Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38978826

RESUMO

Background: Vascular endothelial growth factor (VEGF) is the primary substance involved in retinal barrier breach. VEGF overexpression may cause diabetic macular edema (DME). Laser photocoagulation of the macula is the standard treatment for DME; however, recently, intravitreal anti-VEGF injections have surpassed laser treatment. Our aim was to evaluate the efficacy of intravitreal injections of aflibercept or ranibizumab for managing treatment-naive DME. Methods: This single-center, retrospective, interventional, comparative study included eyes with visual impairment due to treatment-naive DME that underwent intravitreal injection of either aflibercept 2 mg/0.05 mL or ranibizumab 0.5 mg/0.05 mL at Al-Azhar University Hospitals, Egypt between March 2023 and January 2024. Demographic data and full ophthalmological examination results at baseline and 1, 3, and 6 months post-injection were collected, including the best-corrected distance visual acuity (BCDVA) in logarithm of the minimum angle of resolution (logMAR) notation, slit-lamp biomicroscopy, dilated fundoscopy, and central subfield thickness (CST) measured using spectral-domain optical coherence tomography. Results: Overall, the 96 eyes of 96 patients with a median (interquartile range [IQR]) age of 57 (10) (range: 20-74) years and a male-to-female ratio of 1:2.7 were allocated to one of two groups with comparable age, sex, diabetes mellitus duration, and presence of other comorbidities (all P >0.05). There was no statistically significant difference in baseline diabetic retinopathy status or DME type between groups (both P >0.05). In both groups, the median (IQR) BCDVA significantly improved from 0.7 (0.8) logMAR at baseline to 0.4 (0.1) logMAR at 6 months post-injection (both P = 0.001), with no statistically significant difference between groups at all follow-up visits (all P >0.05). The median (IQR) CST significantly decreased in the aflibercept group from 347 (166) µm at baseline to 180 (233) µm at 6 months post-injection, and it decreased in the ranibizumab group from 360 (180) µm at baseline to 190 (224) µm at 6 months post-injection (both P = 0.001), with no statistically significant differences between groups at all follow-up visits (all P >0.05). No serious adverse effects were documented in either group. Conclusions: Ranibizumab and aflibercept were equally effective in achieving the desired anatomical and functional results in patients with treatment-naïve DME in short-term follow-up without significant differences in injection counts between both drugs. Larger prospective, randomized, double-blinded trials with longer follow-up periods are needed to confirm our preliminary results.

2.
Sci Rep ; 14(1): 16553, 2024 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-39019963

RESUMO

The traditional methods in early caries detection had many limitations. So, this study aimed to evaluate the clinical performance of alternating current impedance spectroscopy ACIST in comparison with digital radiograph and ICDAS-II in detection of occlusal carious lesions. Occlusal surfaces of molar and premolar teeth from 40 adult participants were examined by two observers using three diagnostic methods: (1) international caries detection and assessment system (ICDAS-II) (2) digital radiograph (DR) and (3) Cariescan Pro device (ACIST). Agreement analysis and the difference in sensitivities and specificities were evaluated. The results showed an excellent agreement in the different groups. The difference from the visual tactile against ACIST scoring for enamel caries detection, was statistically significant (p = 0.012) and the agreement was moderate (k = 0.509). For dentinal caries the difference was not statistically significant (p > 0.05) and the agreement was similarly moderate (k < 0.6). The difference from the digital radiograph against ACIST scoring, for enamel caries, digital radiography had significantly higher sensitivity and specificity than ACIST (p < 0.001) while for dentinal caries detection and overall, ACIST had higher sensitivity and digital radiography had higher specificity and the difference was statistically significant (p < 0.001). Visual-tactile examination is a considered as feasible and valid technique for occlusal caries detection, digital radiography is superior to ACIST in diagnosing enamel caries, but it could underestimate the caries depth, ACIST is a reliable tool for detecting occlusal caries in dentin.


Assuntos
Cárie Dentária , Espectroscopia Dielétrica , Radiografia Dentária Digital , Humanos , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/diagnóstico , Adulto , Masculino , Feminino , Radiografia Dentária Digital/métodos , Estudos Prospectivos , Espectroscopia Dielétrica/métodos , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Adulto Jovem , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Pessoa de Meia-Idade
3.
Nanoscale ; 16(16): 7937-7950, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38545684

RESUMO

Li-air battery (LAB) technology is making continuous progress toward its theoretical capacity, which is comparable to gasoline. However, the sluggish reaction at the cathode is still a challenge. We propose a simple strategy to optimize the surface eg occupancy by adjusting the stoichiometric ratios of transition metal-based spinel structures through a controlled hydrothermal synthesis. Three distinct stoichiometries of Ni-Co oxides were used to demonstrate the direct correlation between stoichiometry and catalytic performance. The groundsel flower-like structure having a 1 : 1.4 Ni : Co atomic ratio with high surface area, high defect density, and an abundance of Ni3+ at the surface with semi-filled eg orbitals was found to benefit the structure promoting high catalytic activities in aqueous and aprotic media. The assembled LAB cells employing this cathode demonstrate an exceptional lifespan, operating for 3460 hours and completing 173 cycles while achieving the highest discharge capacity of 13 759 mA h g-1 and low charging overpotentials. The key to this prolonged performance lies in the full reversibility of the cell, attributed to its excellent OER performance. A well-surface adsorbed, amorphous LiO2/Li2O2 discharge product is found to possess high diffusivity and ease of decomposition, contributing significantly to the enhanced longevity of the cell.

4.
Adv Mater ; 36(23): e2313273, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38533901

RESUMO

The rapid growth of electric vehicle use is expected to cause a significant environmental problem in the next few years due to the large number of spent lithium-ion batteries (LIBs). Recycling spent LIBs will not only alleviate the environmental problems but also address the challenge of limited natural resources shortages. While several hydro- and pyrometallurgical processes are developed for recycling different components of spent batteries, direct regeneration presents clear environmental, and economic advantages. The principle of the direct regeneration approach is restoring the electrochemical performance by healing the defective structure of the spent materials. Thus, the development of direct regeneration technology largely depends on the formation mechanism of defects in spent LIBs. This review systematically details the degradation mechanisms and types of defects found in diverse cathode materials, graphite anodes, and current collectors during the battery's lifecycle. Building on this understanding, principles and methodologies for directly rejuvenating materials within spent LIBs are outlined. Also the main challenges and solutions for the large-scale direct regeneration of spent LIBs are proposed. Furthermore, this review aims to pave the way for the direct regeneration of materials in discarded lithium-ion batteries by offering a theoretical foundation and practical guidance.

5.
ACS Appl Mater Interfaces ; 16(5): 5847-5856, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38284621

RESUMO

The rational design of cost-effective and efficient electrocatalysts for electrochemical water splitting is essential for green hydrogen production. Utilizing nanocatalysts with abundant active sites, high surface area, and deliberate stacking faults is a promising approach for enhancing catalytic efficiency. In this study, we report a simple strategy to synthesize a highly efficient electrocatalyst for the hydrogen evolution reaction (HER) using carbonized luffa cylindrica as a conductive N-doped carbon skeleton decorated with Ag nanorings that are activated by introducing stacking faults. The introduction of stacking faults and the resulting tensile strain into the Ag nanorings results in a significant decrease in the HER overpotential, enabling the use of Ag as an efficient HER electrocatalyst. Our findings demonstrate that manipulating the crystal properties of electrocatalysts, even for materials with intrinsically poor catalytic activity such as Ag, can result in highly efficient catalysts. Further, applying a conductive carbon backbone can lower the quantities of metal needed without compromising the HER activity. This approach opens up new avenues for designing high-performance electrocatalysts with very low metallic content, which could significantly impact the development of sustainable and cost-effective electrochemical water-splitting systems.

6.
Arq. bras. oftalmol ; 86(3): 223-231, May 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1439379

RESUMO

ABSTRACT Purpose: To compare viscotrabeculotomy with anterior chamber irrigation to Ahmed glaucoma valve implantation for secondary glaucoma following silicone oil removal. Methods: A prospective study was conducted on 43 vitrectomized pseudophakic eyes with persistent glaucoma after silicone oil removal. Patients were randomized to either viscotrabeculotomy with anterior chamber irrigation or Ahmed glaucoma valve implantation. All patients were examined on day 1, week 1, and months 1, 3, 6, 9, 12, 18, and 24 postoperatively. Postoperative complications were noted. Success was defined as an intraocular pressure between 6 and 20 mmHg and with an intraocular pressure reduction of >30% compared with the preoperative intraocular pressure. Results: There were 22 eyes in the viscotrabeculotomy with anterior chamber irrigation and 21 eyes in the Ahmed glaucoma valve implantation group. The mean preoperative and postoperative intraocular pressure in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 35.5 ± 2.6 mmHg and 35.5 ± 2.4 mmHg and 16.9 ± 0.7 mmHg and 17.9 ± 0.9 mmHg respectively (p˂0.0001). There was a statistically significant intraocular pressure reduction at all follow-up time points compared to preoperative values (p˂0.0001) in both groups. The unqualified success rate in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 72.73% and 61.9%, respectively. A minimal self-limited hyphema was the most common complication. Conclusions: Both viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation are effective in lowering the intraocular pressure in glaucoma after silicone oil removal with viscotrabeculotomy with anterior chamber irrigation providing greater reduction, higher success rates, and minimal complications.


RESUMO Objetivo: Comparar a viscotrabeculotomia com irrigação da câmara anterior com o implante de válvula de glaucoma de Ahmed para glaucoma secundário após remoção de óleo de silicone. Métodos: Foi realizado um estudo prospectivo de 43 olhos pseudofácicos vitrectomizados com glaucoma persistente após a remoção de óleo de silicone. Os pacientes foram randomizados para viscotrabeculotomia com irrigação da câmara anterior ou implante de válvula de Ahmed. Todos os pacientes foram examinados no primeiro dia, na primeira semana e 1, 3, 6, 9, 12, 18 e 24 meses após a cirurgia. Observaram-se complicações pós-operatórias. O sucesso foi definido como uma pressão intraocular entre 6 e 20 mmHg e uma redução da pressão intraocular >30% em comparação com a pressão intraocular pré-operatória. Resultados: Foram designados 22 olhos para o grupo da viscotrabeculotomia com irrigação da câmara anterior e 21 olhos para o grupo do implante de válvula de Ahmed. A pressão intraocular média pré-operatória foi de 35,5 ± 2,6 mmHg para o grupo da viscotrabeculotomia com irrigação da câmara anterior e pós- e de 35,5 ± 2,4 mmHg no grupo do implante de válvula de Ahmed. e Os valores pós-ope­ratórios foram de 16,9 ± 0,7 mmHg e 17,9 ± 0,9 mmHg para esses mesmos grupos, respectivamente (p<0,0001). Ambos os grupos tiveram uma redução estatisticamente significativa da pressão intraocular em relação aos valores pré-operatórios (p<0,0001) em todos os momentos do acompanhamento. A taxa de sucesso não qualificado nos grupos da viscotrabeculotomia com irrigação da câmara anterior e do implante de válvula de Ahmed foi de 72,73% e 61,9%, respectivamente. A complicação mais comum foi o hifema, autolimitado e mínimo. Conclusões: Tanto a viscotrabeculotomia com irrigação da câmara anterior quanto o implante de válvula de Ahmed são eficazes na redução da pressão intraocular no glaucoma após injeção de óleo de silicone, mas a viscotrabeculotomia com irrigação em câmara anterior proporcionou maior redução da pressão intraocular e maiores taxas de sucesso, com complicações mínimas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA