Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Environ Res ; 260: 119524, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38972338

RESUMO

This review offers a detailed examination of the current landscape of radio frequency (RF) electromagnetic field (EMF) assessment tools, ranging from spectrum analyzers and broadband field meters to area monitors and custom-built devices. The discussion encompasses both standardized and non-standardized measurement protocols, shedding light on the various methods employed in this domain. Furthermore, the review highlights the prevalent use of mobile apps for characterizing 5G NR radio network data. A growing need for low-cost measurement devices is observed, commonly referred to as "sensors" or "sensor nodes", that are capable of enduring diverse environmental conditions. These sensors play a crucial role in both microenvironmental surveys and individual exposures, enabling stationary, mobile, and personal exposure assessments based on body-worn sensors, across wider geographical areas. This review revealed a notable need for cost-effective and long-lasting sensors, whether for individual exposure assessments, mobile (vehicle-integrated) measurements, or incorporation into distributed sensor networks. However, there is a lack of comprehensive information on existing custom-developed RF-EMF measurement tools, especially in terms of measuring uncertainty. Additionally, there is a need for real-time, fast-sampling solutions to understand the highly irregular temporal variations EMF distribution in next-generation networks. Given the diversity of tools and methods, a comprehensive comparison is crucial to determine the necessary statistical tools for aggregating the available measurement data.

2.
Sensors (Basel) ; 24(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38793866

RESUMO

In this presented study, we measured in situ the uplink duty cycles of a smartphone for 5G NR and 4G LTE for a total of six use cases covering voice, video, and data applications. The duty cycles were assessed at ten positions near a 4G and 5G base-station site in Belgium. For Twitch, VoLTE, and WhatsApp, the duty cycles ranged between 4% and 22% in time, both for 4G and 5G. For 5G NR, these duty cycles resulted in a higher UL-allotted time due to time division duplexing at the 3.7 GHz frequency band. Ping showed median duty cycles of 2% for 5G NR and 50% for 4G LTE. FTP upload and iPerf resulted in duty cycles close to 100%.

3.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991856

RESUMO

Of particular interest within fifth generation (5G) cellular networks are the typical levels of radiofrequency (RF) electromagnetic fields (EMFs) emitted by 'small cells', low-power base stations, which are installed such that both workers and members of the general public can come in close proximity with them. In this study, RF-EMF measurements were performed near two 5G New Radio (NR) base stations, one with an Advanced Antenna System (AAS) capable of beamforming and the other a traditional microcell. At various positions near the base stations, with distances ranging between 0.5 m and 100 m, both the worst-case and time-averaged field levels under maximized downlink traffic load were assessed. Moreover, from these measurements, estimates were made of the typical exposures for various cases involving users and non-users. Comparison to the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) resulted in maximum exposure ratios of 0.15 (occupational, at 0.5 m) and 0.68 (general public, at 1.3 m). The exposure of non-users was potentially much lower, depending on the activity of other users serviced by the base station and its beamforming capabilities: 5 to 30 times lower in the case of an AAS base station compared to barely lower to 30 times lower for a traditional antenna.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Humanos , Exposição Ambiental , Ondas de Rádio/efeitos adversos
4.
Sensors (Basel) ; 23(6)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36992024

RESUMO

This paper compares different low-cost sensors that can measure (5G) RF-EMF exposure. The sensors are either commercially available (off-the-shelf Software Defined Radio (SDR) Adalm Pluto) or constructed by a research institution (i.e., imec-WAVES, Ghent University and Smart Sensor Systems research group (S³R), The Hague University of Applied Sciences). Both in-lab (GTEM cell) and in-situ measurements have been performed for this comparison. The in-lab measurements tested the linearity and sensitivity, which can then be used to calibrate the sensors. The in-situ testing confirmed that the low-cost hardware sensors and SDR can be used to assess the RF-EMF radiation. The variability between the sensors was 1.78 dB on average, with a maximum deviation of 5.26 dB. Values between 0.09 V/m and 2.44 V/m were obtained at a distance of about 50 m from the base station. These devices can be used to provide the general public and governments with temporal and spatial 5G electromagnetic field values.

