Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.154
Filter
4.
BMJ Open ; 14(5): e079881, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724059

ABSTRACT

OBJECTIVES: Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF) that has recently become available in the UK National Health Service (NHS). We provide the first known economic evaluation of the technology. METHODS: A cost-comparison model was developed to compare the expected 12-month costs of treating AF using the pentaspline PFA catheter compared with cryoablation for a single hypothetical patient. Model parameters were based on a recent cost-effectiveness analysis by the National Institute for Health and Care Excellence where possible or published literature otherwise. Deterministic sensitivity, scenario and threshold analyses were conducted. RESULTS: Costs for a single patient treated with PFA were -3% (-£343) less over 12 months than those who received treatment with cryoablation. PFA was associated with 16% higher catheter costs but repeat ablation costs were over 50% less, driven by a reduction in repeat ablations required. Costs of managing complications were -£211 less in total for PFA compared with cryoablation. CONCLUSIONS: Routine adoption of PFA with the pentaspline PFA catheter looks to be as affordable for the NHS as current treatment alternative cryoablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cost-Benefit Analysis , Cryosurgery , State Medicine , Atrial Fibrillation/surgery , Atrial Fibrillation/economics , Atrial Fibrillation/therapy , Humans , Cryosurgery/economics , Cryosurgery/methods , United Kingdom , Catheter Ablation/economics , Catheter Ablation/methods , State Medicine/economics
5.
RMD Open ; 10(2)2024 May 09.
Article in English | MEDLINE | ID: mdl-38724261

ABSTRACT

OBJECTIVE: A comparison of cryoneurolysis or radio frequency (RF) with placebo in patients with facetogenic chronic low back pain (LBP) for patient global impression of change (PGIC), pain intensity, function and quality of life, with 1-year follow-up. DESIGN: Single-centre, single-blinded placebo-controlled randomised controlled trial. SETTING: Single-centre study. PARTICIPANTS: Inclusion from March 2020 to September 2022: consenting adults over 18 years of age, LBP>3 months, average Numeric Rating Scale LBP≥4 average last 14 days and a positive response to a diagnostic medial branch block (>50% pain reduction after 60 min). INTERVENTIONS: 120 patients were block randomised 1:1:1 to cryoneurolysis, RF or placebo of the medial branch nerves. Physical therapy was added after 4 weeks for all groups. MAIN OUTCOME MEASURES: Primary outcome was PGIC 4 weeks after the intervention. Secondary outcomes included pain intensity (Numeric Rating Scale, NRS), quality of life (Short Form 36, EQ-5D-5L), disability (Oswestry Disability Index), depression (Major Depression Inventory) and catastrophising (Pain Catastrophising Scale). Outcomes were measured at 4 weeks, 3, 6 and 12 months. RESULTS: There was no statistically significant difference in PGIC at 4 weeks between cryoneurolysis and placebo (risk ratio (RR) 2; 95% CI 0.75 to 5.33, p=0.17) and RF and placebo (RR 1.6; 95% CI 0.57 to 4.49, p=0.37), except PGIC for cryoneurolysis at 6-month follow-up (RR 5.1; 95% CI 1.20 to 22.03, p=0.03). No statistically significant differences were found in secondary follow-up endpoints. CONCLUSIONS: Denervation of the medial branch nerve by either cryoneurolysis or RF compared with placebo did not demonstrate significant improvement in PGIC, pain intensity, function and quality of life in patients with facetogenic chronic LBP at short-term or long-term follow-up. TRIAL REGISTRATION NUMBER: NCT04786145.


Subject(s)
Chronic Pain , Low Back Pain , Pain Measurement , Quality of Life , Radiofrequency Ablation , Humans , Low Back Pain/therapy , Low Back Pain/etiology , Low Back Pain/psychology , Male , Female , Middle Aged , Radiofrequency Ablation/methods , Radiofrequency Ablation/adverse effects , Chronic Pain/therapy , Chronic Pain/etiology , Chronic Pain/psychology , Treatment Outcome , Adult , Single-Blind Method , Cryosurgery/methods , Aged , Pain Management/methods
7.
Braz J Cardiovasc Surg ; 39(2): e20230354, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748605

ABSTRACT

Postoperative pain after cardiac surgery plays an important role in the patient's recovery process. In particular, pain at the chest tube site can negatively affect the comfort and recovery of these patients. Effective pain control minimizes the risk of many complications. Oral and intravenous analgesics, epidural anesthesia, paravertebral block, and intercostal nerve blockade are used in chest tube pain control. We routinely use the surgical cryoablation method in the presence of atrial fibrillation in the preoperative period of cardiac surgery in our clinic. Here we aimed to describe our method of using the cryoablation catheter for intercostal nerve blockade.


Subject(s)
Atrial Fibrillation , Chest Tubes , Cryosurgery , Pain, Postoperative , Humans , Atrial Fibrillation/surgery , Pain, Postoperative/prevention & control , Pain, Postoperative/etiology , Cryosurgery/methods , Cryosurgery/instrumentation , Nerve Block/methods , Cardiac Surgical Procedures/methods , Intercostal Nerves , Treatment Outcome , Catheters
8.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38767127

ABSTRACT

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Subject(s)
Cryosurgery , Pulmonary Veins , Cryosurgery/methods , Cryosurgery/instrumentation , Cryosurgery/adverse effects , Animals , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Swine , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Humans , Models, Cardiovascular , Muscle, Skeletal/surgery , Models, Anatomic
9.
Eur J Med Res ; 29(1): 268, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702744

ABSTRACT

RATIONALE AND OBJECTIVES: Bleeding is a major complication of transbronchial lung cryobiopsy (TBLC), and pre-placing a bronchial balloon is one of the clinical practices used to prevent it, but with very weak evidence, which should be confirmed. This study aimed to conduct whether pre-placing a bronchial balloon in TBLC for diagnosing interstitial lung disease (ILD) is more safety. MATERIALS AND METHODS: In this prospective, single-center, randomized controlled trial, patients with suspected ILD were enrolled and randomly assigned to pre-placed balloon and none-pre-placed balloon groups. The primary outcome was incidence of moderate bleeding in each group. The secondary endpoints were the incidence of severe bleeding, pneumothorax, and other procedural complications. RESULTS: Exactly 250 patients were enrolled between August 2019 and March 2022, with 125 in each group. There were no significant differences in severe bleeding between the none-pre-placed balloon group and pre-placed balloon group (1.6% vs. 0.8%; adjusted p = 0.520), while more moderate bleeding occurred in the none-pre-placed balloon group (26.4% vs. 6.4%, adjusted p = 0.001), as well as more use of hemostatic drug (28.0% vs. 6.4%, adjusted p = 0.001). Three patients in the none-pre-placed balloon group used the bronchial balloon. More samples could be acquired in the pre-placed balloon group than in the none-pre-placed balloon group (3.8 ± 0.9 vs. 3.1 ± 0.9, p < 0.001). There were no significant differences in multidisciplinary discussion (MDD) between the two groups (89.6% vs. 91.2%, adjusted p = 0.182). CONCLUSION: A pre-placed bronchial balloon can reduce the incidence of moderate bleeding and increase the confidence of the bronchoscopists. However, it had no effect on increasing the diagnostic rate of MDD and reducing severe bleeding. REGISTRATION NUMBER: NCT04047667 ( www. CLINICALTRIALS: gov identifier).


Subject(s)
Bronchoscopy , Cryosurgery , Lung Diseases, Interstitial , Humans , Male , Female , Lung Diseases, Interstitial/diagnosis , Lung Diseases, Interstitial/pathology , Middle Aged , Aged , Prospective Studies , Bronchoscopy/methods , Bronchoscopy/adverse effects , Cryosurgery/methods , Cryosurgery/adverse effects , Biopsy/methods , Biopsy/adverse effects , Hemorrhage/etiology , Hemorrhage/diagnosis , Hemorrhage/prevention & control , Lung/pathology , Bronchi/pathology
11.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38582974

ABSTRACT

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Subject(s)
Cardiomyopathies , Catheter Ablation , Cryosurgery , Tachycardia, Ventricular , Aged , Humans , Middle Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Cicatrix/complications , Cryosurgery/adverse effects , Prospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Temperature , Treatment Outcome
12.
Curr Opin Pulm Med ; 30(4): 337-345, 2024 07 01.
Article in English | MEDLINE | ID: mdl-38682600

ABSTRACT

PURPOSE OF REVIEW: This review article focuses on bronchoscopic treatment of early-stage peripheral lung cancer. RECENT FINDINGS: Bronchoscopic treatment modalities have garnered considerable attention for early-stage lung cancer. Studies using photodynamic therapy, thermal vapor ablation, laser ablation, cryoablation, and intra-tumoral injection have recently been published. However, the evidence supporting these approaches largely derives from single-arm studies with small sample sizes. Based on the IDEAL-D framework, no technology has progressed passed the idea phase (1). The main weakness of these technologies to date is lack of evidence suggesting they can achieve local control. Presently, no bronchoscopic intervention for lung cancer has sufficient data to warrant its use as part of the standard of care. SUMMARY: Despite notable progress, current technologies remain suboptimal, and there is insufficient evidence to support their use outside of a research setting.


Subject(s)
Bronchoscopy , Lung Neoplasms , Neoplasm Staging , Humans , Lung Neoplasms/pathology , Lung Neoplasms/therapy , Lung Neoplasms/surgery , Bronchoscopy/methods , Photochemotherapy/methods , Laser Therapy/methods , Cryosurgery/methods , Treatment Outcome
13.
Curr Oncol Rep ; 26(5): 573-582, 2024 05.
Article in English | MEDLINE | ID: mdl-38625653

ABSTRACT

PURPOSE OF REVIEW: To review the current status of kidney tumor ablation in patients with substantial kidney impairment. RECENT FINDINGS: Few reports of kidney tumor ablation in such patients have recently been published. The reported prevalence of patients with stage 4 or 5 chronic kidney disease (CKD) among patients undergoing ablation is 2.0%-10%. In patients with stage 4 or 5 CKD, local tumor control rates were 88%-100%. The effect of ablation on CKD stage is unclear, and the observed deteriorations in kidney function are consistent with both the effect of cryoablation and the natural course of advanced CKD. According to guidelines, active surveillance may be selected. The goals of treatment are complete tumor removal and maintenance of kidney function, both of which can be met by ablation. Given the limited treatment options, ablation may play a pivotal role in the management of patients with advanced CKD.


Subject(s)
Kidney Neoplasms , Renal Insufficiency, Chronic , Humans , Kidney Neoplasms/surgery , Kidney Neoplasms/pathology , Kidney Neoplasms/complications , Renal Insufficiency, Chronic/complications , Cryosurgery , Ablation Techniques/methods
14.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38624037

ABSTRACT

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Subject(s)
Atrial Fibrillation , Body Mass Index , Cryosurgery , Obesity , Pulmonary Veins , Recurrence , Registries , Humans , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Male , Female , Middle Aged , Republic of Korea/epidemiology , Aged , Treatment Outcome , Risk Factors , Pulmonary Veins/surgery , Obesity/complications , Thinness/complications , Time Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology
15.
Eur J Radiol ; 175: 111465, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38621339

ABSTRACT

PURPOSE: Assess safety and local tumor progression-free survival (LTPFS) of percutaneous cryoablation for pleural-based thoracic malignancies. MATERIALS AND METHODS: Retrospective study of 46 patients (17 treated for palliation; 9 for oligoprogression; 20 for curative intent), with 62 pleural-based thoracic lesions, treated in 59 cryoablation sessions. Patients were treated from 9/2005-11/2021 with CryoCare CS (Varian, Irvine, CA) or IceFORCE (Boston Scientific, Marlborough, MA) systems. For tumors treated with curative intent and/or oligoprogression, LTPFS of the treated tumor(s) and overall survival (OS) were estimated using Kaplan-Meier method. Post-operative complications were reported for all sessions, including those with palliative intent; univariate analyses were used to calculate factors associated with increased complication risk. RESULTS: Median number of tumors treated in a single treatment session was 1 (range 1-4). Largest dimension of the treated tumor was 2.1 cm [IQR:0.9-5 cm]. Of the 59 treatments, 98.3 % were technically successful. Median LTPFS was 14.4 (95 % CI: 9.4-25.6) months. Tumor size was a significant predictor of LTPFS (HR: 1.21, 95 % CI: 1.03-1.44, p = 0.023). Median OS was 52.4 (28.1-NR) months. Complications occurred in 28/59 sessions (47.5 %); 2/59 (3.4 %) were ≥ grade D by Society of Interventional Radiology adverse event criteria (death; hypoxia requiring supplemental oxygen upon discharge). Pain and pneumothorax were the most common complications. The length of lung parenchyma traversed was a significant predictor of pneumothorax: HR 0.48 (95 %CI: 0.14-0.83), p = 0.0024. CONCLUSION: Percutaneous cryoablation for pleural lesions is associated with a long duration of local control and most complications were minor and self-limited.


Subject(s)
Cryosurgery , Pleural Neoplasms , Humans , Cryosurgery/methods , Cryosurgery/adverse effects , Male , Female , Middle Aged , Retrospective Studies , Aged , Treatment Outcome , Pleural Neoplasms/surgery , Adult , Aged, 80 and over , Postoperative Complications , Survival Rate
16.
BMJ Case Rep ; 17(4)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627044

ABSTRACT

Breast cryoablation for palliative and curative treatment of breast cancer has been performed for decades. Although there is a recent resurgence of interest in breast cryoablation with curative intent for unifocal, hormone receptor-positive, human epidermal growth factor receptor 2-negative breast cancer, this report highlights the essential role that cryoablation can play in the palliative treatment of multicentric oestrogen and progesterone receptor-negative and human epidermal growth factor receptor 2-negative (triple-negative) breast cancer, meeting the select pretreatment objectives such as breast or nipple pain relief and prevention of tumour erosion through the skin or nipple in patients who have failed or cannot tolerate the standard of care treatment.


Subject(s)
Breast Neoplasms , Cryosurgery , Triple Negative Breast Neoplasms , Humans , Female , Triple Negative Breast Neoplasms/surgery , Triple Negative Breast Neoplasms/pathology , Breast Neoplasms/pathology , Palliative Care , Pain Management , Estrogens , Receptors, Progesterone/metabolism , Receptor, ErbB-2/metabolism
17.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38588039

ABSTRACT

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Subject(s)
Atrial Fibrillation , Cryosurgery , Peripheral Nerve Injuries , Phrenic Nerve , Pulmonary Veins , Registries , Humans , Phrenic Nerve/injuries , Male , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Pulmonary Veins/surgery , Aged , Cryosurgery/adverse effects , Cryosurgery/methods , Prospective Studies , Incidence , Peripheral Nerve Injuries/etiology , Peripheral Nerve Injuries/epidemiology , Peripheral Nerve Injuries/prevention & control , Middle Aged , Treatment Outcome , Catheter Ablation/adverse effects
18.
Ther Umsch ; 81(1): 21-23, 2024 Feb.
Article in German | MEDLINE | ID: mdl-38655830

ABSTRACT

INTRODUCTION: Cryobiopsies for the differentiation of interstitial pneumopathies Abstract: Definitive diagnosis of interstitial pneumopathy is often difficult. In order to establish antifibrotic therapy, it is necessary to narrow down the aetiology and, in up to 40% of cases, obtain histological confirmation. The establishment of the endoscopic method of cryobiopsy achieves a diagnostic yield of 76-80% with significantly fewer complications compared to surgical lung biopsy.


Subject(s)
Lung Diseases, Interstitial , Humans , Lung Diseases, Interstitial/diagnosis , Lung Diseases, Interstitial/pathology , Diagnosis, Differential , Biopsy , Lung/pathology , Cryosurgery/methods , Bronchoscopy/methods
19.
Cardiovasc Intervent Radiol ; 47(5): 567-572, 2024 May.
Article in English | MEDLINE | ID: mdl-38570342

ABSTRACT

PURPOSE: Complete lymph node dissection is the recommended treatment for clinically detectable lymph nodes in stage III melanoma. This surgery is associated with substantial morbidity. We hypothesize that combining percutaneous imaging-guided cryoablation of locoregional lymph nodes metastases with neoadjuvant in situ and systemic immunotherapy could allow disease control and evaluate the feasibility of this combination in this proof-of-concept study. METHODS: We enrolled 15 patients with stage IIIB/IIIC melanoma. Patients were treated as follows: a single 240 mg flat dose infusion of nivolumab on day 1, cryoablation under local anesthesia using CT on day 2, and a single intralesional injection of 10-20 mg of ipilimumab into the lymphadenopathy treated by cryotherapy on day 3. Five-eight weeks after this procedure, complete lymph node dissection was performed according to routine care. The primary outcome measure of this study was feasibility, measured as the number of failures (i.e., inability to complete the entire procedure). RESULTS: The procedure was carried out successfully in 15 out of 15 patients with an observed number of failures of 0. The Bayesian analysis showed an estimated failure rate of 4.2% [0.2-20.6]. Eight patients (53%) had adverse events secondary to either immunotherapy or cryotherapy. Grade 3/4 events occurred in three patients, but all resolved quickly and patients could proceed to surgery as scheduled. Eight patients (53%) had a pathological complete or near complete response. CONCLUSION: Combining percutaneous cryotherapy with in situ ipilimumab and systemic nivolumab for stage III resectable melanoma is feasible with tolerable toxicity.


Subject(s)
Cryosurgery , Ipilimumab , Lymphatic Metastasis , Melanoma , Neoadjuvant Therapy , Nivolumab , Proof of Concept Study , Skin Neoplasms , Humans , Melanoma/therapy , Melanoma/pathology , Melanoma/surgery , Melanoma/secondary , Male , Female , Middle Aged , Cryosurgery/methods , Aged , Ipilimumab/therapeutic use , Skin Neoplasms/pathology , Skin Neoplasms/therapy , Nivolumab/therapeutic use , Immunotherapy/methods , Neoplasm Staging , Lymph Node Excision , Adult , Feasibility Studies , Antineoplastic Agents, Immunological/therapeutic use , Tomography, X-Ray Computed , Treatment Outcome , Combined Modality Therapy
20.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38637325

ABSTRACT

AIMS: Left atrial appendage electrical isolation (LAAEI) has demonstrated a significant enhancement in the success rate of atrial fibrillation (AF) ablation. Nevertheless, concerns persist about the safety of LAAEI, particularly regarding alterations in left atrial appendage (LAA) flow velocity and the potential risks of thrombus. This study aimed to assess the efficacy and safety of LAAEI, investigating changes in LAA flow velocity in canines. METHODS AND RESULTS: The study comprised a total of 10 canines. The LAAEI procedure used by a 23 mm cryoballoon of the second generation was conducted at least 180 s. Intracardiac ultrasonography (ICE) was employed to quantify the velocity flow of the LAA both prior to and following LAAEI. Following a 3-month period, subsequent evaluations were performed to assess the LAA velocity flow and the potential reconnection. Histopathological examination was conducted. Left atrial appendage electrical isolation was effectively accomplished in all canines, resulting in a 100% acute success rate (10/10). The flow velocity in the LAA showed a notable reduction during LAAEI as compared with the values before the ablation procedure (53.12 ± 5.89 vs. 42.01 ± 9.22 cm/s, P = 0.007). After the follow-up, reconnection was observed in four canines, leading to a success rate of LAAEI of 60% (6/10). The flow velocity in the LAA was consistently lower (53.12 ± 5.89 vs. 44.33 ± 10.49 cm/s, P = 0.006), and no blood clot development was observed. The histopathological study indicated that there was consistent and complete injury to the LAA, affecting all layers of its wall. The injured tissue was subsequently replaced by fibrous tissue. CONCLUSION: The feasibility of using cryoballoon ablation for LAAEI was confirmed in canines, leading to a significant reduction of LAA flow velocity after ablation. Some restoration of LAA flow velocity after ablation may be linked to the passive movement of the LAA and potential reconnecting. However, this conclusion is limited to animal study; more clinical data are needed to further illustrate the safety and accessibility of LAAEI in humans.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cryosurgery , Dogs , Animals , Atrial Appendage/surgery , Cryosurgery/methods , Cryosurgery/adverse effects , Cryosurgery/instrumentation , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Equipment Design , Blood Flow Velocity , Treatment Outcome , Male
SELECTION OF CITATIONS
SEARCH DETAIL