Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Haemophilia ; 30(1): 214-223, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37902390

RESUMO

INTRODUCTION: Structural and chemical modifications of factor VIII (FVIII) products may influence their behaviour in FVIII activity assays. Hence, it is important to assess the performance of FVIII products in these assays. Efanesoctocog alfa is a new class of FVIII replacement therapy designed to provide both high sustained factor activity levels and prolonged plasma half-life. AIM: Evaluate the accuracy of measuring efanesoctocog alfa FVIII activity in one-stage clotting assays (OSAs) and chromogenic substrate assays (CSAs). METHODS: Human plasma with no detectable FVIII activity was spiked with efanesoctocog alfa or a full-length recombinant FVIII product comparator, octocog alfa, at nominal concentrations of 0.80 IU/mL, 0.20 IU/mL, or 0.05 IU/mL, based on labelled potency. Clinical haemostasis laboratories (N = 35) tested blinded samples using in-house assays. Data from 51 OSAs (14 activated partial thromboplastin time [aPTT] reagents) and 42 CSAs (eight kits) were analyzed. RESULTS: Efanesoctocog alfa activity was reliably (±25% of nominal activity) measured across all concentrations using OSAs with Actin FSL and multiple other aPTT reagents. Under- and overestimation of FVIII activity occurred with some reagents. No specific trend was observed for any class of aPTT activators. A two- to three-fold overestimation was consistently observed using CSAs and the OSA with Actin FS as the aPTT reagent across evaluated concentrations. CONCLUSION: Under- or overestimation occurred with some specific OSAs and most CSAs, which has been previously observed with other modified FVIII replacement products. Efanesoctocog alfa FVIII activity was measured with acceptable accuracy and reliability using several OSA methods and commercial plasma standards.


Assuntos
Hemofilia A , Hemostáticos , Apneia Obstrutiva do Sono , Humanos , Actinas , Testes de Coagulação Sanguínea/métodos , Compostos Cromogênicos/uso terapêutico , Fator VIII/uso terapêutico , Hemofilia A/tratamento farmacológico , Hemostasia , Hemostáticos/uso terapêutico , Indicadores e Reagentes , Laboratórios , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/tratamento farmacológico
2.
J Blood Med ; 12: 115-122, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33664606

RESUMO

PURPOSE: Primary prophylaxis, using factor VIII replacement, is the recognized standard of care for severe hemophilia A. Recombinant factor VIII-Fc fusion protein (rFVIIIFc) and emicizumab, a humanized, bispecific antibody, are approved for routine prophylaxis of bleeding episodes in severe hemophilia A. These products have different mechanisms of action, methods of administration and treatment schedules. In the absence of head-to-head trials, indirect treatment comparisons can provide informative evidence on the relative efficacy of the two treatments. The aim of the study was to compare the approved dosing regimens for each product, rFVIIIFc individualized prophylaxis and emicizumab administered once every week (Q1W), every 2 weeks (Q2W) or every 4 weeks (Q4W), based on clinical trial evidence. PATIENTS AND METHODS: The comparison was conducted using matching-adjusted indirect comparison since clinical evidence did not form a connected network. Individual patient data for rFVIIIFc (A-LONG) were compared with data for emicizumab (HAVEN trial program) for mean annualized bleeding rate (ABR) and proportion of patients with zero bleeds. Safety data reported across the analyzed treatment arms were tabularized but not formally compared. RESULTS: After matching, no significant differences were observed between mean ABR for rFVIIIFc and emicizumab administered Q1W, Q2W or Q4W. The proportion of patients with zero bleeds was significantly higher with rFVIIIFc compared with emicizumab administered Q4W (51.2% versus 29.3%, respectively; odds ratio 2.53; 95% confidence interval 1.09-5.89); no significant differences noted when rFVIIIFc was compared with emicizumab administered Q1W or Q2W. The mean number of adverse events expressed per participant was 1.9 for individualized prophylaxis with rFVIIIFc and 3.7-4.0, 4.1 and 3.6 for emicizumab administered Q1W, Q2W or Q4W, respectively. CONCLUSION: This indirect treatment comparison suggests that rFVIIIFc individualized prophylaxis is more efficacious than emicizumab Q4W, and at least as effective as more frequent emicizumab regimens, for the management of hemophilia A.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA