Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Adv Prosthodont ; 8(5): 333-338, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27826382

RESUMO

PURPOSE: The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth. MATERIALS AND METHODS: 168 artificial tooth specimens were divided into the following four subgroups (n=42): SR Orthotyp PE (polymethylmethacrylate); SR Orthosit PE (Isosit); SR Postaris DCL (double cross-linked); and SR Phonares II (nanohybrid composite). The specimens were further divided according to the type of the denture cleanser (Corega Tabs (sodium perborate), sodium hypochlorite (NaOCl), and distilled water (control) (n=14)) and immersed in the cleanser to simulate a 180-day immersion period, after which the surface roughness and microhardness were tested. The data were analyzed using the Kruskal-Wallis test, Conover's nonparametric multiple comparison test, and Spearman's rank correlation analysis (P<.05). RESULTS: A comparison among the denture cleanser groups showed that NaOCl caused significantly higher roughness values on SR Orthotyp PE specimens when compared with the other artificial teeth (P<.001). Furthermore, Corega Tabs resulted in higher microhardness values in SR Orthotyp PE specimens than distilled water and NaOCl (P<.005). The microhardness values decreased significantly from distilled water, NaOCl, to Corega Tabs for SR Orthosit PE specimens (P<.001). SR Postaris DLC specimens showed increased microhardness when immersed in distilled water or NaOCl when compared with immersion in Corega Tabs (P<.003). No correlation was found between surface roughness and microhardness (r=0.104, P=.178). CONCLUSION: NaOCl and Corega Tabs affected the surface roughness and microhardness of all artificial denture teeth except for the new generation nanohybrid composite teeth.

2.
J Prosthet Dent ; 115(1): 71-5, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26386483

RESUMO

STATEMENT OF PROBLEM: The color stainability of recently introduced computer-assisted design/computer-assisted manufacturing (CAD/CAM) hybrid ceramic and resin nanoceramic is unknown. PURPOSE: The purpose of this in vitro study was to compare the effect of coffee staining on the color of 3 different CAD/CAM restorative materials and a nanocomposite resin. MATERIAL AND METHODS: Specimens from a hybrid dental ceramic (VITA Enamic), a resin nanoceramic (Lava Ultimate), a lithium disilicate glass ceramic (IPS e.max CAD), and a nanocomposite resin (Filtek Supreme Ultra Universal) were evaluated for color change due to thermocycling in coffee (n=5). Specimens 0.5 to 0.7 mm and 1 to 1.2 mm in thickness were thermocycled for 5000 cycles. CIEDE2000 color differences (ΔE00) due to thermocycling in coffee were calculated using the color coordinates obtained from a spectroradiometer. ANCOVA was used to analyze the color differences among the materials with thickness as the covariate. Significant differences at average thickness were analyzed with the Tukey-Kramer test. RESULTS: For color difference due to staining, thickness was a significant covariate (P<.001). Regarding the analysis of color differences, every pair of the tested materials was significantly different (P<.001). Least squares means of color differences (ΔE00) at mean thickness were 4.34 for the nanohybrid composite resin, 3.66 for the resin nanoceramic, 1.35 for the hybrid ceramic, and 0.43 for the lithium disilicate ceramic. CONCLUSION: When exposed to hot and cold coffee, the color change was beyond clinical acceptability for the tested resin nanoceramic and nanocomposite resin materials. The average color change of the hybrid ceramic was clinically perceivable over the tested thickness values. The color change of lithium disilicate ceramic was not clinically perceivable at any tested thickness.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Nanocompostos , Cor , Teste de Materiais
3.
Int J Clin Exp Med ; 8(1): 1453-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25785154

RESUMO

Wernicke's encephalopathy (WE) is a disease classically associated with nutrition deficiency. It is characterized by typical symptoms like confusion, ataxia and ophthalmoparesis, and developes due to thiamine deficieny in alcoholic patients. Recently, it has been shown that WE could ocur in patients with gastric carcinoma without a history of alcohol use. In this paper, we have made some suggestions about early diagnosis, treatment and prevention of WE by discussing the development of WE in a patient with unresectable gastric carcinoma, who had been inpatient for a long time and given radiotherapy and chemotherapy.

4.
J Prosthet Dent ; 112(4): 949-56, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24939254

RESUMO

STATEMENT OF PROBLEM: Different techniques have been suggested for cleaning dentin surfaces after the removal of an interim prosthesis and before the application of a bonding agent. How different surface-cleaning techniques affect the bond strength of the composite resin restorations is not clear. PURPOSE: The purpose of this study was to investigate the effects of different surface-cleaning techniques on the bond strength of composite resin restorations and the surface topography of the prepared tooth surfaces. MATERIAL AND METHODS: The occlusal surfaces of 25 molars were ground until the dentin was exposed. A bonding agent and interim cement were applied on the teeth. The teeth were divided into 5 groups (n=5) according to the method used for surface-cleaning (microairborne-particle abrasion, alcohol, rubber-rotary instrument, desiccating agent, and control). Once the surfaces of the teeth had been cleaned, the same bonding material was applied to the teeth. A 5-mm-thick composite resin layer was built up. Each specimen was sectioned to microbars, and 6 centrally located beams were selected for microtensile testing (n=30) (1.10 ±0.10 mm). The data were statistically analyzed with 1-way ANOVA (1-sample Kolmogorov-Smirnov test). The Bonferroni test was used for significantly different groups (α=.05). One specimen from each group was observed under a scanning electron microscope and an atomic force microscope. Energy dispersive x-ray analysis also was performed. RESULTS: Bond strength values were in the following descending order: microairborne-particle abrasion, desiccating agent, alcohol, rubber-rotary instrument, control. Differences between the microairborne-particle abrasion group and the remainder of the groups, desiccating agent--rubber-rotary instrument, desiccating agent-control, alcohol--rubber-rotary instrument, and alcohol-control groups, were statistically significant (P<.05). The microairborne-particle abrasion group displayed the roughest surface and a different surface topography from the remainder of the groups. Increased aluminum was observed in the microairborne-particle abrasion group. CONCLUSIONS: Surface-cleaning techniques, except for the rubber-rotary instrument, increased the bond strength of composite resin. The roughest dentin surfaces and highest bond strength were achieved with the microairborne-particle abrasion technique.


Assuntos
Abrasão Dental por Ar/métodos , Resinas Compostas/química , Colagem Dentária , Corrosão Dentária/métodos , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Adulto , Abrasão Dental por Ar/instrumentação , Cimentos Dentários/química , Corrosão Dentária/instrumentação , Dentina/ultraestrutura , Etanol/química , Humanos , Higroscópicos/química , Teste de Materiais , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Dente Molar/ultraestrutura , Cimentos de Resina/química , Borracha/química , Autocura de Resinas Dentárias , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Adulto Jovem , Óxido de Zinco/química
5.
J Adv Prosthodont ; 6(2): 88-95, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24843392

RESUMO

PURPOSE: The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS: Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA) 2) Aqua-Prep F-(Fluoride), 3) Bisblock-(Oxalate), 4) Cervitec Plus-(Clorhexidine), 5) Smart protect-(Triclosan), 6) Nd:YAG laser, 7) No treatment (control). After applying the selected agent, RelyX U200 self-adhesive resin cement was used to bond composite resin blocks to dentin. All groups were subjected to thermocycling for 1000 cycles between 5-55℃. Each bonded specimen was sectioned to microbars (6 mm × 1 mm × 1 mm) (n=20). Specimens were submitted to microtensile bond strength test at a crosshead speed of 0.5 mm/min. Kolmogorov-Smirnov, Levene's test, Kruskal-Wallis One-way Analysis of Variance, and Conover's nonparametric statistical analysis were used (P<.05). RESULTS: Gluma, Smart Protect and Nd:YAG laser treatments showed comparable microtensile bond strengths compared with the control group (P>.05). The microtensile bond strengths of Aqua-Prep F, and Cervitec Plus were similar to each other but significantly lower than the control group (P<.05). Bisblock showed the lowest microtensile bond strength among all groups (P<.001). Most groups showed adhesive failure. CONCLUSION: Within the limitation of this study, it is not recommended to use Aqua-prep F, Cervitec Plus and Bisblock on dentin when used with a self-adhesive resin cement due to the decrease they cause in bond strength. Beside, pre-treatment of dentin with Gluma, Smart protect, and Nd:YAG laser do not have a negative effect.

6.
J Prosthet Dent ; 111(5): 388-94, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24360008

RESUMO

STATEMENT OF PROBLEM: It is not clear whether newly introduced cordless displacement systems are better able to manage gingiva than conventional systems. PURPOSE: The purpose of this in vivo study was to evaluate the gingival management ability of 4 different displacement methods with a standardized subgingival preparation finish line. MATERIAL AND METHODS: The effects of 4 displacement techniques on gingival management and impression quality were evaluated by means of 6 evaluation criteria. A subgingival preparation finish line of between 1 and 2 mm was ensured, and the buccal aspects of 252 (n=63) teeth were clinically assessed for ease of application, time spent, bleeding, remnants, and dilatation. The complete reproduction of the preparation finish line and the bubble and void formations on polyether impressions were also evaluated. The data were statistically analyzed with the χ(2) test (α=.05). The Bonferroni correction was used to control Type I error for the pairwise comparison groups (α=.008). RESULTS: Statistically significant differences were found for all criteria among the groups (P<.05). The nonimpregnated displacement cord group was the least effective group in terms of bleeding and impression quality (P<.008). The aluminum chloride impregnated cord group and the displacement paste with cap group were found to be comparable in terms of remnants, dilatation, and impression quality (P>.008). The retraction cap with paste group showed better results for ease of application, time spent, and bleeding than the aluminum chloride impregnated cord group (P<.008). Although the group with aluminum chloride impregnated cord, displacement paste, and cap showed better results for dilatation, it was time consuming and difficult (P<.008). CONCLUSIONS: Except for the nonimpregnated cord group, all of the groups were comparable and clinically useful, with perfect or acceptable impression qualities.


Assuntos
Gengiva/anatomia & histologia , Técnicas de Retração Gengival , Cloreto de Alumínio , Compostos de Alumínio/uso terapêutico , Adstringentes/uso terapêutico , Cloretos/uso terapêutico , Coroas , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica/normas , Prótese Parcial Fixa , Dilatação/métodos , Éteres/química , Gengiva/efeitos dos fármacos , Hemorragia Gengival/etiologia , Técnicas de Retração Gengival/instrumentação , Técnicas de Retração Gengival/normas , Hemostáticos/uso terapêutico , Humanos , Estudos Prospectivos , Fatores de Tempo , Preparo Prostodôntico do Dente/métodos
7.
J Prosthet Dent ; 108(2): 102-13, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22867807

RESUMO

STATEMENT OF PROBLEM: It is not clear whether more hydrophilic impression materials are better able to copy and transfer dentin surface detail than less hydrophilic ones. PURPOSE: The purpose of this study was to evaluate the reproduction of dentin surface detail by means of hydrophobic and hydrophilic elastomeric impression materials under simulated pulpal pressure and their ability to transfer surface detail onto casts produced from such impressions. MATERIAL AND METHODS: The wettability of the impression materials (n=8) was determined by contact angle measurement with an evolution period of 135 seconds. Dentin moisture was provided by means of pulpal pressure simulation, and objective analyses were performed by measuring the average roughness value (Ra) with a 3-D optical profilometer (n=10). One specimen from each group was analyzed with scanning electron microscopy. Contact-angle values were analyzed with a repeated measures ANOVA, and detail reproduction was tested with 3-way ANOVA (α=.05). The Bonferroni correction was used to control Type I error for follow-up analyses. RESULTS: Contact angle measurements revealed significant differences depending on the impression material used and time of the measurement (P<.001). The Ra values of the hydrophilic impression materials, which were made from dry specimens, and the pulpal pressure simulated dentin surfaces did not differ from the dentin surfaces (P>.013). The hydrophobic impression material showed similar detail reproduction ability in a dry field, but loss of detail (evaluated subjectively) and increased roughness values (evaluated objectively) were recorded in a moisturized field (P=.004). Polyurethane-based cast material successfully reproduced the surface texture (P≥.006), whereas Type IV gypsum material was unable to reproduce this texture to the same extent. CONCLUSIONS: The hydrophilic impression materials tested showed similar ability to reproduce detail under simulated pulpal pressure. Polyurethane-based cast material successfully reproduced the surface texture.


Assuntos
Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Adaptação Marginal Dentária , Dentina/ultraestrutura , Modelos Dentários , Análise de Variância , Humanos , Imageamento Tridimensional , Resinas Sintéticas/química , Silicones/química , Propriedades de Superfície , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA