Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.562
Filtrar
1.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38436451

RESUMO

Solid-state nuclear track detectors (SSNTDs) are often used as ion detectors in laser-driven ion acceleration experiments and are considered to be the most reliable ion diagnostics since they are sensitive only to ions and measure ions one by one. However, ion pit analyses require tremendous time and effort in chemical etching, microscope scanning, and ion pit identification by eyes. From a laser-driven ion acceleration experiment, there are typically millions of microscopic images, and it is practically impossible to analyze all of them by hand. This research aims to improve the efficiency and automation of SSNTD analyses for laser-driven ion acceleration. We use two sets of data obtained from calibration experiments with a conventional accelerator where ions with known nuclides and energies are generated and from actual laser experiments using SSNTDs. After chemical etching and scanning the SSNTDs with an optical microscope, we use machine learning to distinguish the ion etch pits from noises. From the results of the calibration experiment, we confirm highly accurate etch-pit detection with machine learning. We are also able to detect etch pits with machine learning from the laser-driven ion acceleration experiment, which is much noisier than calibration experiments. By using machine learning, we successfully identify ion etch pits ∼105 from more than 10 000 microscopic images with a precision of ≳95%. A million microscopic images can be examined with a recent entry-level computer within a day with high precision. Machine learning tremendously reduces the time consumption on ion etch pit analyses detected on SSNTDs.

2.
Phys Rev Lett ; 131(9): 092502, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37721815

RESUMO

We successfully performed electron scattering off unstable nuclei which were produced online from the photofission of uranium. The target ^{137}Cs ions were trapped with a new target-forming technique that makes a high-density stationary target from a small number of ions by confining them in an electron storage ring. After developments of target generation and transportation systems and the beam stacking method to increase the ion beam intensity up to approximately 2×10^{7} ions per pulse beam, an average luminosity of 0.9×10^{26} cm^{-2} s^{-1} was achieved for ^{137}Cs. The obtained angular distribution of elastically scattered electrons is consistent with a calculation. This success marks the realization of the anticipated femtoscope which clarifies the structures of exotic and short-lived unstable nuclei.

3.
Radiat Res ; 199(6): 535-555, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310880

RESUMO

Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0-1 Gy), moderately exposed (1-2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5-10 h of receipt for GE, gH2AX, LUM, EPR, 2-3 days for DCA, CBMN and within 6-7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0-1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89-100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0-50% or 0-48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29-76%) and 3.5 Gy (17-100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2-6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.


Assuntos
Bioensaio , Coleta de Amostras Sanguíneas , Estudos Retrospectivos , Citocinese , Espectroscopia de Ressonância de Spin Eletrônica
5.
Radiat Res ; 199(6): 583-590, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057978

RESUMO

Translocation analysis using fluorescence in situ hybridization (FISH) is the method of choice for dose assessment in case of chronic or past exposures to ionizing radiation. Although it is a widespread technique, unlike dicentrics, the number of FISH-based inter-laboratory comparisons is small. For this reason, although the current Running the European Network of Biological and Physical retrospective Dosimetry (RENEB) inter-laboratory comparison 2021 was designed as a fast response to a real emergency scenario, it was considered a good opportunity to perform an inter-laboratory comparison using the FISH technique to gain further experience. The Bundeswehr Institute of Radiobiology provided peripheral blood samples from one healthy human volunteer. Three test samples were irradiated with blinded doses of 0, 1.2, and 3.5 Gy, respectively. Samples were then sent to the seven participating laboratories. The FISH technique was applied according to the standard procedure of each laboratory. Both, the frequency of translocations and the estimated dose for each sample were sent to the coordinator using a special scoring sheet for FISH. All participants sent their results in due time. However, although it was initially requested to send the results based on the full analysis, evaluating 500 equivalent cells, most laboratories only sent the results based on triage, with a smaller number of analyzed cells. In the triage analysis, there was great heterogeneity in the number of equivalent cells scored. On the contrary, for the full analysis, this number was more homogeneous. For all three samples, one laboratory showed outlier yields compared to the other laboratories. Excluding these results, in the triage analysis, the frequency of translocations in sample no. 1 ranged from 0 to 0.013 translocations per cell, and for samples no. 2 and no. 3 the genomic mean frequency were 0.27 ± 0.03 and 1.47 ± 0.14, with a coefficient of variation of 0.29 and 0.23 respectively. Considering only results obtained in the triage analysis for sample no. 1, all laboratories, except one, classified this sample as the non-irradiated one. For sample no. 2, excluding the outlier value, the mean reported dose was 1.74 ± 0.16 Gy indicating a mean deviation of about 0.5 Gy to the delivered dose of 1.2 Gy. For sample no. 3 the mean dose estimated was 4.21 ± 0.21 Gy indicating a mean deviation of about 0.7 Gy to the delivered dose of 3.5 Gy. In the frame of RENEB, this is the second FISH-based inter-laboratory comparison. The whole exercise was planned as a response to an emergency, therefore, a triage analysis was requested for all the biomarkers except for FISH. Although a full analysis was initially requested for FISH, most of the laboratories reported only a triage-based result. The main reason is that it was not clearly stated what was required before starting the exercise. Results show that most of the laboratories successfully discriminated unexposed and irradiated samples from each other without any overlap. A good agreement in the observed frequencies of translocations was observed but there was a tendency to overestimate the delivered doses. Efforts to improve the harmonization of this technique and subsequent exercises to elucidate the reason for this trend should be promoted.


Assuntos
Radiometria , Translocação Genética , Humanos , Hibridização in Situ Fluorescente/métodos , Estudos Retrospectivos , Radiometria/métodos , Bioensaio/métodos , Aberrações Cromossômicas
6.
Rev Sci Instrum ; 93(11): 113530, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461420

RESUMO

Particle counting analysis is a possible way to characterize GeV-scale, multi-species ions produced in laser-driven experiments. We present a multi-layered scintillation detector to differentiate multi-species ions of different masses and energies. The proposed detector concept offers potential advantages over conventional diagnostics in terms of (1) high sensitivity to GeV ions, (2) realtime analysis, and (3) the ability to differentiate ions with the same charge-to-mass ratio. A novel choice of multiple scintillators with different ion stopping powers results in a significant difference in energy deposition between the scintillators, allowing accurate particle identification in the GeV range. Here, we report a successful demonstration of particle identification for heavy ions, performed at the Heavy Ion Medical Accelerator in Chiba. In the experiment, the proposed detector setup showed the ability to differentiate particles with similar atomic numbers, such as C6+ and O8+ ions, and provided an excellent energy resolution of 0.41%-1.2% (including relativistic effect, 0.51%--1.6%).

7.
Surg Case Rep ; 8(1): 220, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36484868

RESUMO

BACKGROUND: Follicular dendritic cell sarcoma is a rare stromal tumor with no standard treatment. However, some reports have revealed that follicular dendritic cell sarcoma has an inflammatory pseudotumor variant associated with Epstein-Barr virus infection that has a relatively good prognosis. In this report, we present a case of a resected inflammatory pseudotumor variant of follicular dendritic cell sarcoma of the liver, and have reviewed the literature on the clinicopathological, molecular, and genomic features of this tumor. CASE PRESENTATION: The inflammatory pseudotumor variant of follicular dendritic cell sarcoma originates only in the liver or spleen, causes no symptoms, and is more common in middle-aged Asian women. It has no characteristic imaging features, which partially explains why the inflammatory pseudotumor variant of follicular dendritic cell sarcoma is difficult to diagnose. Pathologically, the inflammatory pseudotumor variant of follicular dendritic cell sarcoma has spindle cells mixed with inflammatory cells and is variably positive for follicular dendritic cell markers (CD21, CD23, and CD35) and Epstein-Barr virus-encoded RNA. On genetic analysis, patients with this tumor high levels of latent membrane protein 1 gene expression and extremely low levels of host C-X-C Chemokine Receptor type 7 gene expression, indicating that the inflammatory pseudotumor variant of follicular dendritic cell sarcoma has a latent Epstein-Barr virus type 2 infection. CONCLUSIONS: The inflammatory pseudotumor variant of follicular dendritic cell sarcoma is an Epstein-Barr virus-associated tumor and a favorable prognosis by surgical resection, similar to Epstein-Barr virus-associated gastric cancer.

8.
Phys Rev E ; 106(4-2): 045211, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36397600

RESUMO

A strong quasistationary magnetic field is generated in hollow targets with curved internal surface under the action of a relativistically intense picosecond laser pulse. Experimental data evidence the formation of quasistationary strongly magnetized plasma structures decaying on a hundred picoseconds timescale, with the magnetic field strength of the kilotesla scale. Numerical simulations unravel the importance of transient processes during the magnetic field generation and suggest the existence of fast and slow regimes of plasmoid evolution depending on the interaction parameters. The proposed setup is suited for perspective highly magnetized plasma application and fundamental studies.

9.
Rev Sci Instrum ; 93(9): 093523, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182514

RESUMO

Bright, short-pulsed neutron beams from laser-driven neutron sources (LANSs) provide a new perspective on material screening via fast neutron activation analysis (FNAA). FNAA is a nondestructive technique for determining material elemental composition based on nuclear excitation by fast neutron bombardment and subsequent spectral analysis of prompt γ-rays emitted by the active nuclei. Our recent experiments and simulations have shown that activation analysis can be used in practice with modest neutron fluences on the order of 105 n/cm2, which is available with current laser technology. In addition, time-resolved γ-ray measurements combined with picosecond neutron probes from LANSs are effective in mitigating the issue of spectral interference between elements, enabling highly accurate screening of complex samples containing many elements. This paper describes the predictive capability of LANS-based activation analysis based on experimental demonstrations and spectral calculations with Monte Carlo simulations.

11.
Sci Rep ; 12(1): 13734, 2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-35962017

RESUMO

Optical generation of kilo-tesla scale magnetic fields enables prospective technologies and fundamental studies with unprecedentedly high magnetic field energy density. A question is the optimal configuration of proposed setups, where plenty of physical phenomena accompany the generation and complicate both theoretical studies and experimental realizations. Short laser drivers seem more suitable in many applications, though the process is tangled by an intrinsic transient nature. In this work, an artificial neural network is engaged for unravelling main features of the magnetic field excited with a picosecond laser pulse. The trained neural network acquires an ability to read the magnetic field values from experimental data, extremely facilitating interpretation of the experimental results. The conclusion is that the short sub-picosecond laser pulse may generate a quasi-stationary magnetic field structure living on a hundred picosecond time scale, when the induced current forms a closed circuit.

12.
Rev Sci Instrum ; 93(6): 063502, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778001

RESUMO

Particle counting analysis (PCA) with a multi-stage scintillation detector shows a new perspective on angularly resolved spectral characterization of GeV-scale, multi-species ion beams produced by high-power lasers. The diagnosis provides a mass-dependent ion energy spectrum based on time-of-flight and pulse-height analysis of single particle events detected through repetitive experiments. With a novel arrangement of multiple scintillators with different ions stopping powers, PCA offers potential advantages over commonly used diagnostic instruments (CR-39, radiochromic films, Thomson parabola, etc.) in terms of coverage solid angle, detection efficiency for GeV-ions, and real-time analysis during the experiment. The basic detector unit was tested using 230-MeV proton beam from a synchrotron facility, where we demonstrated its potential ability to discriminate major ion species accelerated in laser-plasma experiments (i.e., protons, deuterons, carbon, and oxygen ions) with excellent energy and mass resolution. The proposed diagnostic concept would be essential for a better understanding of laser-driven particle acceleration, which paves the way toward all-optical compact accelerators for a range of applications.

13.
Front Bioeng Biotechnol ; 10: 884271, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35721843

RESUMO

Urine is an attractive biospecimen for in vitro diagnostics, and urine-based lateral flow assays are low-cost devices suitable for point-of-care testing, particularly in low-resource settings. However, some of the lateral flow assays exhibit limited diagnostic utility because the urinary biomarker concentration is significantly lower than the assay detection limit, which compromises the sensitivity. To address the challenge, we developed an osmotic processor that statically and spontaneously concentrated biomarkers. The specimen in the device interfaces with the aqueous polymer solution via a dialysis membrane. The polymer solution induces an osmotic pressure difference that extracts water from the specimen, while the membrane retains the biomarkers. The evaluation demonstrated that osmosis induced by various water-soluble polymers efficiently extracted water from the specimens, ca. 5-15 ml/h. The osmotic processor concentrated the specimens to improve the lateral flow assays' detection limits for the model analytes-human chorionic gonadotropin and SARS-CoV-2 nucleocapsid protein. After the treatment via the osmotic processor, the lateral flow assays detected the corresponding biomarkers in the concentrated specimens. The test band intensities of the assays with the concentrated specimens were very similar to the reference assays with 100-fold concentrations. The mass spectrometry analysis estimated the SARS-CoV-2 nucleocapsid protein concentration increased ca. 200-fold after the osmosis. With its simplicity and flexibility, this device demonstrates a great potential to be utilized in conjunction with the existing lateral flow assays for enabling highly sensitive detection of dilute target analytes in urine.

14.
Phys Rev Lett ; 128(15): 152701, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35499908

RESUMO

The Rare-RI Ring (R3) is a recently commissioned cyclotronlike storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Isotope Beam Factory (RIBF) in RIKEN. The first application of mass measurement using the R3 mass spectrometer at RIBF is reported. Rare isotopes produced at RIBF-^{127}Sn, ^{126}In, ^{125}Cd, ^{124}Ag, ^{123}Pd-were injected in R3. Masses of ^{126}In, ^{125}Cd, and ^{123}Pd were measured whereby the mass uncertainty of ^{123}Pd was improved. This is the first reported measurement with a new storage ring mass spectrometry technique realized at a heavy-ion cyclotron and employing individual injection of the preidentified rare nuclei. The latter is essential for the future mass measurements of the rarest isotopes produced at RIBF. The impact of the new ^{123}Pd result on the solar r-process abundances in a neutron star merger event is investigated by performing reaction network calculations of 20 trajectories with varying electron fraction Y_{e}. It is found that the neutron capture cross section on ^{123}Pd increases by a factor of 2.2 and ß-delayed neutron emission probability, P_{1 n}, of ^{123}Rh increases by 14%. The neutron capture cross section on ^{122}Pd decreases by a factor of 2.6 leading to pileup of material at A=122, thus reproducing the trend of the solar r-process abundances. The trend of the two-neutron separation energies (S_{2n}) was investigated for the Pd isotopic chain. The new mass measurement with improved uncertainty excludes large changes of the S_{2n} value at N=77. Such large increase of the S_{2n} values before N=82 was proposed as an alternative to the quenching of the N=82 shell gap to reproduce r-process abundances in the mass region of A=112-124.

15.
Sci Rep ; 12(1): 6876, 2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35477961

RESUMO

High energy density physics is the field of physics dedicated to the study of matter and plasmas in extreme conditions of temperature, densities and pressures. It encompasses multiple disciplines such as material science, planetary science, laboratory and astrophysical plasma science. For the latter, high energy density states can be accompanied by extreme radiation environments and super-strong magnetic fields. The creation of high energy density states in the laboratory consists in concentrating/depositing large amounts of energy in a reduced mass, typically solid material sample or dense plasma, over a time shorter than the typical timescales of heat conduction and hydrodynamic expansion. Laser-generated, high current-density ion beams constitute an important tool for the creation of high energy density states in the laboratory. Focusing plasma devices, such as cone-targets are necessary in order to focus and direct these intense beams towards the heating sample or dense plasma, while protecting the proton generation foil from the harsh environments typical of an integrated high-power laser experiment. A full understanding of the ion beam dynamics in focusing devices is therefore necessary in order to properly design and interpret the numerous experiments in the field. In this work, we report a detailed investigation of large-scale, kilojoule-class laser-generated ion beam dynamics in focusing devices and we demonstrate that high-brilliance ion beams compress magnetic fields to amplitudes exceeding tens of kilo-Tesla, which in turn play a dominant role in the focusing process, resulting either in a worsening or enhancement of focusing capabilities depending on the target geometry.

16.
Sci Rep ; 12(1): 2346, 2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35173182

RESUMO

Graphene is known as an atomically thin, transparent, highly electrically and thermally conductive, light-weight, and the strongest 2D material. We investigate disruptive application of graphene as a target of laser-driven ion acceleration. We develop large-area suspended graphene (LSG) and by transferring graphene layer by layer we control the thickness with precision down to a single atomic layer. Direct irradiations of the LSG targets generate MeV protons and carbons from sub-relativistic to relativistic laser intensities from low contrast to high contrast conditions without plasma mirror, evidently showing the durability of graphene.

18.
Rev Sci Instrum ; 92(6): 063301, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243550

RESUMO

A dosimetric calibration of three types of radiochromic films (GafChromicTM HD-V2, MD-V3, and EBT3) was carried out for absorbed doses (D) ranging up to 100 kGy using a 130 TBq Co60 γ-ray source. The optical densities (ODs) of the irradiated films were acquired with the transmission-mode flatbed film scanner EPSON GT-X980. The calibration data were cross-checked using the 20-MeV proton beam from the azimuthally varying field cyclotron at the Research Center for Nuclear Physics in Osaka University. These experimental results not only present the measurable dose ranges of the films depending on the readout wavelength, but also show consistency with our hypothesis that the OD response curve [log(OD)-log(D) curve] is determined by the volumetric average of the absorption dose and does not strongly depend on the type of radiation for the excitation.

19.
Phys Rev E ; 103(5-1): 053202, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34134285

RESUMO

In an experiment performed with a high-intensity and high-energy laser system, α-particle production in proton-boron reaction by using a laser-driven proton beam was measured. α particles were observed from the front and also from the rear side, even after a 2-mm-thick boron target. The data obtained in this experiment have been analyzed using a sequence of numerical simulations. The simulations clarify the mechanisms of α-particle production and transport through the boron targets. α-particle energies observed in the experiment and in the simulation reach 10-20 MeV through energy transfer from 20-30 MeV energy incident protons. Despite the lower cross sections for protons with energy above the sub-MeV resonances in the proton-boron reactions, 10^{8}-10^{9}α particles per steradian have been detected.

20.
J Neuroradiol ; 48(4): 311-315, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31563590

RESUMO

BACKGROUND AND PURPOSE: Precise vessel measurement plays a major role in size selection of stents used for the treatment of intracranial aneurysms and became even more critical after the introduction of flow diverter stents. We assessed agreement between intracranial vessel diameters of aneurysm patients measured on 2D digital subtraction (2D DSA) and 3D volume rendering digital subtraction angiography (3D DSA) images using an automatic windowing algorithm. MATERIALS AND METHODS: Ten patients with intracranial aneurysms were enrolled and 120 measurement points were selected on both 2D and 3D DSA images acquired by a biplane angiographic system. Automatic windowing was applied to the 3D DSA images. Inter-method agreement of vessel measurements on 2D and 3D DSA images was assessed by Bland Altman plots and intraclass correlation coefficients (ICC). Inter- and intra-rater agreement of measurements on 3D DSA images were assessed by ICCs. RESULTS: The mean differences between measurements on 2D and 3D DSA images were 0.14mm for the ICA, and 0.18mm for the ACA and MCA, which is about the size of one 3D DSA image voxel. For ICA measurements, inter-method, inter-rater and intra-rater agreements were good or excellent (consistency and absolute ICC≥0.95). For ACA and MCA measurements, the inter-method, inter-rater and intra-rater agreements were also good or excellent (consistency ICC=0.94, 0.89 and 0.93, absolute ICC=0.83, 0.84 and 0.85 respectively). CONCLUSIONS: Vessel diameters may be measured on 3D DSA images with sufficient reliability for clinical use when applying an automatic windowing algorithm.


Assuntos
Aneurisma Intracraniano , Algoritmos , Angiografia Digital , Angiografia Cerebral , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA