Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36.501
Filter
1.
Appl Microbiol Biotechnol ; 108(1): 355, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38822832

ABSTRACT

Getah virus (GETV) is a re-emerging mosquito-borne alphavirus that is highly pathogenic, mainly to pigs and horses. There are no vaccines or treatments available for GETV in swine in China. Therefore, the development of a simple, rapid, specific, and sensitive serological assay for GETV antibodies is essential for the prevention and control of GETV. Current antibody monitoring methods are time-consuming, expensive, and dependent on specialized instrumentation, and these features are not conducive to rapid detection in clinical samples. To address these problem, we developed immunochromatographic test strips (ICTS) using eukaryotically expressed soluble recombinant p62-E1 protein of GETV as a labelled antigen, which has good detection sensitivity and no cross-reactivity with other common porcine virus-positive sera. The ICTS is highly compatible with IFA and ELISA and can be stored for 1 month at 37 °C and for at least 3 months at room temperature. Hence, p62-E1-based ICTS is a rapid, accurate, and convenient method for rapid on-site detection of GETV antibodies. KEY POINTS: • We established a rapid antibody detection method that can monitor GETV infection • We developed colloidal gold test strips with high sensitivity and specificity • The development of colloidal gold test strips will aid in the field serologic detection of GETV.


Subject(s)
Alphavirus , Antibodies, Viral , Gold Colloid , Sensitivity and Specificity , Animals , Gold Colloid/chemistry , Antibodies, Viral/blood , Antibodies, Viral/immunology , Alphavirus/immunology , Swine , Chromatography, Affinity/methods , Alphavirus Infections/diagnosis , Alphavirus Infections/immunology , Swine Diseases/diagnosis , Swine Diseases/virology , Reagent Strips , China , Enzyme-Linked Immunosorbent Assay/methods
2.
Se Pu ; 42(5): 410-419, 2024 Apr 08.
Article in Chinese | MEDLINE | ID: mdl-38736384

ABSTRACT

Protein A affinity chromatographic materials are widely used in clinical medicine and biomedicine because of their specific interactions with immunoglobulin G (IgG). Both the characteristics of the matrix, such as its structure and morphology, and the surface modification method contribute to the affinity properties of the packing materials. The specific, orderly, and oriented immobilization of protein A can reduce its steric hindrance with the matrix and preserve its bioactive sites. In this study, four types of affinity chromatographic materials were obtained using agarose and polyglycidyl methacrylate (PGMA) spheres as substrates, and multifunctional epoxy and maleimide groups were used to fix protein A. The effects of the ethylenediamine concentration, reaction pH, buffer concentration, and other conditions on the coupling efficiency of protein A and adsorption performance of IgG were evaluated. Multifunctional epoxy materials were prepared by converting part of the epoxy groups of the agarose and PGMA matrices into amino groups using 0.2 and 1.6 mol/L ethylenediamine, respectively. Protein A was coupled to the multifunctional epoxy materials using 5 mmol/L borate buffer (pH 8) as the reaction solution. When protein A was immobilized on the substrates by maleimide groups, the agarose and PGMA substrates were activated with 25% (v/v) ethylenediamine for 16 h to convert all epoxy groups into amino groups. The maleimide materials were then converted into amino-modified materials by adding 3 mg/mL 3-maleimidobenzoyl-N-hydroxysuccinimide ester (MBS) dissolved in dimethyl sulfoxide (DMSO) and then suspended in 5 mmol/L borate buffer (pH 8). The maleimide groups reacted specifically with the C-terminal of the sulfhydryl group of recombinant protein A to achieve highly selective fixation on both the agarose and PGMA substrates. The adsorption performance of the affinity materials for IgG was improved by optimizing the bonding conditions of protein A, such as the matrix type, matrix particle size, and protein A content, and the adsorption properties of each affinity material for IgG were determined. The column pressure of the protein A affinity materials prepared using agarose or PGMA as the matrix via the maleimide method was subsequently evaluated at different flow rates. The affinity materials prepared with PGMA as the matrix exhibited superior mechanical strength compared with the materials prepared with agarose. Moreover, an excellent linear relationship between the flow rate and column pressure of 80 mL/min was observed for this affinity material. Subsequently, the effect of the particle size of the PGMA matrix on the binding capacity of IgG was investigated. Under the same protein A content, the dynamic binding capacity of the affinity materials on the PGMA matrix was higher when the particle size was 44-88 µm than when other particle sizes were used. The properties of the affinity materials prepared using the multifunctional epoxy and maleimide-modified materials were compared by synthesizing affinity materials with different protein A coupling amounts of 1, 2, 4, 6, 8, and 10 mg/mL. The dynamic and static binding capacities of each material for bovine IgG were then determined. The prepared affinity material was packed into a chromatographic column to purify IgG from bovine colostrum. Although all materials showed specific adsorption selectivity for IgG, the affinity material prepared by immobilizing protein A on the PGMA matrix with maleimide showed significantly better performance and achieved a higher dynamic binding capacity at a lower protein grafting amount. When the protein grafting amount was 15.71 mg/mL, the dynamic binding capacity of bovine IgG was 32.23 mg/mL, and the dynamic binding capacity of human IgG reached 54.41 mg/mL. After 160 cycles of alkali treatment, the dynamic binding capacity of the material reached 94.6% of the initial value, indicating its good stability. The developed method is appropriate for the production of protein A affinity chromatographic materials and shows great potential in the fields of protein immobilization and immunoadsorption material synthesis.


Subject(s)
Chromatography, Affinity , Staphylococcal Protein A , Chromatography, Affinity/methods , Staphylococcal Protein A/chemistry , Adsorption , Immunoglobulin G/chemistry , Polymethacrylic Acids/chemistry , Sepharose/chemistry
3.
Biosens Bioelectron ; 258: 116357, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38729049

ABSTRACT

The label probe plays a crucial role in enhancing the sensitivity of lateral flow immunoassays. However, conventional fluorescent microspheres (FMs) have limitations due to their short fluorescence lifetime, susceptibility to background fluorescence interference, and inability to facilitate multi-component detection. In this study, carboxylate-modified Eu(III)-chelate-doped polystyrene nanobeads were employed as label probes to construct a multiple time-resolved fluorescent microsphere-based immunochromatographic test strip (TRFM-ICTS). This novel TRFM-ICTS facilitated rapid on-site quantitative detection of three mycotoxins in grains: Aflatoxin B1 (AFB1), Zearalenone (ZEN), and Deoxynivalenol (DON). The limit of detection (LOD) for AFB1, ZEN, and DON were found to be 0.03 ng/g, 0.11 ng/g, and 0.81 ng/g, respectively. Furthermore, the TRFM-ICTS demonstrated a wide detection range for AFB1 (0.05-8.1 ng/g), ZEN (0.125-25 ng/g), and DON (1.0-234 ng/g), while maintaining excellent selectivity. Notably, the test strip exhibited remarkable stability, retaining its detection capability even after storage at 4 °C for over one year. Importantly, the detection of these mycotoxins relied solely on simple manual operations, and with a portable reader, on-site detection could be accomplished within 20 min. This TRFM-ICTS presents a promising solution for sensitive on-site mycotoxin detection, suitable for practical application in various settings due to its sensitivity, accuracy, simplicity, and portability.


Subject(s)
Biosensing Techniques , Edible Grain , Food Contamination , Limit of Detection , Microspheres , Mycotoxins , Zearalenone , Mycotoxins/analysis , Edible Grain/chemistry , Edible Grain/microbiology , Biosensing Techniques/methods , Food Contamination/analysis , Zearalenone/analysis , Chromatography, Affinity/methods , Chromatography, Affinity/instrumentation , Aflatoxin B1/analysis , Aflatoxin B1/isolation & purification , Trichothecenes/analysis , Reagent Strips/analysis , Immunoassay/methods , Immunoassay/instrumentation , Fluorescent Dyes/chemistry
4.
Front Biosci (Landmark Ed) ; 29(5): 191, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38812328

ABSTRACT

BACKGROUND: Human immunodeficiency virus (HIV) infection is associated with pronounced oxidative stress, leading to the development of various virus-associated pathologies. A wealth of evidence suggests that, along with canonical enzymes of reactive oxygen species regulation, human blood contains antibodies with peroxidase, superoxide dismutase, and catalase activities. Here we show that the catalase activity of IgGs and their κκ-IgG, λλ-IgG, and κλ-IgG subfractions of HIV-infected individuals is significantly different compared to the healthy donors. METHODS: Protein G-Sepharose sorbent was used to resolve IgG from blood of healthy donors and HIV-infected patients by affinity chromatography. Subfractions of κκ-IgG, λλ-IgG, and κλ-IgG were separated from IgGs samples of each group by affinity chromatography on sorbents containing immobilized antibodies to κ or λ light human chains. The IgG catalase activity level was measured spectrophotometrically by evaluating the decrease in optical density (A240) due to hydrogen peroxide decomposition. RESULTS: The relative catalase activity of antibodies from HIV-infected patients (kcat = (1.41 ± 0.92) × 103 min-1, 95% CI: [1.01-1.81]) was statistically significant, 1.6 times higher (p = 0.014) compared to apparently healthy donors ((0.86 ± 0.49) × 103, 95% CI: [0.69-1.03]). The activity level of κκ-IgG HIV-infected patients ((0.44 ± 0.04) × 103 min-1) was 1.4 times higher than that of λλ-IgGs ((0.31 ± 0.025) × 103 min-1); the opposite was observed for κκ-IgGs from apparently healthy donors, which activity ((0.17 ± 0.015) × 103 min-1) was 3.1 times lower compared to λλ-IgGs ((0.53 ± 0.045) × 103 min-1). CONCLUSIONS: Thus, the data obtained may indicate that IgG with increased catalase activity may prevent harmful processes arising from oxidative stress in HIV-infected patients, acting as an additional natural molecular mechanism of regulation of hydrogen peroxide level.


Subject(s)
Catalase , HIV Infections , Immunoglobulin G , Immunoglobulin kappa-Chains , Humans , Catalase/blood , Catalase/immunology , Catalase/metabolism , Immunoglobulin G/blood , Immunoglobulin G/immunology , HIV Infections/immunology , HIV Infections/blood , Immunoglobulin kappa-Chains/blood , Immunoglobulin kappa-Chains/immunology , Immunoglobulin lambda-Chains/blood , Immunoglobulin lambda-Chains/immunology , Adult , Case-Control Studies , Male , Female , Chromatography, Affinity/methods , Oxidative Stress , Middle Aged
5.
Mikrochim Acta ; 191(6): 325, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38739279

ABSTRACT

Glial fibrillary acidic protein (GFAP) in serum has been shown as a biomarker of traumatic brain injury (TBI) which is a significant global public health concern. Accurate and rapid detection of serum GFAP is critical for TBI diagnosis. In this study, a time-resolved fluorescence immunochromatographic test strip (TRFIS) was proposed for the quantitative detection of serum GFAP. This TRFIS possessed excellent linearity ranging from 0.05 to 2.5 ng/mL for the detection of serum GFAP and displayed good linearity (Y = 598723X + 797198, R2 = 0.99), with the lowest detection limit of 16 pg/mL. This TRFIS allowed for quantitative detection of serum GFAP within 15 min and showed high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 4.0%. Additionally, this TRFIS was applied to detect GFAP in the serum samples from healthy donors and patients with cerebral hemorrhage, and the results of TRFIS could efficiently discern the patients with cerebral hemorrhage from the healthy donors. Our developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range and is suitable for rapid and quantitative determination of serum GFAP on-site.


Subject(s)
Chromatography, Affinity , Glial Fibrillary Acidic Protein , Limit of Detection , Glial Fibrillary Acidic Protein/blood , Humans , Chromatography, Affinity/methods , Reagent Strips , Cerebral Hemorrhage/blood , Cerebral Hemorrhage/diagnosis , Biomarkers/blood
6.
Anal Chim Acta ; 1306: 342513, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38692783

ABSTRACT

Over the past decades, the proteomics field has undergone rapid growth. Progress in mass spectrometry and bioinformatics, together with separation methods, has brought many innovative approaches to the study of the molecular biology of the cell. The potential of affinity chromatography was recognized immediately after its first application in proteomics, and since that time, it has become one of the cornerstones of many proteomic protocols. Indeed, this chromatographic technique exploiting the specific binding between two molecules has been employed for numerous purposes, from selective removal of interfering (over)abundant proteins or enrichment of scarce biomarkers in complex biological samples to mapping the post-translational modifications and protein interactions with other proteins, nucleic acids or biologically active small molecules. This review presents a comprehensive survey of this versatile analytical tool in current proteomics. To navigate the reader, the haphazard space of affinity separations is classified according to the experiment's aims and the separated molecule's nature. Different types of available ligands and experimental strategies are discussed in further detail for each of the mentioned procedures.


Subject(s)
Chromatography, Affinity , Proteomics , Chromatography, Affinity/methods , Proteomics/methods , Humans , Proteins/isolation & purification , Proteins/analysis , Proteins/chemistry
7.
Protein Expr Purif ; 220: 106503, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38759705

ABSTRACT

Protein A affinity chromatography has been widely used for initial product capture in recombinant antibody/Fc-fusion purification. However, in general Protein A lacks the capability of separating aggregates (unless the aggregates are too large to enter the pores of resin beads or have their Protein A binding sites buried, in which case the aggregates do not bind). In the current work, we demonstrated that CaptureSelect FcXP affinity medium exhibited strong aggregate separation capability and effectively removed aggregates under pH or conductivity gradient elution in two bispecific antibody (bsAb) cases. For these two cases, aggregate contents were reduced from >16% and >22% (in the feed) to <1% and <5% (in the eluate) for the first and second bsAbs, respectively. While more case studies are required to further demonstrate FcXP's superiority in aggregate removal, findings from the current study suggest that FcXP can potentially be a better alternative than Protein A for product capture in cases where aggregate content is high.


Subject(s)
Antibodies, Bispecific , Chromatography, Affinity , Staphylococcal Protein A , Chromatography, Affinity/methods , Antibodies, Bispecific/chemistry , Antibodies, Bispecific/isolation & purification , Staphylococcal Protein A/chemistry , Recombinant Fusion Proteins/chemistry , Recombinant Fusion Proteins/isolation & purification , Recombinant Fusion Proteins/genetics , Protein Aggregates , Humans , Immunoglobulin Fc Fragments/chemistry , Immunoglobulin Fc Fragments/isolation & purification
8.
Anal Chim Acta ; 1310: 342717, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38811143

ABSTRACT

Parathion is one of organophosphorus pesticide, which has been prohibited in agricultural products due to its high toxicity to human beings. However, there are still abuse cases for profit in agricultural production. Hence, we established nanobodies-based colloidal gold immunochromatographic assay (GICA) in which nanobodies (Nbs) as an excellent recognition element, greatly improving the stability and sensitivity of ICA. Under the optimal conditions, the developed Nbs-based GICA showed a cut-off value of 50 ng/mL for visual judgment and a half-inhibitory concentration (IC50) of 2.39 ng/mL for quantitative detection. The limit of detection (LOD) was as low as 0.15 ng/mL which was significantly 50-fold higher sensitivity than the commercial mAb-ICA. Additionally, this method exhibited good recoveries for the detection of cabbage, cucumber, and orange samples and excellent correlation with the UPLC-MS/MS method. The results showed that this method developed in this work based on nanobody can be used in practical detection of parathion in foods and nanobody is novel prospective antibody resource for immunoassays of chemical contaminants.


Subject(s)
Chromatography, Affinity , Gold Colloid , Parathion , Single-Domain Antibodies , Single-Domain Antibodies/immunology , Single-Domain Antibodies/chemistry , Gold Colloid/chemistry , Parathion/analysis , Chromatography, Affinity/methods , Immunoassay/methods , Limit of Detection , Food Contamination/analysis
9.
Mikrochim Acta ; 191(6): 311, 2024 05 08.
Article in English | MEDLINE | ID: mdl-38717575

ABSTRACT

Urine retinol-binding protein 4 (RBP4) has recently been reported as a novel earlier biomarker of chronic kidney disease (CKD) which is a global public health problem with high morbidity and mortality. Accurate and rapid detection of urine RBP4 is essential for early monitor of impaired kidney function and prevention of CKD progression. In the present study, we developed a time-resolved fluorescence immunochromatographic test strip (TRFIS) for the quantitative and rapid detection of urine RBP4. This TRFIS possessed excellent linearity ranging from 0.024 to 12.50 ng/mL for the detection of urine RBP4, and displayed a good linearity (Y = 239,581 × X + 617,238, R2 = 0.9902), with the lowest visual detection limit of 0.049 ng/mL. This TRFIS allows for quantitative detection of urine RBP4 within 15 min and shows high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 8%, respectively. Additionally, this TRFIS was applied to detect RBP4 in the urine samples from healthy donors and patients with CKD, and the results of TRFIS could efficiently discern the patients with CKD from the healthy donors. The developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range, and is suitable for rapid and quantitative determination of urine RBP4.


Subject(s)
Chromatography, Affinity , Renal Insufficiency, Chronic , Retinol-Binding Proteins, Plasma , Humans , Retinol-Binding Proteins, Plasma/urine , Chromatography, Affinity/methods , Renal Insufficiency, Chronic/urine , Renal Insufficiency, Chronic/diagnosis , Limit of Detection , Reagent Strips , Biomarkers/urine , Immunoassay/methods
10.
J Vis Exp ; (206)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38738876

ABSTRACT

Functional characterization of proteins requires them to be expressed and purified in substantial amounts with high purity to perform biochemical assays. The Fast Protein Liquid Chromatography (FPLC) system allows high-resolution separation of complex protein mixtures. By adjusting various parameters in FPLC, such as selecting the appropriate purification matrix, regulating the protein sample's temperature, and managing the sample's flow rate onto the matrix and the elution rate, it is possible to ensure the protein's stability and functionality. In this protocol, we will demonstrate the versatility of the FPLC system to purify 6X-His-tagged flap endonuclease 1 (FEN1) protein, produced in bacterial cultures. To improve protein purification efficiency, we will focus on multiple considerations, including proper column packing and preparation, sample injection using a sample loop, flow rate of sample application to the column, and sample elution parameters. Finally, the chromatogram will be analyzed to identify fractions containing high yields of protein and considerations for proper recombinant protein long-term storage. Optimizing protein purification methods is crucial for improving the precision and reliability of protein analysis.


Subject(s)
Chromatography, Affinity , Chromatography, Affinity/methods , Flap Endonucleases/chemistry , Flap Endonucleases/isolation & purification , Flap Endonucleases/metabolism , Chromatography, Liquid/methods , Histidine/chemistry , Escherichia coli/genetics , Escherichia coli/chemistry , Escherichia coli/metabolism , Oligopeptides/chemistry , Oligopeptides/isolation & purification , Recombinant Fusion Proteins/chemistry , Recombinant Fusion Proteins/isolation & purification , Recombinant Fusion Proteins/genetics , Recombinant Fusion Proteins/metabolism
11.
Xi Bao Yu Fen Zi Mian Yi Xue Za Zhi ; 40(5): 428-434, 2024 May.
Article in Chinese | MEDLINE | ID: mdl-38790099

ABSTRACT

Objective To establish a colloidal gold immunochromatography and develop the corresponding test strip for detecting organophosphorus compounds including omethoate, phoxim, dipterex, and parathion in fruits, vegetables and drinking water. Methods Artificial antigen molecules of organophosphorus compounds were synthesized using N-hydroxysuccinimide esters. Acetylcholinesterase antigen was prepared and purified, and the serum containing the corresponding antibody was prepared, purified, and labeled. The working parameters of the test strip were optimized, and the performance evaluation of it was conducted. Results The titer of the antisera ranged from 1:32 to 1:64, with a protein content of approximately 2 mg/mL. The purified polyclonal antibodies displayed target bands at relative molecular masses (Mr) of 25 000 and 55 000, indicating satisfactory purity. The reaction time of the test strips was between 5 to 10 minutes, with a detection limit for samples at 200 ng/mL. Both specificity and accuracy were satisfactory, and the test strip remained valid for 6 months. Conclusion A simple and rapid colloidal gold immunochromatography is established successfully for detecting several organophosphorus compounds and may be useful for on-site preliminary screening of samples in large quantities.


Subject(s)
Chromatography, Affinity , Gold Colloid , Organophosphorus Compounds , Pesticides , Gold Colloid/chemistry , Organophosphorus Compounds/analysis , Chromatography, Affinity/methods , Pesticides/analysis , Animals , Vegetables/chemistry , Fruit/chemistry , Acetylcholinesterase
12.
Methods Mol Biol ; 2786: 339-364, 2024.
Article in English | MEDLINE | ID: mdl-38814403

ABSTRACT

Quality by digital design (QbDD) utilizes data-driven, mechanistic, or hybrid models to define and optimize a manufacturing design space. It improves upon the QbD approach used extensively in the pharmaceutical industry. The computational models developed in this approach identify and quantify the relationship between the product's critical quality attributes (CQAs) and the critical process parameters (CPPs) of unit operations within the manufacturing process. This chapter discusses the QbDD approach in developing and optimizing unit operations such as in vitro transcription, tangential flow filtration, affinity chromatography, and lipid nanoparticle (LNP) formulation in mRNA vaccine manufacturing. QbDD can be an efficient framework for developing a production process for a disease-agnostic product that requires extensive experimental and model-based process-product interaction characterization during the early process development phase.


Subject(s)
Quality Control , Humans , Nanoparticles/chemistry , mRNA Vaccines , Lipids/chemistry , Chromatography, Affinity/methods , Liposomes
13.
Methods Mol Biol ; 2799: 13-27, 2024.
Article in English | MEDLINE | ID: mdl-38727900

ABSTRACT

N-methyl-D-aspartate (NMDA) receptors are critical for brain function and serve as drug targets for the treatment of neurological and psychiatric disorders. They typically form the tetrameric assembly of GluN1-GluN2 (2A to 2D) subtypes, with their diverse three-dimensional conformations linked with the physiologically relevant function in vivo. Purified proteins of tetrameric assembled NMDA receptors have broad applications in the structural elucidation, hybridoma technology for antibody production, and high-throughput drug screening. However, obtaining sufficient quantity and monodisperse NMDA receptor protein is still technically challenging. Here, we summarize a paradigm for the expression and purification of diverse NMDA receptor subtypes, with detailed descriptions on screening constructs by fluorescence size-exclusion chromatography (FSEC), generation of recombinant baculovirus, expression in the eukaryotic expression system, protein purification by affinity chromatography and size-exclusion chromatography (SEC), biochemical and functional validation assays.


Subject(s)
Baculoviridae , Chromatography, Affinity , Chromatography, Gel , Receptors, N-Methyl-D-Aspartate , Receptors, N-Methyl-D-Aspartate/metabolism , Receptors, N-Methyl-D-Aspartate/genetics , Receptors, N-Methyl-D-Aspartate/isolation & purification , Receptors, N-Methyl-D-Aspartate/chemistry , Animals , Baculoviridae/genetics , Chromatography, Affinity/methods , Humans , Recombinant Proteins/isolation & purification , Recombinant Proteins/genetics , Recombinant Proteins/metabolism , Gene Expression , Sf9 Cells
14.
J Chromatogr A ; 1726: 464968, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38723492

ABSTRACT

The steric mass-action (SMA) model has been widely reported to describe the adsorption of proteins in different types of chromatographic adsorbents. Here in the present work, a pore-blocking steric mass-action model (PB-SMA) was developed for the adsorption of large-size bioparticles, which usually exhibit the unique pore-blocking characteristic on the adsorbent and thus lead to a fraction of ligands in the deep channels physically inaccessible to bioparticles adsorption, instead of being shielded due to steric hindrance by adsorbed bioparticles. This unique phenomenon was taken into account by introducing an additional parameter, Lin, which is defined as the inaccessible ligand densities in the physically blocked pore area, into the PB-SMA model. This fraction of ligand densities (Lin) will be deducted from the total ligand (Lt) for model development, thus the steric factor (σ) in the proposed PB-SMA will reflect the steric shielding effect on binding sites by adsorbed bioparticles more accurately than the conventional SMA model, which assumes that all ligands on the adsorbent have the same accessibility to the bioparticles. Based on a series of model assumptions, a PB-SMA model was firstly developed for inactivated foot-and-mouth disease virus (iFMDV) adsorption on immobilized metal affinity chromatography (IMAC) adsorbents. Model parameters for static adsorption including equilibrium constant (K), characteristic number of binding sites (n), and steric factor (σ) were determined. Compared with those derived from the conventional SMA model, the σ values derived from the PB-SMA model were dozens of times smaller and much closer to the theoretical maximum number of ligands shielded by a single adsorbed iFMDV, indicating the modified model was more accurate for bioparticles adsorption. The applicability of the PB-SMA model was further validated by the adsorption of hepatitis B surface antigen virus-like particles (HBsAg VLPs) on an ion exchange adsorbent with reasonably improved accuracy. Thus, it is considered that the PB-SMA model would be more accurate in describing the adsorption of bioparticles on different types of chromatographic adsorbents.


Subject(s)
Chromatography, Affinity , Adsorption , Chromatography, Affinity/methods , Foot-and-Mouth Disease Virus/chemistry , Ligands , Porosity , Models, Chemical
15.
J Agric Food Chem ; 72(20): 11794-11803, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38739902

ABSTRACT

High-performance liquid chromatography with ultraviolet detection (HPLC-UV) is a common analysis technique due to its high versatility and simple operation. In the present study, HPLC-UV detection was integrated with immunoaffinity cleanup (IAC) of the sample extracts. The matrix effect was greatly reduced, and the limit of detection was as low as 1 ng/g of free abscisic acid (ABA) in fresh plant tissues. A monoclonal antibody 3F1 (mAb 3F1) was developed to specifically recognize free ABA but not ABA analogues. The mAb 3F1-immobilized immunoaffinity column exhibited a capacity of 850 ng/mL and an elution efficiency of 88.8-105% for standards. The extraction recoveries of the column for ABA ranged from 80.4 to 108.9%. ABA content was detected in various plant samples with IAC-HPLC-UV. The results were verified with ultraperformance liquid chromatography-electrospray tandem mass spectrometry. IAC-HPLC-UV can be a sensitive and cost-efficient method for plant hormone analysis.


Subject(s)
Abscisic Acid , Chromatography, Affinity , Plant Growth Regulators , Abscisic Acid/analysis , Chromatography, High Pressure Liquid/methods , Plant Growth Regulators/analysis , Chromatography, Affinity/methods , Chromatography, Affinity/instrumentation , Antibodies, Monoclonal/chemistry , Tandem Mass Spectrometry/methods
16.
Microb Pathog ; 191: 106669, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38697231

ABSTRACT

African swine fever (ASF) is a lethal disease caused by ASF virus (ASFV), severely impacting the global swine industry. Though nuclear acid-based detection methods are reliable, they are laboratory-dependent. In this study, we developed a device-independent, user friendly and cost-effective quantum dots based immunochromatographic strip (QDs-ICS) with high specificity and sensitivity for the rapid and on-site detection of ASFV antigen. For the preparation of the QDs-ICS, we generated a monoclonal antibody (mAb) mAb-8G8 and polyclonal antibody (pAb) against ASFV-p72 protein. The pAb was labelled with QDs to be used as the detection probe and the mAb-8G8 was coated on the nitrocellulose membrane as the test line. Our results proved that the strip displayed no cross-reactivity with other swine viruses and detection limit of the QDs-ICS was down to 1 ng/mL for the ASFV-p72 protein with great reproducibility. The strip also exhibited high stability with a storage period up to 12 months under room temperature. Twenty blind samples and one hundred clinical samples were examined by the QDs-ICS, conventional PCR and real-time PCR method, respectively. Results showed that the agreement rate between the QDs-ICS and PCR method was 100%, and the agreement rate between the strip and real-time PCR was 94%. The novel QDs-ICS developed here would be an effective tool for on-site detection of ASFV.


Subject(s)
African Swine Fever Virus , African Swine Fever , Antibodies, Monoclonal , Antibodies, Viral , Antigens, Viral , Chromatography, Affinity , Quantum Dots , Sensitivity and Specificity , African Swine Fever Virus/isolation & purification , African Swine Fever Virus/immunology , African Swine Fever Virus/genetics , Animals , African Swine Fever/diagnosis , African Swine Fever/virology , African Swine Fever/immunology , Swine , Antibodies, Monoclonal/immunology , Antibodies, Viral/immunology , Chromatography, Affinity/methods , Antigens, Viral/analysis , Antigens, Viral/immunology , Reproducibility of Results , Reagent Strips
17.
J Agric Food Chem ; 72(19): 11241-11250, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38709728

ABSTRACT

The fungicide phenamacril has been employed to manage Fusarium and mycotoxins in crops, leading to persistent residues in the environment and plants. Detecting phenamacril is pivotal for ensuring environmental and food safety. In this study, haptens and artificial antigens were synthesized to produce antiphenamacril monoclonal antibodies (mAbs). Additionally, gold nanoparticles coated with a polydopamine shell were synthesized and conjugated with mAbs, inducing fluorescence quenching in quantum dots. Moreover, a dual-readout immunochromatographic assay that combines the positive signal from fluorescence with the negative signal from colorimetry was developed to enable sensitive and precise detection of phenamacril within 10 min, achieving detection limits of 5 ng/mL. The method's reliability was affirmed by using spiked wheat flour samples, achieving a limit of quantitation of 0.05 mg/kg. This analytical platform demonstrates high sensitivity, outstanding accuracy, and robust tolerance to matrix effects, making it suitable for the rapid, onsite, quantitative screening of phenamacril residues.


Subject(s)
Colorimetry , Food Contamination , Fungicides, Industrial , Pesticide Residues , Fungicides, Industrial/analysis , Food Contamination/analysis , Colorimetry/methods , Pesticide Residues/analysis , Antibodies, Monoclonal/chemistry , Chromatography, Affinity/methods , Chromatography, Affinity/instrumentation , Fluorescence , Triticum/chemistry , Metal Nanoparticles/chemistry , Gold/chemistry , Limit of Detection , Flour/analysis
18.
Int J Biol Macromol ; 270(Pt 1): 132381, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38754664

ABSTRACT

Florfenicol (FF), with its broad-spectrum antibacterial activity, is frequently abused in the livestock and poultry industries and has aroused the growing public concern. Owing to structural similarities and varying maximum residue limits between florfenicol and other chloramphenicol (CAP)-type antibiotics, including thiamphenicol (TAP) and chloramphenicol (CAP), there is an urgent need for a rapid and effective immunoassay method to distinguish them, in order to minimize the risk of false positives. Fortunately, a highly specific monoclonal antibody (mAb), named as SF11, has been developed using hybridoma technology. Molecular simulations have revealed that the mAb SF11's specificity in recognizing florfenicol stems from the π-π stacking interaction between florfenicol and the mAb SF11 binding pocket. Using this highly specific mAb, a sensitive time-resolved fluorescence immunochromatographic assay (TRFICA) strip for rapid florfenicol detection has been developed. Under optimal conditions, this TRFICA demonstrated good analytical performance for the detection of florfenicol in milk and eggs samples, with the half-maximal inhibition concentration (IC50) values of 1.89 and 2.86 ng mL-1, the limit of detection (LOD) of 0.23 and 0.48 ng mL-1, the cut-off values of 62.50 and 31.25 ng mL-1, and the testing time of approximately thirteen minutes. Spiked recoveries in the milk and eggs samples ranged from 104.7 % to 112.3 % and 95.3 % to 116.4 %, respectively, with no obvious cross-reactions with the other analogues observed. The TRFICA results correlated well with those of high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) for real samples, indicating that the developed TRFICA method was sensitive, accurate and adapted for the rapid determination of florfenicol in milk and egg samples.


Subject(s)
Antibodies, Monoclonal , Eggs , Milk , Thiamphenicol , Thiamphenicol/analogs & derivatives , Thiamphenicol/analysis , Milk/chemistry , Animals , Eggs/analysis , Antibodies, Monoclonal/chemistry , Drug Residues/analysis , Immunoassay/methods , Chromatography, Affinity/methods , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/chemistry , Food Contamination/analysis
19.
J Chromatogr A ; 1721: 464851, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38574547

ABSTRACT

The increasing medical application of virus-like particles (VLPs), notably vaccines and viral vectors, has increased the demand for commercial VLP production. However, VLP manufacturing has not yet reached the efficiency level achieved for recombinant protein therapeutics, especially in downstream processing. This review provides a comprehensive analysis of the challenges associated with affinity chromatography for VLP purification with respect to the diversity and complexity of VLPs and the associated upstream and downstream processes. The use of engineered affinity ligands and matrices for affinity chromatography is first discussed. Although several representative affinity ligands are currently available for VLP purification, most of them have difficulty in balancing ligand universality, ligand selectivity and mild operation conditions. Then, phage display technology and computer-assisted design are discussed as efficient methods for the rapid discovery of high-affinity peptide ligands. Finally, the VLP purification by affinity chromatography is analyzed. The process is significantly influenced by virus size and variation, ligand type and chromatographic mode. To address the updated regulatory requirements and epidemic outbreaks, technical innovations in affinity chromatography and process intensification and standardization in VLP purification should be promoted to achieve rapid process development and highly efficient VLP manufacturing, and emphasis is given to the discovery of universal ligands, applications of gigaporous matrices and platform technology. It is expected that the information in this review can provide a better understanding of the affinity chromatography methods available for VLP purification and offer useful guidance for the development of affinity chromatography for VLP manufacturing in the decades to come.


Subject(s)
Vaccines, Virus-Like Particle , Ligands , Recombinant Proteins , Peptides , Chromatography, Affinity
20.
Molecules ; 29(7)2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38611935

ABSTRACT

Immobilized metal ion affinity chromatography (IMAC) adsorbents generally have excellent affinity for histidine-rich proteins. However, the leaching of metal ions from the adsorbent usually affects its adsorption performance, which greatly affects the reusable performance of the adsorbent, resulting in many limitations in practical applications. Herein, a novel IMAC adsorbent, i.e., Cu(II)-loaded polydopamine-coated urchin-like titanate microspheres (Cu-PDA-UTMS), was prepared via metal coordination to make Cu ions uniformly decorate polydopamine-coated titanate microspheres. The as-synthesized microspheres exhibit an urchin-like structure, providing more binding sites for hemoglobin. Cu-PDA-UTMS exhibit favorable selectivity for hemoglobin adsorption and have a desirable adsorption capacity towards hemoglobin up to 2704.6 mg g-1. Using 0.1% CTAB as eluent, the adsorbed hemoglobin was easily eluted with a recovery rate of 86.8%. In addition, Cu-PDA-UTMS shows good reusability up to six cycles. In the end, the adsorption properties by Cu-PDA-UTMS towards hemoglobin from human blood samples were analyzed by SDS-PAGE. The results showed that Cu-PDA-UTMS are a high-performance IMAC adsorbent for hemoglobin separation, which provides a new method for the effective separation and purification of hemoglobin from complex biological samples.


Subject(s)
Hemoglobins , Imidazoles , Indoles , Polymers , Humans , Microspheres , Chromatography, Affinity , Ions
SELECTION OF CITATIONS
SEARCH DETAIL