Methods Cell Biol ; 189: 169-188, 2024.
Article in English | MEDLINE | ID: mdl-39393882

ABSTRACT

Multiparametric flow cytometry (MFC) represents an essential tool for immune monitoring, and validation of MFC panels is a fundamental prerequisite in routine laboratory settings as well as for translational and clinical research purposes. Regulatory T cells (TREGs) constitute a subset of CD4+ effector T cells that modulate the immune response in numerous settings, including autoimmune disease, allergy, microbial infection, tumor immunity, transplantation, and more. These cells comprise a small fraction of total CD4+ T cells in human peripheral blood and mouse spleen. In oncology, TREG cells are highly relevant, as they are involved in the suppression of the anti-tumor response in many types of cancer, to the extent that the first immune checkpoint inhibitor approved for clinical use in humans was a monoclonal antibody directed against CTLA-4, a molecule functionally associated with TREGs. Due to all these factors, robust assays are mandatory to accurately determine TREG cell frequency and function. Here, we describe the validation of an 8-color flow-cytometry protocol for TREG detection and analysis in a real-world laboratory scenario. The entire process includes the workflow plan and the standard operating procedure resembling each phase, from the panel design to the staining, acquisition, and analysis steps. Validation is planned to be performed in replicates on fresh whole blood samples derived from multiple healthy subjects. The analytical validity of the TREG cell assay is ensured by testing the intra-assay accuracy. The detailed procedure for the entire process is accompanied by important troubleshooting suggestions and other useful tips.


Subject(s)
Flow Cytometry , T-Lymphocytes, Regulatory , Flow Cytometry/methods , Flow Cytometry/standards , T-Lymphocytes, Regulatory/immunology , Humans , Animals , Mice
2.
Immunohorizons ; 8(9): 622-634, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39248805

ABSTRACT

Human PBMC-based assays are often used as biomarkers for the diagnosis and prognosis of disease, as well as for the prediction and tracking of response to biological therapeutics. However, the development and use of PBMC-based biomarker assays is often limited by poor reproducibility. Complex immunological assays can be further complicated by variation in cell handling before analysis, especially when using cryopreserved cells. Variation in postthaw viability is further increased if PBMC isolation and cryopreservation are done more than a few hours after collection. There is currently a lack of evidence-based standards for the minimal PBMC viability or "fitness" required to ensure the integrity and reproducibility of immune cell-based assays. In this study, we use an "induced fail" approach to examine the effect of thawed human PBMC fitness on four flow cytometry-based assays. We found that cell permeability-based viability stains at the time of thawing did not accurately quantify cell fitness, whereas a combined measurement of metabolic activity and early apoptosis markers did. Investigation of the impact of different types and levels of damage on PBMC-based assays revealed that only when cells were >60-70% live and apoptosis negative did biomarker values cease to be determined by cell fitness rather than the inherent biology of the cells. These data show that, to reproducibly measure immunological biomarkers using cryopreserved PBMCs, minimal acceptable standards for cell fitness should be incorporated into the assay protocol.


Subject(s)
Cell Survival , Cryopreservation , Flow Cytometry , Leukocytes, Mononuclear , Humans , Leukocytes, Mononuclear/immunology , Leukocytes, Mononuclear/metabolism , Flow Cytometry/methods , Flow Cytometry/standards , Reproducibility of Results , Biomarkers/metabolism , Apoptosis
3.
Cytometry A ; 105(10): 752-762, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39238272

ABSTRACT

Imaging flow cytometry (IFCM) is a technique that can detect, size, and phenotype extracellular vesicles (EVs) at high throughput (thousands/minute) in complex biofluids without prior EV isolation. However, the generated signals are expressed in arbitrary units, which hinders data interpretation and comparison of measurement results between instruments and institutes. While fluorescence calibration can be readily achieved, calibration of side scatter (SSC) signals presents an ongoing challenge for IFCM. Here, we present an approach to relate the SSC signals to particle size for IFCM, and perform a comparability study between three different IFCMs using a plasma EV test sample (PEVTES). SSC signals for different sizes of polystyrene (PS) and hollow organosilica beads (HOBs) were acquired with a 405 nm 120 mW laser without a notch filter before detection. Mie theory was applied to relate scatter signals to particle size. Fluorescence calibration was accomplished with 2 µm phycoerythrin (PE) and allophycocyanin (APC) MESF beads. Size and fluorescence calibration was performed for three IFCMs in two laboratories. CD235a-PE and CD61-APC stained PEVTES were used as EV-containing samples. EV concentrations were compared between instruments within a size range of 100-1000 nm and a fluorescence intensity range of 3-10,000 MESF. 81 nm PS beads could be readily discerned from background based on their SSC signals. Fitting of the obtained PS bead SSC signals with Mie theory resulted in a coefficient of determination >0.99 between theory and data for all three IFCMs. 216 nm HOBs were detected with all instruments, and confirmed the sensitivity to detect EVs by SSC. The lower limit of detection regarding EV-size for this study was determined to be ~100 nm for all instruments. Size and fluorescence calibration of IFCM data increased cross-instrument data comparability with the coefficient of variation decreasing from 33% to 21%. Here we demonstrate - for the first time - scatter calibration of an IFCM using the 405 nm laser. The quality of the scatter-to-diameter relation and scatter sensitivity of the IFCMs are similar to the most sensitive commercially available flow cytometers. This development will support the reliability of EV research with IFCM by providing robust standardization and reproducibility, which are pre-requisites for understanding the biological significance of EVs.


Subject(s)
Flow Cytometry , Flow Cytometry/methods , Flow Cytometry/standards , Calibration , Humans , Extracellular Vesicles/chemistry , Particle Size , Fluorescence , Polystyrenes/chemistry , Phycoerythrin/chemistry , Image Cytometry/methods
4.
Scand J Clin Lab Invest ; 84(4): 273-277, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39003578

ABSTRACT

Chimeric antigen receptor-T (CAR-T) cell therapy is currently the best-known type of immune effector cells therapy. For CAR T-cell therapy, the determination of CD3+ T cells is necessary for the quality control of fresh leukapheresis product as starting material. The aim was to validate analytical method for quantification of percentage and absolute count of T lymphocyte subtypes (CD3+, CD4+ and CD8+ cells) in fresh apheresis products using single-platform method on flow cytometer BD FACS Canto II. Validation study included determination of precision, trueness (bias), assessment of linearity, carryover, comparison of results obtained with two different protocols on flow cytometer for CD3+ cells determination and stability study. For between-run precision coefficients of variation (CVs) were <20%, as well as bias for all T-lymphocyte subtypes. For within-run precision, CVs were <10%, except for low CD8+ cell (percentage 10.51% and viable absolute count 12.37%). Comparison of results obtained with two different protocols for CD3+ cells determination shows no statistically significant difference. Statistically significant differences between results of the analysis of CD4+ cells in fresh samples and results obtained after storage at 4 °C (p = .004) and at room temperature (p = .018) were found. In conclusion, method for enumeration of T-lymphocyte subtypes can be used in routine work on BD FACS Canto II instrument for quality assessment of fresh cell products collected by leukapheresis procedure.


Subject(s)
Flow Cytometry , Humans , Flow Cytometry/standards , Flow Cytometry/methods , CD3 Complex , CD8-Positive T-Lymphocytes/immunology , CD8-Positive T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/immunology , T-Lymphocyte Subsets/immunology , Quality Control , Leukapheresis/methods , Reproducibility of Results , Immunotherapy, Adoptive/methods
5.
Bioanalysis ; 16(11): 505-517, 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38864397

ABSTRACT

The 16th GCC Closed Forum was held in Orlando, FL, USA, on 23 June 2023. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: IS response, flow cytometry, changes to the bioanalytical industry, NGS assays, biomarker assay for tissues, dPCR validation, immunogenicity harmonization and ICH M10 implementation. Conclusions and consensus from discussions of these topics are included in this article.


Subject(s)
Biomarkers , Flow Cytometry , Flow Cytometry/standards , Flow Cytometry/methods , Biomarkers/analysis , Humans , High-Throughput Nucleotide Sequencing , Real-Time Polymerase Chain Reaction/methods
6.
World J Microbiol Biotechnol ; 40(7): 222, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38811387

ABSTRACT

In this study, it was aimed to investigate bacterial contamination in apheresis platelet suspensions (APS) by automated blood culture system and flow cytometry method (FCM).33 spiked APS each using 11 bacterial strains (5 standard strains, 6 clinical isolates), were prepared in three different dilutions (1-10, 10-50, 50-100 cfu/mL), incubated in two different temperatures (35-37 °C and 22-24 °C) and different incubation times (18-96 h) evaluated by FCM. This three different dilutions were also inoculated into special platelet culture bottles (BacT/ALERT® BPA) and loaded into the blood culture system. Additionally 80 APSs routinely prepared in the Transfusion Center were evaluated by both FCM and the blood culture system. Platelets were lysed by freeze-thaw method.All spiked samples were positive with BacT/ALERT® BPA in 12-18 h. In 96 h incubation at 22-24 °C, the presence of bacteria was detected by FCM in all other samples (31/33) except low dilutions (1-10 and 10-100 CFU/ml) of K.pneumoniae standard strain. In the 35-37 °C, the presence of bacteria was detected by FCM in all samples (33/33) after 48 h of incubation. In routine APS one sample detected as positive (Bacillus simplex) with BacT/ALERT® BPA and no positivity was detected by FCM.The freeze-thaw method, which we have optimized for the lysis of platelets, is very practical and can be easily applied. The BacT/ALERT® system has been found to be very sensitive in detecting bacterial contamination in PSs. Flow cytometry method has been found to be successful, fast, easy to use and low cost in detecting bacterial contamination in PSs.


Subject(s)
Blood Platelets , Blood Safety , Flow Cytometry , Blood Safety/instrumentation , Blood Safety/methods , Blood Platelets/microbiology , Flow Cytometry/standards , Blood Component Removal , Blood Culture/standards , Bacteria/isolation & purification , Humans , Sensitivity and Specificity
7.
Cytometry B Clin Cytom ; 106(3): 192-202, 2024 05.
Article in English | MEDLINE | ID: mdl-38700195

ABSTRACT

The assessment of T-cell clonality by flow cytometry has long been suboptimal, relying on aberrant marker expression and/or intensity. The introduction of TRBC1 shows much promise for improving the diagnosis of T-cell neoplasms in the clinical flow laboratory. Most laboratories considering this marker already have existing panels designed for T-cell workups and will be determining how best to incorporate TRBC1. We present this comprehensive summary of TRBC1 and supplemental case examples to familiarize the flow cytometry community with its potential for routine application, provide examples of how to incorporate it into T-cell panels, and signal caution in interpreting the results in certain diagnostic scenarios where appropriate.


Subject(s)
Flow Cytometry , T-Lymphocytes , Flow Cytometry/methods , Flow Cytometry/standards , Humans , T-Lymphocytes/immunology , Immunophenotyping/methods , Biomarkers, Tumor/immunology , Biomarkers, Tumor/genetics
8.
Methods Cell Biol ; 186: 107-130, 2024.
Article in English | MEDLINE | ID: mdl-38705596

ABSTRACT

Mass cytometry permits the high dimensional analysis of cellular systems at single-cell resolution with high throughput in various areas of biomedical research. Here, we provide a state-of-the-art protocol for the analysis of human peripheral blood mononuclear cells (PBMC) by mass cytometry. We focus on the implementation of measures promoting the harmonization of large and complex studies to aid robustness and reproducibility of immune phenotyping data.


Subject(s)
Flow Cytometry , Leukocytes, Mononuclear , Humans , Leukocytes, Mononuclear/cytology , Leukocytes, Mononuclear/immunology , Flow Cytometry/methods , Flow Cytometry/standards , Immunophenotyping/methods , Single-Cell Analysis/methods
9.
Biomolecules ; 14(5)2024 May 15.
Article in English | MEDLINE | ID: mdl-38785994

ABSTRACT

BACKGROUND: Fluorescent proteins (FPs) are pivotal reagents for flow cytometry analysis or fluorescent microscopy. A new generation of immunoreagents (fluobodies/chromobodies) has been developed by fusing recombinant nanobodies to FPs. METHODS: We analyzed the quality of such biomolecules by a combination of gel filtration and SDS-PAGE to identify artefacts due to aggregation or material degradation. RESULTS: In the SDS-PAGE run, unexpected bands corresponding to separate fluobodies were evidenced and characterized as either degradation products or artefacts that systematically resulted in the presence of specific FPs and some experimental conditions. The elimination of N-terminal methionine from FPs did not impair the appearance of FP fragments, whereas the stability and migration characteristics of some FP constructs were strongly affected by heating in loading buffer, which is a step samples undergo before electrophoretic separation. CONCLUSIONS: In this work, we provide explanations for some odd results observed during the quality control of fluobodies and summarize practical suggestions for the choice of the most convenient FPs to fuse to antibody fragments.


Subject(s)
Electrophoresis, Polyacrylamide Gel , Electrophoresis, Polyacrylamide Gel/methods , Single-Domain Antibodies/chemistry , Humans , Chromatography, Gel , Flow Cytometry/standards , Flow Cytometry/methods , Quality Control
10.
Clin Chem Lab Med ; 62(10): 2011-2023, 2024 Sep 25.
Article in English | MEDLINE | ID: mdl-38584471

ABSTRACT

OBJECTIVES: Given that method validation is mandatory for compliance with the International Organization for Standardization (ISO) 15,189 standard requirements, we evaluated the analytical performance of the AQUIOS CL system (Beckman Coulter) and compared it with two bead-based flow cytometry (FCM) protocols (BD FACSCAntoTM-II and Beckman Coulter DxFLEX). There are no comparative literature data on standardized protocols for counting lymphocyte subsets on the new-generation cytometer DxFLEX. METHODS: We evaluated the AQUIOS CL's performance with regard to accuracy, linearity and stability by using dedicated control cell samples and patient samples. We also compared the lymphocyte counts measured on the AQUIOS CL (n=69 samples) with those measured on the BD FACSCAntoTM-II and DxFLEX FCM systems. For 61 samples, FCM results were compared with those measured on the XN-3000 Sysmex hematology analyzer. RESULTS: AQUIOS CL showed acceptable performance - even outside the manufacturer's quantification ranges- and strong correlations with bead-based FCM methods. The FCM techniques and the XN-3000 gave similar absolute lymphocyte counts, although values in samples with intense lymphocytosis (B cell lymphoma/leukemia) were underestimated. CONCLUSIONS: The AQUIOS CL flow cytometer is a time-saving, single-platform system with good performance, especially when the manufacturer's instructions for use are followed. However, AQUIOS CL's possible limitations and pitfalls impose validation of a bead-based FCM method for immunophenotyping verification or as a back-up system. Although the DxFLEX flow cytometer is more time-consuming to use, it can provide standardized lymphocyte subset counts in case of aberrant results on AQUIOS CL or in the event of equipment failure.


Subject(s)
Flow Cytometry , Flow Cytometry/methods , Flow Cytometry/instrumentation , Flow Cytometry/standards , Humans , Lymphocyte Count/instrumentation , Lymphocyte Count/standards , Lymphocyte Count/methods
11.
Cytometry B Clin Cytom ; 106(3): 203-215, 2024 05.
Article in English | MEDLINE | ID: mdl-38656036

ABSTRACT

The monocyte subset partitioning by flow cytometry, known as "monocyte assay," is now integrated into the new classifications as a supporting criterion for CMML diagnosis, if a relative accumulation of classical monocytes above 94% of total circulating monocytes is observed. Here we provide clinical flow cytometry laboratories with technical support adapted for the most commonly used cytometers. Step-by-step explanations of the gating strategy developed on whole peripheral blood are presented while underlining the most common difficulties. In a second part, interpretation recommendations of circulating monocyte partitioning from the dedicated French working group "CytHem-LMMC" are shared as well as the main pitfalls, including false positive and false negative cases. The particular flow-defined inflammatory profile is described and the usefulness of the nonclassical monocyte specific marker, namely slan, highlighted. Examples of reporting to the physician with frequent situations encountered when using the monocyte assay are also presented.


Subject(s)
Flow Cytometry , Monocytes , Flow Cytometry/methods , Flow Cytometry/standards , Humans , Monocytes/cytology , Monocytes/immunology , Immunophenotyping/methods , Immunophenotyping/standards
13.
Cytometry B Clin Cytom ; 106(4): 228-238, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38407537

ABSTRACT

Flow cytometry is a key clinical tool in the diagnosis of many hematologic malignancies and traditionally requires close inspection of digital data by hematopathologists with expert domain knowledge. Advances in artificial intelligence (AI) are transferable to flow cytometry and have the potential to improve efficiency and prioritization of cases, reduce errors, and highlight fundamental, previously unrecognized associations with underlying biological processes. As a multidisciplinary group of stakeholders, we review a range of critical considerations for appropriately applying AI to clinical flow cytometry, including use case identification, low and high risk use cases, validation, revalidation, computational considerations, and the present regulatory frameworks surrounding AI in clinical medicine. In particular, we provide practical guidance for the development, implementation, and suggestions for potential regulation of AI-based methods in the clinical flow cytometry laboratory. We expect these recommendations to be a helpful initial framework of reference, which will also require additional updates as the field matures.


Subject(s)
Artificial Intelligence , Flow Cytometry , Flow Cytometry/methods , Flow Cytometry/standards , Humans , Hematologic Neoplasms/diagnosis , Hematologic Neoplasms/pathology
14.
Clin Chem Lab Med ; 62(7): 1411-1420, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38217085

ABSTRACT

OBJECTIVES: Lymphocyte subsets are the predictors of disease diagnosis, treatment, and prognosis. Determination of lymphocyte subsets is usually carried out by flow cytometry. Despite recent advances in flow cytometry analysis, most flow cytometry data can be challenging with manual gating, which is labor-intensive, time-consuming, and error-prone. This study aimed to develop an automated method to identify lymphocyte subsets. METHODS: We propose a knowledge-driven combined with data-driven method which can gate automatically to achieve subset identification. To improve accuracy and stability, we have implemented a Loop Adjustment Gating to optimize the gating result of the lymphocyte population. Furthermore, we have incorporated an anomaly detection mechanism to issue warnings for samples that might not have been successfully analyzed, ensuring the quality of the results. RESULTS: The evaluation showed a 99.2 % correlation between our method results and manual analysis with a dataset of 2,000 individual cases from lymphocyte subset assays. Our proposed method attained 97.7 % accuracy for all cases and 100 % for the high-confidence cases. With our automated method, 99.1 % of manual labor can be saved when reviewing only the low-confidence cases, while the average turnaround time required is only 29 s, reducing by 83.7 %. CONCLUSIONS: Our proposed method can achieve high accuracy in flow cytometry data from lymphocyte subset assays. Additionally, it can save manual labor and reduce the turnaround time, making it have the potential for application in the laboratory.