5.
Radiat Prot Dosimetry ; 198(6): 358-369, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35511688

RESUMO

New measurement methods and equipment for correct 5G New Radio (NR) electromagnetic field (EMF) in-situ exposure assessment of instantaneous time-averaged exposure (Eavg) and maximum extrapolated field exposure (Emax) are proposed. The different options are investigated with in-situ measurements around 5G NR base stations (FR1) in different countries. The maximum electric field values satisfy the ICNIRP 2020 limit (maximum 7.7%). The difference between Emax and Eavg is <3 dB for the different measurement equipment at multiple sites in case there is only self-generated traffic. However, in a more realistic scenario, Eavg cannot be used to assess the exposure correctly due to influence of other users as the spatial distribution of user equipment (UE) influences Eavg, while Emax is not affected. However, when multiple UEs are collocated, there is no influence of the number of UEs. A broadband measurement can give a first impression of the RF-EMF exposure up to 700 m, but is not enough to assess the 5G-NR exposure.


Assuntos
Telefone Celular , Ondas de Rádio , Eletricidade , Campos Eletromagnéticos , Exposição Ambiental
6.
Sensors (Basel) ; 22(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35270862

RESUMO

In an increasingly wireless world, spatiotemporal monitoring of the exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) is crucial to appease public uncertainty and anxiety about RF-EMF. However, although the advent of smart city infrastructures allows for dense networks of distributed sensors, the costs of accurate RF sensors remain high, and dedicated RF monitoring networks remain rare. This paper describes a comprehensive study comprising the design of a low-cost RF-EMF sensor node capable of monitoring four frequency bands used by wireless telecommunications with an unparalleled temporal resolution, its application in a small-scale distributed sensor network consisting of both fixed (on building façades) and mobile sensor nodes (on postal vans), and the subsequent analysis of over a year of data between January 2019 and May 2020, during which slightly less than 10 million samples were collected. From the fixed nodes' results, the potential errors were determined that are induced when sampling at lower speeds (e.g., one sample per 15 min) and measuring for shorter periods of time (e.g., a few weeks), as well as an adequate resolution (30 min) for diurnal and weekly temporal profiles which sufficiently preserves short-term variations. Furthermore, based on the correlation between the sensors, an adequate density of 100 sensor nodes per km2 was deduced for future networks. Finally, the mobile sensor nodes were used to identify potential RF-EMF exposure hotspots in a previously unattainable area of more than 60 km2. In summary, through the analysis of a small number of RF-EMF sensor nodes (both fixed and mobile) in an urban area, this study offers invaluable insights applicable to future designs and deployments of distributed RF-EMF sensor networks.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Cidades , Exposição Ambiental/análise , Ondas de Rádio
7.
Environ Health ; 20(1): 36, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794922

RESUMO

BACKGROUND: The general population is exposed to Radio-Frequency Electromagnetic Fields (RF-EMFs) used by telecommunication networks. Previous studies developed methods to assess this exposure. These methods will be inadequate to accurately assess exposure in 5G technologies or other wireless technologies using adaptive antennas. This is due to the fact that 5G NR (new radio) base stations will focus actively on connected users, resulting in a high spatio-temporal variations in the RF-EMFs. This increases the measurement uncertainty in personal measurements of RF-EMF exposure. Furthermore, a user's exposure from base stations will be dependent on the amount of data usage, adding a new component to the auto-induced exposure, which is often omitted in current studies. GOALS: The objective of this paper is to develop a general study protocol for future personal RF-EMF exposure research adapted to 5G technologies. This protocol will include the assessment of auto-induced exposure of both a user's own devices and the networks' base stations. METHOD: This study draws from lessons learned from previous RF-EMF exposure research and current knowledge on 5G technologies, including studies simulating 5G NR base stations and measurements around 5G NR test sites. RESULTS: To account for auto-induced exposure, an activity-based approach is introduced. In survey studies, an RF-EMF sensor is fixed on the participants' mobile device(s). Based on the measured power density, GPS data and movement and proximity sensors, different activities can be clustered and the exposure during each activity is evaluated. In microenvironmental measurements, a trained researcher performs measurements in predefined microenvironments with a mobile device equipped with the RF-EMF sensor. The mobile device is programmed to repeat a sequence of data transmission scenarios (different amounts of uplink and downlink data transmissions). Based on simulations, the amount of exposure induced in the body when the user device is at a certain location relative to the body, can be evaluated. CONCLUSION: Our protocol addresses the main challenges to personal exposure measurement introduced by 5G NR. A systematic method to evaluate a user's auto-induced exposure is introduced.


Assuntos
Redes de Comunicação de Computadores , Campos Eletromagnéticos , Monitoramento Ambiental/métodos , Ondas de Rádio , Computadores de Mão , Humanos
8.
Artigo em Inglês | MEDLINE | ID: mdl-32722208

RESUMO

Nowadays, information and communication technologies (mobile phones, connected objects) strongly occupy our daily life. The increasing use of these technologies and the complexity of network infrastructures raise issues about radiofrequency electromagnetic fields (Rf-Emf) exposure. Most previous studies have assessed individual exposure to Rf-Emf, and the next level is to assess populational exposure. In our study, we designed a statistical tool for Rf-Emf populational exposure assessment and mapping. This tool integrates geographic databases and surrogate models to characterize spatiotemporal exposure from outdoor sources, indoor sources, and mobile phones. A case study was conducted on a 100 × 100 m grid covering the 14th district of Paris to illustrate the functionalities of the tool. Whole-body specific absorption rate (SAR) values are 2.7 times higher than those for the whole brain. The mapping of whole-body and whole-brain SAR values shows a dichotomy between built-up and non-built-up areas, with the former displaying higher values. Maximum SAR values do not exceed 3.5 and 3.9 mW/kg for the whole body and the whole brain, respectively, thus they are significantly below International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommendations. Indoor sources are the main contributor to populational exposure, followed by outdoor sources and mobile phones, which generally represents less than 1% of total exposure.


Assuntos
Telefone Celular , Comunicação , Campos Eletromagnéticos , Exposição Ambiental , Campos Eletromagnéticos/efeitos adversos , Humanos , Ondas de Rádio/efeitos adversos
9.
Environ Res ; 183: 109196, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32032814

RESUMO

This paper describes radiofrequency (RF) electromagnetic field (EMF) measurements in the vicinity of single and banks of advanced metering infrastructure (AMI) smart meters. The measurements were performed in a meter testing and distribution facility as well as in-situ at five urban locations. The measurements consisted of gauging the RF environment at the place of assessment, evaluating the worst-case electric-field levels at various positions around the assessed AMI meter configuration (spatial assessment), which ranged from a single meter to a bank of 81 m, and calculating the duty cycle of the system, i.e. the fraction of time that the AMI meters were actually transmitting (12-h temporal assessment). Both in-situ and in the meter facility, the maximum field levels at 0.3 m from the meter configurations were 10-13 V/m for a single meter and 18-38 V/m for meter banks with 20-81 m. Furthermore, 6-min average duty cycles of 0.01% (1 m) up to 13% (81-m bank) were observed. Next, two general statistical models (one for a single meter and one for a meter bank) were constructed to predict the electric-field strength as a function of distance to any configuration of the assessed AMI meters. For all scenarios, the measured exposure levels (at a minimum distance of 0.3 m) were well below the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the U.S. Federal Communications Commission (FCC), and the Institute of Electrical and Electronics Engineers (IEEE). Indeed, the worst-case time-average exposure level at a distance of 0.3 m from an AMI installation was 5.39% of the FCC/IEEE and 9.43% of the ICNIRP reference levels.


Assuntos
Campos Eletromagnéticos , Exposição Ambiental , Ondas de Rádio , Eletricidade , Monitoramento Ambiental , Modelos Estatísticos , Radiação Ionizante
10.
Environ Res ; 175: 1-10, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31096087

RESUMO

When making phone calls, cellphone and smartphone users are exposed to radio-frequency (RF) electromagnetic fields (EMFs) and sound pressure simultaneously. Speech intelligibility during mobile phone calls is related to the sound pressure level of speech relative to potential background sounds and also to the RF-EMF exposure, since the signal quality is correlated with the RF-EMF strength. Additionally, speech intelligibility, sound pressure level, and exposure to RF-EMFs are dependent on how the call is made (on speaker, held at the ear, or with headsets). The relationship between speech intelligibility, sound exposure, and exposure to RF-EMFs is determined in this study. To this aim, the transmitted RF-EMF power was recorded during phone calls made by 53 subjects in three different, controlled exposure scenarios: calling with the phone at the ear, calling in speaker-mode, and calling with a headset. This emitted power is directly proportional to the exposure to RF EMFs and is translated into specific absorption rate using numerical simulations. Simultaneously, sound pressure levels have been recorded and speech intelligibility has been assessed during each phone call. The results show that exposure to RF-EMFs, quantified as the specific absorption in the head, will be reduced when speaker-mode or a headset is used, in comparison to calling next to the ear. Additionally, personal exposure to sound pressure is also found to be highest in the condition where the phone is held next to the ear. On the other hand, speech perception is found to be the best when calling with a phone next to the ear in comparison to the other studied conditions, when background noise is present.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Ondas de Rádio , Inteligibilidade da Fala , Telefone Celular/instrumentação , Telefone Celular/normas , Humanos , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle
11.
Health Phys ; 116(6): 776-788, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30883437

RESUMO

The advent of the Internet of things comes with a huge increase in wirelessly communicating devices in our environment. For example, smart energy-consumption meters are being widely deployed in residences from which they communicate their state using radiofrequency networks. Accurate characterization of the radiofrequency emissions from emerging residential wireless solutions is important to inform the public about the potential impact on their exposure to radiofrequency electromagnetic fields. A new measurement procedure to determine the exposure from residential radiofrequency devices is proposed by assessing the peak emitted fields at various distances and the proportion of time they transmit (duty cycle). Radiofrequency emissions from 55 residential devices were measured in 10 residences (Belgium and France) and compared to environmental levels, emissions from 41 mobile phones, and international standards. Overall, residential levels of radiofrequency electromagnetic field exposure are low. In addition to the continuous environmental exposure, wireless access points (due to frequent use) and especially mobile phones and other personal communication devices (due to their use close to the body) continue to represent the bulk of the radiofrequency electromagnetic field exposure in the smart home. However, some residential devices can significantly increase the exposure if their duty cycles are high enough (>10%), especially when held or used close to the body. Individual smart meters, on the other hand, will contribute only little in general, despite emissions of up to 20 V m at 50 cm, due to their low duty cycles (maximum 1%) and locations.


Assuntos
Telefone Celular/estatística & dados numéricos , Campos Eletromagnéticos , Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Ondas de Rádio , Eletricidade , Humanos
12.
Environ Res ; 161: 136-143, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29145005

RESUMO

As both the environment and telecommunications networks are inherently dynamic, our exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) at an arbitrary location is not at all constant in time. In this study, more than a year's worth of measurement data collected in a fixed low-cost exposimeter network distributed over an urban environment was analysed and used to build, for the first time, a full spatio-temporal surrogate model of outdoor exposure to downlink Global System for Mobile Communications (GSM) and Universal Mobile Telecommunications System (UMTS) signals. Though no global trend was discovered over the measuring period, the difference in measured exposure between two instances could reach up to 42dB (a factor 12,000 in power density). Furthermore, it was found that, taking into account the hour and day of the measurement, the accuracy of the surrogate model in the area under study was improved by up to 50% compared to models that neglect the daily temporal variability of the RF signals. However, further study is required to assess the extent to which the results obtained in the considered environment can be extrapolated to other geographic locations.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Exposição Ambiental , Monitoramento Ambiental , Comunicação , Custos e Análise de Custo , Humanos , Ondas de Rádio
13.
Environ Res ; 154: 160-170, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28086101

RESUMO

Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300Hz to 1MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6kHz and 300kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20cm were 41.5V/m and 2.7A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20cm and beyond (maximum exposure quotients EQE 1.0 and EQH 0.13).


Assuntos
Campos Eletromagnéticos/efeitos adversos , Exposição Ambiental/efeitos adversos , Habitação , Iluminação/efeitos adversos , Campos Magnéticos/efeitos adversos , Bélgica , Monitoramento Ambiental , Humanos , Eslovênia , Reino Unido
14.
Environ Int ; 94: 482-488, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27364986

RESUMO

Knowledge of spatial and temporal trends in the environmental exposure to radiofrequency electromagnetic fields (RF-EMF) is a key prerequisite for RF-EMF risk assessment studies attempting to establish a link between RF-EMF and potential effects on human health as well as on fauna and flora. In this paper, we determined the validity of RF exposure modelling based on inner-area kriging interpolation of measurements on the surrounding streets. The results vary depending on area size and shape and structural factors; a Spearman coefficient of 0.8 and a relative error of less than 3.5dB are achieved on a data set featuring a closed measurement ring around a decently sized area (1km(2), with an average minimum distance of the encircled area to the ring of less than 100m), containing mainly low, detached buildings. In larger areas, additional inner-area sampling is advised, lowering the average minimum distance between sampled and interpolated locations to 100m, to achieve the same level of accuracy.


Assuntos
Campos Eletromagnéticos , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Ondas de Rádio , Automóveis , Inglaterra , Países Baixos , Análise Espacial
15.
Bioelectromagnetics ; 37(3): 195-199, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26969843

RESUMO

For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. 37:195-199, 2016. © 2016 Wiley Periodicals, Inc.

16.
Bioelectromagnetics ; 36(8): 597-602, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26511787

RESUMO

For the first time, the contribution of radio-frequent radiation originating from other people's devices to total own whole-body absorption is assessed in a simulation study. Absorption in a train environment due to base station's downlink is compared with absorption due to uplink (UL) of the user's own mobile device and absorption due to the UL of 0, 1, 5, or 15 other nearby active users. In a Global System for Mobile Communications (GSM) macro cell connection scenario, UL of 15 other users can cause up to 19% of total absorption when calling yourself and up to 100% when not calling yourself. In a Universal Mobile Telecommunications System (UMTS) femtocell connection scenario, UL of 15 other users contributes to total absorption of a non-calling user for no more than 1.5%. For five other users in the train besides the considered person, median total whole-body Specific Absorption Rate is reduced by a factor of about 400000 when deploying a UMTS femtocell base station instead of relying on the GSM macrocell.


Assuntos
Absorção de Radiação , Monitoramento de Radiação , Ondas de Rádio , Meios de Transporte , Telefone Celular , Humanos
17.
Bioelectromagnetics ; 36(6): 451-63, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26113174

RESUMO

This paper presents a new metric to evaluate electromagnetic exposure induced by wireless cellular networks. This metric takes into account the exposure induced by base station antennas as well as exposure induced by wireless devices to evaluate average global exposure of the population in a specific geographical area. The paper first explains the concept and gives the formulation of the Exposure Index (EI). Then, the EI computation is illustrated through simple phone call scenarios (indoor office, in train) and a complete macro urban data long-term evolution scenario showing how, based on simulations, radio-planning predictions, realistic population statistics, user traffic data, and specific absorption rate calculations can be combined to assess the index. Bioelectromagnetics. 36:451-463, 2015. © 2015 Wiley Periodicals, Inc.


Assuntos
Telefone Celular/instrumentação , Redes de Comunicação de Computadores/instrumentação , Exposição Ambiental/análise , Monitoramento de Radiação/métodos , Tecnologia sem Fio/instrumentação , Adulto , Idoso , Criança , Campos Eletromagnéticos/efeitos adversos , Feminino , Humanos , Masculino
18.
Int J Environ Res Public Health ; 12(3): 2639-52, 2015 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-25734793

RESUMO

The deployment of a miniature mobile-phone base station or small cell in a train car significantly improves the coverage and the capacity of a mobile network service on the train. However, the impact of the small cell on the passengers' exposure to radio-frequency electromagnetic fields (RF-EMF) is unknown. In this study, we assessed experimentally the RF-EMF exposure of a mobile-phone user who is either connected to the outdoor macrocell network or to an in-train small cell, while traveling on the train, by means of the absorbed-dose concept, which combines the base station downlink exposure with the mobile-phone uplink exposure. For Global System for Mobile Communications (GSM) technology at 1800 MHz, we found that by connecting to a small cell, the brain exposure of the user could realistically be reduced by a factor 35 and the whole-body exposure by a factor 11.


Assuntos
Telefone Celular , Campos Eletromagnéticos/efeitos adversos , Exposição Ambiental , Ondas de Rádio/efeitos adversos , Tecnologia sem Fio , Humanos , Modelos Teóricos , Monitoramento de Radiação , Ferrovias , Tecnologia sem Fio/instrumentação
19.
Health Phys ; 108(4): 407-18, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25706134

RESUMO

This paper describes the design, calibration, and measurements with a personal, distributed exposimeter (PDE) for the on-body detection of radio frequency (RF) electromagnetic fields due to Wireless Fidelity (WiFi) networks. Numerical simulations show that using a combination of two RF nodes placed on the front and back of the body reduces the 50% prediction interval (PI50) on the incident free-space electric-field strength (Equation is included in full-text article.). Median reductions of 10 dB and 9.1 dB are obtained compared to the PI50 of a single antenna placed on the body using a weighted arithmetic and geometric average, respectively. Therefore, a simple PDE topology based on two nodes, which are deployed on opposite sides of the human torso, is applied for calibration and measurements. The PDE is constructed using flexible, dual-polarized textile antennas and wearable electronics, which communicate wirelessly with a Universal Serial Bus (USB) connected receiver and can be unobtrusively integrated into a garment. The calibration of the PDE in an anechoic chamber proves that the PI50 of the measured (Equation is included in full-text article.)is reduced to 3.2 dB. To demonstrate the real-life usability of the wireless device, a subject was equipped with the PDE during a walk in the city of Ghent, Belgium. Using a sample frequency of 2 Hz, an average incident power density of 59 nW m was registered in the WiFi frequency band during this walk.


Assuntos
Campos Eletromagnéticos , Exposição Ambiental , Imagens de Fantasmas , Monitoramento de Radiação/instrumentação , Tecnologia sem Fio , Bélgica , Calibragem , Simulação por Computador , Humanos
20.
Radiat Prot Dosimetry ; 164(3): 252-64, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25125596

RESUMO

In this study, in situ exposure assessment of both electric and magnetic fields of different intermediate frequency (IF) sources is investigated. The authors investigated smart boards and touchscreens, energy-saving bulbs, fluorescent lamps, a portable hearing unit and an electrosurgical unit (ESU). For most of these sources, the electric field is the dominating quantity. International Commission on Non-Ionizing Radiation Protection reference levels are exceeded for touchscreens (44 kHz: up to 155.7 V m(-1) at 5 cm), energy-saving bulbs (38-52 kHz: up to 117.3 V m(-1)), fluorescent lamps (52 kHz: up to 471 V m(-1) at 5 cm) and ESUs (up to 920 kHz: 792 V m(-1) at 0.5 cm). Magnetic field strengths up to 1.8 and 10.5 A m(-1) were measured close to the ESU and portable hearing unit (69 V m(-1)), respectively. Large differences of measured field values exist among the various operating modes of the IF equipment. Compliance distances for general public range from 15.3 cm (touchscreen) to 25 cm (fluorescent lamps).


Assuntos
Campos Eletromagnéticos , Exposição Ambiental/análise , Exposição Ocupacional/análise , Monitoramento de Radiação , Proteção Radiológica , Humanos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA