1.
Phys Imaging Radiat Oncol ; 27: 100451, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37720464

RESUMO

Background and purpose: A brain tumour, especially a glioma, is a rare disease; it is challenging to treat and the prognosis is often poor. Routine care includes surgery and concomitant chemoradiotherapy (CRT). Diagnostic work-up and treatment effects are typically evaluated using magnetic resonance imaging (MRI). Quantitative MRI (qMRI), unlike conventional MRI, has the advantage of providing tissue-specific relaxation rates and proton density. The purpose is to detect changes in normal appearing white matter (NAWM) in brain tumour patients after CRT using qMRI. Materials & methods: NAWM was analysed in 10 patients, in 83 MR examinations performed before and after surgery and after CRT. Relaxation rates R1 and R2, the proton density (PD) and the concentration of myelin (cMy) were calculated from the qMRI scans and analysed in correlation to radiation dose and time after treatment. Results: A significant decrease in cMy between pre-treatment imaging and first follow-up and an increase in PD were observed. For low doses (less than 30 Gy) PD and cMy returned to baseline (=pre-operative status), while for high doses (>30 Gy) the change increased during the full extent of the follow-up period. No difference could be established for R1. For R2 an increase was observed during the first year, which then gradually returned to baseline. For R2, stronger effects were seen as a consequence of higher absorbed doses. Conclusion: In the long-term follow-up for glioma patients, qMRI is a powerful tool for detecting small changes, such as a decrease of myelin concentration, in NAWM after CRT.

2.
Acta Oncol ; 58(12): 1731-1739, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31423867

RESUMO

Introduction: Within an International Atomic Energy Agency (IAEA) co-ordinated research project (CRP), a remote end-to-end dosimetric quality audit for intensity modulated radiation therapy (IMRT)/ volumetric arc therapy (VMAT) was developed to verify the radiotherapy chain including imaging, treatment planning and dose delivery. The methodology as well as the results obtained in a multicentre pilot study and national trial runs conducted in close cooperation with dosimetry audit networks (DANs) of IAEA Member States are presented.Material and methods: A solid polystyrene phantom containing a dosimetry insert with an irregular solid water planning target volume (PTV) and organ at risk (OAR) was designed for this audit. The insert can be preloaded with radiochromic film and four thermoluminescent dosimeters (TLDs). For the audit, radiotherapy centres were asked to scan the phantom, contour the structures, create an IMRT/VMAT treatment plan and irradiate the phantom. The dose prescription was to deliver 4 Gy to the PTV in two fractions and to limit the OAR dose to a maximum of 2.8 Gy. The TLD measured doses and film measured dose distributions were compared with the TPS calculations.Results: Sixteen hospitals from 13 countries and 64 hospitals from 6 countries participated in the multicenter pilot study and in the national runs, respectively. The TLD results for the PTV were all within ±5% acceptance limit for the multicentre pilot study, whereas for national runs, 17 participants failed to meet this criterion. All measured doses in the OAR were below the treatment planning constraint. The film analysis identified seven plans in national runs below the 90% passing rate gamma criteria.Conclusion: The results proved that the methodology of the IMRT/VMAT dosimetric end-to-end audit was feasible for its intended purpose, i.e., the phantom design and materials were suitable; the phantom was easy to use and it was robust enough for shipment. Most importantly the audit methodology was capable of identifying suboptimal IMRT/VMAT delivery.


Assuntos
Auditoria Médica/métodos , Órgãos em Risco , Imagens de Fantasmas , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos de Viabilidade , Humanos , Agências Internacionais , Auditoria Médica/normas , Energia Nuclear , Projetos Piloto , Garantia da Qualidade dos Cuidados de Saúde , Radiometria/normas , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/normas , Tomografia Computadorizada por Raios X
3.
Radiat Prot Dosimetry ; 186(1): 119-122, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30929009

RESUMO

The aim of this study was to test two different solid state dosimetry systems for the purpose of end-to-end audits of radiotherapy volumetric modulated arc therapy (VMAT) technique; a lithium formate electron paramagnetic resonance system and a lithium fluoride thermoluminescent dosimetry system. As a complement to the solid state systems, ion chamber measurements were performed. A polystyrene phantom with a planning target volume (PTV) and an organ at risk (OAR) structure was scanned using CT. A VMAT dose plan was optimized to deliver 2 Gy to the target volume and to minimize the dose to the OAR. The different detectors were inserted into the phantom and the planned dose distribution was delivered. The measured doses were compared to the treatment planning system (TPS) calculated doses. Good agreement was found between the TPS calculated and the measured doses, well accepted for the dose determinations in remote dosimetry audits of VMAT treatment technique.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Formiatos/efeitos da radiação , Neoplasias/radioterapia , Imagens de Fantasmas , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/métodos , Formiatos/química , Humanos , Processamento de Imagem Assistida por Computador/métodos , Medições Luminescentes , Neoplasias/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
4.
Phys Med Biol ; 60(9): 3869-82, 2015 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-25906141

RESUMO

Interest in high dose rate (HDR) electronic brachytherapy operating at 50 kV is increasing. For quality assurance it is important to identify dosimetry systems that can measure the absorbed doses in absolute terms which is difficult in this energy region. In this work a comparison is made between two dosimetry systems, EPR lithium formate dosimeters and radiochromic EBT2 film. Both types of dosimeters were irradiated simultaneously in a PMMA phantom using the Axxent EBS. Absorbed dose to water was determined at distances of 10 mm, 30 mm and 50 mm from the EBS. Results were traceable to different primary standards as regards to absorbed dose to water (EPR) and air kerma (EBT2). Monte Carlo simulations were used in absolute terms as a third estimate of absorbed dose to water. Agreement within the estimated expanded (k = 2) uncertainties (5% (EPR), 7% (EBT2)) was found between the results at 30 mm and 50 mm from the x-ray source. The same result was obtained in 4 repetitions of irradiation, indicating high precision in the measurements with both systems. At all distances, agreement between EPR and Monte Carlo simulations was shown as was also the case for the film measurements at 30mm and 50mm. At 10mm the geometry for the film measurements caused too large uncertainty in measured values depending on the exact position (within sub-mm distances) of the EBS and the 10 mm film results were exculded from comparison. This work has demonstrated good performance of the lithium formate EPR dosimetry system in accordance with earlier experiments at higher photon energies ((192)Ir HDR brachytherapy). It was also highlighted that there might be issues regarding the energy dependence and intrinsic efficiency of the EBT2 film that need to be considered for measurements using low energy sources.


Assuntos
Braquiterapia/instrumentação , Eletrônica Médica , Fótons , Monitoramento de Radiação/instrumentação , Braquiterapia/métodos , Formiatos/química , Monitoramento de Radiação/métodos , Água/química , Raios X
5.
Radiother Oncol ; 113(2): 279-82, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25475838

RESUMO

The aim of this work was to develop and test a remote end-to-end audit system using lithium formate EPR dosimeters. Four clinics were included in a pilot study, absorbed doses determined in the PTV agreed with TPS calculated doses within ±5% for 3D-CRT and ±7% (k=1) for IMRT/VMAT dose plans.


Assuntos
Formiatos/química , Radioterapia de Intensidade Modulada/métodos , Radioterapia/métodos , Imageamento Tridimensional , Projetos Piloto , Radiometria , Radioterapia/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação
6.
Phys Med Biol ; 57(8): 2209-17, 2012 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-22456424

RESUMO

The aim of this study was to investigate signal fading in lithium formate electron paramagnetic resonance (EPR) dosimeters used for clinical applications in radiotherapy. A new experimental method for determination of signal fading, designed to resolve small changes in signal from slowly decaying unstable radicals, was used. Possible signal fading in lithium formate due to different storage temperatures was also tested. Air humidity was kept at a constant level of 33% throughout the experiments. The conclusion drawn from the investigations was that the EPR signal from lithium formate is stable during at least 1 month after irradiation and is not sensitive to variations in storage temperature <40 °C when kept at a relative air humidity of 33%. This makes lithium formate a suitable dosimeter for transfer dosimetry in clinical audits.


Assuntos
Artefatos , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Formiatos , Radiometria/métodos , Temperatura , Fatores de Tempo
7.
Med Phys ; 37(9): 4946-59, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20964214

RESUMO

PURPOSE: To investigate experimentally the energy dependence of the detector response of lithium formate EPR dosimeters for photon energies below 1 MeV relative to that at 60Co energies. High energy photon beams are used in calibrating dosimeters for use in brachytherapy since the absorbed dose to water can be determined with high accuracy in such beams using calibrated ion chambers and standard dosimetry protocols. In addition to any differences in mass-energy absorption properties between water and detector, variations in radiation yield (detector response) with radiation quality, caused by differences in the density of ionization in the energy imparted (LET), may exist. Knowledge of an eventual deviation in detector response with photon energy is important for attaining high accuracy in measured brachytherapy dose distributions. METHODS: Lithium formate EPR dosimeters were irradiated to known levels of air kerma in 25-250 kV x-ray beams and in 137Cs and 60Co beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free in air into values of mean absorbed dose to the detectors were made using EGSnrc MC simulations and x-ray energy spectra measured or calculated for the actual beams. The signals from the detectors were measured using EPR spectrometry. Detector response (the EPR signal per mean absorbed dose to the detector) relative to that for 60Co was determined for each beam quality. RESULTS: Significant decreases in the relative response ranging from 5% to 6% were seen for x-ray beams at tube voltages < or = 180 kV. No significant reduction in the relative response was seen for 137Cs and 250 kV x rays. CONCLUSIONS: When calibrated in 60Co or MV photon beams, corrections for the photon energy dependence of detector response are needed to achieve the highest accuracy when using lithium formate EPR dosimeters for measuring absorbed doses around brachytherapy sources emitting photons in the energy range of 20-150 keV such as 169Yb and electronic sources.


Assuntos
Braquiterapia/métodos , Formiatos , Fótons , Radiometria/métodos , Espectroscopia de Ressonância de Spin Eletrônica , Incerteza