Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Radiat Prot Dosimetry ; 199(15-16): 1968-1972, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819306

RESUMO

In proton therapy, most treatment planning systems (TPS) use a fixed relative biological effectiveness (RBE) of 1.1 all along the depth-dose profile. Innovative TPS are now investigated considering the variability of RBE with radiation quality. New TPS need an experimental verification in the quality assurance (QA) routine in clinics, but RBE data are usually obtained with radiobiological measurements that are time consuming and not suitable for daily QA. Microdosimetry is a useful tool based on physical measurements which can monitor the radiation quality. Several microdosimeters are available in different research institutions, which could potentially be used for the QA in TPS. In this study, the response functions of five detectors in the same 62-MeV proton Spread Out Bragg Peak is compared in terms of spectral distributions and their average values and microdosimetric RBE. Their different response function has been commented and must be considered in the clinical practice.


Assuntos
Terapia com Prótons , Prótons , Radiometria , Eficiência Biológica Relativa
2.
Phys Med Biol ; 67(16)2022 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-35679848

RESUMO

Objective.In the present hadrontherapy scenario, there is a growing interest in exploring the capabilities of different ion species other than protons and carbons. The possibility of using different ions paves the way for new radiotherapy approaches, such as the multi-ions treatment, where radiation could vary according to target volume, shape, depth and histologic characteristics of the tumor. For these reasons, in this paper, the study and understanding of biological-relevant quantities was extended for the case of4He ion.Approach.Geant4 Monte Carlo based algorithms for dose- and track-averaged LET (Linear Energy Transfer) calculations, were validated for4He ions and for the case of a mixed field characterised by the presence of secondary ions from both target and projectile fragmentation. The simulated dose and track averaged LETs were compared with the corresponding dose and frequency mean values of the lineal energy,yD¯andy¯F, derived from experimental microdosimetric spectra. Two microdosimetric experimental campaigns were carried out at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud of Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) using two different microdosimeters: the MicroPlus probe and the nano-TEPC (Tissue Equivalent Proportional Counter).Main results.A good agreement ofL¯dTotalandL¯tTotalwithy¯Dandy¯Texperimentally measured with both microdosimetric detectors MicroPlus and nano-TEPC in two configurations: full energy and modulated4He ion beam, was found.Significance.The results of this study certify the use of a very effective tool for the precise calculation of LET, given by a Monte Carlo approach which has the advantage of allowing detailed simulation and tracking of nuclear interactions, even in complex clinical scenarios.


Assuntos
Transferência Linear de Energia , Radiometria , Algoritmos , Íons , Método de Monte Carlo , Prótons , Radiometria/métodos
3.
Phys Med ; 89: 226-231, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34425513

RESUMO

The aim of the NEPTUNE (Nuclear process-driven Enhancement of Proton Therapy UNravEled) project is to investigate in detail both the physical and radiobiological phenomena that could justify an increase of the proton-induced cytogenetic effects in cells irradiated in presence of an agent containing natural boron. In this work, a double-stage silicon telescope coupled to different boron converters was irradiated at the CATANA proton therapy facility (INFN-LNS) for studying the proton boron fusion and the neutron boron capture reactions by discriminating secondary particles from primary protons. Different boron targets were developed by depositing boric acid, enriched with a higher than 99% content of 10B or 11B, on a 50 µm thick PolyMethilMetacrylate (PMMA) substrate. The 10B target allows to evaluate the contribution of lithium and alpha particles produced by the boron neutron capture reaction triggered by secondary thermal neutrons, while the 11B target is exploited for studying the effect of the p + 11B → 3α nuclear reaction directly triggered by primary protons. Experimental results clearly show the presence of alpha particles from both the reactions. The silicon telescope is capable of discriminating, by means of the so-called "scatter plots", the contribution of alpha particles originated by thermal neutrons on 10B with respect to the ones produced by protons impinging on 11B. Although a reliable quantitative study of the alpha production rate has not been achieved yet, this work demonstrates that low energy and, therefore, high-LET particles from both the reactions can be measured.


Assuntos
Terapia por Captura de Nêutron de Boro , Terapia com Prótons , Boro , Nêutrons , Prótons
4.
Phys Med Biol ; 65(23): 235043, 2020 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-33263314

RESUMO

We exploited the power of the Geant4 Monte Carlo toolkit to study and validate new approaches for the averaged linear energy transfer (LET) calculation in 62 MeV clinical proton beams. The definitions of the averaged LET dose and LET track were extended, so as to fully account for the contribution of secondary particles generated by target fragmentation, thereby leading to a more general formulation of the LET total. Moreover, in the proposed new strategies for the LET calculation, we minimised the dependencies in respect to the transport parameters adopted during the Monte Carlo simulations (such as the production cut of secondary particles, voxel size and the maximum steplength). The new proposed approach was compared against microdosimetric experimental spectra of clinical proton beams, acquired at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) from two different detectors: a mini-tissue equivalent proportional chamber (TEPC), developed at the Legnaro National Laboratories of the National Institute for Nuclear Physics (LNL-INFN) and a silicon-on-insulator (SOI) microdosimeter with 3D sensitive volumes developed by the Centre for Medical Radiation Physics of Wollongong University (CMRP-UoW). A significant increase of the LET in the entrance region of the spread out Bragg peak (SOBP) was observed, when the contribution of the generated secondary particles was included in the calculation. This was consistent with the experimental results obtained.


Assuntos
Algoritmos , Transferência Linear de Energia , Método de Monte Carlo , Terapia com Prótons , Doses de Radiação , Humanos , Dosagem Radioterapêutica
5.
Phys Med Biol ; 65(24): 245018, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33086208

RESUMO

Proton beams are widely used worldwide to treat localized tumours, the lower entrance dose and no exit dose, thus sparing surrounding normal tissues, being the main advantage of this treatment modality compared to conventional photon techniques. Clinical proton beam therapy treatment planning is based on the use of a general relative biological effectiveness (RBE) of 1.1 along the whole beam penetration depth, without taking into account the documented increase in RBE at the end of the depth dose profile, in the Bragg peak and beyond. However, an inaccurate estimation of the RBE can cause both underdose or overdose, in particular it can cause the unfavourable situation of underdosing the tumour and overdosing the normal tissue just beyond the tumour, which limits the treatment success and increases the risk of complications. In view of a more precise dose delivery that takes into account the variation of RBE, experimental microdosimetry offers valuable tools for the quality assurance of LET or RBE-based treatment planning systems. The purpose of this work is to compare the response of two different microdosimetry systems: the mini-TEPC and the MicroPlus-Bridge detector. Microdosimetric spectra were measured across the 62 MeV spread out Bragg peak of CATANA with the mini-TEPC and with the Bridge microdosimeter. The frequency and dose distributions of lineal energy were compared and the different contributions to the spectra were analysed, discussing the effects of different site sizes and chord length distributions. The shape of the lineal energy distributions measured with the two detectors are markedly different, due to the different water-equivalent sizes of the sensitive volumes: 0.85 µm for the TEPC and 17.3 µm for the silicon detector. When the Loncol's biological weighting function is applied to calculate the microdosimetric assessment of the RBE, both detectors lead to results that are consistent with biological survival data for glioma U87 cells. Both the mini-TEPC and the MicroPlus-Bridge detector can be used to assess the RBE variation of a 62 MeV modulated proton beam along its penetration depth. The microdosimetric assessment of the RBE based on the Loncol's weighting function is in good agreement with radiobiological results when the 10% biological uncertainty is taken into account.


Assuntos
Terapia com Prótons , Radiometria , Eficiência Biológica Relativa , Humanos , Silício
6.
Radiat Prot Dosimetry ; 183(1-2): 177-181, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30535177

RESUMO

The tissue-equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam but, since the lower operation limit of common TEPCs is ~0.3 µm, no detailed information on the track structure of the impinging particles can be obtained. The pattern of particle interactions at the nanometric level is measured directly by only three different nanodosimeters worldwide: practical instruments are not yet available. In order to partially fill the gap between microdosimetry and track-nanodosimetry, a low-pressure avalanche-confinement TEPC was designed and constructed for simulating tissue-equivalent sites down to the nanometric region. The present paper aims at describing the response of this TEPC in the range 0.3 µm-25 nm to a 62 MeV/n 4He ion beam. The experimental results, for depths near the Bragg peak, show good agreement with FLUKA simulations and suggest that, for smaller depths, the distribution is highly influenced by secondary electrons.


Assuntos
Hélio/química , Nanotecnologia , Radiometria/instrumentação , Simulação por Computador , Desenho de Equipamento , Modelos Teóricos
7.
Phys Med ; 52: 113-121, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30139599

RESUMO

PURPOSE: The aim of this paper is to investigate the limits of LET monitoring of therapeutic carbon ion beams with miniaturized microdosimetric detectors. METHODS: Four different miniaturized microdosimeters have been used at the 62 MeV/u 12C beam of INFN Southern National Laboratory (LNS) of Catania for this purpose, i.e. a mini-TEPC and a GEM-microdosimeter, both filled with propane gas, and a silicon and a diamond microdosimeter. The y-D (dose-mean lineal energy) values, measured at different depths in a PMMA phantom, have been compared withLET¯D (dose-mean LET) values in water, calculated at the same water-equivalent depth with a Monte Carlo simulation setup based on the GEANT4 toolkit. RESULTS: In these first measurements, no detector was found to be significantly better than the others as a LET monitor. The y-D relative standard deviation has been assessed to be 13% for all the detectors. On average, the ratio between y-D and LET¯D values is 0.9 ±â€¯0.3, spanning from 0.73 ±â€¯0.08 (in the proximal edge and Bragg peak region) to 1.1 ±â€¯0.3 at the distal edge. CONCLUSIONS: All the four microdosimeters are able to monitor the dose-mean LET with the 11% precision up to the distal edge. In the distal edge region, the ratio of y-D to LET¯D changes. Such variability is possibly due to a dependence of the detector response on depth, since the particle mean-path length inside the detectors can vary, especially in the distal edge region.


Assuntos
Radiometria/instrumentação , Calibragem , Isótopos de Carbono/uso terapêutico , Simulação por Computador , Desenho de Equipamento , Radioterapia com Íons Pesados/instrumentação , Miniaturização , Método de Monte Carlo , Imagens de Fantasmas , Polimetil Metacrilato , Dosagem Radioterapêutica , Água
8.
Radiat Prot Dosimetry ; 180(1-4): 157-161, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29087524

RESUMO

The Italian National Centre for Oncological Hadrontherapy (CNAO) has been treating patients since 2011 with carbon-ion beams using the active-scanning modality. In such irradiation modality, the beam spot, which scans the treatment area, is characterised by very high particle-fluence rates (more than 105 s-1 mm-2). Moreover, the Bragg-peak is only ~1 mm-FWHM. Commercial tissue-equivalent proportional counters (TEPC), like the Far West Technologies LET-½, are large, hence they have limited capability to measure at high counting fluence rates. In this study we have used two home-made detectors, a mini-TEPC 0.81 mm2 in sensitive area and a silicon telescope 0.125 mm2 in sensitive area, to perform microdosimetric measurements in the therapeutic carbon-ion beam of CNAO. A monoenergetic carbon-ion beam of 189.5 ± 0.3 MeV/u scanning a 3 × 3 cm2 area has been used. Spectral differences are visible in the low y-value region, but the mean microdosimetric values, measured with the two detectors, result to be pretty consistent, as well as the microdosimetric spectra in the high y-value region.


Assuntos
Carbono/uso terapêutico , Instalações de Saúde , Microtecnologia/métodos , Aceleradores de Partículas/instrumentação , Monitoramento de Radiação/instrumentação , Radioterapia/instrumentação , Humanos , Transferência Linear de Energia
9.
Radiat Prot Dosimetry ; 180(1-4): 172-176, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036508

RESUMO

Tissue equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam, nevertheless no detailed information on the track structure of the impinging particles can be obtained, since the lower operation limit of common TEPCs is ~0.3 µm. On the other hand, the pattern of particle interactions at the nanometer level is measured by only three different nanodosimeters worldwide: practical instruments are not yet available. In order to partially fill the gap between microdosimetry and track-nanodosimetry, a low-pressure avalanche-confinement TEPC was recently designed and constructed for simulating tissue-equivalent sites down to the nanometric region. The present article aims at describing the response of this newly developed TEPC in the range 0.3 µm-25 nm against a fast neutron field from a 241Am-Be source and a quasi-monoenergetic neutron beam. The experimental results are in good agreement with Monte Carlo simulations carried out with the FLUKA code.


Assuntos
Microtecnologia/instrumentação , Nanotecnologia/instrumentação , Nêutrons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Amerício/análise , Desenho de Equipamento , Doses de Radiação
10.
Appl Radiat Isot ; 106: 145-50, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26249744

RESUMO

The reliability of Fricke gel dosimeters in form of layers for measurements aimed at the characterization of epithermal neutron beams has been studied. By means of dosimeters of different isotopic composition (standard, containing (10)B or prepared with heavy water) placed against the collimator exit, the spatial distribution of gamma and fast neutron doses and of thermal neutron fluence are attained. In order to investigate the accuracy of the results obtained with in-air measurements, suitable MC simulations have been developed and experimental measurements have been performed utilizing Fricke gel dosimeters, thermoluminescence detectors and activation foils. The studies were related to the epithermal beam designed for BNCT irradiations at the research reactor LVR-15 (Rez). The results of calculation and measurements have revealed good consistency of gamma dose and fast neutron 2D distributions obtained with gel dosimeters in form of layers. In contrast, noticeable modification of thermal neutron fluence is caused by the neutron moderation produced by the dosimeter material. Fricke gel dosimeters in thin cylinders, with diameter not greater than 3mm, have proved to give good results for thermal neutron profiling. For greater accuracy of all results, a better knowledge of the dependence of gel dosimeter sensitivity on radiation LET is needed.


Assuntos
Terapia por Captura de Nêutron/instrumentação , Dosagem Radioterapêutica , Modelos Teóricos , Método de Monte Carlo
11.
Appl Radiat Isot ; 69(12): 1664-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21478028

RESUMO

Neutron energy spectra at different emission angles, between 0° and 120° from the Be(p,xn) reaction generated by a beryllium thick-target bombarded with 5 MeV protons, have been measured at the Legnaro Laboratories (LNL) of the Italian National Institute for Nuclear Physics research (INFN). A new and quite compact recoil-proton spectrometer, based on a monolithic silicon telescope, coupled to a polyethylene converter, was efficiently used with respect to the traditional Time-of-Flight (TOF) technique. The measured distributions of recoil-protons were processed through an iterative unfolding algorithm in order to determine the neutron energy spectra at all the angles accounted for. The neutron energy spectrum measured at 0° resulted to be in good agreement with the only one so far available at the requested energy and measured years ago with TOF technique. Moreover, the results obtained at different emission angles resulted to be consistent with detailed past measurements performed at 4 MeV protons at the same angles by TOF techniques.

12.
Appl Radiat Isot ; 69(12): 1660-3, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21316253

RESUMO

Some remarkable advances have been made in the last years on the SPES-BNCT project of the Istituto Nazionale di Fisica Nucleare (INFN) towards the development of the accelerator-driven thermal neutron beam facility at the Legnaro National Laboratories (LNL), aimed at the BNCT experimental treatment of extended skin melanoma. The compact neutron source will be produced via the (9)Be(p,xn) reactions using the 5 MeV, 30 mA beam driven by the RFQ accelerator, whose modules construction has been recently completed, into a thick beryllium target prototype already available. The Beam Shaping Assembly (BSA) final modeling, using both neutron converter and the new, detailed, Be(p,xn) neutron yield spectra at 5 MeV energy recently measured at the CN Van de Graaff accelerator at LNL, is summarized here.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Modelos Teóricos , Desenho de Equipamento , Humanos , Melanoma/radioterapia , Neoplasias Cutâneas/radioterapia
13.
Radiat Prot Dosimetry ; 143(2-4): 432-5, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21147791

RESUMO

A silicon device based on the monolithic silicon telescope technology coupled to a tissue-equivalent converter was proposed and investigated for solid state microdosimetry. The detector is constituted by a ΔE stage about 2 µm in thickness geometrically segmented in a matrix of micrometric diodes and a residual-energy measurement stage E about 500 µm in thickness. Each thin diode has a cylindrical sensitive volume 9 µm in nominal diameter, similar to that of a cylindrical tissue-equivalent proportional counter (TEPC). The silicon device and a cylindrical TEPC were irradiated in the same experimental conditions with quasi-monoenergetic neutrons of energy between 0.64 and 2.3 MeV at the INFN-Legnaro National Laboratories (LNL-INFN, Legnaro, Italy). The aim was to study the capability of the silicon-based system of reproducing microdosimetric spectra similar to those measured by a reference microdosemeter. The TEPC was set in order to simulate a tissue site about 2 µm in diameter. The spectra of the energy imparted to the ▵E stage of the silicon telescope were corrected for tissue-equivalence through an optimized procedure that exploits the information from the residual energy measurement stage E. A geometrical correction based on parametric criteria for shape-equivalence was also applied. The agreement between the dose distributions of lineal energy and the corresponding mean values is satisfactory at each neutron energy considered.


Assuntos
Astronomia/instrumentação , Desenho Assistido por Computador , Monitoramento de Radiação/instrumentação , Silício/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiat Prot Dosimetry ; 131(1): 7-14, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18782783

RESUMO

Within the scope of CONRAD (A Coordinated Action for Radiation Dosimetry) Work Package 4 on Computational Dosimetry jointly collaborated with the other research actions on internal dosimetry, complex mixed radiation fields at workplaces and medical staff dosimetry. Besides these collaborative actions, WP4 promoted an international comparison on eight problems with their associated experimental data. A first set of three problems, the results of which are herewith summarised, dealt only with the expression of the stochastic uncertainties of the results: the analysis of the response function of a proton recoil telescope detector, the study of a Bonner sphere neutron spectrometer and the analysis of the neutron spectrum and dosimetric quantity H(p)(10) in a thermal neutron facility operated by IRSN Cadarache (the SIGMA facility). A second paper will summarise the results of the other five problems which dealt with the full uncertainty budget estimate. A third paper will present the results of a comparison on in vivo measurements of the (241)Am bone-seeker nuclide distributed in the knee. All the detailed papers will be presented in the WP4 Final Workshop Proceedings.


Assuntos
Radiometria , Radioterapia Assistida por Computador , Humanos , Modelos Teóricos , Nêutrons , Prótons , Radiometria/instrumentação , Radioterapia Assistida por Computador/instrumentação , Processos Estocásticos
15.
Radiat Prot Dosimetry ; 126(1-4): 640-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17576652

RESUMO

In-phantom dosimetry studies have been carried out at the thermal columns of a thermal- and a fast-nuclear reactor for investigating: (a) the spatial distribution of the gamma dose and the thermal neutron fluence and (b) the accuracy at which the boron concentration should be estimated in an explanted organ of a boron neutron capture therapy patient. The phantom was a cylinder (11 cm in diameter and 12 cm in height) of tissue-equivalent gel. Dose images were acquired with gel dosemeters across the axial section of the phantom. The thermal neutron fluence rate was measured with activation foils in a few positions of this phantom. Dose and fluence rate profiles were also calculated with Monte Carlo simulations. The trend of these profiles do not show significant differences for the thermal columns considered in this work.


Assuntos
Carga Corporal (Radioterapia) , Modelos Biológicos , Nêutrons , Reatores Nucleares/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Simulação por Computador , Humanos , Imagens de Fantasmas , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Radiat Prot Dosimetry ; 126(1-4): 69-73, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17504745

RESUMO

A new thermal neutron irradiation facility, devoted to carry out both dosimetric and radiobiological studies on boron carriers, which are being developed in the framework of INFN BNCT project, has been installed at the ENEA Casaccia TAPIRO research fast reactor. The thermal column, based on an original, hybrid, neutron spectrum shifter configuration, has been recently become operative. In spite of its low power (5 kW), the new facility is able to provide a high thermal neutron flux level, uniformly distributed inside the irradiation cavity, with a quite low gamma background. The main features and preliminary benchmark measurements of the Beam-shaping assembly are here presented and discussed.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Desenho Assistido por Computador , Nêutrons , Aceleradores de Partículas/instrumentação , Radiobiologia/instrumentação , Pesquisa/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Itália , Integração de Sistemas
17.
Radiat Prot Dosimetry ; 126(1-4): 210-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17522037

RESUMO

A neutron spectrometer was set-up by coupling a polyethylene converter with a monolithic silicon telescope, consisting of a DeltaE and an E stage-detector (about 2 and 500 microm thick, respectively). The detection system was irradiated with monoenergetic neutrons at INFN-Laboratori Nazionali di Legnaro (Legnaro, Italy). The maximum detectable energy, imposed by the thickness of the E stage, is about 8 MeV for the present detector. The scatter plots of the energy deposited in the two stages were acquired using two independent electronic chains. The distributions of the recoil-protons are well-discriminated from those due to secondary electrons for energies above 0.350 MeV. The experimental spectra of the recoil-protons were compared with the results of Monte Carlo simulations using the FLUKA code. An analytical model that takes into account the geometrical structure of the silicon telescope was developed, validated and implemented in an unfolding code. The capability of reproducing continuous neutron spectra was investigated by irradiating the detector with neutrons from a thick beryllium target bombarded with protons. The measured spectra were compared with data taken from the literature. Satisfactory agreement was found.


Assuntos
Nêutrons , Radiometria/instrumentação , Silício/química , Silício/efeitos da radiação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Radiat Prot Dosimetry ; 126(1-4): 310-3, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17519245

RESUMO

Bonner sphere spectrometers (BSS) are being used widely in neutron spectrometry since 1960. The response to neutrons of these moderating detectors spans over a broad energy range. This work discusses the measurement of the sensitivity of an extended range BSS hosting a CR39 nuclear track detector coupled to a boron converter. Two kinds of boron converters were tested, the first made by natural boron and a second one enriched in (10)B. The BSS response functions were calculated with Monte Carlo simulation using the MCNPX 2.4.0. and the FLUKA codes.


Assuntos
Nêutrons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Radiat Prot Dosimetry ; 122(1-4): 382-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17151010

RESUMO

A monolithic silicon telescope, consisting of a DeltaE and an E stage-detector ( approximately 1.9 microm and 500 microm thick, respectively), was coupled to a polyethylene converter in order to investigate the feasibility of a solid state microdosimeter with respect to the field-funnelling effect. This work discusses the preliminary results of an analytical approach for the correction of a spectrum measured with this silicon-based microdosimeter for tissue-equivalence and geometrical effects. The device was irradiated with 2.7 MeV monoenergetic neutrons at the INFN-Laboratori Nazionali di Legnaro (Legnaro, Italy). The non tissue-equivalence of silicon was corrected by exploiting the signals generated in the E-stage. The correction for the sensitive volume geometry was optimised by taking into account the track length distribution of the recoil-protons generated in the converter. The derived dose distribution of the energy imparted per event was compared to the one measured with a cylindrical tissue-equivalent proportional counter (TEPC). The agreement is satisfactory.


Assuntos
Óptica e Fotônica/instrumentação , Radiometria/instrumentação , Silício/química , Silício/efeitos da radiação , Desenho Assistido por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Nêutrons , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Radiat Prot Dosimetry ; 118(2): 144-54, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16698968

RESUMO

The QUADOS EU cost shared action conducted an intercomparison on the usage of numerical methods in radiation protection and dosimetry. The eight problems proposed were intended to test the usage of Monte Carlo and deterministic methods by assessing the accuracy with which the codes are applied and also the methods used to evaluate uncertainty in the answer gained through these methods. The overall objective was to spread good practice through the community and give users information on how to assess the uncertainties associated with their calculated results.


Assuntos
Nêutrons , Radiometria/métodos , Teorema de Bayes , Europa (Continente) , Humanos , Modelos Estatísticos , Método de Monte Carlo , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA