Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Acad Radiol ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38614828

RESUMO

RATIONALE AND OBJECTIVES: Neurological complications associated with coronavirus disease (COVID-19) have been reported in children; however, data on neuroimaging findings remain limited. This study aimed to comprehensively examine neuroimaging patterns of COVID-19 in children and their relationship with clinical outcomes. MATERIALS AND METHODS: This retrospective cross-sectional study involved reviewing the medical records and MRI scans of 95 children who developed new neurological symptoms within 2-4 weeks of clinical and laboratory confirmation of COVID-19. Patients were categorized into four groups based on guidelines approved by the Centers for Disease Control and Prevention (CDC). Initial brain/spinal MRI was performed. Images were reviewed by three blinded radiologists, and the findings were analyzed and categorized based on the observed patterns in the brain and spinal cord. Follow-up MRI was performed and analyzed to track lesion progression. RESULTS: Encephalopathy was the most common neurological symptom (50.5%). The most common initial MRI involvement patterns were non-confluent multifocal hyperintense white matter (WM) lesions (36.8%) and ischemia (18.9%). Most patients who underwent follow-up MRI (n = 56) showed complete resolution (69.9%); however, some patients developed encephalomalacia and myelomalacia (23.2% and 7.1%, respectively). Non-confluent hyperintense WM lesions were associated with good outcomes (45.9%, P = 0.014), whereas ischemia and hemorrhage were associated with poor outcomes (44.1%, P < 0.001). CONCLUSION: This study revealed diverse neuroimaging patterns in pediatric COVID-19 patients. Non-confluent WM lesions were associated with good outcomes, whereas ischemia and hemorrhage were associated with poorer prognoses. Understanding these patterns is crucial for their early detection, accurate diagnosis, and appropriate management.

2.
Acad Radiol ; 31(4): 1480-1490, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37914624

RESUMO

RATIONALE AND OBJECTIVES: Recently, a new MRI-based classification for evaluating tibial spine fractures (TSFs) was developed to aid in treating these injuries. Our objective was to assess the detection efficacy, classification accuracy, and reliability of this classification in detecting and grading TSFs, as well as its impact on treatment strategy, compared to the Meyers and McKeever (MM) classification. MATERIALS AND METHODS: A retrospective study included 68 patients with arthroscopically confirmed TSFs. All patients had plain radiography and conventional MRI of the affected knee before arthroscopy. Three experienced radiologists independently reviewed all plain radiographs and MRI data and graded each patient according to MM and MRI-based classifications. The detection efficacy, classification accuracy, and inter-rater agreement of both classifications were evaluated and compared, using arthroscopic findings as the gold standard. RESULTS: The final analysis included 68 affected knees. Compared to the MM classification, the MRI-based classification produced 22.0% upgrade of TSFs and 11.8% downgrade of TSFs. According to the reviewers, the fracture classification accuracy of the MRI-based classification (91.2-95.6%) was significantly higher than that of the MM classification (73.5-76.5%, p = 0.002-0.01). The fracture detection rate of MRI-based classification (94.1-98.5%) was non-significantly higher than that of the MM classification (83.8-89.7%, p = 0.07-0.4). The soft tissue injury detection accuracy for MRI-based classification was 91.2-94.1%. The inter-rater reliability for grading TSFs was substantial for both the MM classification (κ = 0.69) and MRI-based classification (κ = 0.79). CONCLUSION: MRI-based classification demonstrates greater accuracy and reliability compared to MM classification for detecting and grading TSFs and associated soft tissue injuries.


Assuntos
Fraturas do Joelho , Fraturas da Tíbia , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
3.
Eur Radiol ; 34(4): 2500-2511, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37812294

RESUMO

OBJECTIVE: To determine prognostic value of bone marrow retention index (RI-bm) and bone marrow-to-liver ratio (BLR) measured on baseline dual-phase 18F-FDG PET/CT in a series of newly diagnosed patients with diffuse large B-cell lymphoma (DLBCL) treated homogeneously with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP) chemotherapy. PATIENTS AND METHODS: This prospective study enrolled 135 patients with newly diagnosed DLBCL. All patients underwent dual-phase 18F-FDG PET/CT. The following PET parameters were calculated for both tumor and bone marrow: maximum standardized uptake value (SUVmax) at both time points (SUVmax early and SUVmax delayed), SUVmax increment (SUVinc), RI, and BLR. Patients were treated with R-CHOP regimen and response at end of treatment was assessed. RESULTS: The final analysis included 98 patients with complete remission. At a median follow-up of 22 months, 57 patients showed no relapse, 74 survived, and 24 died. The 2-year relapse-free survival (RFS) values for patients with higher and lower RI-bm were 20% and 65.1%, respectively (p < 0.001), and for patients with higher and lower BLR were 30.2% and 69.6%, respectively (p < 0.001). The 2-year overall survival (OS) values for patients with higher and lower RI-bm were 60% and 76.3%, respectively (p = 0.023), and for patients with higher and lower BLR were 57.3% and 78.6%, respectively (p = 0.035). Univariate analysis revealed that RI-bm and BLR were independent significant prognostic factors for both RFS and OS (hazard ratio [HR] = 4.02, p < 0.001, and HR = 3.23, p < 0.001, respectively) and (HR = 2.83, p = 0.030 and HR = 2.38, p = 0.041, respectively). CONCLUSION: Baseline RI-bm and BLR were strong independent prognostic factors in DLBCL patients. CLINICAL RELEVANCE STATEMENT: Bone marrow retention index (RI-bm) and bone marrow-to-liver ratio (BLR) could represent suitable and noninvasive positron emission tomography/computed tomography (PET/CT) parameters for predicting pretreatment risk in patients with newly diagnosed diffuse large B-cell lymphoma (DLBCL) who were treated with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP) chemotherapy. KEY POINTS: • Bone marrow retention index (RI-bm) and bone marrow-to-liver ratio (BLR) are powerful prognostic variables in diffuse large B-cell lymphoma (DLBCL) patients. • High BLR and RI-bm are significantly associated with poor overall survival (OS) and relapse-free survival (RFS). • RI-bm and BLR represent suitable and noninvasive risk indicators in DLBCL patients.


Assuntos
Fluordesoxiglucose F18 , Linfoma Difuso de Grandes Células B , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Prognóstico , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Rituximab/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Prednisona/uso terapêutico , Vincristina/uso terapêutico , Estudos Prospectivos , Recidiva Local de Neoplasia/patologia , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Linfoma Difuso de Grandes Células B/tratamento farmacológico , Linfoma Difuso de Grandes Células B/patologia , Doxorrubicina/uso terapêutico , Ciclofosfamida/uso terapêutico , Fígado/patologia
4.
Eur Radiol ; 33(2): 1286-1296, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35962816

RESUMO

OBJECTIVE: To assess the diagnostic accuracy and agreement of CT and MRI in terms of the Bosniak classification version 2019 (BCv2019). MATERIALS AND METHODS: A prospective multi-institutional study enrolled 63 patients with 67 complicated cystic renal masses (CRMs) discovered during ultrasound examination. All patients underwent CT and MRI scans and histopathology. Three radiologists independently assessed CRMs using BCv2019 and assigned Bosniak class to each CRM using CT and MRI. The final analysis included 60 histopathologically confirmed CRMs (41 were malignant and 19 were benign). RESULTS: Discordance between CT and MRI findings was noticed in 50% (30/60) CRMs when data were analyzed in terms of the Bosniak classes. Of these, 16 (53.3%) were malignant. Based on consensus reviewing, there was no difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT (87.8%; 95% CI = 73.8-95.9% versus 75.6%; 95% CI = 59.7-87.6%; p = 0.09, 84.2%; 95% CI = 60.4-96.6% versus 78.9%; 95% CI = 54.4-93.9%; p = 0.5, and 86.7%; 95% CI = 64.0-86.6% versus 76.7%; 95% CI = 75.4-94.1%; p = 0.1, respectively). The number and thickness of septa and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. The inter-reader agreement (IRA) was substantial for determining the Bosniak class in CT and MRI (k = 0.66; 95% CI = 0.54-0.76, k = 0.62; 95% CI = 0.50-0.73, respectively). The inter-modality agreement of the BCv219 between CT and MRI was moderate (κ = 0.58). CONCLUSION: In terms of BCv2019, CT and MRI are comparable in the classification of CRMs with no significant difference in diagnostic accuracy and reliability. KEY POINTS: • There is no significant difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT. • The number of septa and their thickness and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. • The inter-reader agreement was substantial for determining the Bosniak class in CT and MRI and the inter-modality agreement of the BCv219 between CT and MRI was moderate.


Assuntos
Doenças Renais Císticas , Neoplasias Renais , Humanos , Doenças Renais Císticas/diagnóstico , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Rim/patologia , Estudos Retrospectivos
5.
Int J Gen Med ; 14: 9287-9296, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34880667

RESUMO

PURPOSE: To assess vancomycin paste effect on poststernotomy healing in high-risk coronary artery bypass grafting (CABG) patients compared to bone wax using the 6-point computed tomography (CT) score. Additionally assessed the reliability of this score and its relationship to the occurrence of infection. PATIENTS AND METHODS: A prospective comparative analysis included 126 high-risk CABG patients. The patients were randomly assigned into bone wax or vancomycin paste for sternal haemostasis. All patients were submitted to CT examinations 6-months postoperative. Two radiologists independently reviewed all CT scans to assess sternal healing using the 6-point CT score. The CT healing score of the two groups was compared. The kappa statistics were used to calculate the inter-reader agreement (IRA) of the 6-point CT score. RESULTS: The final analysis included 61 patients in each group. The main CT score for sternal healing was 3.9±0.4 in the vancomycin group and 3.3±0.8 in the bone wax group. Patients in the vancomycin group had a higher statistically significant improvement in CT healing score than those in the bone wax group (p<0.001). There was no statistically significant relationship (p = 0.79) between the occurrence of infection and the 6-point CT score in the vancomycin group. The overall IRA of the 6-point CT score was good in two groups (κ = 0.79 in the vancomycin group and = 0.78 in the bone wax group). CONCLUSION: Vancomycin paste had a better CT healing score and can be used as a sternal haemostatic material instead of bone wax. The 6-point CT healing score is a reliable diagnostic tool for evaluating sternal healing.

6.
Eur J Radiol ; 117: 184-192, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31307646

RESUMO

PURPOSE: To assess diagnostic validity and reproducibility of Thyroid Imaging Reporting and Data System (TI-RADS) for interpretation of thyroid nodules by thyroid ultrasonography (US). METHOD: A prospective multicentre study initially included 557 patients with clinically suspected thyroid nodules. After exclusion, a final cohort of 380 patients with 948 thyroid nodules detected by US were enrolled. Based on American College of Radiology (ACR) TI-RADS, three radiologists analysed all US examinations independently and assigned a TI-RADS category to each thyroid nodule. The final diagnosis was based on cytology which was used as reference standard for calculating diagnostic performance of TI-RADS for predicting malignant thyroid nodules. The Fleiss and weighted kappa (κ) statistics were applied to assess inter-observer agreement of morphological features and TI-RADS scoring results for thyroid nodules. Additionally, we made a simple screening among referring clinicians to assess the clinical response to application of TI-RADS. RESULTS: A total of 948 thyroid nodules were evaluated; 136 (14.3%) were malignant, and 812 (85.7%) were benign. The papillary carcinoma was the most common malignant thyroid nodules (81.6%). The best cut-off value for predicting malignant thyroid nodules was > TR3. On a lesion-based analysis, the TI-RADS had a sensitivity, specificity, and an accuracy of 98.3%, 90.9%, and 92.1%, respectively when regarding those thyroid nodules classified as > TR3 for predicting malignancy. The inter-observer agreement of the TI-RADS category was good (κ = 0.636). Ninety percent of referring clinicians accept TI-RADS. CONCLUSIONS: TI-RADS improves diagnostic performance of US for predicting malignant thyroid nodules with high validity and high reproducibility.


Assuntos
Sistemas de Dados , Sistemas de Informação em Radiologia , Nódulo da Glândula Tireoide/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Padrões de Referência , Reprodutibilidade dos Testes , Adulto Jovem
7.
Eur Radiol ; 29(11): 5981-5990, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30993433

RESUMO

OBJECTIVE: To evaluate diagnostic performance and inter-reviewer agreement (IRA) of the Gynecologic Imaging Reporting and Data System (GI-RADS) for diagnosis of adnexal masses (AMs) by pelvic ultrasound (US). PATIENTS AND METHODS: A prospective multicenter study included 308 women (mean age, 41 ± 12.5 years; range, 15-73 years) with 325 AMs detected by US. All US examinations were analyzed, and AMs were categorized into five categories according to the GI-RADS classification. We used histopathology and US follow-up as the reference standards for calculating diagnostic performance of GI-RADS for detecting malignant AMs. The Fleiss kappa (κ) tests were applied to evaluate the IRA of GI-RADS scoring results for predicting malignant AMs. RESULTS: A total of 325 AMs were evaluated: 127 (39.1%) were malignant and 198 (60.9%) were benign. Of 95 AMs categorized as GI-RADS 2 (GR2), none was malignant; of 94 AMs categorized as GR3, three were malignant; of 13 AMs categorized as GR4, six were malignant; and of 123 AMs categorized as GR5, 118 were malignant. On a lesion-based analysis, the GI-RADS had a sensitivity, a specificity, and an accuracy of 92.9%, 97.5%, and 95.7%, respectively, when regarding only those AMs classified as GR5 for predicting malignancy. Considering combined GR4 and GR5 as a predictor for malignancy, the sensitivity, specificity, and accuracy of GI-RADS were 97.6%, 93.9%, and 95.4%, respectively. The IRA of the GI-RADS category was very good (κ = 0.896). The best cutoff value for predicting malignant AMs was >GR3. CONCLUSIONS: The GI-RADS is very valuable for improving US structural reports. KEY POINTS: • There is still a lack of a standard in the assessment of AMs. • GI-RADS is very valuable for improving US structural reports of AMs. • GI-RADS criteria are easy and work at least as well as IOTA.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Sistemas de Dados , Feminino , Ginecologia , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doenças Ovarianas/diagnóstico por imagem , Estudos Prospectivos , Sistemas de Informação em Radiologia/normas , Padrões de Referência , Projetos de Pesquisa , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA