Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Radiol Case Rep ; 19(8): 3425-3428, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38881621

RESUMO

We present a case of an 81-year-old woman who presented to the emergency department with bleeding from a right breast wound. The patient had prior imaging suggestive of bilateral silicone implant rupture and a history of low tolerance for MRI scans. Ultrasound imaging in the emergency setting showed findings in the right breast suggestive of a fistula with free silicone and hematoma. A subsequent photon-counting CT scan with custom silicone-specific segmentation allowed differentiation of silicone from hematoma, provided anatomic assessment and location of the fistula, and revealed bilateral silicone-induced lymphadenopathy.

2.
Abdom Radiol (NY) ; 49(5): 1762-1770, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38546824

RESUMO

PURPOSE: Photon-counting detector CT (PCD CT) is a promising technology for abdominal imaging due to its ability to provide high spatial and contrast resolution images with reduced patient radiation exposure. However, there is currently no consensus regarding the optimal imaging protocols for PCD CT. This article aims to present the PCD CT abdominal imaging protocols used by two tertiary care academic centers in the United States. METHODS: A review of PCD CT abdominal imaging protocols was conducted by two abdominal radiologists at different academic institutions. Protocols were compared in terms of acquisition parameters and reconstruction settings. Both imaging centers independently selected similar protocols for PCD CT abdominal imaging, using QuantumPlus mode. RESULTS: There were some differences in the use of reconstruction kernels and iterative reconstruction levels, however the individual combination at each site resulted in similar image impressions. Overall, the imaging protocols used by both centers provide high-quality images with low radiation exposure. CONCLUSION: These findings provide valuable insights into the development of standardized protocols for PCD CT abdominal imaging, which can help to ensure consistent as well as high-quality imaging across different institutions and allow for future multicenter research collaborations.


Assuntos
Doses de Radiação , Radiografia Abdominal , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Radiografia Abdominal/métodos , Fótons , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Consenso , Estados Unidos , Centros Médicos Acadêmicos
3.
AJR Am J Roentgenol ; 221(3): 363-371, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37095666

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT has been shown to reduce radiation dose and improve image quality in adult chest CT examinations; its potential impact in pediatric CT is not well documented. OBJECTIVE. The purpose of our study was to compare radiation dose, objective image quality, and subjective image quality of PCD CT and energy-integrating detector (EID) CT in children undergoing high-resolution CT (HRCT) of the chest. METHODS. This retrospective study included 27 children (median age, 3.9 years; 10 girls, 17 boys) who underwent PCD CT between March 1, 2022, and August 31, 2022, and 27 children (median age, 4.0 years; 13 girls, 14 boys) who underwent EID CT between August 1, 2021, and January 31, 2022; all examinations comprised clinically indicated chest HRCT. The patients in the two groups were matched by age and water-equivalent diameter. Radiation dose parameters were recorded. One observer placed ROIs to measure objective parameters (lung attenuation, image noise, and SNR). Two radiologists independently assessed subjective measures (overall image quality and motion artifacts) using 5-point Likert scales (1 = highest quality). Groups were compared. RESULTS. PCD CT, in comparison with EID CT, showed lower median CTDIvol (0.41 vs 0.71 mGy, p < .001), DLP (10.2 vs 13.7 mGy × cm, p = .008), size-specific dose estimate (0.82 vs 1.34 mGy, p < .001), and tube current-exposure time product (48.0 vs 202.0 mAs, p < .001). PCD CT and EID CT showed no significant difference in right upper lobe (RUL) lung attenuation (mean, -793 vs -750 HU; p = .09), right lower lobe (RLL) lung attenuation (mean, -745 vs -716 HU; p = .23), RUL image noise (mean, 55 vs 51 HU; p = .27), RLL image noise (mean, 59 vs 57 HU; p = .48), RUL SNR (mean, -14.9 vs -15.8; p = .89), or RLL SNR (mean, -13.1 vs -13.6; p = .79). PCD CT and EID CT showed no significant difference in median overall image quality for reader 1 (1.0 vs 1.0, p = .28) or reader 2 (1.0 vs 1.0, p = .17) or median motion artifacts for reader 1 (1.0 vs 1.0, p = .07) or reader 2 (1.0 vs 1.0, p = .22). CONCLUSION. PCD CT showed significantly reduced dose levels without a significant difference in objective or subjective image quality compared with EID CT. CLINICAL IMPACT. These data expand understanding of the capabilities of PCD CT and support its routine use in children.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Masculino , Adulto , Feminino , Humanos , Criança , Pré-Escolar , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Pulmão , Imagens de Fantasmas , Doses de Radiação
4.
Pol J Radiol ; 87: e415-e420, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35979149

RESUMO

Purpose: The aim of this multicentric study is to illustrate how the COVID-19 pandemic lockdown affected the workload and outcomes of radiological examinations in emergency radiology. Material and methods: The exams performed in the radiology departments of 4 Italian hospitals during 3 weeks of the Italian lockdown were retrospectively reviewed and compared to the exams conducted during the same period in 2019. Only exams from the emergency department (ED) were included. Two radiologists from each hospital defined the cases as positive or negative findings, based on independent blind readings of the imaging studies. In the case of differences in the evaluation, consensus was reached amongst them via discussion. Continuous measurements are presented as median and interquartile range, while categorical measurements are presented as frequency and percentage; p-values were calculated using the t-test, Mann-Whitney test, and the c2 test. Results: There were 745 patients (53% male; 62 years [44-78]) who underwent radiological examinations in 2020 vs. 2623 (52% male; 56 years [35-76]) in 2019 (p < 0.001). Furthermore, the total number of ED exams dropped from 3206 (2019) to 939 (2020), with a relative increase of CT examinations from 23% to 33% (p < 0.001). The percentage of patients with a positive finding was significantly higher in 2020 (355, 48%) compared to 2019 (684, 26%) (p < 0.001). Conclusions: Our findings show that despite the reduction of emergency radiological examinations, there was a rela-tive increase in the number of positive cases. These significant findings are crucial to ensure better organization of radiology departments and improve patient management during similar health emergencies in the future.

5.
J Thorac Imaging ; 37(5): 307-314, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35475983

RESUMO

OBJECTIVES: We aimed to validate and test a prototype algorithm for automated dual-energy computed tomography (DECT)-based myocardial extracellular volume (ECV) assessment in patients with various cardiomyopathies. METHODS: This retrospective study included healthy subjects (n=9; 61±10 y) and patients with cardiomyopathy (n=109, including a validation cohort n=60; 68±9 y; and a test cohort n=49; 69±11 y), who had previously undergone cardiac DECT. Myocardial ECV was calculated using a prototype-based fully automated algorithm and compared with manual assessment. Receiver-operating characteristic analysis was performed to test the algorithm's ability to distinguish healthy subjects and patients with cardiomyopathy. RESULTS: The fully automated method led to a significant reduction of postprocessing time compared with manual assessment (2.2±0.4 min and 9.4±0.7 min, respectively, P <0.001). There was no significant difference in ECV between the automated and manual methods ( P =0.088). The automated method showed moderate correlation and agreement with the manual technique ( r =0.68, intraclass correlation coefficient=0.66). ECV was significantly higher in patients with cardiomyopathy compared with healthy subjects, regardless of the method used ( P <0.001). In the test cohort, the automated method yielded an area under the curve of 0.98 for identifying patients with cardiomyopathies. CONCLUSION: Automated ECV estimation based on DECT showed moderate agreement with the manual method and matched with previously reported ECV values for healthy volunteers and patients with cardiomyopathy. The automatically derived ECV demonstrated an excellent diagnostic performance to discriminate between healthy and diseased myocardium, suggesting that it could be an effective initial screening tool while significantly reducing the time of assessment.


Assuntos
Cardiomiopatias , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Fibrose , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia
6.
Radiology ; 302(1): 50-58, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34609200

RESUMO

Background The role of CT angiography-derived fractional flow reserve (CT-FFR) in pre-transcatheter aortic valve replacement (TAVR) assessment is uncertain. Purpose To evaluate the predictive value of on-site machine learning-based CT-FFR for adverse clinical outcomes in candidates for TAVR. Materials and Methods This observational retrospective study included patients with severe aortic stenosis referred to TAVR after coronary CT angiography (CCTA) between September 2014 and December 2019. Clinical end points comprised major adverse cardiac events (MACE) (nonfatal myocardial infarction, unstable angina, cardiac death, or heart failure admission) and all-cause mortality. CT-FFR was obtained semiautomatically using an on-site machine learning algorithm. The ability of CT-FFR (abnormal if ≤0.75) to predict outcomes and improve the predictive value of the current noninvasive work-up was assessed. Survival analysis was performed, and the C-index was used to assess the performance of each predictive model. To compare nested models, the likelihood ratio χ2 test was performed. Results A total of 196 patients (mean age ± standard deviation, 75 years ± 11; 110 women [56%]) were included; the median time of follow-up was 18 months. MACE occurred in 16% (31 of 196 patients) and all-cause mortality in 19% (38 of 196 patients). Univariable analysis revealed CT-FFR was predictive of MACE (hazard ratio [HR], 4.1; 95% CI: 1.6, 10.8; P = .01) but not all-cause mortality (HR, 1.2; 95% CI: 0.6, 2.2; P = .63). CT-FFR was independently associated with MACE (HR, 4.0; 95% CI: 1.5, 10.5; P = .01) when adjusting for potential confounders. Adding CT-FFR as a predictor to models that include CCTA and clinical data improved their predictive value for MACE (P = .002) but not all-cause mortality (P = .67), and it showed good discriminative ability for MACE (C-index, 0.71). Conclusion CT angiography-derived fractional flow reserve was associated with major adverse cardiac events in candidates for transcatheter aortic valve replacement and improved the predictive value of coronary CT angiography assessment. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Choe in this issue.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Medição de Risco
7.
J Thorac Imaging ; 37(3): 154-161, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34387227

RESUMO

OBJECTIVES: The aim of the study is to investigate the performance of artificial intelligence (AI) convolutional neural networks (CNN) in detecting lung nodules on chest computed tomography of patients with complex lung disease, and demonstrate its noninferiority when compared against an experienced radiologist through clinically relevant assessments. METHODS: A CNN prototype was used to retrospectively evaluate 103 complex lung disease cases and 40 control cases without reported nodules. Computed tomography scans were blindly evaluated by an expert thoracic radiologist; a month after initial analyses, 20 positive cases were re-evaluated with the assistance of AI. For clinically relevant applications: (1) AI was asked to classify each patient into nodules present or absent and (2) AI results were compared against standard radiology reports. Standard statistics were performed to determine detection performance. RESULTS: AI was, on average, 27 seconds faster than the expert and detected 8.4% of nodules that would have been missed. AI had a sensitivity of 67.7%, similar to an accuracy reported for experienced radiologists. AI correctly classified each patient (nodules present/absent) with a sensitivity of 96.1%. When matched against radiology reports, AI performed with a sensitivity of 89.4%. Control group assessment demonstrated an overall specificity of 82.5%. When aided by AI, the expert decreased the average assessment time per case from 2:44 minutes to 35.7 seconds, while reporting an overall increase in confidence. CONCLUSION: In a group of patients with complex lung disease, the sensitivity of AI is similar to an experienced radiologist and the tool helps detect previously missed nodules. AI also helps experts analyze for lung nodules faster and more confidently, a feature that is beneficial to patients and favorable to hospitals due to increased patient load and need for shorter turnaround times.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Inteligência Artificial , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
BMC Med ; 19(1): 55, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33658025

RESUMO

BACKGROUND: Artificial intelligence (AI) in diagnostic radiology is undergoing rapid development. Its potential utility to improve diagnostic performance for cardiopulmonary events is widely recognized, but the accuracy and precision have yet to be demonstrated in the context of current screening modalities. Here, we present findings on the performance of an AI convolutional neural network (CNN) prototype (AI-RAD Companion, Siemens Healthineers) that automatically detects pulmonary nodules and quantifies coronary artery calcium volume (CACV) on low-dose chest CT (LDCT), and compare results to expert radiologists. We also correlate AI findings with adverse cardiopulmonary outcomes in a retrospective cohort of 117 patients who underwent LDCT. METHODS: A total of 117 patients were enrolled in this study. Two CNNs were used to identify lung nodules and CACV on LDCT scans. All subjects were used for lung nodule analysis, and 96 subjects met the criteria for coronary artery calcium volume analysis. Interobserver concordance was measured using ICC and Cohen's kappa. Multivariate logistic regression and partial least squares regression were used for outcomes analysis. RESULTS: Agreement of the AI findings with experts was excellent (CACV ICC = 0.904, lung nodules Cohen's kappa = 0.846) with high sensitivity and specificity (CACV: sensitivity = .929, specificity = .960; lung nodules: sensitivity = 1, specificity = 0.708). The AI findings improved the prediction of major cardiopulmonary outcomes at 1-year follow-up including major adverse cardiac events and lung cancer (AUCMACE = 0.911, AUCLung Cancer = 0.942). CONCLUSION: We conclude the AI prototype rapidly and accurately identifies significant risk factors for cardiopulmonary disease on standard screening low-dose chest CT. This information can be used to improve diagnostic ability, facilitate intervention, improve morbidity and mortality, and decrease healthcare costs. There is also potential application in countries with limited numbers of cardiothoracic radiologists.


Assuntos
Inteligência Artificial/normas , Cálcio/metabolismo , Vasos Coronários/fisiopatologia , Detecção Precoce de Câncer/métodos , Neoplasias Pulmonares/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Estudos de Coortes , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Prognóstico , Estudos Retrospectivos
9.
Radiol Technol ; 92(3): 232-239, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33472875

RESUMO

PURPOSE: To evaluate a new contrast media (CM) injection system in patients undergoing coronary computed tomography angiography (CCTA). METHODS: Seventy-one consecutive patients (33 men and 38 women, mean age 59.0 ± 14.5 years) who underwent CCTA between February and April 2019 using the CT injection system MEDRAD Stellant FLEX (Bayer) were included retrospectively in this single-center study. Quantitative and qualitative image quality parameters were assessed, and the injection system's usability and operational efficiency were evaluated. Results were compared with a matched control group. RESULTS: All examinations were rated as diagnostic. Usability and operational efficiency of the new injector were rated higher than that of the standard injector system, and no significant differences were found for quantitative and qualitative image quality parameters compared with the control group (P ≥ .05). DISCUSSION: Software-based injection facilitates individualized CM application while maintaining high image quality standards in CCTA. Diagnostic accuracy analysis was not performed, but as image quality analysis showed no significant differences, no discrepancies regarding this issue are expected. CONCLUSION: This study demonstrates that the MEDRAD Stellant FLEX CT injection system allows for consistent high-quality CCTA scanning with increased usability and operational efficiency.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Adulto , Idoso , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
Abdom Radiol (NY) ; 46(3): 909-918, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32936419

RESUMO

PURPOSE: To evaluate how initial abdominopelvic CT findings and staging correlate with outcomes in a cohort of patients aged 18-40 years. METHODS: We evaluated all young adult patients at a single tertiary center diagnosed with histopathologically confirmed CRC who also had CT of the abdomen and pelvis at the time of initial diagnosis. Demographics, symptoms, CT findings, staging, treatments, and outcomes at 1 year and 5 years were recorded. RESULTS: Of 91 patients who met initial inclusion criteria, 81.8% had a mass present on CT, with an average size of 4.8 cm ± 2.9. A majority of patients were surgical stage III or IV (64.3%). Advanced AJCC stage was more common with rectal tumors and metastatic disease on initial CT (p < 0.0001). In a subgroup analysis, almost all patients initially staged 4A or higher had progression of disease. At the final follow-up visit, by RECIST 1.1 criteria, 58.8% had progressive disease, 35.3% complete response, and 3.9% stable disease. The overall 5-year survival rate in this subgroup was 40% with lower survival probability with increasing stage (p = 0.0001). CONCLUSION: Most young adult patients presented with large tumors on imaging, increasing the likelihood of identification on CT. Tumors initially presenting in the rectum with enlarged lymph nodes and/or with distant metastases on CT were more often associated with advanced surgical stage and poorer prognosis. A majority of patients presented at an advanced stage, most commonly stage 4A, and had progression of disease at follow-up.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Retais , Humanos , Estadiamento de Neoplasias , Reto , Tomografia Computadorizada por Raios X , Adulto Jovem
11.
AJR Am J Roentgenol ; 215(5): 1049-1056, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32960669

RESUMO

OBJECTIVE. The purpose of this study was to prospectively evaluate, using software support, the feasibility and the quantitative and qualitative image quality parameters of a tube voltage-tailored contrast medium (CM) application protocol for patient-specific injection during coronary CT angiography (CCTA). SUBJECTS AND METHODS. In the Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography (VOLCANIC-CTA) study, a single-center trial, 120 patients referred for CCTA were prospectively assigned to a tube voltage-tailored CM injection protocol. Automated tube voltage levels were selected in 10-kV intervals and ranged from 70 to 130 kV, and the iodine delivery rate (IDR) was adapted to the tube voltage level using dedicated software. The administered CM volume (370 mg I/mL) ranged from 33 mL at 70 kV (IDR, 0.7 g I/s) to 65 mL at 130 kV (IDR, 1.7 g I/s). Attenuation was measured in the aorta and coronary arteries to calculate quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and 5-point scales were used to evaluate overall image quality. Radiation metrics were also assessed and compared among the protocols. RESULTS. The mean age of the study patients was 62.5 ± 11.9 (SD) years. Image quality was rated as diagnostic in all patients. Contrast attenuation peaked at 70 kV (p < 0.001), whereas SNR and CNR parameters showed no significant differences between tube voltage levels (p ≥ 0.085). Additionally, no significant differences in subjective image quality parameters were found among the different protocols (p ≥ 0.139). The lowest radiation dose values were observed in the group assigned to the 70-kV protocol, which had a median radiation effective dose of 2.0 mSv (p < 0.001). CONCLUSION. The proposed tube voltage-tailored injection protocol allows individualized scanning of patients undergoing CCTA and significantly reduces CM and radiation dose while maintaining a high diagnostic image quality.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Adulto , Idoso , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
PLoS One ; 15(6): e0234311, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32511272

RESUMO

OBJECTIVE: To compare the performance of an 18-gauge nonfenestrated catheter (18-NFC) with a 22-gauge fenestrated catheter (22-FC) for cardiac CT angiography (CCTA) in patients with suspected coronary heart disease. SUBJECTS AND METHODS: 74 consecutive patients imaged on a 2nd generation dual-source CT with arterial phase CCTA were included in this retrospective investigation to either an 18-NFC or 22-FC. In comparison to the 18-NFC, the 22-FC has three additional perforations for contrast agent dispersal proximal to the tip. We examined the two groups for differences in their average attenuation in the right and left ventricles (RV, LV) and in the atrium (RA, LA) as well as in the proximal right coronary artery (RCA) and the left main coronary artery (LM). The averages were calculated for both the 18-NFC and 22-FC. RESULTS: Catheters were successfully placed on the first attempt 97% (36/37) for 18-NFC and 95% (35/37) for the 22-FC. The following enhancement levels were measured: 22-FC (in Hounsfield-Units (HU)): RV = 203±29, LV = 523±36, RA = 198±29, LA = 519±38, RCA = 547±26, LM = 562±25; 18-NFC: RV = 146±26, LV = 464±32, RA = 141±24, LA = 438±35, RCA = 501±23, LM = 523±23; RV (p = 0,03), LV (p = 0.12), RA (p = 0.02), LA (p = 0.04), RCA (p = 0.3), LM (p = 0.33). CONCLUSION: No significant differences in attenuation levels as well as in image quality of the coronary arteries were found between NFC and FC. Nevertheless, the 22-gauge FC examinations showed significantly higher attenuation in the left and right atrium as well as the right ventricle. Patients with poor venous access may benefit from a smaller gauge catheter that can deliver sufficiently high flow rates for CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Doença das Coronárias/diagnóstico por imagem , Dispositivos de Acesso Vascular , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
13.
Eur Radiol ; 30(11): 5834-5840, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32468107

RESUMO

PURPOSE: We prospectively investigate the feasibility of a patient specific automated tube voltage selection (ATVS)-based coronary artery calcium scoring (CACS) protocol, using a kV-independent reconstruction algorithm, to achieve significant dose reductions while maintaining the overall cardiac risk classification. METHODS: Forty-three patients (mean age, 61.8 ± 9.0 years; 40% male) underwent a clinically indicated CACS scan at 120kVp, as well as an additional CACS acquisition using an individualized tube voltage between 70 and 130kVp based on the ATVS selection (CARE-kV). Datasets of the additional CACS scans were reconstructed using a kV-independent algorithm that allows for calcium scoring without changing the weighting threshold of 130HU, regardless of the tube voltage chosen for image acquisition. Agatston scores and radiation dose derived from the different ATVS-based CACS studies were compared to the standard acquisition at 120kVp. RESULTS: Thirteen patients displayed a score of 0 and were correctly identified with the ATVS protocol. Agatston scores derived from the standard 120kVp (median, 33.4; IQR, 0-289.7) and the patient-tailored kV-independent protocol (median, 47.5; IQR, 0-287.5) showed no significant differences (p = 0.094). The intra-class correlation for Agatston scores derived from the two different protocols was excellent (ICC = 0.99). The mean dose-length-product was 29.8 ± 11.9 mGy × cm using the ATVS protocol and 31.7 ± 11.4 mGy × cm using the standard 120kVp protocol (p < 0.001). Additionally, 95% of patients were classified into the same risk category (0, 1-10, 11-100, 101-400, or > 400) using the patient-tailored protocol. CONCLUSIONS: ATVS-based CACS, using a kV-independent algorithm, allows for high accuracy compared to the standard 120kVp scanning, while significantly reducing radiation dose parameters. KEY POINTS: • ATVS allows for CT scanning with reduced radiation dose values. • KV-independent CACS is feasible at any tube voltage between 70 and 130 kVp. • ATVS applied to kV-independent CACS can significantly reduce the radiation dose.


Assuntos
Algoritmos , Cálcio/metabolismo , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/metabolismo , Vasos Coronários/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Acta Biomed ; 91(4): e2020166, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-33525213

RESUMO

BACKGROUND: On March 9th, 2020, the Italian government decided to go into lockdown due to the COVID-19 pandemic, which led to changes in the workflow of radiological examinations. AIMS: Aim of the study is to illustrate how the workload and outcome of radiological exams changed in a community hospital during the pandemic. METHODS AND MATERIAL: The exams performed in the radiology department from March 9th to March 29th, 2020 were retrospectively reviewed and compared to the exams conducted during the same time-period in 2019. Only exams coming from the emergency department (ED) were included. Two radiologists defined the cases as positive or negative findings, based on independent blind readings of the imaging studies. Categorical measurements are presented as frequency and percentages, and p-values are calculated using the Chi-squared test. RESULTS AND CONCLUSIONS: There was a significant reduction in the amount of exams performed in 2020: there were 143 (93|65% male, 60.7±21.5 years) patients who underwent radiological examinations from the ED vs. 485 (255|53% male, 51.2±24.8 years) in 2019. Furthermore, the total number of ED exams dropped from 699 (2019) to 215 (2020). However, the percentage of patients with a positive result was significantly higher in 2020 (69|48%) compared to 2019 (151|31%) (p<.001). The reduction of emergency radiological examinations might be a result of the movement restrictions enforced during the lockdown, and possible fear of the hospital as a contagious place. This translated to a relative increase of positive cases as only patients with very serious conditions were accessing the ED.


Assuntos
COVID-19 , Quarentena , Radiografia/estatística & dados numéricos , Carga de Trabalho/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Hospitais Comunitários , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Serviço Hospitalar de Radiologia/estatística & dados numéricos , Estudos Retrospectivos
15.
J Cardiovasc Comput Tomogr ; 14(3): 246-250, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31843523

RESUMO

PURPOSE: To investigate the accuracy of Agatston scoring and potential for radiation dose reduction of a coronary artery calcium scoring (CACS) CT protocol at 100 kV with tin filtration (Sn100kV) and kV-independent iterative reconstruction, compared to standard 120 kV acquisitions. MATERIALS AND METHODS: With IRB approval and in HIPAA compliance, 114 patients (61.8 ± 9.6 years; 66 men) underwent CACS using a standard 120 kV protocol and an additional Sn100kV CACS scan. The two datasets were reconstructed using a medium sharp convolution algorithm and in addition the Sn100kV scans were reconstructed iteratively based on a kV-independent algorithm. Agatston scores and radiation dose values were compared between the Sn100kV and the standard 120 kV protocol. RESULTS: Median Agatston scores derived from the Sn100kV protocol with the kV-independent algorithm and the standard 120 kV were 21.4 (IQR, 0-173.8) and 24.7 (IQR, 0-171.1) respectively, with no significant differences (p=0.18). Agatston scores derived from the two different protocols had an excellent correlation (r = 0.99). The dose-length-product was 11.5 ± 4.1 mGy × cm using Sn100kV and 50.4 ± 24.9 mGy × cm using the standard 120 kV protocol (p < 0.01), resulting in a significantly lower (77%) effective dose at Sn100kV (0.16 ± 0.06 mSv vs. 0.71 ± 0.35 mSv, p < 0.01). Additionally, 99% of the patients were classified into the same risk category (0, 1-10, 11-100, 101-400, or >400) using the Sn100kV protocol. CONCLUSION: CACS at Sn100kV using the kV-independent iterative algorithm is feasible and provides high accuracy when compared to standard 120 kV scanning. Furthermore, radiation dose can be significantly reduced for this screening application in a priori healthy individuals.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Calcificação Vascular/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
16.
J Cardiovasc Comput Tomogr ; 14(2): 162-167, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31615736

RESUMO

OBJECTIVE: To evaluate the feasibility of dual-energy CT (DECT)-based iodine quantification to estimate myocardial extracellular volume (ECV) fraction in patients with and without cardiomyopathy (CM), as well as to assess its ability to distinguish healthy myocardial tissue from cardiomyopathic, with the goal of defining a threshold ECV value for disease detection. METHODS: Ten subjects free of heart disease and 60 patients with CM (mean age 66.4 ±â€¯9.4; 59 males and 11 females; 40 ischemic and 20 non-ischemic CM) underwent late iodine enhanced DECT imaging. Myocardial iodine maps were obtained using 3-material decomposition. ECV of the left ventricle was estimated from hematocrit levels and the iodine maps using the AHA 16-segment model. Receiver operating characteristic curve analysis was performed, with corresponding area under the curve, along with Youden's index assessment, to establish a threshold for CM detection. RESULTS: The median ECV for healthy myocardium, non-ischemic CM, and ischemic CM were 25.4% (22.9-27.3), 38.3% (33.7-43.0), and 36.9% (32.4-41.1), respectively. Healthy myocardium showed significantly lower ECV values compared to ischemic and non-ischemic CM (p < 0.001). From Youden's index analysis, an ECV>29.5% would indicate the presence of CM in the myocardium (sensitivity = 90.3; specificity = 90.3); the AUC for this criterion was 0.950 (p < 0.001). CONCLUSION: The findings of this study resulted in a statistically significant distinction between healthy myocardium and CM ECVs. This led to the establishment of a promising threshold ECV value that could facilitate the differentiation between healthy and diseased myocardium, and highlights the potential of this DECT methodology to detect cardiomyopathic tissue.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Miocárdio/patologia , Tomografia Computadorizada por Raios X , Idoso , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sobrevivência de Tecidos
18.
Invest Radiol ; 52(11): 693-700, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28562414

RESUMO

OBJECTIVES: Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers. MATERIALS AND METHODS: Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported. RESULTS: The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%). CONCLUSIONS: Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.


Assuntos
Ferro/metabolismo , Fígado/diagnóstico por imagem , Fígado/metabolismo , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Adulto Jovem
19.
J Nucl Med ; 52(12): 1923-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22144506

RESUMO

UNLABELLED: A recent survey of pediatric hospitals showed a large variability in the activity administered for diagnostic nuclear medicine imaging of children. Imaging guidelines, especially for pediatric patients, must balance the risks associated with radiation exposure with the need to obtain the high-quality images necessary to derive the benefits of an accurate clinical diagnosis. METHODS: Pharmacokinetic modeling and a pediatric series of nonuniform rational B-spline-based phantoms have been used to simulate (99m)Tc-dimercaptosuccinic acid SPECT images. Images were generated for several different administered activities and for several lesions with different target-to-background activity concentration ratios; the phantoms were also used to calculate organ S values for (99m)Tc. Channelized Hotelling observer methodology was used in a receiver-operating-characteristic analysis of the diagnostic quality of images with different modeled administered activities (i.e., count densities) for anthropomorphic reference phantoms representing two 10-y-old girls with equal weights but different body morphometry. S value-based dosimetry was used to calculate the mean organ-absorbed doses to the 2 pediatric patients. Using BEIR VII age- and sex-specific risk factors, we converted absorbed doses to excess risk of cancer incidence and used them to directly assess the risk of the procedure. RESULTS: Combined, these data provided information about the tradeoff between cancer risk and diagnostic image quality for 2 phantoms having the same weight but different body morphometry. The tradeoff was different for the 2 phantoms, illustrating that weight alone may not be sufficient for optimally scaling administered activity in pediatric patients. CONCLUSION: The study illustrates implementation of a rigorous approach for balancing the benefits of adequate image quality against the radiation risks and also demonstrates that weight-based adjustment to the administered activity is suboptimal. Extension of this methodology to other radiopharmaceuticals would yield the data required to generate objective and well-founded administered activity guidelines for pediatric and other patients.


Assuntos
Diagnóstico por Imagem/efeitos adversos , Neoplasias Induzidas por Radiação/etiologia , Ácido Dimercaptossuccínico Tecnécio Tc 99m/efeitos adversos , Área Sob a Curva , Peso Corporal , Criança , Feminino , Humanos , Modelos Biológicos , Imagens de Fantasmas , Doses de Radiação , Medição de Risco , Ácido Dimercaptossuccínico Tecnécio Tc 99m/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA