Results 1 - 20 de 63
Filter
1.
Am J Sports Med ; 52(11): 2815-2825, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39221758

ABSTRACT

BACKGROUND: Despite improved visualization, the use of arthroscopic surgery to perform the Latarjet procedure has not decreased the rates of complications and glenohumeral osteoarthritis (OA) in the long term. Many of the reported complications are related to the use of screws for bone block fixation with freehand drilling. PURPOSE: To evaluate the long-term (at a minimum 10-year follow-up) clinical and radiological outcomes of the arthroscopic Bristow-Latarjet procedure using a posterior guided drilling technique and suture button for coracoid bone graft fixation. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Consecutive patients who underwent the arthroscopic Bristow-Latarjet procedure with suture button fixation between 2011 and 2013 were reviewed by 2 independent evaluators. Complications and revision surgery were recorded, and we evaluated patient-reported outcomes including subjective scores, recurrence of shoulder instability (dislocation or subluxation), range of motion limitations, and return to sports. Patients had radiographs taken at least 10 years after surgery to assess glenohumeral OA according to the Samilson-Prieto classification system and computed tomography scans to assess bone block positioning and healing. RESULTS: A total of 65 consecutive patients (68 shoulders) with a mean follow-up of 135 months (range, 120-156 months) were included. The mean age at the time of surgery was 25 ± 8 years; 7 patients had previous failed Bankart repair. At follow-up, 94% (64/68) of the shoulders had no recurrence of instability. The 4 cases of instability recurrence were traumatic and occurred at 3 weeks (a fall), 4 months, 2 years, and 7 years after surgery. No hardware failures, coracoid fractures, or neurological complications were observed. Overall, 61 patients (94%) were still participating in sports, with 44 (68%) at the same or higher level. Range of motion showed nonsignificant restrictions in external rotation with the arm at the side (7° ± 9°) and with the arm at 90° of abduction (9° ± 10°) compared with the contralateral side. Additionally, 11 shoulders (16%) had some residual anterior apprehension on clinical examination. At last follow-up, 77% (47/61) of the shoulders had no OA development or progression. Previous failed Bankart repair was a risk factor for the development of OA. Patients with OA had significantly lower Subjective Shoulder Value scores (79% vs 91%, respectively; P = .01) and decreased external rotation with the arm at the side (40° vs 65°, respectively; P = .001) compared with patients with no or little OA. CONCLUSION: The arthroscopically guided Bristow-Latarjet procedure with suture button fixation is a safe and durable surgical treatment method for recurrent anterior shoulder instability, allowing a high rate of return to sports without significant motion restrictions and no or little OA in the long term.


Subject(s)
Arthroscopy , Joint Instability , Shoulder Joint , Humans , Male , Adult , Female , Arthroscopy/methods , Follow-Up Studies , Joint Instability/surgery , Young Adult , Shoulder Joint/surgery , Adolescent , Range of Motion, Articular , Bone Transplantation/methods , Middle Aged , Osteoarthritis/surgery , Shoulder Dislocation/surgery , Retrospective Studies , Recurrence , Return to Sport , Coracoid Process/surgery
2.
Am J Sports Med ; 52(12): 3094-3102, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39324536

ABSTRACT

BACKGROUND: Contact and collision athletes face a higher risk of recurrent anterior shoulder instability after surgical stabilization. The Latarjet procedure is often preferred given the high incidence of bony lesions. However, this stabilizing procedure, performed either open or arthroscopically, is met with concerns regarding complications and revision surgery rates. PURPOSE: To evaluate the return to sport (RTS) and assess complication and instability recurrence rates in contact/collision athletes undergoing the arthroscopic Latarjet procedure using a guided technique with suture buttons for coracoid fixations. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A retrospective analysis was conducted on contact/collision athletes who underwent the arthroscopic Latarjet procedure for recurrent anterior shoulder instability between January 2011 and March 2018. All patients were operated on arthroscopically using glenoid and coracoid guides and suture button fixation of the transferred coracoid. RTS was defined as the patient being able to participate in his or her activity without any restriction postoperatively. Two independent observers assessed patients using postoperative computed tomography (CT) scans to evaluate coracoid positioning and healing. A multivariate analysis was performed to identify predictive factors associated with persistent apprehension. A group comparison was performed to assess RTS failure risk factors. RESULTS: In 136 contact/collision athletes (mean age, 25 ± 7 years), 93% were satisfied, and 98% achieved shoulder stability at a mean follow-up of 60 months (range, 24-117 months). No suture button-related complications or neurovascular issues were reported. Overall, 82% (112/136) returned to contact/collision sports. The mean time to RTS was 5.3 ± 1.2 months (range, 3-7.3 months). In a CT study performed 2 weeks after surgery, 87% (118/136) of bone grafts were positioned below the equator and 93% (126/136) were flush to the glenoid surface. At the 6-month postoperative CT examination, complete bone block healing was achieved in 84% (114/136). On clinical examination at the latest follow-up, 36 patients (26%) reported some anterior apprehension on testing. On multivariate analysis, patients with severe humeral bone defects (medium to large Hill-Sachs lesions, Calandra grade 2 or 3) had a higher risk of postoperative persistent apprehension. On group comparison, a visual analog scale score >3 and persistent anterior apprehension were found to be associated with failure of RTS. CONCLUSION: The arthroscopic Latarjet procedure with suture button fixation allowed 82% of athletes with recurrent anterior shoulder instability to return to contact or collision sports. Patients with severe humeral bone defects have a higher risk of persistent anterior apprehension and decreased RTS. The arthroscopic-guided procedure with suture button fixation is safe; accurate, with a high rate of anatomic graft positioning and healing; and reliable, with a low recurrence rate.


Subject(s)
Arthroscopy , Joint Instability , Recurrence , Return to Sport , Humans , Retrospective Studies , Arthroscopy/methods , Female , Male , Young Adult , Joint Instability/surgery , Adult , Adolescent , Athletic Injuries/surgery , Shoulder Joint/surgery , Athletes , Shoulder Dislocation/surgery , Coracoid Process/surgery
3.
BMC Musculoskelet Disord ; 25(1): 645, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39148072

ABSTRACT

BACKGROUND: A coracoid process fracture combined with an acromioclavicular (AC) joint dislocation is an uncommon injury that typically causes significant pain and limits shoulder movement. Open reduction and internal fixation have been the traditional treatment approach. However, arthroscopic techniques are emerging as a promising alternative for managing these injuries. CASE REPRESENTATION: A 35-year-old woman presented with right shoulder pain following an accidental fall. Imaging studies revealed a coracoid process fracture along with an AC joint dislocation. The fracture was classified as an Eyres Type IIIA, which warranted surgical intervention. Our team performed arthroscopic coracoid fracture reduction and internal fixation surgery, as well as AC joint dislocation repair using Kirschner wires. Six months after surgery, the patient demonstrated a satisfactory functional outcome with complete bone healing. CONCLUSION: This case report highlights the potential of arthroscopic reduction and fixation as a novel treatment option for fractures of the coracoid base.


Subject(s)
Arthroscopy , Bone Screws , Coracoid Process , Fracture Fixation, Internal , Fractures, Bone , Humans , Female , Adult , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Arthroscopy/methods , Coracoid Process/surgery , Coracoid Process/injuries , Coracoid Process/diagnostic imaging , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Treatment Outcome , Acromioclavicular Joint/surgery , Acromioclavicular Joint/injuries , Acromioclavicular Joint/diagnostic imaging , Scapula/surgery , Scapula/injuries , Scapula/diagnostic imaging
4.
Arch Orthop Trauma Surg ; 144(8): 3491-3501, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39025979

ABSTRACT

INTRODUCTION: The purpose of this prospective study was to report the outcomes of two different methods in CC and AC reconstruction for the treatment of AC separation using a tendon graft and knot-hiding titanium clavicular implant. MATERIALS AND METHODS: Twenty-seven patients with Rockwood grade III and V acromioclavicular (AC) separations were randomized into two groups. The primary outcome was whether taking the tendon graft through the coracoid risked a fracture. The following were secondary outcomes: follow-up of clavicular wound healing and Nottingham Clavicle score, Constant score, and Simple Shoulder Test results obtained preoperatively and 24 months postoperatively. The anteroposterior radiographic change between the clavicular and coracoid cortexes and the clavicular tunnel diameter was measured postoperatively and 24 months postoperatively. General patient satisfaction with the outcome (poor, fair, good, or excellent) was assessed 2 years postoperatively. RESULTS: No coracoid fractures were detected. No issues in clavicular wound healing were detected. The mean Nottingham Clavicle score increased from a preoperative mean of 42.42 ± 13.42 to 95.31 ± 14.20 (P < 0.00). The Constant score increased from a preoperative mean of 50.81 ± 17.77 to 96.42 ± 11.51 (P < 0.001). The Simple Shoulder Test score increased from a preoperative mean of 7.50 ± 2.45 to 11.77 ± 1.18 (P < 0.001). The changes were significant. The coracoclavicular distance increased from 11.88 ± 4.00 to 14.19 ± 4.71 mm (P = 0.001), which was significant. The clavicular drill hole diameter increased from 5.5 to a mean of 8.00 ± 0.75 mm. General patient satisfaction was excellent. CONCLUSIONS: There were no significant differences between the two groups. There were no implant related complications in the clavicular wound healing. The results support the notion that good results are achieved by reconstructing both the CC and AC ligaments with a tendon graft. STUDY REGISTRATION: This clinical trial was registered on Clinicaltrials.gov.


Subject(s)
Acromioclavicular Joint , Clavicle , Coracoid Process , Patient Reported Outcome Measures , Tendons , Humans , Acromioclavicular Joint/surgery , Acromioclavicular Joint/injuries , Acromioclavicular Joint/diagnostic imaging , Male , Female , Adult , Prospective Studies , Tendons/transplantation , Tendons/surgery , Clavicle/injuries , Clavicle/surgery , Clavicle/diagnostic imaging , Middle Aged , Coracoid Process/surgery , Coracoid Process/transplantation , Radiography , Plastic Surgery Procedures/methods , Young Adult
5.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(6): 641-645, 2024 Jun 15.
Article in Chinese | MEDLINE | ID: mdl-38918181

ABSTRACT

Objective: To explore the research progress of the coracoid transfer surgery using suture button fixation, particularly focusing on the technique known as Chinese unique Inlay Bristow (Cuistow surgery). Methods: Extensive literature review was conducted to summarize and analyze the utilization of suture button fixation in the Cuistow surgery, comparing its biomechanical and clinical outcomes with those of traditional screw fixation. Results: Utilizing suture button fixation in coracoid transfer surgery helps circumvent certain metal-related complications associated with traditional screw fixation. While its biomechanical stability and effectiveness have been preliminarily confirmed, debates persist regarding its graft healing rate and postoperative recurrence rate compared to traditional screw fixation. The Cuistow surgery based on the Inlay structure is a solution to improve the healing rate of graft after suture button fixation. Conclusion: Suture button fixation, as a novel approach in coracoid transfer surgery, remains to have its advantages and disadvantages compared to traditional screw fixation not entirely elucidated, underscoring the need for further in-depth clinical and fundamental research. Cuistow surgery is the Chinese experience of coracoid transfer surgery, and its biomechanical stability and clinical advantages have been preliminarily confirmed.


Subject(s)
Suture Techniques , Humans , Biomechanical Phenomena , Coracoid Process/surgery , Bone Screws , Sutures , Bone Transplantation/methods
6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(6): 655-659, 2024 Jun 15.
Article in Chinese | MEDLINE | ID: mdl-38918183

ABSTRACT

Objective: To evaluate the early-term effectiveness of Latarjet procedure with double EndoButtons fixation for recurrent anterior shoulder dislocation by coracoid osteotomy with preserving coracoacromial ligament. Methods: Between January 2021 and June 2023, 19 patients with recurrent anterior shoulder dislocations were treated by arthroscopic Latarjet procedure with double EndoButtons fixation, all of which underwent coracoid osteotomy with preserving the coracoacromial ligament. There were 11 males and 8 females, with an average age of 23.3 years (range, 17-32 years). Shoulder dislocations ranged from 3 to 11 times, with an average of 6.4 times. The disease duration ranged from 3 to 35 months, with an average of 12.9 months. All apprehension tests were positive. Imaging examination showed that the defect width of the ipsilateral glenoid bone was 13%-26%, with an average of 19.8%. After operation, the shoulder range of motion was examined, including flexion lift, lateral external rotation, extension 90° external rotation, and internal rotation. Shoulder joint function was evaluated by Walch-Duplay score, American Association for Shoulder and Elbow Surgery (ASES) score, and Rowe score. Imaging examinations were taken to observe the position and shaping of coracoid. Results: All incisions healed by first intention and no nerve or vessel injury occurred. All patients were followed up 9-24 months (mean, 14.5 months). There was no recurrence of shoulder dislocation and the apprehension tests were negative during follow-up. There was no significant difference in the shoulder range of motion (flexion lift, lateral external rotation, extension 90° external rotation, and internal rotation) between preoperation and at last follow-up ( P>0.05). The Walch-Duplay score, ASES score, and Rowe score significantly improved when compared with those before operation ( P<0.05). Postoperative imaging showed that coracoid graft was at the same level with the glenoid in all cases; the center of coracoid graft was located between 3 to 5 o'clock. During follow-up, there was no glenohumeral joint degeneration, the acromiaohumeral distance was not reduced when compared with preoperation, and the coracoid bone gradually formed concentric circles with the humeral head. Conclusion: The Latarjet procedure with double EndoButtons fixation can effectively treat recurrent anterior shoulder dislocation by coracoid osteotomy with preserving coracoacromial ligament, and the early-term effectiveness is satisfactory.


Subject(s)
Coracoid Process , Ligaments, Articular , Osteotomy , Range of Motion, Articular , Shoulder Dislocation , Humans , Shoulder Dislocation/surgery , Male , Female , Adult , Osteotomy/methods , Adolescent , Young Adult , Coracoid Process/surgery , Ligaments, Articular/surgery , Recurrence , Arthroscopy/methods , Treatment Outcome
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(6): 672-678, 2024 Jun 15.
Article in Chinese | MEDLINE | ID: mdl-38918186

ABSTRACT

Objective: To investigate the early effectiveness of the limited unique coracoid osteotomy suture button fixation Latarjet (LU-tarjet)-congruent-arc (CA) technique (LU-tarjet-CA) in treating recurrent shoulder dislocations with huge glenoid defect. Methods: The clinical data of 12 patients with recurrent shoulder dislocation and huge glenoid defect who met the selection criteria and treated with arthroscopic LU-tarjet-CA between January 2021 and December 2023 were retrospectively analyzed. The cohort included 8 males and 4 females, aged 20-40 years with an average age of 30.4 years. The range of glenoid bone loss was 30%-40%, with an average of 35.5%. The time from symptom onset to hospital admission ranged from 1 to 36 months, with an average of 18.5 months. The University of California Los Angeles (UCLA) score, American Association for Shoulder and Elbow Surgery (ASES) score, Walch-Duplay score, and Rowe score were used to evaluate shoulder function preoperatively and at 3, 6, and 12 months postoperatively. CT three-dimensional (3D) reconstruction was used to assess coracoid healing and plasticity at 3, 6, and 12 months postoperatively. Subjective satisfaction of patient was recorded at last follow-up. Results: All incisions healed by first intention, with no incision infection or nerve injury. All 12 patients were followed up 12 months. One patient developed Propionibacterium acnes infection within the joint postoperatively and recovered after initial arthroscopic debridement and anti-inflammatory treatment. At 3 months after operation, CT 3D-reconstruction showed 1 case of complete coracoid absorption; neither of these two patients experienced redislocation. The remaining patients exhibited partial coracoid absorption but displayed local reshaping, filling the preoperative defect area, and bony fusion between the coracoid and the glenoid. At last follow-up, 9 patients (75%) were very satisfied with the outcome, and 3 patients (25%) were satisfied; the satisfied patients experienced postoperative shoulder stiffness caused by suboptimal functional exercise but did not have impaired daily life activities. The UCLA score, ASES score, Walch-Duplay score, and Rowe score at 3, 6, and 12 months postoperatively were significantly better than preoperative scores, and each score improved further over time postoperatively, with significant differences between different time points ( P<0.05). Conclusion: The arthroscopic LU-tarjet-CA technique for treating recurrent shoulder dislocations with huge glenoid defect can achieve the surgical objective of bony blockade and filling bone defects to prevent shoulder dislocation, thereby improving patients' quality of life and shoulder joint function and stability.


Subject(s)
Arthroscopy , Osteotomy , Recurrence , Shoulder Dislocation , Humans , Male , Female , Adult , Shoulder Dislocation/surgery , Arthroscopy/methods , Osteotomy/methods , Young Adult , Treatment Outcome , Range of Motion, Articular , Shoulder Joint/surgery , Coracoid Process/surgery , Suture Techniques
8.
J Shoulder Elbow Surg ; 33(10): 2236-2242, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38710366

ABSTRACT

BACKGROUND: Coracoid nonunion is a relevant complication following the Latarjet procedure and is influenced by multiple factors, including the method of graft fixation. The purpose of this study was to evaluate and characterize the biomechanical properties of various two-screw fixation constructs used for coracoid graft fixation in the Latarjet procedure. METHODS: Forty model scapulae (Sawbones Inc., Vashon, WA, USA) were used for this study. A 15% anterior inferior glenoid bone defect was created. The coracoid was osteotomized at the juncture of the vertical and horizontal aspects, transferred to the anterior-inferior edge of the glenoid, and fixed with either two 3.5 mm fully threaded cannulated cortical screws, two 3.5 mm fully threaded solid cortical screws, two 3.5 mm partially threaded cannulated screws, or two 4.5 mm partially threaded malleolar screws (MS). Biomechanical testing was performed with an Instron material testing machine (Instron Corp., Norwood, MA, USA) by applying loads to the lateral aspect of the transferred coracoid graft. The constructs were preconditioned with nondestructive cyclical loading (0N-20N) to determine construct stiffness. After 100 cycles of dynamic loading, the construct was loaded to failure to determine ultimate failure load, yield displacement, and mode of failure. RESULTS: All failures were associated with plastic deformation of the screws and coracoid graft fracture. There was a significantly lower initial stiffness for partially threaded cannulated screws compared to MS (186 ± 49.3 N/mm vs. 280 ± 65.5 N/mm, P = .01) but no significant differences among the other constructs. There was no difference in ultimate failure load (P = .18) or yield displacement (P = .05) among constructs. CONCLUSION: Two screw coracoid fixation of the coracoid in a simulated classic Latarjet procedure with 3.5 mm fully threaded cortical and cannulated screws is comparable to 4.5 mm MS in strength, stiffness, and displacement at failure. On the other hand, partially threaded 3.5 mm cannulated screws provide inferior fixation stiffness and could potentially affect clinical outcomes.


Subject(s)
Bone Screws , Coracoid Process , Humans , Biomechanical Phenomena , Coracoid Process/surgery , Scapula/surgery , Bone Transplantation/methods , Materials Testing , Models, Anatomic
9.
J Shoulder Elbow Surg ; 33(11): 2368-2376, 2024 Nov.
Article in English | MEDLINE | ID: mdl-38604397

ABSTRACT

BACKGROUND: The Bristow coracoid transfer procedure is a reliable technique for treating anterior shoulder instability in patients with large glenoid bone loss or those involved in collision sports. However, its success is marred by its inferior bone union rate of the coracoid process as compared to the Latarjet procedure. This study aimed to evaluate whether arthroscopic confirmation of the secured coracoid fixation during the Bristow procedure improves the bone union rate and clinical outcomes as compared to the open procedure. METHODS: We retrospectively reviewed 104 rugby players (n = 111 shoulders) who underwent an open (n = 66 shoulders) or arthroscopy (AS)-assisted (n = 45 shoulders) Bristow procedure at our center from 2007 to April 2019. In the AS-assisted group, the screw fixation and coracoid stability and contact were confirmed under arthroscopic visualization. Graft union was evaluated through computed tomography at 3 months, 6 months, and 1 year postoperatively. Patient-reported outcome measures were assessed based on the American Shoulder and Elbow Surgeons score, Rowe score, and satisfaction rate. Recurrence, the rate of return to play (RTP), and the frequency of pain after RTP were also assessed. RESULTS: The mean follow-up period was 73.5 (range: 45-160) months for the open group and 32.3 (range: 24-56) months for the AS-assisted group. In the former, the rates of bone union were 50%, 72.7%, and 88.9% at 3 months, 6 months, and 1 year, respectively. In contrast, the AS-assisted group had significantly greater bone union rates-88.9%, 93.3%, and 95.6% at 3 months, 6 months, and 1 year, respectively. Both groups showed significant improvement in the American Shoulder and Elbow Surgeons and Rowe scores compared to preoperative values as well as high satisfaction rates (open: 92%; AS-assisted: 95.7%). There were no statistically significant differences in the recurrence and RTP rates as well as the frequency of pain after RTP between the 2 groups. CONCLUSION: The AS-assisted procedure allows early and high bone healing without compromising the clinical outcomes.


Subject(s)
Arthroscopy , Coracoid Process , Football , Joint Instability , Shoulder Joint , Humans , Arthroscopy/methods , Joint Instability/surgery , Retrospective Studies , Male , Adult , Coracoid Process/surgery , Football/injuries , Shoulder Joint/surgery , Young Adult , Return to Sport , Adolescent , Shoulder Dislocation/surgery
10.
Am J Case Rep ; 25: e943108, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38544309

ABSTRACT

BACKGROUND Coracoid process fractures are uncommon and are often complicated by many types of shoulder girdle injuries. Previous reports have shown that osteosynthesis for isolated coracoid process fractures results in favorable outcomes and high bone union rates. However, owing to the rarity of coracoid process fractures combined with distal clavicle fractures, there are limited data to guide treatment strategies. We report a case of symptomatic nonunion despite performing osteosynthesis for fractures of the coracoid process and distal clavicle. CASE REPORT A 60-year-old man presented with left shoulder pain after falling from the back of a truck. Radiography and computed tomography (CT) findings revealed fractures of the left distal clavicle and coracoid process. We performed plate and costoclavicular fixation using a suture button for the distal clavicle fracture and cannulated cancellous screw fixation for the coracoid process fracture. However, the patient experienced severe pain around the coracoid and had limited shoulder range of motion 1 year postoperatively. CT revealed nonunion of the coracoid process, prompting a recommendation for surgery. However, despite severe persistent functional impairment, the patient refused surgery 1.5 years postoperatively. CONCLUSIONS This case suggests the potential for symptomatic nonunion of the coracoid process when using a suture-button device for a distal clavicle fracture. To prevent postoperative nonunion of the coracoid process, postoperative CT evaluation is necessary. If a symptomatic delayed bone union of coracoid process is observed, considering early removal of the suture button is recommended.


Subject(s)
Clavicle , Fractures, Bone , Male , Humans , Middle Aged , Clavicle/diagnostic imaging , Clavicle/surgery , Clavicle/injuries , Coracoid Process/diagnostic imaging , Coracoid Process/surgery , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Fracture Fixation, Internal/methods , Sutures , Treatment Outcome
11.
Chin J Traumatol ; 27(2): 121-124, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37210253

ABSTRACT

A fracture of the acromion and coracoid processes of scapula is rarely seen in the outpatient clinic, due to the acromion's anatomical position and shape, as well as the strong ligaments and muscles that are attached to it. These fractures are caused by either direct or indirect high-energy trauma injuries to the shoulder joint, leading to severe pain and a grossly restricted range of motion. Several acromial classifications were reported, but this type of longitudinal plane fracture of the acromion process in our case is yet to be described in the current literature. We present a rare combination of the coracoid process and unstable acromion bony projection fractures that have not previously been noted for this type of fracture. The closest to this is Kuhn's type III classification. A 51-year-old male presented to our emergency department complaining of the right shoulder pain and difficulty raising his arm following a 2-wheeler accident. The patient was managed by open reduction and internal fixation with 3 cannulated cancellous screws fixation and progressed well with no postoperative complications. He was asymptomatic postoperatively and regained full range of motion after 4 months.


Subject(s)
Acromion , Fractures, Bone , Male , Humans , Middle Aged , Acromion/diagnostic imaging , Acromion/surgery , Acromion/injuries , Coracoid Process/diagnostic imaging , Coracoid Process/surgery , Scapula/injuries , Scapula/surgery , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Fracture Fixation, Internal
12.
Arthroscopy ; 40(4): 1311-1324.e1, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37827435

ABSTRACT

PURPOSE: To analyze radiographic outcomes by conventional radiography, computed tomography (CT), or both and complication rates of open coracoid transfer at a minimum of 12-months follow-up. METHODS: A literature search was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, using PubMed, Medline (Ovid), and EMBASE library databases. Inclusion criteria were clinical studies reporting on open Latarjet as the primary surgical procedure(revision coracoid transfer after failed prior stabilization excluded) with postoperative radiographic outcomes at a minimum mean 1-year follow-up. Patient demographics, type of postoperative imaging modality, and radiographic outcomes and complications including graft union, osteoarthritis, and osteolysis were systematically reviewed. Data were summarized as ranges of reported values for each outcome metric. Each radiographic outcome was graphically represented in a Forest plot with point estimates of the incidence of radiographic outcomes with corresponding 95% confidence intervals and I2. RESULTS: Thirty-three studies met inclusion criteria, with a total of 1,456 shoulders. The most common postoperative imaging modality was plain radiography only (n = 848 [58.2%]), both CT and radiography (n = 287 [19.7%]), and CT only (n = 321 [22.1%]). Overall, the reported graft union rate ranged from 75% to 100%, of which 79.8% (n = 395) were detected on plain radiography. The most common reported postoperative radiographic complications after the open coracoid transfer were osteoarthritis (range, 0%-100%, pooled mean 28%), graft osteolysis (range, 0%-100%, pooled mean 30%), nonunion (range, 0%-32%, pooled mean 5.1%), malpositioned graft (range, 0%-75%, pooled mean 14.75%), hardware issues (range, 0%-9.1%, pooled mean 5%), and bone block fracture (range, 0%-8%, pooled mean 2.1%). Graft healing was achieved in a majority of cases (range, 75%-100%). CONCLUSION: Postoperative radiographic outcomes after open coracoid transfer vary greatly in definition, classification, and imaging modality of choice. Greater consistency in postoperative radiographic outcomes is essential to evaluate graft healing, osteolysis, and nonunion. LEVEL OF EVIDENCE: Level IV, systematic review of Level III-IV studies.


Subject(s)
Fractures, Bone , Joint Instability , Osteoarthritis , Osteolysis , Shoulder Dislocation , Shoulder Joint , Humans , Shoulder Joint/surgery , Joint Instability/surgery , Shoulder/surgery , Shoulder Dislocation/surgery , Osteoarthritis/diagnostic imaging , Osteoarthritis/surgery , Osteoarthritis/complications , Fractures, Bone/complications , Coracoid Process/surgery , Coracoid Process/transplantation
13.
Med Sci Monit ; 29: e937933, 2023 Apr 10.
Article in English | MEDLINE | ID: mdl-37032522

ABSTRACT

BACKGROUND This retrospective study from a single center aimed to evaluate 24 patients with coracoid process fractures of the scapula treated by baseplate three-column glenoid fixation of the 3 columns attached to the glenoid, or the scapula-glenoid construct, which includes the base of the coracoid, the scapular spine, and the lateral/scapular pillar. MATERIAL AND METHODS Twenty-four patients with 24 coracoid process fractures were treated from March 2018 to August 2020 in our hospital; 11 cases were treated with the modified technique and 13 with the conventional technique. The patients had comparable screw length, bone union time, fracture reduction, and Constant-Murley shoulder outcome scores. The significant differences between variables were tested using the t test and Fisher's exact test, while bone union and reduction position were confirmed with X-ray and CT scans. The average follow-up time was 12 months. RESULTS The mean Constant-Murley shoulder outcome score and fracture reduction did not differ significantly (P>0.05), and all patients returned to their previous occupations and levels of activity, with no loss of reduction or surgical revision at the last follow-up. Bone union time for the modified group was longer than that of the conventional group (P<0.05). However, 1 patient had a screw broken at 5 months from heavy manual labor and showed delayed union at 8 months. The lengths of the coracoid process screws in the modified group were longer than in the conventional group (P<0.01). CONCLUSIONS The findings from this retrospective study showed that baseplate three-column glenoid fixation of the coracoid process was a good surgical option for coracoid process fractures.


Subject(s)
Fractures, Bone , Shoulder Joint , Humans , Coracoid Process/surgery , Retrospective Studies , Scapula/surgery , Fractures, Bone/surgery , Shoulder Joint/surgery
14.
Tech Hand Up Extrem Surg ; 27(3): 148-150, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-36745748

ABSTRACT

A fracture of the tip of the coracoid is a rare but challenging fracture. A surgical indication is required in case of a displaced fracture. Screws and suture anchors often do not offer a reliable fixation in the case of very small fragments. We describe our hardwareless technique that consists of an osteosuture with a 90-degree suture threads configuration that we called the x-mas box technique. This procedure is cost-effective and it provides stable fixation and low complications rate.


Subject(s)
Coracoid Process , Fractures, Bone , Humans , Coracoid Process/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Upper Extremity , Suture Anchors
15.
Arch Orthop Trauma Surg ; 143(2): 959-965, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35344065

ABSTRACT

INTRODUCTION: Coracoid fractures after arthroscopic treatment of acromioclavicular (AC) joint separations lead to poor clinical outcomes. In this study, different configurations of bone tunnels in the lateral clavicle and coracoid were examined concerning the amount of stress induced in the coracoid. METHODS: An authentic 3D finite element model of an ac joint was established. Three 2.4 mm bone tunnels were inserted in the lateral clavicle, which were situated above, medially and laterally of the coracoid. Then, two 2.4 mm bone tunnels were inserted in the latter, each simulating a proximal and a distal suture button position. Von Mises stress analyses were performed to evaluate the amount of stress caused in the coracoid process by the different configurations. Then, a clinical series of radiographs was examined, the placement of the clavicle drill hole was analyzed and the number of dangerous configurations was recorded. RESULTS: The safest configuration was a proximal tunnel in the coracoid combined with a lateral bone tunnel in the clavicle, leading to an oblique traction at the coracoid. A distal bone tunnel in the coracoid and perpendicular traction as well as a proximal tunnel in the coracoid with medial traction caused the highest stresses. Anatomical placement of the clavicle drill hole does lead to configurations with smaller stresses. CONCLUSION: The bone tunnel placement with the smallest amount of shear stresses was found when the traction of the suture button was directed slightly lateral, towards the AC joint. Anatomical placement of the clavicle drill hole alone was not sufficient in preventing dangerous configurations. LEVEL OF EVIDENCE: Controlled laboratory study.


Subject(s)
Acromioclavicular Joint , Fractures, Bone , Joint Dislocations , Plastic Surgery Procedures , Humans , Coracoid Process/surgery , Finite Element Analysis , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Fractures, Bone/etiology , Acromioclavicular Joint/diagnostic imaging , Acromioclavicular Joint/surgery , Clavicle/surgery , Ligaments, Articular/surgery , Joint Dislocations/diagnostic imaging , Joint Dislocations/etiology , Joint Dislocations/surgery
16.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 36(9): 1072-1077, 2022 Sep 15.
Article in Chinese | MEDLINE | ID: mdl-36111467

ABSTRACT

Objective: To evaluate the short-term effectiveness of modified arthroscopic Latarjet procedure with double EndoButtons for recurrent anterior shoulder dislocation. Methods: Between January 2019 and November 2020, 36 patients with recurrent anterior shoulder dislocation were treated by modified arthroscopic Latarjet procedure with double EndoButtons. There were 26 males and 10 females, with an average age of 27.8 years (range, 18-36 years). The number of shoulder dislocations ranged from 3 to 12 times, with an average of 6.5 times. The disease duration ranged from 5 to 36 months, with an average of 16.2 months. Preoperative shoulder fear test was positive, and the Beighton score of joint relaxation was 0-4, with an average of 1.3. Imaging examination showed that the defect width of the ipsilateral glenoid bone was 16%-28%, with an average of 21.5%. Postoperative complications, recurrent dislocation, subluxation, and instability of shoulder joint were recorded. Shoulder range of motion was examined, including forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation. Shoulder joint function was evaluated by Walch-Duplay score, American Association for Shoulder and Elbow Surgery Score (ASES), and ROWE score. X-ray film and CT images were taken to observe the shaping of coracoid process graft. Results: All incisions healed by first intention, and no vascular or nerve injury occurred. All patients were followed up 12-28 months, with an average of 19.9 months. During follow-up, no shoulder dislocation recurred, and shoulder fear test was negative. At last follow-up, there was no significant difference in shoulder forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation when compared with preoperative values (P>0.05). The Walch-Duplay score, ASES score, and ROWE score of shoulder function significantly improved (P<0.05). Postoperative imaging examination showed that coracoid process graft was at the same level with the glenoid in 33 cases (91.7%), medial in 1 case (2.8%), and lateral in 2 cases (5.6%); the center of coracoid process graft was mainly located between 3 to 5 o'clock in 33 cases (91.7%), higher than 3 o'clock in 1 case (2.8%), and lower than 5 o'clock in 2 cases (5.6%). There was no obvious glenohumeral joint degeneration during follow-up, and the coracoid process graft gradually formed concentric circles with the humeral head. Conclusion: The modified arthroscopic Latarjet procedure with double EndoButtons can effectively treat recurrent anterior shoulder dislocation, and the short-term effectiveness is satisfactory, and the position of coracoid process graft is accurate.


Subject(s)
Shoulder Dislocation , Shoulder Joint , Adult , Arthroplasty/methods , Arthroscopy/methods , Coracoid Process/surgery , Female , Humans , Male , Shoulder Dislocation/surgery , Shoulder Joint/surgery
17.
Orthop Surg ; 14(10): 2692-2700, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36093615

ABSTRACT

OBJECTIVE: An agreement has not been reached on optimal locations of bone tunnels for coracoclavicular ligament (CCL) reconstruction for acromioclavicular joint dislocation (ACD). This study aims to identify the convergence point (cP) between the coracoid process and clavicle in the Chinese population to assist surgeons in reconstructing the CCL for ACD. METHODS: From 2014 to 2020, 483 CT scans of the shoulders of 270 male and 213 female patients (247 right and 236 left shoulders) were collected and studied retrospectively. By overlapping the images of the transverse plane of the coracoid process and the clavicle, points a and b, and the midpoint ab (cP) were determined. Then, a series of parameters through point cP in the transverse and sagittal planes were measured. In the transverse plane this included the distance from point cP to the tip of the coracoid process (cP-cor),the distance between the medial and lateral margins of the coracoid process through point cP (Med-lat cor), the distance from point cP to the acromioclavicular joint (cP-ac), and the distance between the anteroposterior margin of the clavicle through point cP (Ap-clav). In the sagittal plane, this included the craniocaudal segment of the coracoid process (Cc-cor), and the craniocaudal segment of the clavicle (Cc-clav). The sex and side differences of these measurements were also analyzed by two radiologists. RESULTS: Based on the following measurements, point cP was determined. For male patients, the cP-cor was 28.02 ± 3.43 mm, Med-lat cor was 22.78 ± 2.80 mm, Cc-cor was 15.11 ± 2.13 mm, cP-ac was 29.24 ± 3.84 mm, Ap-clav was 18.27 ± 2.46 mm, and Cc-clav was 10.09 ± 1.56 mm. For female patients, the cP-cor was 25.20 ± 3.26 mm, Med-lat cor was 20.21 ± 2.97 mm, Cc-cor was 13.03 ± 1.77 mm, cP-ac was 26.66 ± 3.45 mm, Ap-clav was 16.10 ± 2.30 mm, and Cc-clav was 8.91 ± 1.40 mm. All the measurements of female patients were lower than those of male patients (p < 0.01). Between sides, only cP-ac of the left shoulders was significantly lower than those of the right shoulders (p < 0.05), with no significant differences in other parameters between sides (p > 0.05). CONCLUSION: The results of this study identified the locations of bone tunnel-cP in the coracoid process and clavicle for the CCL reconstruction in ACD. Moreover, the findings indicated that surgeons should be more cautious in operating on female patients and that the cP-ac of left shoulders should be set lower than that of right shoulders.


Subject(s)
Acromioclavicular Joint , Shoulder Dislocation , Acromioclavicular Joint/diagnostic imaging , Acromioclavicular Joint/surgery , Clavicle/diagnostic imaging , Clavicle/surgery , Coracoid Process/diagnostic imaging , Coracoid Process/surgery , Female , Humans , Ligaments, Articular/diagnostic imaging , Ligaments, Articular/surgery , Male , Retrospective Studies , Shoulder Dislocation/surgery , Tomography, X-Ray Computed
18.
J Orthop Surg Res ; 17(1): 371, 2022 Jul 30.
Article in English | MEDLINE | ID: mdl-35907891

ABSTRACT

BACKGROUND: We created patient-based 3D finite-element (FE) models that simulate the congruent-arc Latarjet (CAL) and traditional Latarjet (TL) procedures and then compared their stress distribution patterns with different arm positions and glenoid defects. METHODS: The computed tomography data of 10 adult patients (9 men and 1 woman, ages: 18-50 years) were used to develop the 3D FE glenohumeral joint models. Twenty-five and 35% bony defects were created on the anterior glenoid rim, and the coracoid process was transferred flush with the glenoid by the traditional and congruent-arc techniques using two half-threaded screws. A load was applied to the greater tuberosity toward the center of the glenoid, and a tensile force (20 N) was applied to the coracoid tip along the direction of the conjoint tendon. The distribution patterns of the von Mises stress in the traditional and congruent-arc Latarjet techniques were compared. RESULTS: The mean von Mises on the graft was significantly greater for the TL technique than for the CAL. While the von Mises stress was greater in the distal medial part of the graft in the TL models, a higher stress concentration was observed in the distal lateral edge of the coracoid graft in the CAL models. The proximal medial part of the graft exhibited significantly lower von Mises stress than the distal medial part when compared according to technique, defect size, and arm position. Increasing the glenoid defect from 25 to 35% resulted in a significant increase in stress on the lateral side of the graft in both models. CONCLUSION: The stress distribution patterns and stress magnitude of the coracoid grafts differed according to the procedure. Due to placing less stress on the proximal-medial part of the graft, the CAL technique may lead to insufficient stimulation for bone formation at the graft-glenoid interface, resulting in a higher incidence of graft osteolysis. Clinical relevance The CAL technique may lead to a higher incidence of graft osteolysis. LEVEL OF EVIDENCE: Basic Science Study; Computer Modeling.


Subject(s)
Joint Instability , Osteolysis , Shoulder Joint , Adolescent , Adult , Bone Transplantation/methods , Coracoid Process/diagnostic imaging , Coracoid Process/surgery , Female , Humans , Joint Instability/surgery , Male , Middle Aged , Scapula/diagnostic imaging , Scapula/surgery , Shoulder Joint/surgery , Young Adult
19.
J Shoulder Elbow Surg ; 31(3): 623-628, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34487823

ABSTRACT

Nineteen patients presented with an unsightly deformity of the shoulder, pain or discomfort at the medial scapular border, pseudo nonparalytic scapular winging, and thoracic outlet symptoms after excessive resection of the clavicle for either complete acromioclavicular separation or displaced fracture of the outer clavicle, which allows the scapula and shoulder to rotate anteriorly and inferiorly on the chest creating traction on the medial scapular muscles and the brachial plexus resulting in pseudo nonparalytic winging and thoracic outlet symptoms. RESULTS: All underwent transfer of the coracoid process with the attached conjoined tendon to the end of the clavicle, restoring length and alignment. Eighteen patients were evaluated at a mean of 13.3 years. Seventeen had resolution of symptoms, restored alignment of the clavicle with the shoulder, improved appearance, healed transfer, and were pleased with the outcome. One patient was lost to follow-up but was considered a failure at his last visit. In a second patient, the transfer healed in a tilted position and the patient was dissatisfied with the appearance but otherwise had resolution of his symptoms. The mean American Shoulder and Elbow Surgeons Outcome Score improved from 53.2 preoperatively to 87.4 postoperatively (P < .02). CONCLUSION: This is the first report of using this transfer to restore length and alignment of an excessively short, unstable clavicle. The transfer succeeded in improving the appearance and symptoms in this complication of an excessively short, unstable clavicle.


Subject(s)
Clavicle , Fractures, Bone , Clavicle/surgery , Coracoid Process/surgery , Fractures, Bone/surgery , Humans , Scapula/surgery , Tendons
20.
Arch Orthop Trauma Surg ; 142(3): 387-393, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33113015

ABSTRACT

INTRODUCTION: Joint replacement surgery as a treatment for glenohumeral arthritis with glenoid bone loss is challenging. The aim of this study is to offer an anatomical orientation for glenoid reconstruction. METHODS: In this study, we measured size, inclination and version of the glenoid surface, as well as the distance between the articular line of the glenoid, base of the coracoid process, and acromion using computer tomographic (CT) imaging of 131 study participants aged 19-88 years in the period of 2010-2013. RESULTS: We measured a mean distance of 6.5 ± 0.2 mm from the glenoid articular line to the base of the coracoid process in the transverse CT plane. Body height has shown no significant impact on the glenoid morphology. We observed significant differences between males and females: The glenoid appeared to be located 5.2 ± 0.9 mm higher and the humeral head was 4.5 ± 0.7 mm larger in male subjects compared with females (r = .699; p < .01). CONCLUSION: In our study, the base of the coracoid offers an anatomical reference during reconstruction of the glenoid in primary and revision shoulder arthroplasty. As only 2D-CT imaging allows for accurate assessment of glenoid bone defects, we consider conventional X-ray imaging insufficient for proper preoperative planning before shoulder arthroplasty. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Shoulder , Arthroplasty, Replacement , Glenoid Cavity , Shoulder Joint , Adult , Aged , Aged, 80 and over , Computers , Coracoid Process/surgery , Female , Glenoid Cavity/diagnostic imaging , Glenoid Cavity/surgery , Humans , Male , Middle Aged , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Tomography, X-Ray Computed , Young Adult
SELECTION OF CITATIONS