Subject(s)
Flow Cytometry , Lymphocyte Subsets , Lymphocyte Subsets/classification , Lymphocyte Subsets/cytology , Flow Cytometry/methods , Flow Cytometry/standards , Automation, Laboratory , Reproducibility of Results , Humans
15.
Int J Lab Hematol ; 46(3): 488-494, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38114449

ABSTRACT

INTRODUCTION: Lymphocyte subset enumeration by flow cytometry is important for the therapeutic monitoring of a range of conditions. However, current bead-based methodologies do not produce metrologically traceable results. Here we compare an established bead-based methodology with a volumetric-based system traceable to an internationally recognised reference method. METHOD: A total of 118 samples received for lymphocyte subset analysis were tested using an established bead-based technique (BD Multitest™ 6-colour TBNK assay using Trucount™ tubes on a BD FACSLyric flow cytometer), followed by a volumetric method on the Sysmex XF-1600 flow cytometer using Exbio Kombitest 6-colour TBNK reagent. All samples were tested in accordance with the manufacturer's instructions. RESULTS: Absolute count values from both methodologies for CD3+, CD3 + CD4+, CD3 + CD8+, CD19+ and CD3-CD16+/CD56+ lymphocyte populations were compared using linear regression (R2 for all parameters >0.95) and Bland-Altman analysis. There was no significant bias (where p < 0.05) for absolute CD3 + CD4+ lymphocytes in the defined therapeutic range of 0-250 cells/µL (mean bias: 0.27 cells/µL). Although positive biases were seen for CD3 + CD4+ lymphocytes (over the entire range tested: 14-1798 cells/µL) and CD3-CD16+/CD56+ lymphocytes (mean bias: 10.83 cells/µL and 6.79 cells/µL, respectively). Negative biases were seen for CD3 + CD8+ and CD19+ lymphocytes (mean bias: -29.17 cells/µL and - 18.76 cells/µL, respectively). CONCLUSION: A high degree of correlation was found for results from both methodologies and observed bias was within the limits of clinical acceptability for all populations. This shows that the metrologically traceable lymphocyte subset absolute counts produced by the Sysmex XF-1600 are robust within clinically required limits.


Subject(s)
Flow Cytometry , Lymphocyte Subsets , Flow Cytometry/methods , Flow Cytometry/standards , Humans , Lymphocyte Count/standards , Lymphocyte Count/methods , Antigens, CD/analysis , Immunophenotyping/standards , Immunophenotyping/methods , Female
16.
Cells ; 12(6)2023 03 09.
Article in English | MEDLINE | ID: mdl-36980191

ABSTRACT

Mesenchymal stromal cells (MSCs) have the potential to suppress pathological activation of immune cells and have therefore been considered for the treatment of Graft-versus-Host-Disease. The clinical application of MSCs requires a process validation to ensure consistent quality. A flow cytometry-based mixed lymphocyte reaction (MLR) was developed to analyse the inhibitory effect of MSCs on T cell proliferation. Monoclonal antibodies were used to stimulate T cell expansion and determine the effect of MSCs after four days of co-culture based on proliferation tracking with the violet proliferation dye VPD450. Following the guidelines of the International Council for Harmonisation (ICH) Q2 (R1), the performance of n = 30 peripheral blood mononuclear cell (PBMC) donor pairs was assessed. The specific inhibition of T cells by viable MSCs was determined and precision values of <10% variation for repeatability and <15% for intermediate precision were found. Compared to a non-compendial reference method, a linear correlation of r = 0.9021 was shown. Serial dilution experiments demonstrated a linear range for PBMC:MSC ratios from 1:1 to 1:0.01. The assay was unaffected by PBMC inter-donor variability. In conclusion, the presented MLR can be used as part of quality control tests for the validation of MSCs as a clinical product.


Subject(s)
Flow Cytometry , Graft vs Host Disease , Lymphocyte Culture Test, Mixed , Mesenchymal Stem Cells , Lymphocyte Culture Test, Mixed/methods , Humans , Mesenchymal Stem Cells/cytology , Leukocytes, Mononuclear/cytology , Quality Control , Flow Cytometry/methods , Flow Cytometry/standards , T-Lymphocytes/cytology , Cell Proliferation , Graft vs Host Disease/therapy
17.
Front Immunol ; 13: 759188, 2022.
Article in English | MEDLINE | ID: mdl-35126389

ABSTRACT

Intracellular cytokine staining (ICS) is a widely employed ex vivo method for quantitative determination of the activation status of immune cells, most often applied to T cells. ICS test samples are commonly prepared from animal or human tissues as unpurified cell mixtures, and cell-specific cytokine signals are subsequently discriminated by gating strategies using flow cytometry. Here, we show that when ICS samples contain Ly6G+ neutrophils, neutrophils are ex vivo activated by an ICS reagent - phorbol myristate acetate (PMA) - which leads to hydrogen peroxide (H2O2) release and death of cytokine-expressing T cells. This artifact is likely to result in overinterpretation of the degree of T cell suppression, misleading immunological research related to cancer, infection, and inflammation. We accordingly devised easily implementable improvements to the ICS method and propose alternative methods for assessing or confirming cellular cytokine expression.


Subject(s)
Biomarkers , Cytokines/metabolism , Lymphocyte Activation , T-Lymphocytes/immunology , T-Lymphocytes/metabolism , Animals , Artifacts , Breast Neoplasms , Cell Line , Disease Models, Animal , Female , Flow Cytometry/methods , Flow Cytometry/standards , Humans , Hydrogen Peroxide/metabolism , Intracellular Space , Leukocyte Count , Lymphocyte Activation/genetics , Lymphocyte Activation/immunology , Mice , Mice, Knockout , Models, Biological , Neutrophils/metabolism , Neutrophils/pathology
18.
Int J Mol Sci ; 23(2)2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35055086

ABSTRACT

Chimeric-antigen-receptor (CAR)-T-cell therapy is already widely used to treat patients who are relapsed or refractory to chemotherapy, antibodies, or stem-cell transplantation. Multiple myeloma still constitutes an incurable disease. CAR-T-cell therapy that targets BCMA (B-cell maturation antigen) is currently revolutionizing the treatment of those patients. To monitor and improve treatment outcomes, methods to detect CAR-T cells in human peripheral blood are highly desirable. In this study, three different detection reagents for staining BCMA-CAR-T cells by flow cytometry were compared. Moreover, a quantitative polymerase chain reaction (qPCR) to detect BCMA-CAR-T cells was established. By applying a cell-titration experiment of BCMA-CAR-T cells, both methods were compared head-to-head. In flow-cytometric analysis, the detection reagents used in this study could all detect BCMA-CAR-T cells at a similar level. The results of false-positive background staining differed as follows (standard deviation): the BCMA-detection reagent used on the control revealed a background staining of 0.04% (±0.02%), for the PE-labeled human BCMA peptide it was 0.25% (±0.06%) and for the polyclonal anti-human IgG antibody it was 7.2% (±9.2%). The ability to detect BCMA-CAR-T cells down to a concentration of 0.4% was similar for qPCR and flow cytometry. The qPCR could detect even lower concentrations (0.02-0.01%). In summary, BCMA-CAR-T-cell monitoring can be reliably performed by both flow cytometry and qPCR. In flow cytometry, reagents with low background staining should be preferred.


Subject(s)
B-Cell Maturation Antigen/metabolism , Flow Cytometry , Polymerase Chain Reaction , Receptors, Chimeric Antigen/metabolism , T-Lymphocytes/metabolism , B-Cell Maturation Antigen/genetics , Biomarkers , Flow Cytometry/methods , Flow Cytometry/standards , Humans , Immunophenotyping , Immunotherapy, Adoptive/methods , Immunotherapy, Adoptive/standards , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Real-Time Polymerase Chain Reaction , Receptors, Chimeric Antigen/genetics , Reproducibility of Results , Sensitivity and Specificity , T-Lymphocytes/immunology
19.
Int J Lab Hematol ; 44(1): 82-87, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34409726

ABSTRACT

INTRODUCTION: Stem cell enumeration by the hematopoietic progenitor cells (HPC) mode is a novel method available from Sysmex XN2000 hematology analyzer. A small amount of blood (190 µL) is required, and the results are available in a few minutes without manual gating or presample treatment. The present study compares stem cell measurements using XN2000 analyzer HPC mode and FC500 flow cytometry analyzer using peripheral blood (PB) specimens and apheresis products. METHODS: In this prospective study, CD34-positive cell counts were enumerated using an FC500 flow cytometry analyzer and compared with XN2000 Sysmex analyzer (XN-HPC mode) in the same samples. Results were compared using Bland-Altman plots. RESULTS: A total of 103 samples were used. In the PB samples, the median HPC count and CD34-positive cells were 83.5 × 106 /L and 78.0 × 106 /L, respectively. The mean Bland-Altman difference was 4.5 × 106 /L (Limits: -51.7 to 60.7 × 106 /L), with a Pearson's correlation of 0.79. In the apheresis products, the median HPC count and CD34-positive cells were 1468 × 106 /L (IQR: 1049 - 1960 × 106 /L) and 1327 × 106 /L (IQR: 910 - 2001 × 106 /L), respectively. The mean Bland-Altman difference was 179.0 × 106 /L (Limits: -2022.2 - 2380.2 × 106 /L), with a Pearson's correlation of 0.58. CONCLUSION: The XN-HPC mode has an excellent correlation and minimal disagreement for stem cell enumeration in PB compared with flow cytometry and could replace it. There is high disagreement in apheresis products, and therefore, the XN-HPC mode cannot be recommended.


Subject(s)
Biomarkers , Flow Cytometry/instrumentation , Flow Cytometry/methods , Hematopoietic Stem Cells/metabolism , Antigens, CD34/metabolism , Blood Cells/cytology , Blood Cells/metabolism , Blood Component Removal/methods , Bone Marrow Cells/cytology , Bone Marrow Cells/metabolism , Flow Cytometry/standards , Hematology/instrumentation , Hematology/methods , Hematopoietic Stem Cell Transplantation , Hematopoietic Stem Cells/cytology , Humans , Immunophenotyping/instrumentation , Immunophenotyping/methods , Reproducibility of Results , Sensitivity and Specificity , Tissue Donors
20.
Int J Lab Hematol ; 44(1): 118-126, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34585519

ABSTRACT

INTRODUCTION: Monitoring patients with acute myeloid leukemia can be implemented through various techniques such as multiparameter flow cytometry, real-time quantitative polymerase chain reaction, and next-generation sequencing. However, there is scarce studies when comparing the data of next-generation sequencing and flow cytometry for monitoring disease progression, particularly how they might supplement one another when used in tandem. METHODS: We investigated 107 patients via retrospective analysis using follow-up MFC and NGS data with a total of 717 MFC and 247 NGS studies to compare these methods in monitoring minimal/measurable residual disease. RESULTS: 197 instances were MFC+ /NGS+ , 3 were MFC- /NGS- , 44 were MFC- /NGS+ , and 3 are MFC+ /NGS- . The majority of the MFC- /NGS+ cases occurred within 6 months during the post-treatment phase (64%). Among 44 MFC- /NGS+ instances, 13 had similar NGS profiles to their original day 0 diagnosis. The remaining cases showed preleukemic clonal hematopoiesis mutations, "likely pathogenic mutations," or "variants of uncertain significance." CONCLUSION: Our findings show that flow cytometry has its advantages with comparable sensitivity in detecting minimal/measurable residual disease. Next-generation sequencing could be used in an increased and more regular capacity in conjunction with flow cytometry to achieve a more comprehensive surveillance of these patients, resulting in improved outcomes.


Subject(s)
Flow Cytometry/methods , Flow Cytometry/standards , High-Throughput Nucleotide Sequencing/methods , High-Throughput Nucleotide Sequencing/standards , Leukemia, Myeloid, Acute/diagnosis , Neoplasm, Residual/diagnosis , Biomarkers, Tumor , Disease Management , Humans , Immunophenotyping , Leukemia, Myeloid, Acute/etiology , Leukemia, Myeloid, Acute/metabolism , Mutation , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS