Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Glob Health ; 14: 04086, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38751318

RESUMO

Background: It is imperative to maintain accurate documentation of clinical interventions aimed at enhancing the quality of care for newborns and sick children. The National Newborn Health and IMCI programme of Bangladesh led the development of a standardised register for managing newborns and sick children under five years of age during inpatient care through stakeholder engagement. We aimed to assess the implementation outcomes of the standardised register in the inpatient department. Methods: We conducted implementation research in two district hospitals and two sub-district hospitals of Kushtia and Dinajpur districts from November 2022 to January 2023 to assess the implementation outcomes of the standardised register. We assessed the following World Health Organization implementation outcome variables: usability, acceptability, adoption (actual use), fidelity (completeness and accuracy), and utility (quality of care) of the register against preset benchmarks. We collected data through structured interviews with health care providers; participant enrolment; and data extraction from inpatient registers and case record forms. Results: The average usability and acceptability scores among health care providers were 73 (standard deviation (SD) = 14) and 82 (SD = 14) out of 100, respectively. The inpatient register recorded 96% (95% confidence interval (CI) = 95-97) of under-five children who were admitted to the inpatient department (adoption - actual use). The proportions of completed data elements in the inpatient register were above the preset benchmark of 70% for all the assessed data elements except 'investigation done' (24%; 95% CI = 23-26) (fidelity - completeness). The percentage agreements between government-appointed nurses posted and study-appointed nurses were above the preset benchmark of 70% for all the reported variables (fidelity - accuracy). The kappa coefficient for the overall level of agreement between these two groups regarding reported variables indicated moderate to substantial agreement. The proportion of newborns with sepsis receiving injectable antibiotics was 62% (95% CI = 47-75) (utility - quality of care). We observed some variability in the completeness and accuracy of the inpatient register by district and facility type. Conclusions: The inpatient register was positively received by health care providers, with evaluations of implementation outcome variables showing encouraging results. Our findings could inform evidence-based decision-making on the implementation and scale-up of the inpatient register in Bangladesh, as well as other low- and middle-income countries.


Assuntos
Sistema de Registros , Humanos , Bangladesh , Recém-Nascido , Lactente , Pré-Escolar , Instalações de Saúde/normas , Hospitalização/estatística & dados numéricos , Pacientes Internados/estatística & dados numéricos , Qualidade da Assistência à Saúde
2.
J Glob Health ; 12: 04036, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35493782

RESUMO

Background: Hypoxaemia is one of the strongest predictors of mortality among children with pneumonia. It can be identified through pulse oximetry instantaneously, which is a non-invasive procedure but can be influenced by factors related to the specific measuring device, health provider and patient. Following WHO's global recommendation in 2014, Bangladesh decided to introduce pulse oximetry in paediatric outpatient services, ie, the Integrated Management of Childhood Illness (IMCI) services in 2019. A national committee updated the existing IMCI implementation package and decided to test it by assessing the pulse oximetry performance of different types of assessors in real-life inpatient settings. Methods: We adopted an observational design and conducted a technology assessment among children admitted to a rural district hospital. Eleven nurses and seven paramedics received one-day training on pulse oximetry as assessors. Each assessor performed at least 30 pulse oximetry measurements on children with two types of handheld devices. The primary outcome of interest was obtaining a successful measurement of SpO2, defined as observing a stable (±1%) reading for at least 10 seconds. Performance time, ie, time taken to obtain a successful measurement of SpO2 was considered the secondary outcome of interest. In addition, we used Generalized Estimating Equation to assess the effect of different factors on the pulse oximetry performance. Results: The assessors obtained successful measurements of SpO2 in all attempts (n = 1478) except one. The median time taken was 30 (interquartile range (IQR) = 22-42) seconds, and within 60 seconds, 92% of attempts were successful. The odds of obtaining a successful measurement within 60 seconds were 7.3 (95% confidence interval (CI) = 3.7-14.2) times higher with a Masimo device than a Lifebox device. Similarly, assessors aged >25 years were 4.8 (95% CI = 1.2, 18.6) times more likely to obtain a successful measurement within 60 seconds. The odds of obtaining a successful measurement was 2.6 (95% CI = 1.6, 4.2) times higher among children aged 12-59 months compared to 2-11 months. Conclusions: Our study indicated that assessors could achieve the necessary skills to perform pulse oximetry successfully in real-life inpatient settings through a short training module, with some effect of device-, provider- and patient-related factors. The National IMCI Programme of Bangladesh can use these findings for finalising the national IMCI training modules and implementation package incorporating the recommendation of using pulse oximetry for childhood pneumonia assessment.


Assuntos
Criança Hospitalizada , Pneumonia , Bangladesh , Criança , Humanos , Hipóxia , Oximetria , Pneumonia/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA