Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Microsyst Nanoeng ; 10: 56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716376

RESUMO

This paper investigates the fundamental sensing mechanism of electrostatic MEMS gas sensors. It compares among the responsivities of a set of MEMS isopropanol sensors before and after functionalization, and in the presence and absence of electrostatic fields when operated in static and dynamic detection modes. In the static mode, we found that the sensors do not exhibit a measurable change in displacement due to added mass. On the other hand, bare sensors showed a clear change in displacement in response to isopropanol vapor. In the dynamic mode, functionalized sensors showed a measurable frequency shift due to the added mass of isopropanol vapor. In the presence of strong electrostatic fields, the measured frequency shift was found to be threefold larger than that in their absence in response to the same concentration of isopropanol vapor. The enhanced responsivity of dynamic detection allows the sensors to measure the vapor mass captured by the functional material, which is not the case for static detection. The detection of isopropanol by bare sensors in static mode shows that change in the medium permittivity is the primary sensing mechanism. The enhanced responsivity of dynamic mode sensors when operated in strong electrostatic fields shows that their sensing mechanism is a combination of a weaker added mass effect and a stronger permittivity effect. These findings show that electrostatic MEMS gas sensors are independent of the direction of the gravitational field and are, thus, robust to changes in alignment. It is erroneous to refer to them as 'gravimetric' sensors.

2.
Micromachines (Basel) ; 14(9)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37763870

RESUMO

Enhancing the output power of triboelectric nanogenerators (TENGs) requires the creation of micro or nano-features on polymeric triboelectric surfaces to increase the TENGs' effective contact area and, therefore, output power. We deploy a novel bench-top fabrication method called dynamic Scanning Probe Lithography (d-SPL) to fabricate massive arrays of uniform 1 cm long and 2.5 µm wide nano-features comprising a 600 nm deep groove (NG) and a 600 nm high triangular prism (NTP). The method creates both features simultaneously in the polymeric surface, thereby doubling the structured surface area. Six thousand pairs of NGs and NTPs were patterned on a 6×5 cm2 PMMA substrate. It was then used as a mold to structure the surface of a 200 µm thick Polydimethylsiloxane (PDMS) layer. We show that the output power of the nano-structured TENG is significantly more than that of a TENG using flat PDMS films, at 12.2 mW compared to 2.2 mW, under the same operating conditions (a base acceleration amplitude of 0.8 g).

3.
Micromachines (Basel) ; 14(7)2023 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-37512784

RESUMO

Conventional packaging and interconnection methods for two-terminal devices, e.g., diodes often involve expensive and bulky equipment, introduce parasitic effects and have reliability issues. In this study, we propose a built-in packaging method and evaluate its performance compared to probing and wire bonding methods. The built-in packaging approach offers a larger overlap area, improved contact resistance, and direct connection to testing equipment. The experimental results demonstrate a 12% increase in current, an 11% reduction in resistance, and improved performance of the diode. The proposed method is promising for enhancing sensing applications, wireless power transmission, energy harvesting, and solar rectennas. Overall, the built-in packaging method offers a simpler, cheaper, more compact and more reliable packaging solution, paving the way for more efficient and advanced technologies in these domains.

4.
Chaos ; 33(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37276578

RESUMO

We present an experimental technique to construct the response of nonlinear resonators under harmonic excitation as a control parameter is swept. Our technique can resolve nonlinear features in the resonator response, such as bifurcations and hysteresis. To validate it, we construct the frequency response of a MEMS resonator while the excitation frequency is swept. The response is measured optically and recorded in the time domain. The root-mean-square of the response is calculated over a variable-size time-window. The sweep time, window size, and frequency step size were found to be limited by the quality factor of the resonator under test. We examine and describe those limitations in terms of the slew rate and sampling frequency. Although we used optical measurements to validate the technique, the methods described herein are applicable to any measured response signal.

5.
Microsyst Nanoeng ; 9: 58, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37201104

RESUMO

MEMS resonators exhibit rich dynamic behaviors under the internal resonance regime. In this work, we present a novel MEMS bifurcation sensor that exploits frequency unlocking due to a 1:3 internal resonance between two electrostatically coupled micro-resonators. The proposed detection mechanism allows the sensor to operate in binary (digital) and analog modes, depending on whether the sensor merely detects a significant jump event in the peak frequency upon unlocking or measures the shift in the peak frequency after unlocking and uses it in conjunction with a calibration curve to estimate the corresponding change in stimulus. We validate the success of this sensor paradigm by experimentally demonstrating charge detection. High charge resolutions are achieved in binary mode, up to 0.137 fC, and in analog mode, up to 0.01 fC. The proposed binary sensor enables extraordinarily high detection resolutions due to the excellent frequency stability under internal resonance and the high signal-to-noise ratio of the shift in peak frequency. Our findings offer new opportunities for high-performance ultrasensitive sensors.

6.
Sensors (Basel) ; 22(24)2022 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-36560058

RESUMO

We investigate the rich potential of the multi-modal motions of electrostatically actuated asymmetric arch microbeams to design higher sensitivity and signal-to-noise ratio (SNR) inertial gas sensors. The sensors are made of fixed-fixed microbeams with an actuation electrode extending over one-half of the beam span in order to maximize the actuation of asymmetry. A nonlinear dynamic reduced-order model of the sensor is first developed and validated. It is then deployed to investigate the design of sensors that exploit the spatially complex and dynamically rich motions that arise due to veering and modal hybridization between the first symmetric and the first anti-symmetric modes of the beam. Specifically, we compare among the performance of four sensors implemented on a common platform using four detection mechanisms: classical frequency shift, conventional bifurcation, modal ratio, and differential capacitance. We find that frequency shift and conventional bifurcation sensors have comparable sensitivities. On the other hand, modal interactions within the veering range and modal hybridization beyond it offer opportunities for enhancing the sensitivity and SNR of bifurcation-based sensors. One method to achieve that is to use the modal ratio between the capacitances attributed to the symmetric and asymmetric modes as a detector, which increases the detection signal by three orders of magnitude compared to a conventional bifurcation sensor. We also present a novel sensing mechanism that exploits a rigid arm extending transversely from the arch beam mid-point and placed at equal distances between two side electrodes. It uses the asymmetry of the arch beam motions to induce rotary motions and realize a differential sensor. It is found to increase the detection signal by two orders of magnitude compared to a conventional bifurcation sensor.

7.
Sensors (Basel) ; 22(14)2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35890942

RESUMO

An alternative packaging method, termed built-in packaging, is proposed for single terminal devices, and demonstrated with an actuator application. Built-in packaging removes the requirements of wire bonding, chip carrier, PCB, probe station, interconnection elements, and even wires to drive single terminal devices. Reducing these needs simplifies operation and eliminates possible noise sources. A micro resonator device is fabricated and built-in packaged for demonstration with electrostatic actuation and optical measurement. Identical actuation performances are achieved with the most conventional packaging method, wire bonding. The proposed method offers a compact and cheap packaging for industrial and academic applications.

8.
Sensors (Basel) ; 22(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35684724

RESUMO

We report on the deployment of MEMS static bifurcation (DC) sensors for the detection of volatile organic compounds (VOCs): hydrogen sulfide and formaldehyde. We demonstrate a sensor that can detect as low as a few ppm of hydrogen sulfide. We also demonstrate a sensor array that can selectively detect formaldehyde in the presence of benzene, a closely related interferent. Toward that end, we investigate the sensitivity and selectivity of two detector polymers-polyaniline (PANI) and poly (2,5-dimethyl aniline) (P25DMA)-to both gases. A semiautomatic method is developed to functionalize individual sensors and sensor arrays with the detector polymers. We found that the sensor array can selectively sense 1 ppm of formaldehyde in the presence of benzene.


Assuntos
Sulfeto de Hidrogênio , Sistemas Microeletromecânicos , Compostos Orgânicos Voláteis , Benzeno , Formaldeído , Polímeros
9.
Nano Lett ; 22(8): 3196-3203, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35404606

RESUMO

A resonant microcantilever sensor is fabricated from a zinc oxide (ZnO) thin film, which serves as both the structural and sensing layers. An open-air spatial atomic layer deposition technique is used to deposit the ZnO layer to achieve a ∼200 nm thickness, an order of magnitude lower than the thicknesses of conventional microcantilever sensors. The reduction in the number of layers, in the cantilever dimensions, and its overall lower mass lead to an ultrahigh sensitivity, demonstrated by detection of low humidity levels. A maximum sensitivity of 23649 ppm/% RH at 5.8% RH is observed, which is several orders of magnitude larger than those reported for other resonant humidity sensors. Furthermore, the ZnO cantilever sensor is self-actuated in air, an advantageous detection mode that enables simpler and lower-power-consumption sensors.


Assuntos
Óxido de Zinco , Umidade , Óxido de Zinco/química
10.
ACS Appl Mater Interfaces ; 14(3): 4119-4131, 2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35025196

RESUMO

Despite advances in the development of individual nanogenerators, the level of output energy generation must be increased to meet the demands of commercial electronic systems and to broaden their scope of application. To harvest low-frequency ambient mechanical energy more efficiently, we proposed a highly integrated hybridized piezoelectric-triboelectric-electromagnetic (tristate) nanogenerator in a uniaxial structure. In its highly integrated approach, a piezoelectric nanogenerator (PENG) based on CsPbBr3 (cesium lead bromide) nanoparticles (NPs) and poly(dimethylsiloxane) (PDMS) nanocomposite was fabricated on a triboelectrically negative nanostructured polyimide (PI) substrate. A cylindrical aluminum electrode grooved with permanent magnets was directed to move along a spring-less metallic guide bounded by these nanocomposites, thus essentially forming two single-electrode mode triboelectric nanogenerators (TENGs). By its optimized material design and novel integration approach of the PENGs, TENGs, and electromagnetic generators (EMGs), this uniaxial tristate hybrid nanogenerator (UTHNG) can synergistically produce an instantaneous electrical power of 49 mW at low-frequency ambient vibration (5 Hz). The UTHNG has excellent charging characteristics, ramping up the output voltage of a 22 µF capacitor to 2.7 V in only 12 s, which is much faster than individual nanogenerators. This work will be a superior solution for harvesting low-frequency ambient energies by improving the performance of hybrid nanogenerators, potentially curtailing the technology gap for self-powered micro/nanosystems for the Internet of Things.

11.
Biomed Opt Express ; 13(11): 5643-5653, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36733742

RESUMO

Optically shifting the focal plane to allow depth scanning of delicate biological structures and processes in their natural environment offers an appealing alternative to conventional mechanical scanning. Our technique uses a deformable mirror-based photoacoustic remote sensing microscopy (PARS) with a focus shifting of Δz ∼ 240 µm. We achieve this by integrating a deformable mirror that functions as a varifocal mirror for axial scanning. First, the system's focal shift capability was demonstrated with USAF resolution targets and carbon fiber phantoms, followed by in-vivo visualizations of blood vessels in chicken embryo chorioallantoic membrane (CAM). This work represents an initial step toward developing a non-contact, label-free, and aberration-free PARS imaging system with axial scanning capability.

12.
Sensors (Basel) ; 21(21)2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34770660

RESUMO

Inertial Motion Capture (IMC) systems enable in situ studies of human motion free of the severe constraints imposed by Optical Motion Capture systems. Inverse dynamics can use those motions to estimate forces and moments developing within muscles and joints. We developed an inverse dynamic whole-body model that eliminates the usage of force plates (FPs) and uses motion patterns captured by an IMC system to predict the net forces and moments in 14 major joints. We validated the model by comparing its estimates of Ground Reaction Forces (GRFs) to the ground truth obtained from FPs and comparing predictions of the static model's net joint moments to those predicted by 3D Static Strength Prediction Program (3DSSPP). The relative root-mean-square error (rRMSE) in the predicted GRF was 6% and the intraclass correlation of the peak values was 0.95, where both values were averaged over the subject population. The rRMSE of the differences between our model's and 3DSSPP predictions of net L5/S1 and right and left shoulder joints moments were 9.5%, 3.3%, and 5.2%, respectively. We also compared the static and dynamic versions of the model and found that failing to account for body motions can underestimate net joint moments by 90% to 560% of the static estimates.


Assuntos
Fenômenos Mecânicos , Músculos , Fenômenos Biomecânicos , Humanos , Movimento (Física)
13.
Sensors (Basel) ; 21(7)2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33918268

RESUMO

We developed a new technique for the detection of shear horizontal surface acoustic waves (SH-SAW) using a one-dimensional laser-based Doppler vibrometer. It measures the out-of-plane surface deformation at the fingertip of an interdigitated transducer (the boundary of the wave aperture) and uses it to estimate the instantaneous in-plane displacement field given the substrate Poisson ratio. It can also estimate the degree of surface confinement (wave decay rate). The proposed approach was first verified using finite element analysis (FEA) and demonstrated experimentally using a Bleustein-Gulyaev resonator.

14.
Sensors (Basel) ; 20(21)2020 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-33172192

RESUMO

This work presents an approach to delay-based reservoir computing (RC) at the sensor level without input modulation. It employs a time-multiplexed bias to maintain transience while utilizing either an electrical signal or an environmental signal (such as acceleration) as an unmodulated input signal. The proposed approach enables RC carried out by sufficiently nonlinear sensory elements, as we demonstrate using a single electrostatically actuated microelectromechanical system (MEMS) device. The MEMS sensor can perform colocalized sensing and computing with fewer electronics than traditional RC elements at the RC input (such as analog-to-digital and digital-to-analog converters). The performance of the MEMS RC is evaluated experimentally using a simple classification task, in which the MEMS device differentiates between the profiles of two signal waveforms. The signal waveforms are chosen to be either electrical waveforms or acceleration waveforms. The classification accuracy of the presented MEMS RC scheme is found to be over 99%. Furthermore, the scheme is found to enable flexible virtual node probing rates, allowing for up to 4× slower probing rates, which relaxes the requirements on the system for reservoir signal sampling. Finally, our experiments show a noise-resistance capability for our MEMS RC scheme.

15.
ACS Appl Mater Interfaces ; 12(42): 47503-47512, 2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-32969216

RESUMO

In the modern era, structural health monitoring (SHM) is critically important and indispensable in the aerospace industry as an effective measure to enhance the safety and consistency of aircraft structures by deploying a reliable sensor network. The deployment of built-in sensor networks enables uninterrupted structural integrity monitoring of an aircraft, providing crucial information on operation condition, deformation, and potential damage to the structure. Sustainable and durable piezoelectric nanogenerators (PENGs) with good flexibility, high performance, and superior reliability are promising candidates for powering wireless sensor networks, particularly for aerospace SHM applications. This research demonstrates a self-powered wireless sensing system based on a porous polyvinylidene fluoride (PVDF)-based PENG, which is prominently anticipated for developing auto-operated sensor networks. Our reported porous PVDF film is made from a flexible piezoelectric polymer (PVDF) and inorganic zinc oxide (ZnO) nanoparticles. The fabricated porous PVDF-based PENG demonstrates ∼11 times and ∼8 times enhancement of output current and voltage, respectively, compared to a pure PVDF-based PENG. The porous PVDF-based PENG can produce a peak-to-peak short-circuit current of 22 µA, a peak-to-peak open-circuit voltage of 84.5 V, a peak output power of 0.46 mW (P=Voc2×Isc2), and a peak output power density of 41.02 µW/cm2 (P/A). By harnessing energy from minute vibrations, the fabricated porous PVDF-based PENG device (area of A = 11.33 cm2) can generate sufficient electrical energy to power up a customized wireless sensing and communication unit and transfer sensor data every ∼4 min. The PENG can generate sufficient electrical energy from an automobile car vibration, which reflects the scenario of potential real-life SHM systems. We anticipate that this high-performance porous PVDF-based PENG can act as a reliable power source for the sensor networks in aircraft, which minimizes potential safety risks.

16.
Sensors (Basel) ; 20(12)2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32630484

RESUMO

We report a technique to measure in-plane and out-of-plane motions of MEMS using typical out-of-plane (single-axis) Laser Doppler Vibrometers (LDVs). The efficacy of the technique is demonstrated by evaluating the in-plane and out-of-plane modal response and frequency response of an interdigitated comb-drive actuator. We also investigate the validity of observing planar modes of vibration outside their dominant plane of motion and find that it leads to erroneous results. Planar modes must be evaluated in their plan of motion.

17.
Materials (Basel) ; 13(1)2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31861779

RESUMO

Cellular polypropylene (PP) has been recently used in energy harvesting applications. In this work, we investigate its viability and long-term stability under various operating conditions. Specifically, the effect of constant stress and stress cycling on output power and long-term stability of ferroelectret energy harvesters is analyzed. Our findings show that after 112 days constant stress significantly increases the piezoelectric charge constant d 33 and output power from 0.51 µW for a stress-free harvester to 2.71 µW. It also increases the harvester center frequency from 450 to 700 Hz and decreases its optimal resistance from 7 to 5.5 M Ω .

18.
Materials (Basel) ; 11(4)2018 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-29673194

RESUMO

Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

19.
Sensors (Basel) ; 17(5)2017 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-28505097

RESUMO

We experimentally investigate the primary superharmonic of order two and subharmonic of order one-half resonances of an electrostatic MEMS actuator under direct excitation. We identify the parameters of a one degree of freedom (1-DOF) generalized Duffing oscillator model representing it. The experiments were conducted in soft vacuum to reduce squeeze-film damping, and the actuator response was measured optically using a laser vibrometer. The predictions of the identified model were found to be in close agreement with the experimental results. We also identified the noise spectral density of process (actuation voltage) and measurement noise.

20.
J Biomech Eng ; 139(3)2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27925635

RESUMO

A novel application of phase-space warping (PSW) method to detect fatigue in the musculoskeletal system is presented. Experimental kinematic, force, and physiological signals are used to produce a fatigue metric. The metric is produced using time-delay embedding and PSW methods. The results showed that by using force and kinematic signals, an overall estimate of the muscle group state can be achieved. Further, when using electromyography (EMG) signals the fatigue metric can be used as a tool to evaluate muscles activation and load sharing patterns for individual muscles. The presented method will allow for fatigue evolution measurement outside a laboratory environment, which open doors to applications such as tracking the physical state of players during competition, workers in a plant, and patients undergoing in-home rehabilitation.


Assuntos
Eletromiografia , Fadiga Muscular , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA