Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Turk Kardiyol Dern Ars ; 46(2): 140-142, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29512615

RESUMO

Contrast-induced encephalopathy (CIE) is a rare complication of angiography. Presently reported is the case of a patient diagnosed with CIE following peripheral angioplasty with the non-ionic contrast agent, iohexol. A 66-year-old male patient described intermittent claudication and peripheral arterial disease was suspected. Lower extremity angiography was performed, and following dilation of a 7.0x150-mm balloon, a 9.0x57-mm stent was placed in the lesioned vessel. The patient subsequently developed confusion and cortical blindness, and a seizure occurred 1 hour after the procedure. An emergency cerebral computed tomography scan did not reveal any signs of intracerebral hemorrhage. The neurological symptoms disappeared within 24 hours after hydration and sedative medication. CIE was diagnosed based on the patient`s clinical course findings and cerebral imaging.


Assuntos
Angiografia/efeitos adversos , Encefalopatias/induzido quimicamente , Meios de Contraste/uso terapêutico , Iohexol/uso terapêutico , Idoso , Cegueira/induzido quimicamente , Meios de Contraste/efeitos adversos , Humanos , Iohexol/efeitos adversos , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Convulsões/induzido quimicamente
2.
Echocardiography ; 34(11): 1714-1716, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29071746

RESUMO

A 24-year-old man was admitted to our outpatient clinic for his routine checkup of consecutively percutaneously treated atrial septal defect (ASD) and pulmonary valvular stenosis 45 days ago. A 24 mm ASD occluder device was implanted under transthoracic echocardiographic guidance and 80 mm Hg peak-to-peak pulmonary valvular gradient decreased to 20 mm Hg gradient after pulmonary valve dilatation with 23 mm NUMED II transluminal valvuloplasty catheter balloon. Atrial septal defect (ASD) closure is now routinely performed using a percutaneous approach under echocardiographic guidance especially transthoracic echocardiography (TEE). Centrally located, ostium secundum type and less than 3.5 cm in size are considered ideal for device closure. Although there is considerable variation in size and location of the defects, TEE guidance is quite important for this proportion of ASDs. The selection of patients for percutaneous transcatheter closure of a secundum ASD requires accurate information regarding the anatomy of the defect such as its maximal diameter and the amount of circumferential tissue rims.


Assuntos
Ecocardiografia/métodos , Migração de Corpo Estranho/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Estenose da Valva Pulmonar/complicações , Dispositivo para Oclusão Septal , Adulto , Migração de Corpo Estranho/cirurgia , Comunicação Interatrial/complicações , Ventrículos do Coração/cirurgia , Humanos , Masculino , Resultado do Tratamento , Adulto Jovem
3.
Heart Lung Circ ; 26(10): 1069-1078, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28162948

RESUMO

BACKGROUND: The aims of this study were to examine the ophthalmic artery flow changes in patients with obstructive carotid artery disease, evaluate the orbital blood flow changes after carotid artery stenting and assess the safety of carotid stenting procedure by using transorbital colour and spectral Doppler sonography. METHODS: Thirty-one consecutive patients scheduled for carotid stenting with severe internal carotid artery stenosis (>60%; the study group) and 30 control subjects were included. Ophthalmic artery (OA) Doppler sonography was performed in the control group and study group before and after stenting. Peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility index (PI), and resistive index (RI) and systolic/diastolic ratio (S/D) in the ophthalmic artery were recorded. Statistical comparisons were made between controls and study group before stenting and before and after stenting in the study group. RESULTS: Comparison between control and study group before stenting revealed a statistically significant decrease in OA PSV (51.5±14.5 vs. 39.7±19cm/sec, p= 0.008) and EDV (15.2±4.5 vs. 11.3±5.7cm/sec, p=0.004) in the study group. Differences in PI (1.3±0.14 vs. 1.36±0.4, p=0.47), RI (0.7±0.04 vs. 0.75±0.21, p=0.19), and S/D (3.5±0.6 vs. 3.6±1, p= 0.5) ratio were not statistically significant between groups. Peak systolic velocity (39.7±18.9 vs. 51.3±22.2cm/sec, p <0.001), RI (0.75±0.21 vs. 0.81±0.13, p=0.16) and S/D ratio (3.6±1 vs. 4.6±1.5, p= 0.001) were found to be significantly increased in the study group after stenting compared to baseline. There were no statistically significant differences in EDV and RI EDV(11.3±5.7 vs. 11.7±5.7cm/sec, p=0.66), PI (1.36±0.4 vs. 1.6±0.6, p =0.047) after stenting. CONCLUSIONS: Ophthalmic artery flow parameters were significantly lower in patients with severe carotid artery stenosis compared to control, indicating compromised ocular blood flow in severe carotid stenosis. Flow indicators significantly improved after stent implantation suggesting the importance of revascularisation in restoring ocular blood flow and safety of carotid stenting.


Assuntos
Circulação Sanguínea/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Implante de Prótese Vascular/métodos , Artéria Carótida Primitiva/cirurgia , Estenose das Carótidas/cirurgia , Olho/irrigação sanguínea , Artéria Oftálmica/fisiopatologia , Stents , Idoso , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Oftálmica/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia Doppler em Cores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA