloon catheter is possible with comparable efficacy and no additional complications in pCNLDO.


Subject(s)
Dacryocystorhinostomy , Lacrimal Duct Obstruction , Nasolacrimal Duct , Humans , Lacrimal Duct Obstruction/congenital , Lacrimal Duct Obstruction/therapy , Lacrimal Duct Obstruction/diagnosis , Retrospective Studies , Dacryocystorhinostomy/methods , Nasolacrimal Duct/surgery , Male , Female , Infant , Child, Preschool , Child , Follow-Up Studies , Catheterization/methods , Catheterization/instrumentation , Treatment Outcome , Equipment Design
8.
Sci Rep ; 14(1): 8784, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38627500

ABSTRACT

Eustachian tube balloon dilatation (ETBD) has shown promising results in the treatment of ET dysfunction (ETD); however, recurrent symptoms after ETBD frequently occur in patients with refractory ETD. The excessive pressure of balloon catheter during ETBD may induce the tissue hyperplasia and fibrotic changes around the injured mucosa. Sirolimus (SRL), an antiproliferative agent, inhibits tissue proliferation. An SRL-coated balloon catheter was fabricated using an ultrasonic spray coating technique with a coating solution composed of SRL, purified shellac, and vitamin E. This study aimed to investigate effectiveness of ETBD with a SRL-coated balloon catheter to prevent tissue proliferation in the rat ET after ETBD. In 21 Sprague-Dawley rats, the left ET was randomly divided into the control (drug-free ETBD; n = 9) and the SRL (n = 9) groups. All rats were sacrificed for histological examination immediately after and at 1 and 4 weeks after ETBD. Three rats were used to represent the normal ET. The SRL-coated ETBD significantly suppressed tissue proliferation caused by mechanical injuries compared with the control group. ETBD with SRL-coated balloon catheter was effective and safe to maintain ET luminal patency without tissue proliferation at the site of mechanical injuries for 4 weeks in a rat ET model.


Subject(s)
Ear Diseases , Eustachian Tube , Humans , Rats , Animals , Dilatation/methods , Rats, Sprague-Dawley , Catheterization/methods , Ear Diseases/therapy , Ear Diseases/diagnosis , Treatment Outcome
9.
Innovations (Phila) ; 19(2): 192-195, 2024.
Article in English | MEDLINE | ID: mdl-38606852

ABSTRACT

OBJECTIVE: Femoral artery cannulation is the most commonly used approach for cardiopulmonary bypass (CPB) in robotic cardiac procedures. However, without adding a distal perfusion cannula, leg ischemia can occur in up to 11.5% of patients. There is a well-described 2 to 4 mm size arterial branch that originates from the medial side of the external iliac artery or inferior epigastric artery, immediately above the inguinal ligament, and connects to the obturator artery. Therefore, it was historically named the corona mortis, which means "crown of death" in Latin. When peripheral cannulation is performed above this branch in the external iliac artery, we consider it a corona "vitae" because of its role as a limb-saving collateral. We report herein our standard technique of peripheral cannulation without the need of a distal perfusion cannula and preventing limb ischemia. METHODS: We included all patients who underwent robotic cardiac surgery with peripheral cannulation over a 16-month period at our institution. We cannulated just above the level of the inguinal ligament through a 2 to 3 cm transverse skin incision. The incidence of limb ischemia and vascular complications was recorded and analyzed. RESULTS: During the study period, 133 patients underwent robotic cardiac procedures with peripheral "external iliac" CPB. The size of the cannula was 21F or larger in 73% and 23F in 54% of the patients. No leg ischemia or femoral artery complications requiring additional intervention occurred. CONCLUSIONS: External iliac cannulation can be successfully performed in robot-assisted cardiac surgery using relatively large cannulas without the need of a distal limb perfusion catheter, with good results. In our view, given the importance of the corona mortis ("crown of death" in Latin) in perfusing the limb during CPB, we propose a new name for this artery in robotic cardiac surgery, namely, the corona vitae ("crown of life" in Latin).


Subject(s)
Iliac Artery , Robotic Surgical Procedures , Humans , Iliac Artery/surgery , Robotic Surgical Procedures/methods , Male , Female , Aged , Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Middle Aged , Ischemia/prevention & control , Catheterization, Peripheral/methods , Femoral Artery/surgery , Catheterization/methods
10.
Medicina (Kaunas) ; 60(4)2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38674325

ABSTRACT

Background and Objectives: Thoracic epidural catheterization (TEC) can be both uncomfortable and fearful for patients when performed awake with the thought that the procedure may be painful. The aim of this study was to assess the effect of low-dose intravenous ketamine administration on pain and anxiety during the TEC procedure. Materials and Methods: Sixty patients were randomly divided into two groups to receive intravenous (IV) placebo (Group P) and IV low-dose (0.15 mg/kg) ketamine (LDK) (Group K) 3 min before the procedure in a double-blind manner. A visual analog scale (VAS) was used to measure anxiety (VAS-A) and pain (VAS-P) scores. Vital parameters were monitored before premedication (T1), 20 min after premedication (T2), during skin anesthesia (T3), during TEC (T4), and 5 min after TEC (T5). VAS-A values were recorded at T1, T3, T4, and T5 periods, and VAS-P levels were noted at T3, T4, and T5 periods. Results: During TEC (T4), both VAS-P and VAS-A were significantly lower in Group K (p < 0.001). The mean VAS-A value was 10.6 mm lower, and the mean VAS-P value was 9 mm lower in Group K than in Group P at the T4 time point. Additionally, the mean VAS-P value was 7.7 mm lower in Group K compared to Group P at the T3 time point (p < 0.001). Both groups showed a statistically significant difference in VAS-A measurements when compared at their respective time points (p < 0.001). However, only Group P demonstrated a statistically significant difference in VAS-P measurements (p < 0.001). VAS-P values remained stable in Group K. The number of patients who did not recall the procedure was significantly higher in Group K (p < 0.001). Furthermore, the number of patients who would consent to the same procedure in the future was significantly higher in Group K (p = 0.007). Conclusions: A preprocedural LDK (0.15 mg/kg) can effectively prevent anxiety and pain experienced by patients during the TEC procedure. Administration of LDK may provide a more comfortable procedure process without causing ketamine-induced side effects (hemodynamic, respiratory, and psychological).


Subject(s)
Anxiety , Ketamine , Pain Measurement , Humans , Ketamine/administration & dosage , Ketamine/therapeutic use , Male , Female , Double-Blind Method , Anxiety/prevention & control , Anxiety/drug therapy , Adult , Middle Aged , Pain Measurement/methods , Analgesics/therapeutic use , Analgesics/administration & dosage , Catheterization/methods , Catheterization/adverse effects , Pain/drug therapy , Pain/prevention & control , Pain/psychology , Anesthesia, Epidural/methods
11.
Perfusion ; 39(1_suppl): 23S-38S, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38651584

ABSTRACT

Limb ischaemia is a clinically relevant complication of venoarterial extracorporeal membrane oxygenation (VA ECMO) with femoral artery cannulation. No selective distal perfusion or other advanced techniques were used in the past to maintain adequate distal limb perfusion. A more recent trend is the shift from the reactive or emergency management to the pro-active or prophylactic placement of a distal perfusion cannula to avoid or reduce limb ischaemia-related complications. Multiple alternative cannulation techniques to the distal perfusion cannula have been developed to maintain distal limb perfusion, including end-to-side grafting, external or endovascular femoro-femoral bypass, retrograde limb perfusion (e.g., via the posterior tibial, dorsalis pedis or anterior tibial artery), and, more recently, use of a bidirectional cannula. Venous congestion has also been recognized as a potential contributing factor to limb ischaemia development and specific techniques have been described with facilitated venous drainage or bilateral cannulation being the most recent, to reduce or avoid venous stasis as a contributor to impaired limb perfusion. Advances in monitoring techniques, such as near-infrared spectroscopy and duplex ultrasound analysis, have been applied to improve decision-making regarding both the monitoring and management of limb ischaemia. This narrative review describes the evolution of techniques used for distal limb perfusion during peripheral VA ECMO.


Subject(s)
Extracorporeal Membrane Oxygenation , Femoral Artery , Humans , Extracorporeal Membrane Oxygenation/methods , Perfusion/methods , Catheterization/methods , Ischemia/prevention & control , Ischemia/etiology , Adult , Catheterization, Peripheral/methods , Catheterization, Peripheral/adverse effects , Extremities/blood supply
13.
Sci Rep ; 14(1): 7341, 2024 03 28.
Article in English | MEDLINE | ID: mdl-38538734

ABSTRACT

Endoscopic Retrograde Cholangiopancreatography (ERCP) is the primary therapeutic procedure for pancreaticobiliary disorders, and studies highlighted the impact of papilla anatomy on its efficacy and safety. Our objective was to quantify the influence of papilla morphology on ERCP outcomes. We systematically searched three medical databases in September 2022, focusing on studies detailing the cannulation process or the rate of adverse events in the context of papilla morphology. The Haraldsson classification served as the primary system for papilla morphology, and a pooled event rate with a 95% confidence interval was calculated as the effect size measure. Out of 17 eligible studies, 14 were included in the quantitative synthesis. In studies using the Haraldsson classification, the rate of difficult cannulation was the lowest in type I papilla (26%), while the highest one was observed in the case of type IV papilla (41%). For post-ERCP pancreatitis, the event rate was the highest in type II papilla (11%) and the lowest in type I and III papilla (6-6%). No significant difference was observed in the cannulation failure and post-ERCP bleeding event rates between the papilla types. In conclusion, certain papilla morphologies are associated with a higher rate of difficult cannulation and post-ERCP pancreatitis.


Subject(s)
Ampulla of Vater , Pancreatitis , Humans , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/methods , Catheterization/methods , Ampulla of Vater/surgery , Sphincterotomy, Endoscopic/adverse effects , Pancreatitis/etiology
14.
J Vis Exp ; (204)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38465943

ABSTRACT

This study aimed to investigate the effects of long-term awake extracorporeal membrane oxygenation (ECMO) on the coagulation system in a sheep model. A total of ten healthy sheep were included in the study, with 5 sheep in each group. In the veno-arterial ECMO (V-A ECMO) group, cannulation was performed in the right carotid artery and the right external jugular vein. In the veno-venous ECMO (V-V ECMO) group, a dual-lumen catheter was utilized to insert into the right external jugular vein. After initiating ECMO, the sheep were recovered from anesthesia and remained awake for 7 days. The target activated clotting time (ACT) goal was set at 220-250 s. In both groups, the actual ACT fluctuated around 250 s with the dose of heparin gradually increasing, reaching almost 60 IU/kg/min at the end of the experiments. Moreover, the activated partial thromboplastin time (APTT) and thrombin time (TT) values were significantly higher in the V-A ECMO group compared to the V-V ECMO group, despite receiving the same doses of heparin. Although laboratory test results fluctuated within a normal and reasonable range, infarct foci in the kidneys were observed in both groups at the end of the study.


Subject(s)
Extracorporeal Membrane Oxygenation , Sheep , Animals , Extracorporeal Membrane Oxygenation/methods , Blood Coagulation , Heparin , Blood Coagulation Tests , Catheterization/methods
15.
Sci Rep ; 14(1): 5171, 2024 03 02.
Article in English | MEDLINE | ID: mdl-38431711

ABSTRACT

Ethical animal use follows the 3R's: Replacement, Reduction and Refinement. Here, we present the use of simultaneous jugular vein and cisterna magna catheterization via a port system in rats for repeated fluid sampling for 14 consecutive days without loss of catheter patency. This technique allows repeated intra-animal sampling without anesthesia and, if used with pooling samples from a cohort of animals, replaces the need for terminal collections for sufficient sample volumes.


Subject(s)
Anesthesia , Cisterna Magna , Humans , Rats , Animals , Catheterization/methods , Specimen Handling/methods , Catheters , Cerebrospinal Fluid
16.
Obstet Gynecol ; 143(5): 670-676, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38422505

ABSTRACT

OBJECTIVE: To investigate the effects of applying tension to a transcervical Foley balloon on delivery time in term nulliparous patients undergoing labor induction. METHODS: This cluster randomized clinical trial included 279 term nulliparous women presenting for labor induction with a plan for cervical ripening through transcervical Foley balloon placement. Participants were assigned to either the tension group (n=138) or the no-tension group (n=141) on the basis of randomized, weekly clusters (26 total clusters). The primary outcome measured was the time from initial Foley balloon insertion to delivery. Secondary outcomes included cesarean delivery rates, peripartum infection, and neonatal intensive care unit (NICU) admission. Our prior data suggested that delivery time in the tension group would be about 1,053 minutes. We estimated a sample size of 260 (130 per group, 26 clusters) on the basis of a 25% difference, power of 80%, and two-sided α of 0.05. RESULTS: A total of 279 term nulliparous patients were included in the analysis. The median time from Foley placement to delivery was 1,596 minutes (range 430-3,438 minutes) for the tension group and 1,621 minutes (range 488-3,323 minutes) for the no-tension group ( P =.8); similar results were noted for time to vaginal delivery. No significant differences were observed in the secondary outcomes, including the rates of cesarean delivery (34.1% vs 29.8%, P =.7), peripartum infection, and NICU admission, between the two groups. CONCLUSION: Applying tension to a transcervical Foley balloon in term nulliparous women undergoing labor induction did not significantly reduce delivery time or improve secondary outcomes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov , NCT05404776.


Subject(s)
Labor, Induced , Oxytocics , Pregnancy , Infant, Newborn , Humans , Female , Labor, Induced/methods , Delivery, Obstetric/methods , Cesarean Section , Catheterization/methods , Parity , Cervical Ripening
17.
Oper Neurosurg (Hagerstown) ; 26(3): 279-285, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38358285

ABSTRACT

BACKGROUND AND OBJECTIVES: Percutaneous trigeminal rhizotomies are common treatment modalities for medically refractory trigeminal neuralgia (TN). Failure of these procedures is frequently due to surgical inability to cannulate the foramen ovale (FO) and is thought to be due to variations in anatomy. The purpose of this study is to characterize the relationships between anatomic features surrounding FO and investigate the association between anatomic morphology and successful cannulation of FO in patients undergoing percutaneous trigeminal rhizotomy. METHODS: A retrospective analysis was conducted of all patients undergoing percutaneous trigeminal rhizotomy for TN at our academic center between January 1, 2010, and July 31, 2022. Preoperative 1-mm thin-cut computed tomography head imaging was accessed to perform measurements surrounding the FO, including inlet width, outlet width, interforaminal distance (a representation of the lateral extent of FO along the middle fossa), and sella-sphenoid angle (a representation of the coronal slope of FO). Mann-Whitney U tests assessed the difference in measurements for patients who succeeded and failed cannulation. RESULTS: Among 37 patients who met inclusion criteria, 34 (91.9%) successfully underwent cannulation. Successful cannulation was associated with larger inlet widths (median = 5.87 vs 3.67 mm, U = 6.0, P = .006), larger outlet widths (median = 7.13 vs 5.10 mm, U = 14.0, P = .040), and smaller sella-sphenoid angles (median = 52.00° vs 111.00°, U = 0.0, P < .001). Interforaminal distances were not associated with the ability to cannulate FO surgically. CONCLUSION: We have identified morphological characteristics associated with successful cannulation in percutaneous rhizotomies for TN. Preoperative imaging may optimize surgical technique and predict cannulation failure.


Subject(s)
Foramen Ovale , Trigeminal Neuralgia , Humans , Rhizotomy/methods , Foramen Ovale/diagnostic imaging , Foramen Ovale/surgery , Retrospective Studies , Neurosurgical Procedures/methods , Trigeminal Neuralgia/diagnostic imaging , Trigeminal Neuralgia/surgery , Catheterization/methods
18.
S Afr Fam Pract (2004) ; 66(1): e1-e6, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38299529

ABSTRACT

This is part of a series of articles on vascular access in emergencies. The other two articles were on intra osseous lines and central venous lines. These are critical lifesaving emergency skills for the primary care professional. In this article, we will provide an overview of umbilical vein catheterisation highlighting its importance, the indications, contraindications, techniques, complications and nursing considerations. By familiarising healthcare providers with this procedure, we hope to enhance their knowledge and skills, ultimately leading to improved outcomes in the neonatal population.


Subject(s)
Catheterization , Physicians, Family , Humans , Infant, Newborn , Catheterization/methods , Infusions, Intraosseous/methods , Primary Health Care , Umbilical Veins
20.
Am J Obstet Gynecol ; 230(5): 567.e1-567.e11, 2024 May.
Article in English | MEDLINE | ID: mdl-38367749

ABSTRACT

BACKGROUND: The optimal timing of amniotomy during labor induction is a topic of ongoing debate due to the potential risks associated with both amniotomy and prolonged labor. As such, individuals in the field of obstetrics and gynecology must carefully evaluate the associated benefits and drawbacks of this procedure. While amniotomy can expedite the labor process, it may also lead to complications such as umbilical cord prolapse, fetal distress, and infection. Therefore, a careful and thorough examination of the risks and benefits of amniotomy during labor induction is essential in making an informed decision regarding the optimal timing of this procedure. OBJECTIVE: This study aimed to determine if an amniotomy within 2 hours after Foley balloon removal reduced the duration of active labor and time taken to achieve vaginal delivery when compared with an amniotomy ≥4 hours after balloon removal among term pregnant women who underwent labor induction. STUDY DESIGN: This was an open-label, randomized controlled trial that was conducted at a single academic center from October 2020 to March 2023. Term participants who were eligible for preinduction cervical ripening with a Foley balloon were randomized into 2 groups, namely the early amniotomy (rupture of membranes within 2 hours after Foley balloon removal) and delayed amniotomy (rupture of membranes performed more than 4 hours after Foley balloon removal) groups. Randomization was stratified by parity. The primary outcome was time from Foley balloon insertion to active phase of labor. Secondary outcomes, including time to delivery, cesarean delivery rates, and maternal and neonatal complications, were analyzed using intention-to-treat and per-protocol analyses. RESULTS: Of the 150 participants who consented and were enrolled, 149 were included in the analysis. In the intention-to-treat population, an early amniotomy did not significantly shorten the time between Foley balloon insertion and active labor when compared with a delayed amniotomy (885 vs 975 minutes; P=.08). An early amniotomy was associated with a significantly shorter time from Foley balloon placement to active labor in nulliparous individuals (1211; 584-2340 vs 1585; 683-2760; P=.02). When evaluating the secondary outcomes, an early amniotomy was associated with a significantly shorter time to active labor onset (312.5 vs 442.5 minutes; P=.02) and delivery (484 vs 587 minutes; P=.03) from Foley balloon removal with a higher rate of delivery within 36 hours (96% vs 85%; P=.03). Individuals in the early amniotomy group reached active labor 1.5 times faster after Foley balloon insertion than those in the delayed group (hazard ratio, 1.5; 95% confidence interval, 1.1-2.2; P=.02). Those with an early amniotomy also reached vaginal delivery 1.5 times faster after Foley balloon removal than those in the delayed group (hazard ratio, 1.5; 95% confidence interval, 1-2.2; P=.03). A delayed amniotomy was associated with a higher rate of postpartum hemorrhage (0% vs 9.5%; P=.01). No significant differences were observed in the cesarean delivery rates, length of hospital stay, maternal infection, or neonatal outcomes. CONCLUSION: Although an early amniotomy does not shorten the time from Foley balloon insertion to active labor, it shortens time from Foley balloon removal to active labor and delivery without increasing complications. The increased postpartum hemorrhage rate in the delayed amniotomy group suggests increased risks with delayed amniotomy.


Subject(s)
Amniotomy , Cervical Ripening , Labor, Induced , Humans , Female , Labor, Induced/methods , Pregnancy , Adult , Amniotomy/methods , Time Factors , Catheterization/methods , Delivery, Obstetric/methods
SELECTION OF CITATIONS
SEARCH DETAIL