Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.794
Filter
1.
J Vis ; 24(7): 3, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38967946

ABSTRACT

It was recently established that the axial power, the refractive power required by the eye for a sharp retinal image in an eye of a certain axial length, and the total refractive power of the eye may both be described by a bi-exponential function as a function of age (Rozema, 2023). Inspired by this result, this work explores whether these bi-exponential functions are able to simulate the various known courses of refractive development described in the literature, such as instant emmetropization, persistent hypermetropia, developing hypermetropia, myopia, instant homeostasis, modulated development, or emmetropizing hypermetropes. Moreover, the equations can be adjusted to match the refractive development of school-age myopia and pseudophakia up to the age of 20 years. All of these courses closely resemble those reported in the previous literature while simultaneously providing estimates for the underlying changes in axial and whole eye power.


Subject(s)
Emmetropia , Hyperopia , Myopia , Refraction, Ocular , Humans , Refraction, Ocular/physiology , Myopia/physiopathology , Child , Adolescent , Hyperopia/physiopathology , Young Adult , Emmetropia/physiology , Child, Preschool , Axial Length, Eye , Pseudophakia/physiopathology , Adult , Eye/growth & development , Aging/physiology , Refractive Errors/physiopathology
2.
Digit J Ophthalmol ; 30(2): 27-32, 2024.
Article in English | MEDLINE | ID: mdl-38962666

ABSTRACT

We present the case of a 65-year-old man with bilateral keratoconus and history of bilateral penetrating keratoplasty (PK) who developed gradual visual decline in the left eye due to cataract formation. Following successful left eye cataract surgery and monofocal, non-toric intraocular lens (IOL) in-the-bag implantation, the patient experienced persistently low uncorrected distance visual acuity (UDVA) due to high residual refractive error and intolerance to contact lenses. A supplementary toric IOL was placed in the ciliary sulcus, but subsequent rotational instability of the lens required repeated realignment. Despite two attempts at IOL repositioning, the rotational instability persisted, necessitating the replacement of the original Sulcoflex IOL with a toric, implantable Collamer lens. Following the implantation of the toric ICL, the patient achieved excellent UDVA with no adverse events over a 4-year follow-up period. This case highlights the potential rotational instability associated with toric piggyback IOLs in keratoconic, post-PK, pseudophakic eyes and the special considerations on choosing the type of piggyback lens in these eyes.


Subject(s)
Keratoplasty, Penetrating , Lens Implantation, Intraocular , Lenses, Intraocular , Prosthesis Design , Pseudophakia , Visual Acuity , Humans , Male , Aged , Pseudophakia/surgery , Pseudophakia/physiopathology , Keratoplasty, Penetrating/adverse effects , Keratoplasty, Penetrating/methods , Lens Implantation, Intraocular/methods , Keratoconus/surgery , Keratoconus/diagnosis , Refraction, Ocular/physiology , Postoperative Complications/surgery , Postoperative Complications/etiology , Reoperation , Rotation
3.
BMC Ophthalmol ; 24(1): 269, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38918765

ABSTRACT

BACKGROUND: To evaluate the optical performance and safety of a new multifocal lens with a novel optical design featuring two additional foci (or intensifiers) in patients with cataract and presbyopia. METHODS: In this single-center, non-randomized prospective observational study, 31 patients underwent implantation of the new multifocal IOL between March 2020 and November 2021 at a tertiary clinical center in Buenos Aires and Ramos Mejia, Argentina. Postoperative examinations with emphasis on uncorrected and corrected visual acuity at distance and near and at two different intermediate distances (80 cm and 60 cm) were performed during the 3 postoperative months. RESULTS: Of the 31 patients who underwent implantation of the new IOL, 30 underwent bilateral surgery (61 eyes in total). At 3 months, all 61 eyes had an uncorrected distance visual acuity (UCDVA) of at least 0.15 logMAR; 57 eyes (93%) had an uncorrected distance visual acuity (UCDVA) of 0.1 logMAR and 27 eyes (44%) had an UCDVA of 0.0 logMAR. At 80 cm, 60 eyes (98%) had an uncorrected intermediate visual acuity (UCIVA) of at least 0.1 log MAR and 48 eyes (79%) had an UCIVA of 0.0 logMAR. CONCLUSION: The new multifocal IOL with a novel optical concept (5 foci) showed a wide range of visual acuity especially at intermediate and near distances in patients undergoing cataract surgery. Uncorrected visual acuity was excellent at all tested distances, monocularly and binocularly, spectacle independence and patient satisfaction were high.


