Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.183
Filter
1.
Nat Commun ; 15(1): 5635, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38965218

ABSTRACT

The wearable contact lens that continuously monitors intraocular pressure (IOP) facilitates prompt and early-state medical treatments of oculopathies such as glaucoma, postoperative myopia, etc. However, either taking drugs for pre-treatment or delaying the treatment process in the absence of a neural feedback component cannot realize accurate diagnosis or effective treatment. Herein, a neuroprosthetic contact lens enabled sensorimotor system is reported, which consists of a smart contact lens with Ti3C2Tx Wheatstone bridge structured IOP strain sensor, a Ti3C2Tx temperature sensor and an IOP point-of-care monitoring/display system. The point-of-care IOP monitoring and warning can be realized due to the high sensitivity of 12.52 mV mmHg-1 of the neuroprosthetic contact lens. In vivo experiments on rabbit eyes demonstrate the excellent wearability and biocompatibility of the neuroprosthetic contact lens. Further experiments on a living rate in vitro successfully mimic the biological sensorimotor loop. The leg twitching (larger or smaller angles) of the living rat was demonstrated under the command of motor cortex controlled by somatosensory cortex when the IOP is away from the normal range (higher or lower).


Subject(s)
Contact Lenses , Intraocular Pressure , Point-of-Care Systems , Animals , Intraocular Pressure/physiology , Rabbits , Rats , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Wearable Electronic Devices , Neural Prostheses , Humans , Feedback, Sensory/physiology
3.
Genes (Basel) ; 15(6)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38927751

ABSTRACT

The identification of new biomarkers of ocular diseases is nowadays of outmost importance both for early diagnosis and treatment. Epigenetics is a rapidly growing emerging area of research and its involvement in the pathophysiology of ocular disease and regulatory mechanisms is of undisputable importance for diagnostic purposes. Environmental changes may impact the ocular surface, and the knowledge of induced epigenetic changes might help to elucidate the mechanisms of ocular surface disorders. In this pilot study, we investigated the impact of extensive contact lens (CL) wearing on human corneal epithelium epigenetics. We performed ex vivo analysis of the expression of the miR-320 and miR-423-5p involved in the processes of cellular apoptosis and chronic inflammation. The human corneal epithelium was harvested from healthy patients before the photorefractive keratectomy (PRK). The patients were divided into two age- and sex-matched groups accordingly to CL wearing history with no CL wearers used as a control. The epithelium was stored frozen in dry ice at -80 °C and forwarded for miRNA extraction; afterwards, miRNA levels were detected using real-time PCR. Both miRNAs were highly expressed in CL wearers (p < 0.001), suggesting epigenetic modifications occurring in chronic ocular surface stress. These preliminary results show the relationships between selected miRNA expression and the chronic ocular surface stress associated with extensive CL use. MicroRNAs might be considered as biomarkers for the diagnosis of ocular surface conditions and the impact of environmental factors on ocular surface epigenetic. Furthermore, they might be considered as new therapeutic targets in ocular surface diseases.


Subject(s)
Biomarkers , Contact Lenses , Epithelium, Corneal , MicroRNAs , Humans , MicroRNAs/genetics , Epithelium, Corneal/metabolism , Epithelium, Corneal/pathology , Female , Male , Adult , Biomarkers/metabolism , Pilot Projects , Epigenesis, Genetic , Gene Expression Regulation
4.
Int Ophthalmol ; 44(1): 239, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38904856

ABSTRACT

BACKGROUND: This meta-analysis reviews the evidence for the risks and benefits associated with orthokeratology (OK) treatment compared with other methods of myopia control in children and adults. METHODS: A systematic search of Cochrane Central Register of Controlled Trials, Pubmed, Embase and Ovid was conducted from database inception to 22nd August 2021. Studies that reported on risks, visual and ocular biometric effects of OK in patients > 5 years of age with myopia (- 0.75 to - 6.00D) were included. Main outcomes are change in axial length and any adverse event. RESULTS: Fourty-five papers were included in this systematic review and meta-analysis. The quality of data was variable and of moderate certainty, and selection bias likely skewed the results towards a relative benefit for OK. The rate of axial elongation in children was lower for OK treatment compared to other treatment modalities at one year (MD - 0.16 mm, 95% CI - 0.25 to - 0.07). Rate of change in axial length in children rebounded after OK discontinuation compared to participants who continued treatment (MD 0.10 mm, 95% CI 0.06 to 0.14). Adults and children wearing OK were up to 3.79 times more likely to experience an adverse event when compared with conventional contact lenses (OR 3.79, 95% CI 1.24 to ll.), though this evidence base is underdeveloped and requires additional well-designed studies for substantial conclusions to be drawn. CONCLUSIONS: OK arrests myopia progression while in use, however, there remain unanswered questions about the optimal duration of treatment, discontinuation effects and long-term risk for adverse events.


Subject(s)
Myopia , Orthokeratologic Procedures , Refraction, Ocular , Humans , Orthokeratologic Procedures/methods , Orthokeratologic Procedures/adverse effects , Myopia/therapy , Myopia/physiopathology , Refraction, Ocular/physiology , Visual Acuity , Axial Length, Eye , Contact Lenses , Child , Risk Assessment/methods
5.
Medicine (Baltimore) ; 103(24): e38384, 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38875374

ABSTRACT

It aims to study the efficacy and safety of low-concentration Atropine combined with orthokeratology (OK) lens in delaying juvenile myopia. This is a prospective study, 172 adolescents aged 8 to 12 years who were admitted to the diopter department of Hengshui People Hospital from April 2021 to May 2022 were selected. According to the equivalent spherical diopter measured at the time of initial diagnosis, myopic patients were randomly divided into low myopia group (group A) and moderate myopia group (group B). At the same time, according to the different treatment methods, the patients were divided into the group wearing frame glasses alone (group c), the group wearing frame glasses with low-concentration Atropine (group d), the group wearing corneal shaping glasses alone at night (group e), and the group wearing corneal shaping glasses at night with low-concentration Atropine (group f). The control effect of myopia development and axial elongation in group f was better than that in groups d and e (P < .05). The effect of controlling myopia development and axial elongation in group f is with P > .05. The probability of postoperative adverse reactions in group f was lower and lower than that in the other groups. Low-concentration atropine combined with OK lens could effectively delay the development of juvenile myopia, and had a high safety. Low-concentration of Atropine would not have a significant impact on the basic tear secretion and tear film stability. Nightwear of OK lens also had no significant impact, but it would significantly reduce the tear film rupture time in the first 3 months, and at the same time, the tear film rupture time would be the same after 6 months as before treatment.


Subject(s)
Atropine , Myopia , Orthokeratologic Procedures , Humans , Atropine/administration & dosage , Atropine/therapeutic use , Child , Myopia/therapy , Male , Female , Orthokeratologic Procedures/methods , Prospective Studies , Mydriatics/administration & dosage , Mydriatics/therapeutic use , Treatment Outcome , Ophthalmic Solutions/administration & dosage , Contact Lenses
6.
Medicina (Kaunas) ; 60(6)2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38929602

ABSTRACT

Background and Objectives: Dry Eye Disease (DED) is a chronic condition characterised by tear film instability and ocular surface disruption, significantly impacting patients' quality of life. This study aimed to provide top-level clinical evidence for the long-term efficacy of dehydrated amniotic membrane (dAM, Omnigen®) delivered via a specialised bandage contact lens (sBCL, OmniLenz) for managing moderate-to-severe DED. Materials and Methods: This randomised controlled trial (NCT04553432) involved 93 participants with moderate-to-severe DED, randomised to receive a 1-week bilateral treatment of either dAM (17 mm diameter with 6 mm central 'window') applied under a sBCL or sBCL alone. Participants were assessed at baseline and followed up at 1, 3, and 6 months post-treatment. Outcomes included changes in symptomatology, tear film and ocular surface measurements, and in vivo confocal microscopy imaging of corneal nerve parameters and corneal dendritic cell (CDC) counts. Results: The dAM-sBCL group demonstrated a 65% reduction in OSDI scores at 6 months (p < 0.001), with 88% of participants showing improvement at 1 month. Corneal staining was significantly reduced in both groups. dAM-sBCL provided significant improvements in corneal nerve parameters at 1 month, with sustained positive trends at 3 months. Additionally, dAM-sBCL significantly reduced mature CDC counts, suggesting an anti-inflammatory effect. Conclusions: Treatment with dAM-sBCL for just 1 week significantly and rapidly improved dry eye symptoms as well as ocular surface signs for at least 3 months. It also enhanced corneal nerve health while reducing activated/mature corneal inflammatory cell numbers, presenting a safe and promising new treatment for moderate-to-severe DED.


Subject(s)
Amnion , Dry Eye Syndromes , Humans , Dry Eye Syndromes/therapy , Male , Female , Amnion/transplantation , Middle Aged , Adult , Contact Lenses , Treatment Outcome , Aged , Quality of Life , Bandages , Cornea
7.
Anal Chem ; 96(26): 10477-10487, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38888091

ABSTRACT

Wearable devices are lightweight and portable devices worn directly on the body or integrated into the user's clothing or accessories. They are usually connected to the Internet and combined with various software applications to monitor the user's physical conditions. The latest research shows that wearable head devices, particularly those incorporating microfluidic technology, enable the monitoring of bodily fluids and physiological states. Here, we summarize the main forms, functions, and applications of head wearable devices through innovative researches in recent years. The main functions of wearable head devices are sensor monitoring, diagnosis, and even therapeutic interventions. Through this application, real-time monitoring of human physiological conditions and noninvasive treatment can be realized. Furthermore, microfluidics can realize real-time monitoring of body fluids and skin interstitial fluid, which is highly significant in medical diagnosis and has broad medical application prospects. However, despite the progress made, significant challenges persist in the integration of microfluidics into wearable devices at the current technological level. Herein, we focus on summarizing the cutting-edge applications of microfluidic contact lenses and offer insights into the burgeoning intersection between microfluidics and head-worn wearables, providing a glimpse into their future prospects.


Subject(s)
Wearable Electronic Devices , Humans , Head , Monitoring, Physiologic/instrumentation , Contact Lenses
8.
Eye Contact Lens ; 50(7): 297-304, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38695745

ABSTRACT

OBJECTIVES: To explore the potential of artificial intelligence (AI) to assist prescription determination for orthokeratology (OK) lenses. METHODS: Artificial intelligence algorithm development followed by a real-world trial. A total of 11,502 OK lenses fitting records collected from seven clinical environments covering major brands. Records were randomly divided in a three-way data split. Cross-validation was used to identify the most accurate algorithm, followed by an evaluation using an independent test data set. An online AI-assisted system was implemented and assessed in a real-world trial involving four junior and three senior clinicians. RESULTS: The primary outcome measure was the algorithm's accuracy (ACC). The ACC of the best performance of algorithms to predict the targeted reduction amplitude, lens diameter, and alignment curve of the prescription was 0.80, 0.82, and 0.83, respectively. With the assistance of the AI system, the number of trials required to determine the final prescription significantly decreased for six of the seven participating clinicians (all P <0.01). This reduction was more significant among junior clinicians compared with consultants (0.76±0.60 vs. 0.32±0.60, P <0.001). Junior clinicians achieved clinical outcomes comparable to their seniors, as 93.96% (140/149) and 94.44% (119/126), respectively, of the eyes fitted achieved unaided visual acuity no worse than 0.8 ( P =0.864). CONCLUSIONS: AI can improve prescription efficiency and reduce discrepancies in clinical outcomes among clinicians with differing levels of experience. Embedment of AI in practice should ultimately help lessen the medical burden and improve service quality for myopia boom emerging worldwide.


Subject(s)
Algorithms , Artificial Intelligence , Myopia , Orthokeratologic Procedures , Prescriptions , Humans , Orthokeratologic Procedures/methods , Myopia/therapy , Myopia/physiopathology , Female , Male , Contact Lenses , Child , Prosthesis Fitting/methods , Adolescent , Visual Acuity/physiology
9.
Ophthalmic Physiol Opt ; 44(5): 867-875, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38699941

ABSTRACT

PURPOSE: The fit and optical performance of a scleral lens is affected by the alignment of the landing zone with the underlying ocular surface. The aim of this research was to quantify the effect of landing zone toricity upon scleral lens fitting characteristics (rotation and decentration) and optics (lens flexure) during short-term wear. METHODS: Scleral lenses with nominal landing zone toricities of 0, 100, 150 and 200 µm were worn in a randomised order by 10 young healthy participants (mean [SD] 24 [7] years) for 30 min, with other lens parameters held constant. Scleral toricity was quantified using a corneo-scleral profilometer, and lens flexure, rotation, and decentration were quantified using over-topography during lens wear. Repeated measures analyses were conducted as a function of landing zone toricity and residual scleral toricity (the difference between scleral and lens toricity) for eyes with 'low' magnitude scleral toricity (mean: 96 µm) and 'high' magnitude scleral toricity (mean: 319 µm). RESULTS: Toric landing zones significantly reduced lens flexure (by 0.37 [0.21] D, p < 0.05) and lens rotation (by 20 [24]°, p < 0.05) compared with a spherical landing zone. Horizontal and vertical lens decentration did not vary significantly with landing zone toricity. These trends for flexure, rotation, and decentration were also observed for eyes with 'low' and 'high' magnitude scleral toricity as a function of residual scleral toricity. CONCLUSION: Landing zones with 100-200 µm toricity significantly reduced lens flexure (by ~62%) and rotation (by ~77%) but not horizontal or vertical lens decentration, compared with a spherical landing zone, when controlling for other confounding variables. The incorporation of a toric landing zone, even for eyes with lower magnitude scleral toricity (~100 µm), may be beneficial, particularly for front surface optical designs.


Subject(s)
Contact Lenses , Refraction, Ocular , Sclera , Humans , Male , Young Adult , Adult , Female , Refraction, Ocular/physiology , Prosthesis Fitting , Optics and Photonics , Corneal Topography , Visual Acuity/physiology
10.
ACS Biomater Sci Eng ; 10(6): 4035-4045, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38778794

ABSTRACT

Frequent blood glucose monitoring is a crucial routine for diabetic patients. Traditional invasive methods can cause discomfort and pain and even pose a risk of infection. As a result, researchers have been exploring noninvasive techniques. However, a limited number of products have been developed for the market due to their high cost. In this study, we developed a low-cost, highly accessible, and noninvasive contact lens-based glucose monitoring system. We functionalized the surface of the contact lens with boronic acid, which has a strong but reversible binding affinity to glucose. To achieve facile conjugation of boronic acid, we utilized a functional coating layer called poly(tannic acid). The functionalized contact lens binds to glucose in body fluids (e.g., tear) and releases it when soaked in an enzymatic cocktail, allowing for the glucose level to be quantified through a colorimetric assay. Importantly, the transparency and oxygen permeability of the contact lens, which are crucial for practical use, were maintained after functionalization, and the lenses showed high biocompatibility. Based on the analysis of colorimetric data generated by the smartphone application and ultraviolet-visible (UV-vis) spectra, we believe that this contact lens has a high potential to be used as a smart diagnostic tool for monitoring and managing blood glucose levels.


Subject(s)
Colorimetry , Contact Lenses , Glucose , Colorimetry/methods , Humans , Glucose/metabolism , Glucose/analysis , Blood Glucose/analysis , Blood Glucose/metabolism , Boronic Acids/chemistry , Body Fluids/chemistry , Body Fluids/metabolism , Smartphone , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Tears/chemistry , Tears/metabolism
11.
Invest Ophthalmol Vis Sci ; 65(5): 4, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38691089

ABSTRACT

Purpose: To investigate the adhesion of Acanthamoeba to scleral contact lens (ScCL) surface according to lens shape. Methods: Two strains of A. polyphaga (CDC:V062 and ATCC 30461) and one clinical Acanthamoeba isolate, were inoculated onto five contact lens (CL): one first-generation silicone hydrogel (SHCL; lotrafilcon B; adhesion control) containing plasma surface treatment; two ScCL (fluorosilicone acrylate) one containing surface treatment composed of plasma and the other containing plasma with Hydra-PEG, and two CL designed with a flat shape having the same material and surface treatments of the ScCL. Trophozoites that adhered to the lens's surfaces were counted by inverted optical light microscopy. Possible alterations of the lens surface that could predispose amoeba adhesion and Acanthamoeba attached to these lens surfaces were evaluated by scanning electron microscopy (SEM). Results: All strains revealed greater adhesion to the ScCL when compared with the flat lenses (P < 0.001). The clinical isolate and the ATCC 30461 had a higher adhesion (P < 0.001) when compared with the CDC:V062. A rough texture was observed on the surface of the lenses that have been examined by SEM. Also, SEM revealed that the isolates had a rounded appearance on the surface of the ScCL in contrast with an elongated appearance on the surface of the silicone hydrogel. Conclusions: The findings revealed that the curved shape of the ScCL favors amoeba adhesion.


Subject(s)
Acanthamoeba , Microscopy, Electron, Scanning , Acanthamoeba/physiology , Acanthamoeba/ultrastructure , Sclera , Humans , Contact Lenses, Hydrophilic/parasitology , Cell Adhesion/physiology , Contact Lenses/parasitology , Trophozoites/ultrastructure , Trophozoites/physiology , Hydrogels , Animals
12.
Transl Vis Sci Technol ; 13(5): 12, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38758570

ABSTRACT

Purpose: To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs). Methods: This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF). Results: Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils. Conclusions: The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size. Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.


Subject(s)
Myopia , Orthokeratologic Procedures , Refraction, Ocular , Visual Acuity , Humans , Female , Orthokeratologic Procedures/methods , Male , Visual Acuity/physiology , Prospective Studies , Adolescent , Myopia/therapy , Myopia/physiopathology , Child , Double-Blind Method , Refraction, Ocular/physiology , Contrast Sensitivity , Contact Lenses
13.
Sci Rep ; 14(1): 11727, 2024 05 22.
Article in English | MEDLINE | ID: mdl-38778161

ABSTRACT

The tear fluid is a readily accessible, potential source for biomarkers of disease and could be used to monitor the ocular response to contact lens (CL) wear or ophthalmic pathologies treated by therapeutic CLs. However, the tear fluid remains largely unexplored as a biomarker source for RNA-based molecular analyses. Using a rabbit model, this study sought to determine whether RNA could be collected from commercial CLs and whether the duration of CL wear would impact RNA recovery. The results were referenced to standardized strips of filtered paper (e.g., Shirmer Strips) placed in the inferior fornix. By performing total RNA isolation, precipitation, and amplification with commercial kits and RT-PCR methods, CLs were found to have no significant differences in RNA concentration and purity compared to Schirmer Strips. The study also identified genes that could be used to normalize RNA levels between tear samples. Of the potential control genes or housekeeping genes, GAPDH was the most stable. This study, which to our knowledge has never been done before, provides a methodology for the detection of RNA and gene expression changes from tear fluid that could be used to monitor or study eye diseases.


Subject(s)
Contact Lenses , RNA , Tears , Tears/metabolism , Animals , Rabbits , RNA/isolation & purification , RNA/genetics , RNA/analysis
14.
Int J Med Sci ; 21(7): 1329-1336, 2024.
Article in English | MEDLINE | ID: mdl-38818477

ABSTRACT

Purpose: The purpose of this study was to compare the differences in myopic control effects between orthokeratology (OK) contact lenses and defocus incorporated multiple segments (DIMS) spectacle lenses. Methods: A retrospective cohort study was conducted that included patients who had received OK lens, DIMS spectacle lens or single-vision spectacle treatments. A total of 54 eyes from 27 individuals, 38 eyes from 19 individuals and 42 eyes from 21 individuals were enrolled into the OK lens, DIMS and control groups, respectively. The primary outcomes were the changes in the spherical equivalent refraction (SER) and axial length (AXL) among the groups. A repeated-measure ANCOVA was adopted to calculate the SER progression and AXL elongation of the OK lens group compared with the DIMS group. Results: The difference in the SER progression was clinically non-significant in the OK lens group compared with the DIMS and control groups (P = 0.001). The total AXL elongation results were similar between the OK lens and DIMS groups, but these were lower than in the control group (P = 0.005). The repeated-measure ANCOVA revealed that the SER progression difference during the study interval was clinically non-significant in the OK lens group when compared with the DIMS group (P = 0.028). The AXL elongation results between the OK lens and DIMS populations did not illustrate a significant difference (P = 0.607). In a subgroup analysis of moderate astigmatism, better AXL control was observed in the DIMS subgroup compared with the OK lens subgroup (P = 0.016). Conclusions: The OK lens demonstrated a clinically non-significant effect on the SER and AXL controls compared with the DIMS spectacle lens.


Subject(s)
Eyeglasses , Myopia , Orthokeratologic Procedures , Refraction, Ocular , Humans , Myopia/therapy , Myopia/physiopathology , Male , Female , Orthokeratologic Procedures/methods , Retrospective Studies , Refraction, Ocular/physiology , Adult , Contact Lenses , Young Adult , Adolescent , Visual Acuity , Treatment Outcome
15.
Eye Contact Lens ; 50(7): 329-331, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38728248

ABSTRACT

ABSTRACT: Radial keratotomy (RK) was commonly performed in the 1980s and 1990s. We aimed to clarify the current status of post-RK refractive correction and treatment. We retrospectively reviewed the charts of 70 patients with a history of RK. Of the 70 patients, 44 were identified for clinical outcomes. Refractive or therapeutic intervention (rigid gas-permeable contact lens fit, spectacle prescription, corneal surgery, and use of pilocarpine hydrochloride for photophobia) was possible in 59% of patients with postoperative visual deterioration after RK; in the remaining 41%, therapeutic intervention was not possible. Rigid gas-permeable contact lens fit for corneal irregular astigmatism was the most common refractive intervention and was effective in 36% of cases in the university hospital.


Subject(s)
Keratotomy, Radial , Visual Acuity , Humans , Retrospective Studies , Male , Female , Middle Aged , Adult , Aged , Astigmatism/surgery , Astigmatism/physiopathology , Refraction, Ocular/physiology , Follow-Up Studies , Contact Lenses , Young Adult
16.
Harefuah ; 163(5): 278-285, 2024 May.
Article in Hebrew | MEDLINE | ID: mdl-38734939

ABSTRACT

INTRODUCTION: The importance of myopia management lies in the desire to minimize the potential ocular risks that increase with high myopia. AIMS: To assess the decrease in myopia progression using topical low dose atropine combined with peripheral blur contact lenses (CL). METHODS: This retrospective review study included 25 children between the ages of 8.5 years to 14 years. The children all had a minimal increase in myopia of 0.75D during the year prior to treatment. The children were divided into two groups. The control group included 14 children who wore single-vision spectacles )SV) averaging 3.20±0.9D ranging from 1.5-5.3D. The study group included 11 children who wore dual-focus CL, with an average prescription of 3.4±0.7D ranging from 2.5 to 4.3D, for one year. At that point, when an additional myopia increase was observed, the children were additionally treated with topical 0.01% atropine for two years (CL+A0.01). RESULTS: There was an increase in myopia in the SV group of 1.12±0.52D, 1.08±0.56D and 0.96±0.53D in the first, second, and third years, respectively. The myopia increase in the CL+A0.01 group was 0.57±0.48D, 0.14±0.34D, and 0.17±0.29D in the first, second, and third years, respectively. CONCLUSIONS: Low-dose atropine combined with peripheral blur contact lenses was effective in decreasing myopia progression in this study. Additional, larger-scale studies are required in the future. DISCUSSION: This study found a significant decrease in myopia progression in the second and third years of treatment. The CL group showed less effectivity than the CL+A0.01 group.


Subject(s)
Atropine , Contact Lenses , Disease Progression , Myopia , Humans , Atropine/administration & dosage , Child , Myopia/therapy , Myopia/physiopathology , Retrospective Studies , Adolescent , Male , Female , Treatment Outcome , Mydriatics/administration & dosage , Ophthalmic Solutions/administration & dosage , Eyeglasses
17.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Article in Russian | MEDLINE | ID: mdl-38742501

ABSTRACT

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Subject(s)
Contact Lenses , Keratoconus , Sclera , Visual Acuity , Humans , Keratoconus/surgery , Keratoconus/diagnosis , Keratoconus/physiopathology , Keratoconus/therapy , Female , Male , Adult , Sclera/surgery , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Treatment Outcome , Corneal Topography , Prostheses and Implants , Young Adult , Prosthesis Fitting/methods , Adolescent , Corneal Stroma/surgery
19.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(6): 237-247, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38588998

ABSTRACT

This 32-centre multicentre study addresses the lack of knowledge about the prevalence and significance of microbial keratitis (MK) associated with contact lens (CL) wear in Spain. A total of 304 cases recruited from 32 hospitals were studied and showed that infectious keratitis associated with contact lens wear mainly affects young women during the summer months. In this study, soft lenses with monthly replacement and single solution cleaning were most commonly used, purchased and fitted in opticians' shops. Common risk factors were identified among users, such as topping off solutions, prolonging the life of lenses, and frequently sleeping, swimming and showering with lenses. Overnight lens wear was significantly associated with a higher incidence of corneal opacities, and the presence of Pseudomonas aeruginosa in bacterial cultures was associated with more severe sequelae and a greater need for corneal transplantation. Although most cases were benign, the time taken to heal was long, which poses a problem for working patients. This study provides valuable epidemiological, microbiological and risk factor information and estimates the incidence of CL related MK in Spain to be approximately 1 case per 30,000 inhabitants per year.


Subject(s)
Contact Lenses , Keratitis , Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Contact Lenses/adverse effects , Contact Lenses/microbiology , Eye Infections, Bacterial/epidemiology , Eye Infections, Bacterial/etiology , Eye Infections, Bacterial/microbiology , Incidence , Keratitis/microbiology , Keratitis/epidemiology , Keratitis/etiology , Prevalence , Risk Factors , Spain/epidemiology
20.
Adv Mater ; 36(27): e2313848, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38583064

ABSTRACT

The increasing prevalence of dry eye syndrome in aging and digital societies compromises long-term contact lens (CL) wear and forces users to regular eye drop instillation to alleviate discomfort. Here a novel approach with the potential to improve and extend the lubrication properties of CLs is presented. This is achieved by embedding lubricant-secreting biofactories within the CL material. The self-replenishable reservoirs autonomously produce and release hyaluronic acid (HA), a natural lubrication and wetting agent, long term. The hydrogel matrix regulates the growth of the biofactories and the HA production, and allows the diffusion of nutrients and HA for at least 3 weeks. The continuous release of HA sustainably reduces the friction coefficient of the CL surface. A self-lubricating CL prototype is presented, where the functional biofactories are contained in a functional ring at the lens periphery, outside of the vision area. The device is cytocompatible and fulfils physicochemical requirements of commercial CLs. The fabrication process is compatible with current manufacturing processes of CLs for vision correction. It is envisioned that the durable-by-design approach in living CL could enable long-term wear comfort for CL users and minimize the need for lubricating eye drops.


Subject(s)
Hyaluronic Acid , Hydrogels , Lubrication , Hyaluronic Acid/chemistry , Hydrogels/chemistry , Lubricants/chemistry , Contact Lenses , Humans
SELECTION OF CITATIONS
SEARCH DETAIL