Subject(s)
Multifocal Intraocular Lenses , Presbyopia , Prosthesis Design , Visual Acuity , Humans , Visual Acuity/physiology , Prospective Studies , Female , Male , Aged , Middle Aged , Presbyopia/physiopathology , Presbyopia/surgery , Refraction, Ocular/physiology , Lens Implantation, Intraocular , Pseudophakia/physiopathology , Phacoemulsification , Cataract/complications , Cataract/physiopathology , Lenses, Intraocular , Aged, 80 and over , Follow-Up Studies
4.
J Refract Surg ; 40(6): e407-e419, 2024 May.
Article in English | MEDLINE | ID: mdl-38848051

ABSTRACT

PURPOSE: To assess clinical outcomes after cataract surgery with bilateral implantation of a new bi-aspheric diffractive intraocular lens (IOL). METHODS: Thirty patients underwent bilateral implantation of the Asqelio Trifocal Toric IOL (AST Products, Inc) and were evaluated 3 months postoperatively. Main outcomes included refractive error, photopic monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CDIVA) at 60 cm, and near (UNVA, CDNVA) at 40 cm visual acuities. Mesopic monocular and binocular CDNVA were also measured. Defocus curves, binocular contrast sensitivity under photopic and mesopic conditions with and without glare and rotational stability were determined. Patients completed Catquest-9SF and visual symptoms questionnaires. RESULTS: Average values of binocular photopic CDVA, CDIVA, and CDNVA, and mesopic CDNVA were -0.04 ± 0.06, 0.02 ± 0.08, 0.02 ± 0.07, and 0.22 ± 0.11 logMAR, respectively. All patients achieved cumulative CDVA ⩾ 20/25, and CDIVA and CDNVA of 20/32 or better. Binocular depth of focus was approximately 3.25 diopters (D). Mean postoperative spherical equivalent was -0.08 ± 0.26 D, with 95% of eyes within ±0.50 D. Mean postoperative refractive cylinder was -0.22 ± 0.27 D, with 91.67% of eyes within 0.50 D or less, respectively. IOL rotation averaged 0.25 ± 0.65 degrees, all eyes having rotation of less than 5 degrees. Contrast sensitivity was within or above normal levels under photopic and mesopic conditions, with or without glare, except for 12 cpd under mesopic conditions with glare. Questionnaire responses indicated 96.67% of patients were satisfied or very satisfied with postoperative vision, and 80.00% to 96.67% reported no difficulty in different daily activities. CONCLUSIONS: The Asqelio Trifocal Toric IOL demonstrated favorable outcomes, providing excellent visual performance at all distances, precise refractive results, and remarkable rotational stability. Patients reported high satisfaction levels and minimal difficulty in daily activities. [J Refract Surg. 2024;40(6):e407-e419.].


Subject(s)
Contrast Sensitivity , Lens Implantation, Intraocular , Multifocal Intraocular Lenses , Patient Satisfaction , Phacoemulsification , Prosthesis Design , Pseudophakia , Refraction, Ocular , Vision, Binocular , Visual Acuity , Humans , Visual Acuity/physiology , Vision, Binocular/physiology , Male , Female , Aged , Refraction, Ocular/physiology , Pseudophakia/physiopathology , Middle Aged , Contrast Sensitivity/physiology , Surveys and Questionnaires , Prospective Studies , Aged, 80 and over , Lenses, Intraocular , Treatment Outcome
5.
J Refract Surg ; 40(6): e398-e406, 2024 May.
Article in English | MEDLINE | ID: mdl-38848057

ABSTRACT

PURPOSE: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery. METHODS: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire. RESULTS: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers. CONCLUSIONS: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].


Subject(s)
Contrast Sensitivity , Corneal Wavefront Aberration , Depth Perception , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification , Prosthesis Design , Pseudophakia , Refraction, Ocular , Vision, Binocular , Visual Acuity , Humans , Visual Acuity/physiology , Female , Male , Middle Aged , Aged , Contrast Sensitivity/physiology , Pseudophakia/physiopathology , Refraction, Ocular/physiology , Corneal Wavefront Aberration/physiopathology , Depth Perception/physiology , Vision, Binocular/physiology , Surveys and Questionnaires , Prospective Studies , Patient Satisfaction , Aged, 80 and over , Treatment Outcome
6.
Int Ophthalmol ; 44(1): 285, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38935310

ABSTRACT

BACKGROUND: To evaluate the agreement between the Goldman applanation tonometer (GAT), Tono-Pen, and noncontact tonometer (NCT) in the measurement of intraocular pressure (IOP) in pseudophakic children. METHODS: The medical records of nonglaucomatous pseudophakic children between 2009 and 2019 were retrospectively analyzed. A total of 46 eyes of 23 patients operated for bilateral pediatric cataract were included in the study. The patients' mean age was 13.4 ± 4.1 years. Central corneal thickness (CCT) and IOP values measured with the GAT, Tono-Pen, and NCT were recorded. Agreement between the tonometers was evaluated by intraclass correlation coefficients (ICC) and the Bland-Altman method. RESULTS: The mean IOP of the 46 eyes included in the study was measured as 13.7 ± 2.3 mm Hg with the GAT, 16.0 ± 2.3 mm Hg with NCT, and 16.5 ± 2.3 mm Hg with the Tono-Pen (p < 0.001). There is no statistical difference between NCT and Tono-Pen measurements, while GAT measurements were significantly lower than those of the NCT and Tono-pen. ICC values showed fair agreement between NCT and Tono-Pen (ICC = 0.720), whereas there was poor agreement between GAT and NCT (ICC = 0.501) and Tono-pen (ICC = 0.314). CONCLUSIONS: With all devices included in the study, thicker corneas were associated with higher IOP measurements. Although there was moderate agreement between the NCT and Tono-Pen, there was a statistically significant difference in the IOP values provided by the three devices. Our results suggest these devices should not be used interchangeably.


Subject(s)
Intraocular Pressure , Pseudophakia , Tonometry, Ocular , Humans , Intraocular Pressure/physiology , Tonometry, Ocular/instrumentation , Female , Male , Retrospective Studies , Child , Pseudophakia/physiopathology , Pseudophakia/diagnosis , Adolescent , Reproducibility of Results , Child, Preschool , Cornea/pathology
7.
Eye (Lond) ; 38(Suppl 1): 15-20, 2024 May.
Article in English | MEDLINE | ID: mdl-38580742

ABSTRACT

PURPOSE: To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. METHODS: Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes. RESULTS: In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups. CONCLUSIONS: The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Prosthesis Design , Visual Acuity , Humans , Visual Acuity/physiology , Prospective Studies , Female , Male , Middle Aged , Aged , Depth Perception/physiology , Pseudophakia/physiopathology , Refractive Errors/physiopathology , Phacoemulsification , Patient Satisfaction , Computer Simulation , Refraction, Ocular/physiology , Astigmatism/physiopathology , Vision, Binocular/physiology
8.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38651698

ABSTRACT

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Sclera , Tomography, Optical Coherence , Visual Acuity , Humans , Sclera/surgery , Lens Implantation, Intraocular/methods , Prospective Studies , Visual Acuity/physiology , Female , Male , Middle Aged , Aged , Aphakia, Postcataract/surgery , Aphakia, Postcataract/physiopathology , Surgical Flaps , Suture Techniques , Pseudophakia/physiopathology , Refraction, Ocular/physiology
9.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658894

ABSTRACT

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Subject(s)
Laser Therapy , Multifocal Intraocular Lenses , Phacoemulsification , Refraction, Ocular , Visual Acuity , Humans , Retrospective Studies , Male , Female , Phacoemulsification/methods , Visual Acuity/physiology , Middle Aged , Laser Therapy/methods , Aged , Refraction, Ocular/physiology , Lens Implantation, Intraocular/methods , Pseudophakia/physiopathology , Treatment Outcome , Prosthesis Design , Cataract Extraction/methods , Follow-Up Studies
10.
Eye (Lond) ; 38(Suppl 1): 9-14, 2024 May.
Article in English | MEDLINE | ID: mdl-38580741

ABSTRACT

BACKGROUND/OBJECTIVE: To evaluate the visual performance of a purely refractive extended depth of focus (EDF) intraocular lens (IOL). SUBJECTS/METHODS: A prospective, multi-center, randomized, subject/evaluator-masked study. Subjects were bilaterally implanted with the EDF test (Model ZEN00V, N = 60) or an enhanced monofocal control (Model ICB00, N = 57) IOL. Monocular corrected distance (CDVA), intermediate (DCIVA), near acuities (DCNVA) and patient reported visual symptoms were evaluated at the 6-month visit. Monocular mesopic contrast sensitivity (CS) and depth of focus (DOF) testing were assessed at 3 months. RESULTS: CDVA (Mean ± SD) was -0.06 ± 0.08 for test and -0.05 ± 0.08 logMAR for control groups. DCIVA was 0.13 ± 0.08 for test and 0.18 ± 0.14 logMAR for control groups (p = 0.0127). DCNVA was 0.37 ± 0.10 for test and 0.43 ± 0.16 logMAR for control groups (p = 0.0137). Test lens was statistically superior for intermediate and near. Overall, 91.7% (halos), 95.0% (starbursts) and 95.0% (glare) of test lens patients reported that they did not experience, were not bothered, or were slightly bothered by specific visual symptoms, compared to 98.2%, 100% and 96.5% in the control group. The DOF range over which monocular visual acuity was 0.20 logMAR or better was -1.6 D for the test lens. Mesopic CS was comparable between both groups, falling within 0.11 log units for all measured cycles per degree with and without glare. CONCLUSION: The EDF IOL demonstrated extended range of vision and statistically superior intermediate and near performance compared to the monofocal IOL. Distance visual acuity, contrast sensitivity and dysphotopsia profile were similar to the monofocal IOL.


Subject(s)
Contrast Sensitivity , Depth Perception , Lens Implantation, Intraocular , Lenses, Intraocular , Pseudophakia , Visual Acuity , Humans , Prospective Studies , Visual Acuity/physiology , Female , Male , Contrast Sensitivity/physiology , Aged , Middle Aged , Depth Perception/physiology , Pseudophakia/physiopathology , Prosthesis Design , Refraction, Ocular/physiology , Phacoemulsification , Double-Blind Method , Patient Satisfaction
11.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38671381

ABSTRACT

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Subject(s)
Lenses, Intraocular , Visual Acuity , Humans , Prospective Studies , Visual Acuity/physiology , Female , Male , Aged , Middle Aged , Phacoemulsification , Refraction, Ocular/physiology , Lens Implantation, Intraocular , Prosthesis Design , Postoperative Period , Pseudophakia/physiopathology , Optics and Photonics
12.
BMC Ophthalmol ; 24(1): 183, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38649861

ABSTRACT

AIM: To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction. METHODS: This retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence. RESULTS: Overall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence. CONCLUSIONS: Implantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Myopia , Refraction, Ocular , Visual Acuity , Humans , Female , Male , Retrospective Studies , Visual Acuity/physiology , Refraction, Ocular/physiology , Middle Aged , Myopia/physiopathology , Myopia/surgery , Aged , Prosthesis Design , Adult , Contrast Sensitivity/physiology , Phacoemulsification , Pseudophakia/physiopathology , Axial Length, Eye , Depth Perception/physiology , Follow-Up Studies
13.
Indian J Ophthalmol ; 72(7): 1001-1006, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38622856

ABSTRACT

PURPOSE: To assess the safety and efficacy of intravitreal Aflibercept (IVA) versus dexamethasone (DEX) implant for treating recalcitrant diabetic macular edema (DME) in pseudophakic eyes at 1-year follow-up. DESIGN: Retrospective comparative case series. PARTICIPANTS: Data of all patients diagnosed with DME between January 2019 and December 2021, who underwent 4-monthly doses of intravitreal ranibizumab but had persistent DME [central macular thickness (CMT) within 10% of baseline value] were extracted from a computerized database. Of these, only pseudophakic eyes that underwent either IVA or DEX implant and had at least 1-year follow-up were included for analysis. METHODS: DEX implant was preferred before December 2020 and IVA after this time point. In the IVA group, patients were followed up every month while DEX were followed at least every 3 months. Reinjections were considered when vision dropped by at least 1 Snellen's line or CMT increased by at least 10% from the previous visit in both groups. MAIN OUTCOME MEASURES: Comparison of change in vision and CMT at 1-year follow-up in DEX versus IVA groups. RESULTS: Eighty-four eyes of 84 patients aged 54.4 + 4.4 years were included, 39 (46%) received DEX and 45 (54%) received IVA. Groups were comparable for baseline vision and CMT. Vision improved equally in both groups from 0.83 + 0.15 logMAR to 0.52 + 0.10 logMAR at 3 months ( P < 0.01) and then stabilized till 1 year. However, eyes in the IVA group were 6.5 times more likely (Odds ratio = 6.45, 95% CI = 1.3 - 31.9) to achieve >3-line improvement in vision. The CMT reduction was also comparable between groups (-169 + 51 in DEX vs. -174 + 49 in IVA, P = 0.67). More eyes in the IVA group required >3 injections (91% vs. 69% in DEX, P = 0.01). The IOP was significantly higher at 6 and 9 months in the DEX group and 5 eyes (13%) required IOP lowering medications. CONCLUSION: In pseudophakic eyes with recalcitrant DME not responding to ranibizumab, switching to IVA or DEX implant results in equal visual improvement and CMT reduction. Though >3-line improvement occurs more frequently with IVA, this comes at the expense of a greater number of injections and follow-up visits.


Subject(s)
Angiogenesis Inhibitors , Dexamethasone , Diabetic Retinopathy , Drug Implants , Glucocorticoids , Intravitreal Injections , Macular Edema , Pseudophakia , Receptors, Vascular Endothelial Growth Factor , Recombinant Fusion Proteins , Visual Acuity , Humans , Macular Edema/drug therapy , Macular Edema/etiology , Macular Edema/diagnosis , Recombinant Fusion Proteins/administration & dosage , Dexamethasone/administration & dosage , Male , Diabetic Retinopathy/drug therapy , Diabetic Retinopathy/diagnosis , Diabetic Retinopathy/complications , Female , Retrospective Studies , Visual Acuity/physiology , Receptors, Vascular Endothelial Growth Factor/administration & dosage , India , Glucocorticoids/administration & dosage , Middle Aged , Follow-Up Studies , Pseudophakia/drug therapy , Pseudophakia/complications , Treatment Outcome , Angiogenesis Inhibitors/administration & dosage , Tomography, Optical Coherence/methods , Aged , Time Factors , Vascular Endothelial Growth Factor A/antagonists & inhibitors
14.
J Fr Ophtalmol ; 47(4): 104105, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38428321

ABSTRACT

PURPOSE: To compare the visual outcomes in both eyes of patients who undergo phacoemulsification and trifocal intraocular lens (IOL) implantation and have asteroid hyalosis (AH) or synchysis scintillans (SS) in only one eye. METHODS: A retrospective comparative case series was performed. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction after implantation of the same model of trifocal IOL in both eyes (PhysIOL FineVision Pod-F and Micro-F and Rayner RayOne Trifocal). RESULTS: A total of 164 eyes of 82 patients (41 females, 50%) met the inclusion criteria. There were no statistically significant differences in sphere, cylinder, spherical equivalent, UDVA, UIVA, or UNVA between the groups. Postoperative CDVA was slightly better in the control group (logMAR 0.03) than in the AH/SS group (logMAR 0.04) (P: 0.014). There were no statistically significant differences in predictability, safety index, or efficacy index between the groups. Overall subjective satisfaction was good (98.2%). CONCLUSIONS: Visual outcomes and satisfaction are good after implantation of trifocal IOLs in eyes with AH or SS. Therefore, trifocal IOLs should not be ruled out in these patients when no other vitreoretinal disorder is present.


Subject(s)
Lenses, Intraocular , Orbital Diseases , Phacoemulsification , Female , Humans , Phacoemulsification/adverse effects , Lens Implantation, Intraocular/adverse effects , Retrospective Studies , Patient Satisfaction , Lenses, Intraocular/adverse effects , Refraction, Ocular , Vision Disorders , Prosthesis Design , Pseudophakia/complications , Pseudophakia/surgery
15.
J Cataract Refract Surg ; 50(7): 707-712, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38517986

ABSTRACT

PURPOSE: To investigate the long-term outcomes of congenital cataract surgery performed within the first 6 months of life. SETTING: 11 ophthalmic surgical sites in Japan. DESIGN: Retrospective chart review. METHODS: Medical charts were retrospectively reviewed for 216 eyes of 121 patients. The age at surgery was 2.9 ± 1.7 months, with follow-up duration 13.0 ± 2.3 years. The cohort consisted of 83 cases with bilateral aphakia, 12 with bilateral pseudophakia, 20 with unilateral aphakia, and 6 with unilateral pseudophakia. RESULTS: Surgical intervention within the critical period of visual system development (10 weeks for bilateral and 6 weeks for unilateral cases) led to significantly better final visual acuity than surgery conducted after this time frame. The incidence of secondary glaucoma was similar between groups while the occurrence of visual axis opacification was more frequent with earlier surgery. A forward stepwise multiple regression analysis revealed that the final visual acuity was significantly associated with laterality of cataract (better outcomes in bilateral cases), phakic status (with pseudophakia outperforming aphakia), presence of systemic and ocular comorbidities, and development of secondary glaucoma. Secondary glaucoma was significantly more prevalent in aphakic eyes than pseudophakic eyes. CONCLUSIONS: In patients with genuine congenital cataract, surgery within the critical period of visual development results in better final visual acuity, albeit with an increased risk of visual axis opacification. The use of IOL with sophisticated surgical techniques shows promise even in congenital cataract surgery.


Subject(s)
Aphakia, Postcataract , Cataract Extraction , Cataract , Lens Implantation, Intraocular , Pseudophakia , Visual Acuity , Humans , Visual Acuity/physiology , Retrospective Studies , Cataract/congenital , Cataract/complications , Infant , Male , Female , Pseudophakia/physiopathology , Follow-Up Studies , Aphakia, Postcataract/physiopathology , Aphakia, Postcataract/surgery , Treatment Outcome , Infant, Newborn , Glaucoma/surgery , Glaucoma/physiopathology , Glaucoma/congenital
16.
J Cataract Refract Surg ; 50(7): 724-732, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38530027

ABSTRACT

PURPOSE: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth-of-focus (EDOF) pattern and a diffractive multifocal platform. SETTING: Miranza COI Bilbao, Bilbao, Spain. DESIGN: Prospective case series. METHODS: 35 patients (51 to 84 years) with corneal astigmatism ranging from 0.75 to 2.19 diopters (D) undergoing bilateral cataract surgery with implantation of the Synergy Toric II IOL were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. RESULTS: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06 ± 0.11 logMAR, 0.13 ± 0.12 logMAR, and 0.13 ± 0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11 ± 0.12 logMAR and 0.10 ± 0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within ±0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 D and 0.50 D, with a mean value of 0.04 ± 0.16 D. Mean absolute IOL rotation was 3.79 ± 2.94 degrees. Significant improvements were found in all Rasch-calibrated scores obtained with Catquest-9SF ( P < .001). CONCLUSIONS: The implantation of the toric presbyopia-correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.


Subject(s)
Astigmatism , Lens Implantation, Intraocular , Lenses, Intraocular , Presbyopia , Refraction, Ocular , Visual Acuity , Humans , Visual Acuity/physiology , Presbyopia/surgery , Presbyopia/physiopathology , Prospective Studies , Aged , Refraction, Ocular/physiology , Middle Aged , Aged, 80 and over , Male , Female , Astigmatism/physiopathology , Astigmatism/surgery , Phacoemulsification , Prosthesis Design , Pseudophakia/physiopathology , Surveys and Questionnaires , Treatment Outcome
17.
BMC Ophthalmol ; 24(1): 136, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38532398

ABSTRACT

PURPOSE: To determine the distribution of subfoveal choroidal thickness (SFCT) and its associated demographic, ocular, and systemic factors in an elderly population. METHODS: This report is part of the Tehran Geriatric Eye Study (TGES); a population-based cross-sectional study that was conducted on the urban elderly population of Tehran, aged 60 years and above using multi-stage stratified random cluster sampling. Choroidal imaging was performed using Spectralis SD-OCT with enhanced depth imaging mode. RESULTS: The average SFCT was 265.3 ± 25.9 µm (95% CI: 262.8-267.7) in the whole sample. According to the multiple generalized estimating equation (GEE) model, pseudophakia had a statistically significant direct relationship with SFCT (coefficient = 5.69), and history of cerebrovascular accident (CVA) was significantly inversely related to SFCT (coefficient=-4.77). Moreover, there was a significant interaction between age and sex in the average SFCT so that with increasing age, the SFCT increased in men and decreased in women. CONCLUSION: The normal values of SFCT in the present study can be used as a reference database for clinical and research purposes. Age-sex interaction, pseudophakia, and history of CVA were significantly associated with SFCT in the elderly population. It is recommended that these factors be taken into account when interpreting SFCT data.


Subject(s)
Choroid , Pseudophakia , Male , Humans , Aged , Female , Cross-Sectional Studies , Iran , Tomography, Optical Coherence/methods
18.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38466765

ABSTRACT

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Subject(s)
Lens, Crystalline , Myopia , Phakic Intraocular Lenses , Humans , Lens Implantation, Intraocular/methods , Myopia/surgery , Accommodation, Ocular , Anterior Chamber/diagnostic imaging , Pseudophakia/surgery , Tomography, Optical Coherence , Biometry
19.
BMC Ophthalmol ; 24(1): 86, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38409015

ABSTRACT

BACKGROUND: To evaluate visual performance after implantation of the TFNT (Acrysof Panoptix, Alcon, Fort Worth, Texas, USA) and CNWT (Clareon Panoptix, Alcon, Fort Worth, Texas, USA) intraocular lens (IOL), and compare the lens shape observed by scanning electron microscope (SEM). METHODS: Eighteen patients (18 eyes) received implantation of the CNWT and Twenty patients (20 eyes) received implantation of the TFNT. Exclusion criteria were previous ocular surgeries, ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 1 months including manifest refraction; evaluation of refractive error, distance-corrected visual acuity (DCVA) at 5 m, 1 m, 70 cm, 50 cm, 40 cm, and 30 cm, slit-lamp examination; defocus curve testing; contrast sensitivity (CS) was performed. The lens shape of the TFNT and the CNWT was examined under SEM. RESULTS: Mean spherical equivalent was 0.11 ± 0.41 D (CNWT group) and 0.12 ± 0.34 D (TFNT group) 1 month postoperation. DCVA and defocus curve showed no significant difference between the two groups. CS was significantly higher in CNWT group than TFNT group at spatial frequencies of 6 cycles per degree (cpd). Observation of the IOL with a scanning electron microscope (SEM) revealed that CNWT group had improved diffraction structure and edge processing accuracy compared to TFNT group. CONCLUSION: There was no significant difference between the two groups in the defocus curve and visual acuity at all distances. CS was better in the CNWT group than in the TFNT group. IOL surface features may affect CS.


Subject(s)
Lenses, Intraocular , Phacoemulsification , Humans , Microscopy, Electron, Scanning , Lens Implantation, Intraocular , Pseudophakia/surgery , Vision, Binocular , Refraction, Ocular , Prosthesis Design
20.
BMC Ophthalmol ; 24(1): 72, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38365667

ABSTRACT

PURPOSE: To compare the rotational stability of a monofocal and a diffractive multifocal toric intraocular lens(IOLs) with identical design and material. METHODS: This prospective study enrolled patients who underwent plate-haptic toric IOL (AT TORBI 709 M and AT LISA 909 M) implantation. Propensity score matching (PSM) was performed to balance baseline factors. Follow-up examinations were conducted at 1 h, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was used to investigate the changes in IOL rotation over time. A 2-week timeframe was utilized to assess differences in IOL rotation between the two groups. RESULT: After PSM, a total of 126 eyes were selected from each group for further analysis. Postoperatively, the time course of IOL rotation change in the two groups remained consistent, with the greatest rotation occurring between 1 h and 1 day postoperatively. At the 2-week postoperative mark, the monofocal toric IOL exhibited a higher degree of rotation compared to the multifocal toric IOL (5.40 ± 7.77° vs. 3.53 ± 3.54°, P = 0.015). In lens thickness(LT) ≥ 4.5 mm and white-to-white distance(WTW) ≥ 11.6 mm subgroups, the monofocal toric IOL rotated greater than the multifocal toric IOL (P = 0.026 and P = 0.011, respectively). CONCLUSION: The diffractive multifocal toric IOL exhibits superior rotational stability compared to the monofocal toric IOL, especially in subgroups LT ≥ 4.5 mm and WTW ≥ 11.6 mm. Moreover, the time course of IOL rotation change is consistent for both, with the maximum rotation occurring between 1 h and 1 day postoperatively.


Subject(s)
Astigmatism , Lenses, Intraocular , Phacoemulsification , Humans , Lens Implantation, Intraocular , Prospective Studies , Pseudophakia/surgery , Visual Acuity , Propensity Score , Astigmatism/surgery , Refraction, Ocular
SELECTION OF CITATIONS
SEARCH DETAIL